214 resultados para Pm10


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar a associação entre exposição diária à poluição do ar e função respiratória de escolares. MÉTODOS: Estudo de painel com uma amostra aleatória de 118 escolares (seis a 15 anos de idade) da rede pública do Rio de Janeiro (RJ), residentes até 2 km do local do estudo. Dados sobre características das crianças foram obtidos por questionário, incluindo o International Study of Asthma and Allergies in Childhood. Exames diários de pico de fluxo foram realizados para medir a função respiratória. Dados diários dos níveis de PM10, SO2, O3, NO2 e CO, temperatura e umidade foram fornecidos por um monitor móvel. As medidas repetidas de função respiratória foram associadas aos níveis dos poluentes por meio de modelo multinível ajustado por tendência temporal, temperatura, umidade do ar, exposição domiciliar ao fumo, ser asmático, altura, sexo, peso e idade das crianças. RESULTADOS: O pico de fluxo expiratório médio foi 243,5 l/m (dp=58,9). A menor média do pico de fluxo expiratório foi 124 l/m e a maior 450 l/m. Para o aumento de 10 µg/m³ de PM10 houve uma diminuição de 0,34 l/min na média do pico de fluxo no terceiro dia. Para o aumento de 10 µg/m³ de NO2 houve uma diminuição entre 0,23 l/min a 0,28 l/min na média do pico de fluxo após a exposição. Os efeitos do CO e do SO2 no pico de fluxo dos escolares não foram estatisticamente significativos. O O3 apresentou um resultado protetor: o aumento de 10 µg/m³ de O3 estaria associado, um dia depois da exposição, a aumento de 0,2 l/min na média da função respiratória. CONCLUSÕES: Mesmo dentro de níveis aceitáveis na maior parte do período, a poluição atmosférica, principalmente o PM10 e o NO2, esteve associada à diminuição da função respiratória de crianças residentes no Rio de Janeiro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho foi realizado no âmbito da disciplina de Dissertação/Estágio do ramo de Optimização Energética na Indústria Química, do Mestrado em Engenharia Química do Instituto Superior de Engenharia do Porto e foi desenvolvido na empresa GreenWatt. O principal objectivo é efectuar uma auditoria energética e uma auditoria QAI a uma clínica de fisiatria de forma a preparar as ferramentas necessárias para a Certificação Energética e da QAI no enquadramento do Sistema de Certificação Energética. Na auditoria QAI foram analisados parâmetros físicos - temperatura, humidade relativa e partículas respiráveis PM10, parâmetros químicos - CO2, CO, O3, COVs, HCOH e o radão, e ainda parâmetros microbiológicos - bactérias, fungos e legionella. Na auditoria energética foi feita a caracterização dos vectores de energia utilizados no edifício, nomeadamente, gás natural e electricidade. Para esta caracterização efectuou-se um levantamento de toda a informação disponível relativa aos combustíveis utilizados, iluminação instalada, outros equipamentos consumidores de energia e perfis de utilização. Com recurso a analisadores de energia foram ainda medidos os consumos eléctricos do edifício. Com suporte nos dados provenientes da auditoria energética e das facturas anuais efectuou-se a validação da simulação dinâmica do edifício. Esta simulação é a base do cálculo do IEEnominal do edifício. Os resultados da auditoria QAI, permitiram verificar que existem valores nãoregulamentares em relação aos compostos orgânicos voláteis, fungos e bactérias. Da auditoria energética concluiu-se que o principal consumo de energia é o gás natural utilizado pelas caldeiras existentes. Este valor representa cerca de 81% do consumo total de energia, reproduzindo os mesmos resultados obtidos pela desagregação das facturas energéticas. No que respeita à electricidade concluiu-se que as bombas de água e os equipamentos eléctricos são os maiores consumidores deste vector, com, respectivamente, 53% e 23% do consumo total de energia eléctrica. Após a realização da simulação dinâmica, com base nos levantamentos realizados no edifício e na auditoria energética efectuada, obteve-se uma fotografia do edifício no que respeita ao seu desempenho energético, e calculou-se um IEEnominal de 40,54 kgep/m2.ano o que qualifica o edifício com uma Classe Energética E. O valor de CO2 emitido por este edifício em termos nominais, anualmente, é de 76,39 toneladas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 