997 resultados para Polished surfaces


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Real-world environments comprise surfaces of different textures, densities and gradients, which can threaten postural stability and increase falls risk. However, there has been limited research that has examined how walking on compliant surfaces influences gait and postural stability in older people and PD patients. Methods: PD patients (n = 49) and age-matched controls (n = 32) were assessed using three dimensional motion analysis during self-paced walking on both firm and foam walkways. Falls were recorded prospectively over 12 months using daily falls calendars. Results: Walking on a foam surface influenced the temporospatial characteristics for all groups, but PD fallers adopted very different joint kinematics compared with controls. PD fallers also demonstrated reduced toe clearance and had increased mediolateral head motion(relative to walking velocity) compared with control participants. Conclusions: Postural control deficits in PD fallers may impair their capacity to attenuate surface-related perturbations and control head motion. The risk of falling for PD patients may be increased on less stable surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiconductor epitaxial nanostructures have been recently proposed as the key building blocks of many innovative applications in materials science and technology. To bring their tremendous potential to fruition, a fine control of nanostructure size and placement is necessary. We present a detailed investigation of the self-ordering process in the prototype case of Ge/Si heteroepitaxy. Starting from a bottom-up strategy (step-bunching instabilities), our analysis moves to lithographic techniques (scanning tunneling lithography, nanomechanical stamping, focused ion beam patterning) with the aim of developing a hybrid approach in which the exogenous intervention is specifically designed to suit and harness the natural self-organization dynamics of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface amorphous layer of articular cartilage is of primary importance to its load-bearing and lubrication function. This lipid-filled layer is degraded/disrupted or eliminated when cartilage degenerates due to diseases. This article examines further the characteristic of this surface overlay using a combination of microscopy and imaging methods to evaluate the hypothesis that the surface of articular cartilage can be repaired by exposing degraded cartilage to aqueous synthetic lipid mixtures. The preliminary results demonstrate that it is possible to create a new surface layer of phospholipids on the surface of cartilage following artificial lipid removal, but such a layer does not possess enough mechanical strength for physiological function when created with either unsaturated palmitoyloleoyl- phosphatidylcholine or saturated dipalmitoyl-phosphatidylcholine component of joint lipid composition alone. We conclude that this may be due to low structural cohesivity, inadequate time of exposure, and the mix/content of lipid in the incubation environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solids are widely identified as a carrier of harmful pollutants in stormwater runoff exerting a significant risk to receiving waters. This paper outlines the findings of an in-depth investigation on heavy metal adsorption to solids surfaces. Pollutant build-up samples collected from sixteen road sites in residential, industrial and commercial land uses were separated into four particle size ranges and analysed for a range of physico-chemical parameters and nine heavy metals including Iron (Fe), Aluminum (Al), Lead (Pb), Zinc (Zn), Cadmium (Cd), Chromium (Cr), Manganese (Mn), Nickel (Ni) and Copper (Cu). High specific surface area (SSA) and total organic carbon (TOC) content in finer particle size ranges was noted, thus confirming strong correlations with heavy metals. Based on their physico-chemical characteristics, two different types of solids originating from traffic and soil sources were identified. Solids generated by traffic were associated with high loads of heavy metals such as Cd and Cr with strong correlation with SSA. This suggested the existence of surface dependent bonds such as cation exchange between heavy metals and solids. In contrast, Fe, Al and Mn which can be attributed to soil inputs showed strong correlation with TOC suggesting strong bonds such as chemsorption. Zn was found to be primarily attached to solids by bonding with the oxides of Fe, Al and Mn. The data analysis also confirmed the predominance of the finer fraction, with 70% of the solids being finer than 150 µm and containing 60% of the heavy metal pollutant load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface coating