765 resultados para Plane strain compression
Resumo:
Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.
Resumo:
This paper presents a large amplitude vibration analysis of pre-stressed functionally graded material (FGM) laminated plates that are composed of a shear deformable functionally graded layer and two surface-mounted piezoelectric actuator layers. Nonlinear governing equations of motion are derived within the context of Reddy's higher-order shear deformation plate theory to account for transverse shear strain and rotary inertia. Due to the bending and stretching coupling effect, a nonlinear static problem is solved first to determine the initial stress state and pre-vibration deformations of the plate that is subjected to uniform temperature change, in-plane forces and applied actuator voltage. By adding an incremental dynamic state to the pre-vibration state, the differential equations that govern the nonlinear vibration behavior of pre-stressed FGM laminated plates are derived. A semi-analytical method that is based on one-dimensional differential quadrature and Galerkin technique is proposed to predict the large amplitude vibration behavior of the laminated rectangular plates with two opposite clamped edges. Linear vibration frequencies and nonlinear normalized frequencies are presented in both tabular and graphical forms, showing that the normalized frequency of the FGM laminated plate is very sensitive to vibration amplitude, out-of-plane boundary support, temperature change, in-plane compression and the side-to-thickness ratio. The CSCF and CFCF plates even change the inherent hard-spring characteristic to soft-spring behavior at large vibration amplitudes. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
In-plane deformation of foams was studied experimentally by subjecting bidisperse foams to cycles of traction and compression at a prescribed rate. Each foam contained bubbles of two sizes with given area ratio and one of three initial arrangements: sorted perpendicular to the axis of deformation (iso-strain), sorted parallel to the axis of deformation (iso-stress), or randomly mixed. Image analysis was used to measure the characteristics of the foams, including the number of edges separating small from large bubbles N-sl, the perimeter (surface energy), the distribution of the number of sides of the bubbles, and the topological disorder mu(2)(N). Foams that were initially mixed were found to remain mixed after the deformation. The response of sorted foams, however, depended on the initial geometry, including the area fraction of small bubbles and the total number of bubbles. For a given experiment we found that (i) the perimeter of a sorted foam varied little; (ii) each foam tended towards a mixed state, measured through the saturation of N-sl; and (iii) the topological disorder mu(2)(N) increased up to an "equilibrium" value. The results of different experiments showed that (i) the change in disorder, Delta mu(2)(N), decreased with the area fraction of small bubbles under iso-strain, but was independent of it under iso-stress; and (ii) Delta mu(2)(N) increased with Delta N-sl under iso-strain, but was again independent of it under iso-stress. We offer explanations for these effects in terms of elementary topological processes induced by the deformations that occur at the bubble scale.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular.
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.
Resumo:
The structure, magnetic response, and dielectric response of the grown epitaxial thin films of the orthorhombic phase of YMnO3 oxide on Nb:SrTiO3 (001) substrates have been measured. We have found that a substrate-induced strain produces an in-plane compression of the YMnO3 unit cell. The magnetization versus temperature curves display a significant zero-field cooling (ZFC)-field cooling hysteresis below the Nel temperature (TN 45 K). The dielectric constant increases gradually (up to 26%) below the TN and mimics the ZFC magnetization curve. We argue that these effects could be a manifestation of magnetoelectric coupling in YMnO3 thin films and that the magnetic structure of YMnO3 can be controlled by substrate selection and/or growth conditions.