μm2/cm3. The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Social concerns for environmental impact on air, water and soil pollution have grown along with the accelerated growth of pig production. This study intends to characterize air contamination caused by fungi and particles in swine production, and, additionally, to conclude about their eventual environmental impact. Fiftysix air samples of 50 litters were collected through impaction method. Air sampling and particle matter concentration were performed in indoor and also outdoor premises. Simultaneously, temperature and relative humidity were monitored according to the International Standard ISO 7726 – 1998. Aspergillus versicolor presents the highest indoor spore counts (>2000 CFU/m3) and the highest overall prevalence (40.5%), followed by Scopulariopsis brevicaulis (17.0%) and Penicillium sp. (14.1%). All the swine farms showed indoor fungal species different from the ones identified outdoors and the most frequent genera were also different from the ones indoors. The distribution of particle size showed the same tendency in all swine farms (higher concentration values in PM5 and PM10 sizes). Through the ratio between the indoor and outdoor values, it was possible to conclude that CFU/m3 and particles presented an eventual impact in outdoor measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As polycyclic aromatic hydrocarbons (PAHs) have a negative impact on human health due to their mutagenic and/or carcinogenic properties, the objective of this work was to study the influence of tobacco smoke on levels and phase distribution of PAHs and to evaluate the associated health risks. The air samples were collected at two homes; 18 PAHs (the 16 PAHs considered by U.S. EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) were determined in gas phase and associated with thoracic (PM10) and respirable (PM2.5) particles. At home influenced by tobacco smoke the total concentrations of 18 PAHs in air ranged from 28.3 to 106 ngm 3 (mean of 66.7 25.4 ngm 3),∑PAHs being 95% higher than at the non-smoking one where the values ranged from 17.9 to 62.0 ngm 3 (mean of 34.5 16.5 ngm 3). On average 74% and 78% of ∑PAHs were present in gas phase at the smoking and non-smoking homes, respectively, demonstrating that adequate assessment of PAHs in air requires evaluation of PAHs in both gas and particulate phases. When influenced by tobacco smoke the health risks values were 3.5e3.6 times higher due to the exposure of PM10. The values of lifetime lung cancer risks were 4.1 10 3 and 1.7 10 3 for the smoking and nonsmoking homes, considerably exceeding the health-based guideline level at both homes also due to the contribution of outdoor traffic emissions. The results showed that evaluation of benzo[a]pyrene alone would probably underestimate the carcinogenic potential of the studied PAH mixtures; in total ten carcinogenic PAHs represented 36% and 32% of the gaseous ∑PAHs and in particulate phase they accounted for 75% and 71% of ∑PAHs at the smoking and non-smoking homes, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air pollution represents a serious risk not only to environment and human health, but also to historical heritage. In this study, air pollution of the Oporto Metropolitan Area and its main impacts were characterized. The results showed that levels of CO, PM10 and SO2 have been continuously decreasing in the respective metropolitan area while levels of NOx and NO2 have not changed significantly. Traffic emissions were the main source of the determined polycyclic aromatic hydrocarbons (PAHs; 16 PAHs considered by U.S. EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in air of the respective metropolitan area. The mean concentration of 18 PAHs in air was 69.9±39.7 ng m−3 with 3–4 rings PAHs accounting for 75% of the total ΣPAHs. The health risk analysis of PAHs in air showed that the estimated values of lifetime lung cancer risks considerably exceeded the health-based guideline level. Analytical results also confirm that historical monuments in urban areas act as passive repositories for air pollutants present in the surrounding atmosphere. FTIR and EDX analyses showed that gypsum was the most important constituent of black crusts of the characterized historical monument Monastery of Serra do Pilar classified as “UNESCO World Cultural Heritage”. In black crusts, 4–6 rings compounds accounted approximately for 85% of ΣPAHs. The diagnostic ratios confirmed that traffic emissions were the major source of PAHs in black crusts; PAH composition profiles were very similar for crusts and PM10 and PM2.5.