830 resultados para Pneumatice Pressure, Distal Radius Fracture, Dynamic Loading, Fracture Healing
Resumo:
Undernutrition can cause important functional and morphological alterations in the hematopoietic bone marrow (HBM). Degeneration of the HBM in malnourished individuals has been observed in the long bones, but none has been described in the cranial bones. Mandibular condyle fracture can lead to determine nutritional effects due to the high catabolism needed for the bone healing added to the difficulties of mastication. The aim of this study is to describe the histological aspect of HBM in the fractured mandibular condyle and in the temporal bone of malnourished rats. Thirty adult rats suffered unilateral mandibular condyle fracture and were divided into well-nourished (FG) and malnourished (MG) groups. In the MG the animals received a hypoproteic diet during the experiment. Histological sections of the temporomandibular joint were stained to visualize and quantify the HBM in this region at 24h, and 7, 15, 30, and 90 days post-fracture. At 24 hours, FG and MG showed hypocellularity and ischemic degeneration in the mandibular condyle and in the temporal bone. At 7 days, FG exhibited high cellularity in comparison with MG in the condyle; the temporal bone of both groups presented hypocellularity and degeneration. At 30 and 90 days, FG exhibited similar characteristics to those of the control; MG maintained the degeneration level mainly in the temporal bone. Malnutrition prejudices the regeneration of the HBM during a fracture healing in the temporomandibular joint. This fact contributes to a complete modification of the bone structure as well as to an impairment of the healing process.
Resumo:
OBJECTIVES This study was designed to assess effects of cholinergic stimulation using acetylcholinesterase inhibitors (AChEIs), a group of drugs that stimulate cholinergic receptors and are used to treat Alzheimer's disease (AD), on healing of hip fractures. METHODS A retrospective cohort study was performed using 46-female AD patients, aged above 75 years, who sustained hip fractures. Study analyses included the first 6-months after hip fracture fixation procedure. Presence of AChEIs was used as predictor variable. Other variables that could affect study outcomes: age, body mass index (BMI), mental state or type of hip fracture, were also included. Radiographic union at fracture site (Hammer index), bone quality (Singh index) and fracture healing complications were recorded as study outcomes. The collected data was analyzed by student's-t, Mann-Whitney-U and chi-square tests. RESULTS No significant differences in age, BMI, mental state or type of hip fracture were observed between AChEIs-users and nonusers. However, AChEIs-users had better radiographic union at the fracture site (relative risk (RR),2.7; 95%confidence interval (CI),0.9-7.8), better bone quality (RR,2.0; 95%CI,1.2-3.3) and fewer healing complications (RR,0.8; 95%CI,0.7-1.0) than nonusers. CONCLUSION In elderly female patients with AD, the use of AChEIs might be associated with an enhanced fracture healing and minimized complications.
Resumo:
OBJECTIVES: Renal tubular sodium handling was measured in healthy subjects submitted to acute and chronic salt-repletion/salt-depletion protocols. The goal was to compare the changes in proximal and distal sodium handling induced by the two procedures using the lithium clearance technique. METHODS: In nine subjects, acute salt loading was obtained with a 2 h infusion of isotonic saline, and salt depletion was induced with a low-salt diet and furosemide. In the chronic protocol, 15 subjects randomly received a low-, a regular- and a high-sodium diet for 1 week. In both protocols, renal and systemic haemodynamics and urinary electrolyte excretion were measured after an acute water load. In the chronic study, sodium handling was also determined, based on 12 h day- and night-time urine collections. RESULTS: The acute and chronic protocols induced comparable changes in sodium excretion, renal haemodynamics and hormonal responses. Yet, the relative contribution of the proximal and distal nephrons to sodium excretion in response to salt loading and depletion differed in the two protocols. Acutely, subjects appeared to regulate sodium balance mainly by the distal nephron, with little contribution of the proximal tubule. In contrast, in the chronic protocol, changes in sodium reabsorption could be measured both in the proximal and distal nephrons. Acute water loading was an important confounding factor which increased sodium excretion by reducing proximal sodium reabsorption. This interference of water was particularly marked in salt-depleted subjects. CONCLUSION: Acute and chronic salt loading/salt depletion protocols investigate different renal mechanisms of control of sodium balance. The endogenous lithium clearance technique is a reliable method to assess proximal sodium reabsorption in humans. However, to investigate sodium handling in diseases such as hypertension, lithium should be measured preferably on 24 h or overnight urine collections to avoid the confounding influence of water.