Resumo:
Some of the Iowa Department of Transportation (Iowa DOT) continuous, steel, welded plate girder bridges have developed web cracking in the negative moment regions at the diaphragm connection plates. The cracks are due to out-of-plane bending of the web near the top flange of the girder. The out-of-plane bending occurs in the "web-gap", which is the portion of the girder web between (1) the top of the fillet welds attaching the diaphragm connection plate to the web and (2) the fillet welds attaching the flange to the web. A literature search indicated that four retrofit techniques have been suggested by other researchers to prevent or control this type of cracking. To eliminate the problem in new bridges, AASHTO specifications require a positive attachment between the connection plate and the top (tension) flange. Applying this requirement to existing bridges is expensive and difficult. The Iowa DOT has relied primarily on the hole-drilling technique to prevent crack extension once cracking has occurred; however, the literature indicates that hole-drilling alone may not be entirely effective in preventing crack extension. The objective of this research was to investigate experimentally a method proposed by the Iowa DOT to prevent cracking at the diaphragm/plate girder connection in steel bridges with X-type or K-type diaphragms. The method consists of loosening the bolts at some connections between the diaphragm diagonals and the connection plates. The investigation included selecting and testing five bridges: three with X-type diaphragms and two with K-type diaphragms. During 1996 and 1997, these bridges were instrumented using strain gages and displacement transducers to obtain the response at various locations before and after implementing the method. Bridges were subjected to loaded test trucks traveling in different lanes with speeds varying from crawl speed to 65 mph (104 km/h) to determine the effectiveness of the proposed method. The results of the study show that the effect of out-of-plane loading was confined to widths of approximately 4 in. (100 mm) on either side of the connection plates. Further, they demonstrate that the stresses in gaps with drilled holes were higher than those in gaps without cracks, implying that the drilling hole technique is not sufficient to prevent crack extension. The behavior of the web gaps in X-type diaphragm bridges was greatly enhanced by the proposed method as the stress range and out-of-plane distortion were reduced by at least 42% at the exterior girders. For bridges with K-type diaphragms, a similar trend was obtained. However, the stress range increased in one of the web gaps after implementing the proposed method. Other design aspects (wind, stability of compression flange, and lateral distribution of loads) must be considered when deciding whether to adopt the proposed method. Considering the results of this investigation, the proposed method can be implemented for X-type diaphragm bridges. Further research is recommended for K-type diaphragm bridges.
Resumo:
Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.
Resumo:
Résumé de la thèseLa fracturation des roches au cours de phases compressives ou extensives est un souvent évoquée pour expliquer la circulation de fluide au sein des roches cristallines. Dans le cadre de cette thèse, la circulation des fluides lors de l'exhumation tardive des Alpes a été étudiée en utilisant deux approches différentes: analyses structurales de la déformation fragile d'une part et analyses géochimiques des roches et des minéraux (isotopes stables, datations U/Pb, thermochronologie (U-Th)/He) d'autre part. Cette approche combinée a permis de mieux comprendre l'interaction existante entre les fluides métamorphiques et les fluides météoriques, ainsi que leur interaction avec les roches encaissantes. Le travail a été effectué dans la zone Pennique du Valais suisse.La première partie était focalisée sur la déformation fragile, le but étant de définir les différents types de déformations existantes et de déterminer l'âge relatif des différentes familles de failles. Dans la région d'étude, quatre domaines ont été distingués. Chacun d'eux comportent deux types de structures fragiles, certaines sont minéralisées alors que d'autre non. Au sein de chaque domaine, la direction principale des structures minéralisées correspond à l'orientation des accidents tectoniques majeurs de la région (Aosta- Ranzola Line au Sud, Rhône Line au Nord et Simplon Fault Zone à l'Est), alors que les structures non- minéralisées montrent des orientations plus variables. Ainsi, le premier type de structure est interprété comme résultant d'une dislocation tectonique alors que le deuxième type de structure résulterait d'une dislocation gravitaire locale. Il n'est néanmoins pas possible de classer chronologiquement la formation de ces deux types de structure ni d'attribuer un âge relatif aux changements d'orientation des contraintes majeures.La deuxième étude a été effectuée dans la région de la zone de faille du Simplon. Dans cette zone, la composition isotopique des minéraux ayant cristallisé à l'intérieur des fractures tardives permet de distinguer différents types de circulation de fluide. Les valeurs δ180 du quartz de la roche encaissante ainsi que ceux des veines tardives du bloque inférieur de la faille sont comparables. Ces valeurs indiquent un rééquilibrage et un tamponnage isotopique des fluides tardifs au contact de la roche encaissante lors de la fracturation de cette dernière et de la cristallisation