978 resultados para Plantar pressures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seismic passive earth pressure coefficients were computed by the method of limit equilibrium using a pseudostatic approach for seismic forces. Composite curved rupture surfaces were considered in the analysis. While earlier studies using this type of analysis were mainly for sands, seismic passive earth pressure coefficients were obtained in the present study considering the effects of cohesion, surcharge, and own weight. The minimum seismic passive force was obtained by adding the individual minimum values of these components and the validity of the principle of superposition was examined. Other parameters considered in the analysis were wall batter angle, ground surface slope, soil friction angle, wall friction angle, wall adhesion to soil cohesion ratio, and horizontal and vertical seismic accelerations. The seismic earth pressure coefficients were found to be highly sensitive to the seismic acceleration coefficients both in the horizontal and vertical directions. Results of the study are presented in the form of figures and tables. Comparisons of the proposed method with available theories in the seismic case are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vapor-liquid equilibrium data for the system n-heptane-n-butyl alcohol at pressures of 1445, 2205, 2965, and 3725 mm. of Hg have been reported. The data are correlated with Chao's modified Redlich-Kister equation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vapor-liquid equilibrium data for the systems diisopropyl ether-n-heptane and diisopropyl ether-carbon tetrachloride have been reported at pressures of 760, 1520, and 2280 mm. of Hg. The systems form ideal mixtures under the pressure range studied.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of the gap breakdown voltage characteristic at a low pressure of 7×10-5 Torr with a standard (1/50)-μsec impulse-voltage wave reveals an agreement with the criterion Vb=Cd0.5 suggested by Cranberg. Voltage-time-to-breakdown characteristics has also been determined. From these studies, it is concluded that impulse breakdown in vacuum is initiated by an electron current heating an anode spot and thereby liberating a clump which causes breakdown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the elastic behaviour of matter when subjected to very large pressures, such as occur for example in the interior of the earth, and to provide an explanation for phenomena like earthquakes, it is essential to be able to calculate the values of the elastic constants of a substance under a state of large initial stress in terms of the elastic constants of a natural or stress-free state. An attempt has been made in this paper to derive expressions for these quantities for a substance of cubic symmetry on the basis of non-linear theory of elasticity and including up to cubic powers of the strain components in the strain energy function. A simple method of deriving them directly from the energy function itself has been indicated for any general case and the same has been applied to the case of hydrostatic compression. The notion of an effective elastic energy-the energy require to effect an infinitesimal deformation over a state of finite strain-has been introduced, the coefficients in this expression being the effective elastic constants. A separation of this effective energy function into normal co-ordinates has been given for the particular case of cubic symmetry and it has been pointed out, that when any of such coefficients in this normal form becomes negative, elastic instability will set in, with associated release of energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental studies are presented to show the effect of thermal stresses on thermal contact conductance (TCC) at low contact pressures. It is observed that in a closed contact assembly, contact pressure acting on the interface changes with the changing temperature of contact members. This change in contact pressure consequently causes variations in the TCC of the junction. A relationship between temperature change and the corresponding magnitude of developed thermal stress in a contact assembly is determined experimentally. Inclusion of a term called temperature dependent load correction factor is suggested in the theoretical model for TCC to make it capable of predicting TCC values more accurately in contact assemblies that experience large temperature fluctuations. [DOI: 10.1115/1.4001615]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vapour pressures of barium and strontium have been measured by continuous monitoring of the weight loss of Knudsen cells in the temperature range 700�1200 K. The results for strontium agree with those reported in the literature, but the vapour pressure of barium has been found to be considerably lower than the generally accepted value. The experimentally determined pressures are in good agreement with theoretical values obtained using the Gibbs-Bogoliubov first-order variational method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Details of a simple and convenient high-pressure cell for continuous-wave, wide-line nuclear magnetic resonance investigation at high pressures and low temperatures are described. Experimental results obtained with the cell at 14*108 Pa and 77K for ammonium iodide are presented briefly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal contact conductance (TCC) measurements are made on bare and gold plated (<= 0.5 mu m) oxygen free high conductivity (OFHC) Cu and brass contacts in vacuum, nitrogen, and argon environments. It is observed that the TCC in gaseous environment is significantly higher than that in vacuum due to the enhanced thermal gap conductance. It is found that for a given contact load and gas pressure, the thermal gap conductance for bare OFHC Cu contacts is higher than that for gold plated contacts. It is due to the difference in the molecular weights of copper and gold, which influences the exchange of kinetic energy between the gas molecules and contact surfaces. Furthermore, the gap conductance is found to increase with increasing thickness of gold plating. Topography measurements and scanning electron microscopy (SEM) analysis of contact surfaces revealed that surfaces become smoother with increasing gold plating thickness, thus resulting in smaller gaps and consequently higher gap conductance. (C) 2010 Elsevier Ltd. All rights reserved.