Resumo:
The morbidity of bone graft harvesting from the iliac crest has been widely discussed in the literature. For some authors, it is considered to be low and for others relatively high. We report on a case of a fracture of the iliac wing after graft harvesting from the anterior iliac crest despite good surgical technique. This complication is well known and most of these fractures heal uneventfully if treated conservatively. However, if anatomical and technical considerations are respected, the patient could be spared this inconvenience. Based on a literature review, we discuss the procedure's potential complications and how to avoid them in an update.
Resumo:
A Strontium ranelate appears to influence more than alendronate distal tibia bone microstructure as assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT), and biomechanically relevant parameters as assessed by micro-finite element analysis (mu FEA), over 2 years, in postmenopausal osteoporotic women.Introduction Bone microstructure changes are a target in osteoporosis treatment to increase bone strength and reduce fracture risk.Methods Using HR-pQCT, we investigated the effects on distal tibia and radius microstructure of strontium ranelate (SrRan; 2 g/day) or alendronate (70 mg/week) for 2 years in postmenopausal osteoporotic women. This exploratory randomized, double-blind trial evaluated HR-pQCT and FEA parameters, areal bone mineral density (BMD), and bone turnover markers.Results In the intention-to-treat population (n = 83, age: 64 +/- 8 years; lumbar T-score: -2.8 +/- 0.8 [DXA]), distal tibia Cortical Thickness (CTh) and Density (DCort), and cancellous BV/TV increased by 6.3%, 1.4%, and 2.5%, respectively (all P < 0.005), with SrRan, but not with alendronate (0.9%, 0.4%, and 0.8%, NS) (P < 0.05 for all above between-group differences). Difference for CTh evaluated with a distance transformation method was close to significance (P = 0.06). The estimated failure load increased with SrRan (+2.1%, P < 0.005), not with alendronate (-0.6%, NS) (between-group difference, P < 0.01). Cortical stress was lower with SrRan (P < 0.05); both treatments decreased trabecular stress. At distal radius, there was no between-group difference other than DCort (P < 0.05). Bone turnover markers decreased with alendronate; bALP increased (+21%) and serum-CTX-I decreased (-1%) after 2 years of SrRan (between-group difference at each time point for both markers, P < 0.0001). Both treatments were well tolerated.Conclusions Within the constraints of HR-pQCT method, and while a possible artefactual contribution of strontium cannot be quantified, SrRan appeared to influence distal tibia bone microstructure and FEA-determined biomechanical parameters more than alendronate. However, the magnitude of the differences is unclear and requires confirmation with another method.
Resumo:
Nonunion of anterior tibial spine of tibia in children is quite rare, but it could be associated with significant instability of the knee as it involves the fixation of anterior cruciate ligament. We report one case in which open reduction and internal fixation was carried out with good functional results. A literature review was performed to identify the cases reported of tibial eminence nonunion in children.
Resumo:
Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.