des veines tardives. La même situation est observée dans la partie nord du bloque supérieur ainsi que dans sa partie sud. Ceci n'est néanmoins pas le cas pour la partie centrale du bloque supérieur où les valeurs isotopiques des minéraux dans les veines tardives sont approximativement 3 %o plus basses (avec des valeurs extrêmes négatifs), indiquant une contribution d'eau météorique aux fluides circulant dans les veines. Ces données suggèrent qu'une infiltration d'eau météorique a pu avoir lieu dans le bloque supérieur, où la fracturation des roches est plus intensive car le déplacement relatif le long de la faille y fut plus important, et la température maximale du métamorphisme plus basse. La troisième contribution traite de la géo-thermochronologie de la zone de contact entre la klippe de la Dent Blanche et la nappe de Tsaté. De petits zircons euhédraux ont été trouvés dans un plan de faille minéralisé (parallèle à la Faille du Rhône, voir première partie de l'étude), riche en hématite et quartz, de la zone d'étude. Les analyses U/Pb donnent des âges radiométriques autour de 270 - 280 Ma aux zircons extraits de la minéralisation ainsi que ceux extraits de la roche encaissante, ce qui correspond à l'âge de la nappe de la Dent Blanche et non celui de la nappe du Tsaté qui est elle-même classiquement interprétée comme une ophiolite Jurassique de l'Océan Liguro-Piémontais. Ces données suggèrent que les zircons contenus dans la veine ont été hérités de la roche encaissante. Les résultats (U-Th)/He indiquent un âge de refroidissement différent pour la roche encaissante (25.5 ± 2.0 Ma) que celui de la minéralisation (17.7 ±1.4 Ma). Le thermomètre isotopique quartz-hématite indique une température d'équilibre, et donc de mise en place de la minéralisation, d'environ 170 °C, température très proche de la température de -180 °C de fermeture du zircon pour le système (U-Th)/He. Ceci suggère que l'âge de refroidissement des zircons de la minéralisation correspond aussi à l'âge de formation de la faille.Thesis abstractFluid circulation in fractured rocks is a common process in geology, and it is generally the consequence of faulting and fracturing during both tectonic compression and extension. This thesis is focused on fluid circulation during late stages of the Alpine exhumation. After a structural analysis of the late brittle deformation of the studied samples, several analytical methods (stable isotope investigations, U/Pb radiometric dating, (U-Th)/He thermochronology) have been applied to understand the interaction of metamorphic and meteoric fluids with one another as well as with the host rock. This thesis is articulated around three study directions. All studies were conducted in the Penninic Zone of the Valais, Switzerland. The first study deals with late, brittle deformation and focuses on the different deformation styles and on the relative age of the different families of fractures. In order to do this, late brittle structures observed in four different domains have been subdivided as a function of the existence (or not) and type of mineralization. Comparisons between mineralized and non-mineralized strike directions for all four domains show that mineralized structures follow the strike orientation of major tectonic movements indicated in the Penninic Zone of the Valais (Aosta-Ranzola Line to the S, Rhône Line to the Ν and Simplon Fault Zone to the E), whereas non-mineralized fractures have a more variable strike orientation. This difference could be interpreted as indicative of tectonic-related faulting (mineralized structures) vs. local, collapse-related faulting (non-mineralized fractures), but it is not strong enough to indicate a relative age of the late brittle structures, and/or a change in the orientation of the strain field in post-Miocene times. The second studied area is focused on the Simplon Fault Zone (SFZ). Stable isotope analyses of minerals filling these late fractures indicate that there are two different fluid circulation systems in the footwall and hanging wall of the SFZ. In the footwall, δ180 values of quartz from both the host rock and the late veins range from +10 %o to +12 %o. This is consistent with buffering of circulating fluids by the host rock during fracturing and vein precipitation. In the hanging wall, δΙ80 values for quartz crystals from the host rock and the late veins are similar in both the northern and southern parts of the detachment that are both affected by the same degree of metamorphism (greenschist to the Ν and amphibolite to the S). This is not the case in the central part of the SFZ, where there is a jump from amphibolite facies in the footwall to greenschist facies in the hanging wall. δ,80 values for quartz from the hanging wall late veins are approximately 3.0 %o lower (down to negative values in some cases) than the values observed in the footwall These data suggest that infiltration of meteoric water may have occurred in the most fractured parts of the hanging wall, where relative displacement on the SFZ was the greatest and the peak temperature lower. In the less fractured footwall the δ180 values reflect a host rock-buffered system.The third study is focused on geo-thermochronology at the contact between the Dent Blanche nappe and the Tsaté nappe where small, euhedral zircons were found in a hematite- and quartz-rich mineralization on a late normal fault plane parallel to the Rhône Line (see first part of the study). U/Pb analysis indicates that the zircons - both in the late mineralization and in the