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives - This study intended to characterize work environment contamination by particles in 2 waste-sorting plants. Material and Methods - Particles were measured by portable direct-reading equipment. Besides mass concentration in different sizes, data related with the number of particles concentration were also obtained. Results - Both sorting units showed the same distribution concerning the 2 exposure metrics: particulate matter 5 (PM5) and particulate matter 10 (PM10) reached the highest levels and 0.3 μm was the fraction with a higher number of particles. Unit B showed higher (p < 0.05) levels for both exposure metrics. For instance, in unit B the PM10 size is 9-fold higher than in unit A. In unit A, particulate matter values obtained in pre-sorting and in the sequential sorting cabinet were higher without ventilation working. Conclusions - Workers from both waste-sorting plants are exposed to particles. Particle counting provided additional information that is of extreme value for analyzing the health effects of particles since higher values of particles concentration were obtained in the smallest fraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because polycyclic aromatic hydrocarbons (PAHs) have been proven to be toxic, mutagenic, and/or carcinogenic, there is widespread interest in analyzing and evaluating exposure to PAHs in atmospheric environments influenced by different emission sources. Because traffic emissions are one of the biggest sources of fine particles, more information on carcinogenic PAHs associated with fine particles needs to be provided. Aiming to further understand the impact of traffic particulate matter (PM) on human health, this study evaluated the influence of traffic on PM10 (PM with aerodynamic diameter <10 µm) and PM2.5 (PM with aerodynamic diameter <2.5 µm), considering their concentrations and compositions in carcinogenic PAHs. Samples were collected at one site influenced by traffic emissions and at one reference site using lowvolume samplers. Analysis of PAHs was performed by microwave-assisted extraction combined with liquid chromatography (MAE-LC); 17 PAHs, including 9 carcinogenic ones, were quantified. At the site influenced by traffic emissions, PM10 and PM2.5 concentrations were, respectively, 380 and 390% higher than at the background site. When influenced by traffic emissions, the total concentration of nine carcinogenic compounds (naphthalene, chrysene, benzo(a)anthracene, benzo(b) fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, and dibenzo(a,l)pyrene) was increased by 2400 and 3000% in PM10 and PM2.5, respectively; these nine carcinogenic compounds represented 68 and 74% of total PAHs (ƩPAHs) for PM10 and PM2.5, respectively. All PAHs, including the carcinogenic compounds, were mainly present in fine particles. Considering the strong influence of these fine particles on human health, these conclusions are relevant for the development of strategies to protect public health.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg m−3 and 8.2±4.9 μg m−3, and 17±13 μg m−3 and 7.3±5.9 μg m−3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ngm−3, surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10−6) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98×10−7 in PM10 and 1.06×10−6 in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O projeto “Avaliação da Exposição a Fungos e Partículas em Explorações Avícolas e Suinícolas” contemplou um elevado número de colheitas ambientais e biológicas e respectivo processamento laboratorial, sendo apenas possível a sua concretização graças ao financiamento disponibilizado pela Autoridade para as Condições de Trabalho. Foi realizado um estudo transversal para avaliar a contaminação causada por fungos e partículas em 7 explorações avícolas e 7 explorações suinícolas. No que concerne à monitorização biológica, foram medidos os parâmetros espirométricos, utilizando o espirómetro MK8 Microlab, avaliada a existência de sintomas clínicos associados com a asma e outras doenças alérgicas, através