Resumo:
Background: Screening for osteoporosis is important in older patients admitted to post-acute rehabilitation. However, DXA measurement is sometimes difficult to perform because of difficulties in positioning the patient and artefacts (osteoarthritis, prosthesis). The objectives were to determine the prevalence of unknown clinical osteoporosis in rehab patients and to determine new strategies for identifying clinical osteoporosis in this population. Method: Over a 9-months period, patients consecutively admitted to post-acute rehabilitation were included in th stdy. Patients with osteoporosis diagnosis, and those with terminal illness or severe physical limitations were excluded. Patients underwent Bone Mineral Density (BMD) by DXA and Vertebral Fracture Assessment (VFA). Clinical osteoporosis was defined as BMD ≤-2.5 SD at any site (lumbar spine, femoral neck, total hip or distal radius), ≥1 vertebral fracture, ≥1 hip fracture, or another fragility fracture and BMD ≤-2 SD. Results: Overall, 102 (17.0%) of the 600 patients admitted to rehab refused to participate in the study or were unable to consent. Among the 498 remaining patients, 99 (19.9%) were excluded because of already known diagnosis of osteoporosis, 101 (20.3%) were excluded because of terminal illness, severe physical limitations, and 45 (9.0%) because of inability to perform DXA during the stay (death, hospital transfer). Overall, 253 patients were assessed with DXA and VFA (166 women, mean age 83±7 years, mean BMI 27±6 kg/m2, and 87 men, mean age 82±6 yrs, mean BMI 27±5 kg/m2). Of these, 70% had history of fall during the last 6 months and 9.1% had hip fracture history. Prevalence of osteoporotic vertebral fracture was 36% in women and 32% in men. Overall, 152 (60.1%) patients had clinical osteoporosis (women: 67%; men: 46%) according to above criteria. Hip fracture history and vertebral fracture assessment identified correctly 105 (69.1%) of these 152 patients. Conclusion: A high prevalence of osteoporosis was observed in this population of rehab patients. Osteoporosis status should be systematically assessed in these patients at high fall risk, at least with careful history of hip fracture and an assessment for vertebral fractures with spine X-ray.
Resumo:
A closed fracture was performed on the left tibia of 3-month-old Wistar rats weighing 250 to 350 g that were either healthy (N = 24) or made diabetic with alloxan (N = 24) to investigate the effect of alloxan-induced diabetes on the course of bone fracture healing. Histomorphometric analysis of the fracture site was performed at 7, 14, 25, and 35 days. After 7 days, diabetic rats had significantly less cartilage (P = 0.045) and greater fibrous connective (P = 0.006) tissue formation at the fracture site compared to controls. In contrast, marked callus formation was seen in diabetic rats with significant osteogenesis (P = 0.011, P = 0.010, P = 0.010, respectively, for 14, 25, and 35 days) and chondrogenesis (P = 0.028, P = 0.033, P = 0.019) compared to controls. Radiographic analysis revealed a displaced fracture with poor bone fragment alignment and delayed consolidation at these times in the diabetic group. The levels of alkaline phosphatase were significantly higher in diabetic rats at 25 days (P = 0.009). These results suggest that the initial excessive formation of fibrous connective tissue associated with delay in chondrogenesis and osteogenesis may not provide suitable stability of the fractured site, contributing to the inappropriate alignment of fragments and an increase in the volume of callus in later stages of repair. The resulting displaced fracture in diabetic rats requires long periods for remodeling and complete bone consolidation.
Resumo:
This work is an example of the improvement on quantitative fractography by means of digital image processing and light microscopy. Two techniques are presented to investigate the quantitative fracture behavior of Ti-4Al-4V heat-treated alloy specimens, under Charpy impact testing. The first technique is the Minkowski method for fractal dimension measurement from surface profiles, revealing the multifractal character of Ti-4Al-4V fracture. It was not observed a clear positive correlation of fractal values against Charpy energies for Ti-4Al-4V alloy specimens, due to their ductility, microstructural heterogeneities and the dynamic loading characteristics at region near the V-notch. The second technique provides an entire elevation map of fracture surface by extracting in-focus regions for each picture from a stack of images acquired at successive focus positions, then computing the surface roughness. Extended-focus reconstruction has been used to explain the behavior along fracture surface. Since these techniques are based on light microscopy, their inherent low cost is very interesting for failure investigations.