host rock - have absolute radiometric ages clustering around 270 - 280 Ma, which is the accepted age for intrusive rocks from the Austroalpine Dent Blanche units but not for the Tsaté nappe. The latter is classically interpreted as an ophiolitic remnant of the Jurassic Liguro-Piemontais Ocean. U/Pb analyses suggest that zircons in late mineralization are all inherited from the host rock; however, results of (U-Th)/He analyses indicate that cooling ages for the host rocks are different to the cooling ages for the zircons in late mineralization. Indeed, the calculated cooling age for the Arolla gneiss is 25.5 ± 2.0 Ma, whilst the cooling age for the associated mineralized fault plane is 17.7 ±1.4 Ma. Oxygen stable isotope fractionation between quartz and hematite in the same late mineralization corresponds to temperatures of about 170 °C. The proximity of the calculated emplacement temperature for the mineralization and the lower accepted closure temperature for zircon in the (U-Th)/He system (-180 °C) imply that the age of 17.7 ± 1.4 Ma can also be interpreted as the formation age of this late brittle fault.Résumé grand publicLa circulation des fluides dans les roches fracturées est typique de nombreux processus géologiques, et très souvent est la conséquence de la fracturation des roches. Cette thèse aborde la question de la circulation des fluides pendant les dernières phases du soulèvement des Alpes. Après une analyse structurale de la fracturation directement sur le terrain, plusieurs méthodes géochimiques ont été appliquées pour comprendre l'interaction entre les différents fluides circulants, et avec leur propre roche mère. L'étude, concentrée sur trois directions principales, a été conduite dans la zone Pennique du Valais suisse. La première partie traite de la déformation cassante dans le secteur cité. L'analyse détaillée des fractures a permis de les subdiviser en structures minéralisées et non-minéralisées, sur quatre domaines différents. La comparaison entre les directions des structures minéralisées et non-minéralisées a permis de montrer que les premières suivent l'orientation des accidents tectoniques majeurs de la région, alors que les structures non- minéralisées ont une orientation plus variable. Cette différence pourrait être interprétée comme indication d'une dislocation tectonique (structures minéralisées) contre une dislocation gravitaire locale (structures non-minéralisées), mais elle n'est pas assez forte pour indiquer un âge relatif des structures tardives et/ou un changement de l'orientation des contraintes après -20 Ma vers le présent.A partir de ces observations, la deuxième étude est concentrée dans la région de la faille du Simplon. Les analyses géochimiques sur les minéraux remplissant les structures tardives indiquent qu'il y a deux différents systèmes de circulation des fluides dans les deux parties (toit et mur) de la faille. Dans le mur, les valeurs isotopiques des minéraux cristallisés à partir d'un fluide tardif sont les mêmes de ceux de la roche mère, donc il y a eu rééquilibration chimique entre fluide et roche pendant la fracturation de cette dernière et la précipitation des minéraux. Dans le toit, les valeurs isotopiques dans la roche mère et dans les minéraux des veines tardives sont comparables dans les parties Ν et S de la faille, où les roches du toit et du mur ont atteint une température maximale - pendant phase prograde de la formation des Alpes - comparable. Au contraire, dans la partie centrale, où le mur a atteint des températures maximales plus élevées par rapport au toit, les valeurs géochimiques des minéralisations tardives du toit sont parfois plus basses que les valeurs observées dans le mur. Ces données suggèrent que l'infiltration de l'eau de surface aurait pu se produire dans la partie plus fracturée du toit, où le déplacement relatif le long de la faille était majeur et les températures maximales mineures. Au contraire, les données géochimiques du mur de la partie centrale indiquent un système isotopique équilibré par la roche mère.La troisième partie de ce travail se base sur l'étude géochimique intégrée des isotopes stables d'Oxygène et radioactifs du Plomb, Uranium, Thorium et Hélium, auprès d'une faille normale minéralisée et des roches de la région à cheval entre deux nappes, la nappe de la Dent Blanche et la nappe de Tsaté. Ici, des petits zircons ont été trouvés dans la minéralisation citée, riche en hématite et quartz. L'analyse radiométrique Uranium/Plomb a montré que les zircons dans la minéralisation et dans les roches autour ont des âges comparables (autour 280 Ma). Cela signifie que les zircons dans la minéralisation tardive ont été hérités de la roche mère pendant la fracturation et la circulation des fluides tardives. De l'autre coté, les résultats des analyses Uranium-Thorium/Hélium indiquent que les âges de refroidissement pour les roches mères sont différents comparés aux âges de refroidissement pour les zircons dans la minéralisation tardive: ces derniers sont plus jeunes d'environ 8 Ma (autour 25 Ma et autour 17 Ma respectivement). Les analyses des isotopes de l'oxygène sur quartz et hématite dans la même minéralisation donnent une température de mise en place de cette dernière d'environ 170° C. La température de fermeture du système chimique des zircons dans le système (Uranium-Thorium)/Hélium est d'environ 180 °C: la proximité de ces deux températures implique que l'âge de refroidissement de la minéralisation tardive peut également être interprété comme âge de formation de la faille.