with an organic self-assembled monolayer (SAM) can enhance surface reactions or the absorption of specific gases and hence improve the response of a metal oxide (MOx) sensor toward particular target gases in the environment. In this study the effect of an adsorbed organic layer on the dynamic response of zinc oxide nanowire gas sensors was investigated. The effect of ZnO surface functionalisation by two different organic molecules, tris(hydroxymethyl)aminomethane (THMA) and dodecanethiol (DT), was studied. The response towards ammonia, nitrous oxide and nitrogen dioxide was investigated for three sensor configurations, namely pure ZnO nanowires, organic-coated ZnO nanowires and ZnO nanowires covered with a sparse layer of organic-coated ZnO nanoparticles. Exposure of the nanowire sensors to the oxidising gas NO2 produced a significant and reproducible response. ZnO and THMA-coated ZnO nanowire sensors both readily detected NO2 down to a concentration in the very low ppm range. Notably, the THMA-coated nanowires consistently displayed a small, enhanced response to NO2 compared to uncoated ZnO nanowire sensors. At the lower concentration levels tested, ZnO nanowire sensors that were coated with THMA-capped ZnO nanoparticles were found to exhibit the greatest enhanced response. ΔR/R was two times greater than that for the as-prepared ZnO nanowire sensors. It is proposed that the ΔR/R enhancement in this case originates from the changes induced in the depletion-layer width of the ZnO nanoparticles that bridge ZnO nanowires resulting from THMA ligand binding to the surface of the particle coating. The heightened response and selectivity to the NO2 target are positive results arising from the coating of these ZnO nanowire sensors with organic-SAM-functionalised ZnO nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topographically and chemically modified titanium implants are recognized to have improved osteogenic properties; however, the molecular regulation of this process remains unknown. This study aimed to determine the microRNA profile and the potential regulation of osteogenic differentiation following early exposure of osteoprogenitor cells to sand-blasted, large-grit acid-etched (SLA) and hydrophilic SLA (modSLA) surfaces. Firstly, the osteogenic characteristics of the primary osteoprogenitor cells were confirmed using ALP activity and Alizarin Red S staining. The effect of smooth (SMO), SLA and modSLA surfaces on the TGF-β/BMP (BMP2, BMP6, ACVR1) and non-canonical WNT/Ca2+ (WNT5A, FZD6) pathways, as well as the integrins ITGB1 and ITGA2, was determined. It was revealed that the modified titanium surfaces could induce the activation of TGF-β/BMP and non-canonical WNT/Ca2+ signaling genes. The expression pattern of microRNAs (miRNAs) related to cell differentiation was evaluated. Statistical analysis of the differentially regulated miRNAs indicated that 35 and 32 miRNAs were down-regulated on the modSLA and SLA surfaces respectively, when compared with the smooth surface (SMO). Thirty-one miRNAs that were down-regulated were common to both modSLA and SLA. There were 10 miRNAs up-regulated on modSLA and nine on SLA surfaces, amongst which eight were the same as observed on modSLA. TargetScan predictions for the down-regulated miRNAs revealed genes of the TGF-β/BMP and non-canonical Ca2+ pathways as targets. This study demonstrated that modified titanium implant surfaces induce differential regulation of miRNAs, which potentially regulate the TGF-β/BMP and WNT/Ca2+ pathways during osteogenic differentiation on modified titanium implant surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicon substrates coated with a bromide-terminated silane are transformed into highly reactive, cyclopentadiene covered analogues. These surfaces undergo rapid cycloaddition reactions with various dienophile-capped polymers. Mild heating of the substrates causes the retro-Diels-Alder reaction to occur, thus reforming the reactive cyclopentadiene surface, generating an efficiently switchable surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nitrile imine-mediated tetrazole-ene cycloaddition reaction (NITEC) is introduced as a powerful and versatile conjugation tool to covalently ligate macromolecules onto variable (bio)surfaces. The NITEC approach is initiated by UV irradiation and proceeds rapidly at ambient temperature yielding a highly fluorescent linkage. Initially, the formation of block copolymers by the NITEC methodology is studied to evidence its efficacy as a macromolecular conjugation tool. The grafting of polymers onto inorganic (silicon) and bioorganic (cellulose) surfaces is subsequently carried out employing the optimized reaction conditions obtained from the macromolecular ligation experiments and evidenced by surface characterization