Resumo:
An adult female free-ranging six-banded armadillo (Euphractus sexcinctus) was presented with an inverted L-shaped fracture of the left pectoral carapace. The fracture was stabilized with the use of three simple interrupted interfragmentary sutures of 2-0 nylon. After 7 days, wound dehiscence occurred, so sutures were replaced and the wound treated topically with castor bean oil cream. Healing of the fracture was observed after 14 days of this treatment.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Unstable distal femoral fractures in children are challenging lesions with restricted surgical options for adequate stabilization. Elastic nails have become popular for treating femoral shaft fractures, yet they are still challenging for using in distal fractures. The aim of this study was to test whether end caps (CAP) inserted into the nail extremity improved the mechanical stabilization of a segmental defect at the distal femoral metaphyseal-diaphyseal junction created in an artificial pediatric bone model. Methods: Two 3.5-mm titanium elastic nails (TEN) were introduced intramedullary into pediatric femur models, and a 7.0-mm-thick segmental defect was created at the distal diaphyseal-metaphyseal junction. Nondestructive 4-point bending, axial-bending, and torsion tests were conducted. After this, the end caps were inserted into the external tips of the nails and then screwed into the bone cortex. The mechanical tests were repeated. Stiffness, displacement, and torque were analyzed using the Wilcoxon nonparametric test for paired samples. Results: In the combined axial-bending tests, the TEN + CAP combination was 8.75% stiffer than nails alone (P < 0.01); in torsion tests, the TEN + CAP was 14% stiffer than nails alone (P < 0.01). In contrast, the 4-point bending test did not show differences between the methods (P = 0.91, stiffness; P = 0.51, displacement). Thus, the end caps contributed to an increase in the construct stability for torsion and axial-bending forces but not for 4-point bending forces. Conclusions: These findings indicate that end caps fitted to elastic nails may contribute to the stabilization of fractures that our model mimics (small distal fragment, bone comminution, and distal bone fragment loss).
Resumo:
Compared with other mature engineering disciplines, fracture mechanics of concrete is still a developing field and very important for structures like bridges subject to dynamic loading. An historical point of view of what done in the field is provided and then the project is presented. The project presents an application of the Digital Image Correlation (DIC) technique for the detection of cracks at the surface of concrete prisms (500mmx100mmx100mm) subject to flexural loading conditions (Four Point Bending test). The technique provide displacement measurements of the region of interest and from this displacement field information about crack mouth opening (CMOD) are obtained and related to the applied load. The evolution of the fracture process is shown through graphs and graphical maps of the displacement at some step of the loading process. The study shows that it is possible with the DIC system to detect the appearance and evolution of cracks, even before the cracks become visually detectable.
Resumo:
OBJECTIVE: To report clinical evaluation of the clamp rod internal fixator 4.5/5.5 (CRIF 4.5/5.5) in bovine long-bone fracture repair. STUDY DESIGN: Retrospective study. ANIMALS: Cattle (n=22) with long-bone fractures. METHODS: Records for cattle with long-bone fractures repaired between 1999 and 2004 with CRIF 4.5/5.5 were reviewed. Quality of fracture repair, fracture healing, and clinical outcome were investigated by means of clinical examination, medical records, radiographs, and telephone questionnaire. RESULTS: Successful long-term outcome was achieved in 18 cattle (82%); 4 were euthanatized 2-14 days postoperatively because of fracture breakdowns. Two cattle had movement of clamps on the rod. Moderate to severe callus formation was evident in 11 cattle 6 months postoperatively. CONCLUSIONS: Movement of clamps on the rod was recognized as implant failure unique to the CRIF. This occurred in cattle with poor fracture stability because of an extensive cortical defect. The CRIF system may not be ideal to treat metacarpal/metatarsal fractures because its voluminous size makes skin closure difficult, thereby increasing the risk of postoperative infections. CLINICAL RELEVANCE: CRIF cannot be recommended for repair of complicated long-bone fractures in cattle.