Resumo:
The strength properties of paper coating layer are very important in converting and printing operations. Too great or low strength of the coating can affect several problems in printing. One of the problems caused by the strength of coating is the cracking at the fold. After printing the paper is folded to final form and the pages are stapled together. In folding the paper coating can crack causing aesthetic damage over printed image or in the worst case the centre sheet can fall off in stapling. When folding the paper other side undergoes tensile stresses and the other side compressive stresses. If the difference between these stresses is too high, the coating can crack on the folding. To better predict and prevent cracking at the fold it is good to know the strength properties of coating layer. It has measured earlier the tensile strength of coating layer but not the compressive strength. In this study it was tried to find some way to measure the compressive strength of the coating layer and investigate how different coatings behave in compression. It was used the short span crush test, which is used to measure the in-plane compressive strength of paperboards, to measure the compressive strength of the coating layer. In this method the free span of the specimen is very small which prevent buckling. It was measured the compressive strength of free coating films as well as coated paper. It was also measured the tensile strength and the Bendtsen air permeance of the coating film. The results showed that the shape of pigment has a great effect to the strength of coating. Platy pigment gave much better strength than round or needle-like pigment. On the other hand calcined kaolin, which is also platy but the particles are aggregated, decreased the strength substantially. The difference in the strength can be explained with packing of the particles which is affecting to the porosity and thus to the strength. The platy kaolin packs up much better than others and creates less porous structure. The results also showed that the binder properties have a great effect to the compressive strength of coating layer. The amount of latex and the glass transition temperature, Tg, affect to the strength. As the amount of latex is increasing, the strength of coating is increasing also. Larger amount of latex is binding the pigment particles better together and decreasing the porosity. Compressive strength was increasing when the Tg was increasing because the hard latex gives a stiffer and less elastic film than soft latex.
Resumo:
Spinal cord injury is an extremely severe condition with no available effective therapies. We examined the effect of melatonin on traumatic compression of the spinal cord. Sixty male adult Wistar rats were divided into three groups: sham-operated animals and animals with 35 and 50% spinal cord compression with a polycarbonate rod spacer. Each group was divided into two subgroups, each receiving an injection of vehicle or melatonin (2.5 mg/kg, intraperitoneal) 5 min prior to and 1, 2, 3, and 4 h after injury. Functional recovery was monitored weekly by the open-field test, the Basso, Beattie and Bresnahan locomotor scale and the inclined plane test. Histological changes of the spinal cord were examined 35 days after injury. Motor scores were progressively lower as spacer size increased according to the motor scale and inclined plane test evaluation at all times of assessment. The results of the two tests were correlated. The open-field test presented similar results with a less pronounced difference between the 35 and 50% compression groups. The injured groups presented functional recovery that was more evident in the first and second weeks. Animals receiving melatonin treatment presented more pronounced functional recovery than vehicle-treated animals as measured by the motor scale or inclined plane. NADPH-d histochemistry revealed integrity of the spinal cord thoracic segment in sham-operated animals and confirmed the severity of the lesion after spinal cord narrowing. The results obtained after experimental compression of the spinal cord support the hypothesis that melatonin may be considered for use in clinical practice because of its protective effect on the secondary wave of neuronal death following the primary wave after spinal cord injury.
Resumo:
Supramolecular polyurethanes (SPUs) possess thermoresponsive and thermoreversible properties, and those characteristics are highly desirable in both bulk commodity and value-added applications such as adhesives, shape-memory materials, healable coatings and lightweight, impact-resistant structures (e.g. protection for mobile electronics). A better understanding of the mechanical properties, especially the rate and temperature sensitivity, of these materials are required to assess their suitability for different applications. In this paper, a newly developed SPU with tuneable thermal properties was studied, and the response of this SPU to compressive loading over strain rates from 10−3 to 104 s−1 was presented. Furthermore, the effect of temperature on the mechanical response was also demonstrated. The sample was tested using an Instron mechanical testing machine for quasi-static loading, a home-made hydraulic system for moderate rates and a traditional split Hopkinson pressure bars (SHPBs) for high strain rates. Results showed that the compression stress-strain behaviour was affected significantly by the thermoresponsive nature of SPU, but that, as expected for polymeric materials, the general trends of the temperature and the rate dependence mirror each other. However, this behaviour is more complicated than observed for many other polymeric materials, as a result of the richer range of transitions that influence the behaviour over the range of temperatures and strain rates tested.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
When a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n = 5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.