techniques, including X-ray photoelectron spectroscopy and FT-IR microscopy. In addition, the patterned immobilization of variable polymer chains onto profluorescent cellulose is achieved through a simple masking process during the irradiation. Photoinduced nitrile imine-alkene 1,3-dipolar cycloaddition (NITEC) is employed to covalently bind well-defined polymers onto silicon oxide or cellulose. A diaryl tetrazole-functionalized molecule is grafted via silanization or amidification, respectively. Under UV light, a reactive nitrile imine rapidly forms and reacts with maleimide-functionalized polymers yielding a fluorescent linkage. Via a masking method, polymeric fluorescent patterns are achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Argon ions were implanted on titanium discs to study its effect on bone cell adhesion and proli feration. Polished titanium discs were prepared and implanted with argon ions with different doses. Afterwards the samples were sterilized using UV light, inocu lated with human bone cells and incubated. Once fixed and rinsed, image analysis has been used to quantify the number of cells attached to the titanium discs. Cell proliferation tests were also conducted after a period of 120 hours. Cell adhesion was seen to be higher with ion im planted surface. SEM analysis has shown that the cells attached spread more on ion implanted surface. The numbers of cells attached were seen to be higher on implanted surfaces; they tend to occupy wider areas with healthier cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past two decades, flat-plate particle collections have revealed the presence of a remarkable variety of both terrestrial and extraterrestrial material in the stratosphere [1-6]. The ratio of terrestrial to extraterrestrial material and the nature of material collected may vary over observable time scales. Variations in particle number density can be important since the earth’s atmospheric radiation balance, and therefore the earth’s climate, can be influenced by articulate absorption and scattering of radiation from the sun and earth [7-9]. In order to assess the number density of solid particles in the stratosphere, we have examined a representative fraction of the so1id particles from two flat-plate collection surfaces, whose collection dates are separated in time by 5 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of complementary analytical techniques including SEM/EDS, TEM/EDS and conventional optical microscopy has been rigorously applied to precisely defined areas of micrinite in polished coal samples from Australia and New Zealand. Elemental analyses of micrinite regions showed a high abundance of Al, Si and O and high resolution images of micrinite revealed a grain size < 1μm. Electron diffraction and elemental analyses from individual grains within the optically and electron-optically correlated micrinite regions are consistent with the occurence of fine-grained kaolinite. The optical properties of "dark clay" and "micrinite" (i.e. fine-grained kaolinite) can be understood in terms of the diffuse scattering of visible light from the surfaces of materials with different grain sizes in single-phase or multi-phase mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Daylight availability data are essential for designing effectively day lighted buildings. In respect to no available daylight availability data in Iran, illuminance data on the south facing vertical surfaces were estimated using a proper method. Methods: An illuminance measuring set was designed for measuring vertical illuminances for standard times over 15 days at one hour intervals from 9 a.m. to 3 p.m. at three measuring stations (Hamadan, Eshtehard and Kerman). Measuring data were used to confirm predicted by the IESNA method. Results: Measurement of respective illuminances on the south vertical surfaces resulted in minimum values of 10.5 KLx, mean values of 33.59 KLx and maximum values of 79.6 KLx. Conclusion: In this study was developed a regression model between measured and calculated data of south facing vertical illuminance. This model, have a good linear correlation between measured and calculated values (r= 0.892).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The computer is fast becoming part of the furniture in many hospital settings. Increasing reliance on the computer for documentation and dissemination of information in patient-care areas has increased the need to consider this equipment as a potential environmental reservoir for microorganisms. This paper reports on a small experimental study which investigated the potential role of computers in cross-infection. The results indicate that computer surfaces are similar to other environmental surfaces and carry the same risks for cross-infection.