de questionário adaptado European Community Respiratory Health Survey e, ainda, avaliada a sensibilização aos agentes fúngicos (IgE). Foram ainda adicionados dois objetivos ao estudo, designadamente: aferir a existência de três espécies/estirpes potencialmente patogénicas/toxinogénicas com recurso à biologia molecular e avaliar a exposição dos trabalhadores à micotoxina aflatoxina B1 por recurso a indicador biológico de exposição. Foram colhidas 27 amostras de ar de 25 litros nas explorações avícolas e 56 de 50 litros nas explorações suinícolas através do método de impacto. As colheitas de ar e a medição da concentração das partículas foram realizadas no interior e no exterior dos pavilhões, sendo este último considerado como local de referência. Simultaneamente, a temperatura e a humidade relativa também foram registadas. As colheitas das superfícies foram realizadas através da técnica de zaragatoa, tendo sido utilizado um quadrado de metal inoxidável de 10 cm de lado, de acordo com a International Standard ISO 18593 – 2004. As zaragatoas obtidas (20 das explorações avícolas e 48 das explorações suinícolas) foram inoculadas em malte de extract agar (2%) com cloranfenicol (0,05 g/L). Além das colheitas de ar e de superfícies, foram também obtidas colheitas da cama das explorações avícolas (7 novas e 14 usadas) e da cobertura do pavimento das explorações suinícolas (3 novas e 4 usadas) e embaladas em sacos esterilizados. Cada amostra foi diluída e inoculada em placas contendo malte extract agar. Todas as amostras foram incubadas a 27,5ºC durante 5 a 7 dias e obtidos resultados quantitativos (UFC/m3; UFC/m2; UFC/g) e qualitativos com a identificação das espécies fúngicas. Para a aplicação dos métodos de biologia molecular foram realizadas colheitas de ar de 300 litros utilizando o método de impinger com a velocidade de recolha de 300 L/min. A identificação molecular de três espécies potencialmente patogénicas e/ou toxinogénicas (Aspergillus flavus, Aspergillus fumigatus e Stachybotrys chartarum) foram obtidas por PCR em tempo real (PCR TR) utilizando o Rotor-Gene 6000 qPCR Detection System. As medições de partículas foram realizadas por recurso a equipamento de leitura direta (modelo Lighthouse, 2016 IAQ). Este recurso permitiu medir a concentração (mg/m3) de partículas em 5 dimensões distintas (PM 0.5; PM 1.0; PM 2.5; PM 5.0; PM10). Nas explorações avícolas, 28 espécies/géneros de fungos foram isolados no ar, tendo Aspergillus versicolor sido a espécie mais frequente (20.9%), seguida por Scopulariopsis brevicaulis (17.0%) e Penicillium sp. (14.1%). Entre o género Aspergillus, Aspergillus flavus apresentou o maior número de esporos (>2000 UFC/m3). Em relação às superfícies, A. versicolor foi detetada em maior número (>3 × 10−2 UFC/m2). Na cama nova, Penicillium foi o género mais frequente (59,9%), seguido por Alternaria (17,8%), Cladosporium (7,1%) e Aspergillus (5,7%). Na cama usada, Penicillium sp. foi o mais frequente (42,3%), seguido por Scopulariopsis sp. (38,3%), Trichosporon sp. (8,8%) e Aspergillus sp. (5,5%). Em relação à contaminação por partículas, as partículas com maior dimensão foram detectadas em maiores concentrações, designadamente as PM5.0 (partículas com a dimensão de 5.0 bm ou menos) e PM10 (partículas com a dimensão de 10 bm ou menos). Neste setting a prevalência da alteração ventilatória obstrutiva foi superior nos indivíduos com maior tempo de exposição (31,7%) independentemente de serem fumadores (17,1%) ou não fumadores (14,6%). Relativamente à avaliação do IgE específico, foi apenas realizado em trabalhadores das explorações avícolas (14 mulheres e 33 homens), não tendo sido encontrada associação positiva (p<0.05%) entre a contaminação fúngica e a sensibilização a antigénios fúngicos. No caso das explorações suinícolas, Aspergillus versicolor foi a espécie mais frequente (20,9%), seguida por Scopulariopsis brevicaulis (17,0%) e Penicillium sp. (14,1%). No género Aspergillus, A. versicolor apresentou o maior isolamento no ar (>2000 UFC/m3) e a maior prevalência (41,9%), seguida por A. flavus e A. fumigatus (8,1%). Em relação às superfícies analisadas, A. versicolor foi detetada em maior número (>3 ×10−2 UFC/m2). No caso da cobertura do pavimento das explorações suinícolas, o género Thicoderma foi o mais frequente na cobertura nova (28,0%) seguida por A. versicolor e Acremonium sp. (14,0%). O género Mucor foi o mais frequente na cobertura usada (25,1%), seguido por Trichoderma sp. (18,3%) e Acremonium sp. (11,2%). Relativamente às partículas, foram evidenciados também valores mais elevados na dimensão PM5 e, predominantes nas PM10. Neste contexto, apenas 4 participantes (22,2%) apresentaram uma alteração ventilatória obstrutiva. Destes, as obstruções mais graves encontraram-se nos que também apresentavam maior tempo de exposição. A prevalência de asma na amostra de trabalhadores em estudo, pertencentes aos 2 contextos em estudo, foi de 8,75%, tendo-se verificado também uma prevalência elevada de sintomatologia respiratória em profissionais não asmáticos. Em relação à utilização complementar dos métodos convencionais e moleculares, é recomendável que a avaliação da contaminação fúngica nestes settings, e, consequentemente, a exposição profissional a fungos, seja suportada pelas duas metodologias e, ainda, que ocorre exposição ocupacional à micotoxina aflatoxina B1 em ambos os contextos profissionais. Face aos resultados obtidos, é importante salientar que os settings alvo de estudo carecem de uma intervenção integrada em Saúde Ocupacional no âmbito da vigilância ambiental e da vigilância da saúde, com o objetivo de diminuir a exposição aos dois factores de risco estudados (fungos e partículas).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Particulate matter (PM) can have a significant impact on human health and on artifacts stored and kept inside museums and archives. To the author's knowledge, its immediate and/or longterm concentrations and distribution on Portuguese archives has never been determined. Four Portuguese archives (with and without HVAC/air filtration systems) were selected and the immediate concentration of airborne particulate matter was measured by active sampling. Indoor-outdoor ratios were also determined. International and national guidelines were used to ascertain the environment’s quality, both for the readers and staff and for the documents preserved in these institutions. Inside, PM2.5 ranged between 0.37μg/m3 and 27.61μg/m3, while PM10 ranged between 4.43μg/m3 and 285.52μg/m3. The lowest values were determined in storage rooms and the highest in reading rooms. In terms of human health, Portuguese guidelines for immediate PM10 concentration were not met in several locations. For conservation purposes, storage rooms were classified according to an original air quality grid. Air filtration systems proved valuable in maintaining a safe environment for our written heritage and the staff and readers that deal with it and care for it every day. This study constitutes the first snapshot of the particulate matter concentrations and distribution in Portuguese Archives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyze the association between concentrations of air pollutants and admissions for respiratory causes in children. METHODS Ecological time series study. Daily figures for hospital admissions of children aged < 6, and daily concentrations of air pollutants (PM10, SO2, NO2, O3 and CO) were analyzed in the Região da Grande Vitória, ES, Southeastern Brazil, from January 2005 to December 2010. For statistical analysis, two techniques were combined: Poisson regression with generalized additive models and principal model component analysis. Those analysis techniques complemented each other and provided more significant estimates in the estimation of relative risk. The models were adjusted for temporal trend, seasonality, day of the week, meteorological factors and autocorrelation. In the final adjustment of the model, it was necessary to include models of the Autoregressive Moving Average Models (p, q) type in the residuals in order to eliminate the autocorrelation structures present in the components. RESULTS For every 10:49 μg/m3 increase (interquartile range) in levels of the pollutant PM10 there was a 3.0% increase in the relative risk estimated using the generalized additive model analysis of main components-seasonal autoregressive – while in the usual generalized additive model, the estimate was 2.0%. CONCLUSIONS Compared to the usual generalized additive model, in general, the proposed aspect of generalized additive model − principal component analysis, showed better results in estimating relative risk and quality of fit.