919 resultados para Pet Kinetics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium carbonitride-based cermets are important materials for contemporary cutting tools. Ceramic powders of Ti(CN), TaC, WC were mixed, compacted and heat-treated at high temperatures to form (Ti, W, Ta)(C, N) solid solution, which was then ball-milled to fine powders before being mixed with metallic binder and compacted. Liquid-phase sintering of the samples was carried out in a nitrogen atmosphere at different sintering temperatures and holding times. The microhardness and porosity of the sintered cermets were studied. It is demonstrated that the microhardness increases with sintering temperature, but at the same time, the porosity level also goes up with temperature and time. At the beginning of sintering (zero holding time), the majority of the pores are small (0.1 similar to 1 mu m); during sintering, the larger ports grow at the expense of smaller pores and the resulting pores are all concentrated in the 10 similar to 100 mu m range. The number of larger pores increases with temperature and prolonged holding time, which results in deteriorated properties. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Absorption kinetics of solutes given with the subcutaneous administration of fluids is ill-defined. The gamma emitter, technitium pertechnetate, enabled estimates of absorption rate to be estimated independently using two approaches. In the first approach, the counts remaining at the site were estimated by imaging above the subcutaneous administration site, whereas in the second approach, the plasma technetium concentration-time profiles were monitored up to 8 hr after technetium administration. Boluses of technetium pertechnetate were given both intravenously and subcutaneously on separate occasions with a multiple dosing regimen using three doses on each occasion. The disposition of technetium after iv administration was best described by biexponential kinetics with a V-ss of 0.30 +/- 0.11 L/kg and a clearance of 30.0 +/- 13.1 ml/min. The subcutaneous absorption kinetics was best described as a single exponential process with a half-life of 18.16 +/- 3.97 min by image analysis and a half-life of 11.58 +/- 2.48 min using plasma technetium time data. The bioavailability of technetium by the subcutaneous route was estimated to be 0.96 +/- 0.12. The absorption half-life showed no consistent change with the duration of the subcutaneous infusion. The amount remaining at the absorption site with time was similar when analyzed using image analysis, and plasma concentrations assuming multiexponential disposition kinetics and a first-order absorption process. Profiles of fraction remaining at the absorption sire generated by deconvolution analysis, image analysis, and assumption of a constant first-order absorption process were similar. Slowing of absorption from the subcutaneous administration site is apparent after the last bolus dose in three of the subjects and can De associated with the stopping of the infusion. In a fourth subject, the retention of technetium at the subcutaneous site is more consistent with accumulation of technetium near the absorption site as a result of systemic recirculation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether gestational immunization of HIV-infected mothers with the 23-valent pneumococcal polysaccharide vaccine (PPV) confers maternal and infant early life, passive protection is not known. We evaluated safety, immunogenicity and placental transfer of antibodies in 44 HIV-infected women. Pneumococcal IgG antibodies against serotypes 1, 3, 5, 613, 9V, and 14 were measured in mothers (pre-vaccination and at delivery), and infants (at birth, 1, 2, 3, and 6 months). PPV was safe and immunogenic in mothers. Newborns received 46-72% of maternal antibody titers. Overall, infants had antibody levels lower than protective by 2 months of age. Alternative pneumococcal vaccination of HIV-infected pregnant women should be explored with the aim of prolonging passive protection in their infants. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to assess the prognostic value of (18)F-FDG PET after 2 cycles of chemotherapy using doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) in Hodgkin lymphoma (HL) patients overall and in subgroups of patients with early and advanced stages and with low and high risks according to the International Prognostic Score (IPS). Methods: One hundred fifteen patients with newly diagnosed HL were prospectively included in the study. All underwent standard ABVD therapy followed by consolidation radiotherapy in cases of bulky disease. After 2 cycles of ABVD, the patients were evaluated with PET (PET2). Prognostic analysis compared the 3-y event-free survival (EFS) rate to the PET2 results, clinical data, and IPS. Results: Of the 104 evaluated patients, 93 achieved complete remission after first-line therapy. During a median follow-up of 36 mo, relapse or disease progression was seen in 22 patients. Treatment failure was seen in 16 of the 30 PET2-positive patients and in only 6 of the 74 PET2-negative patients. PET2 was the only significant prognostic factor. The 3-y EFS was 53.4% for PET2-positive patients and 90.5% for PET2-negative ones (P < 0.001). When patients were categorized according to low or high IPS risk and according to early or advanced stage of disease, PET2 was also significantly associated with treatment outcome. Conclusion: PET2 is an accurate and independent predictor of EFS in HL. A negative interim (18)F-FDG PET result is highly predictive of treatment success in overall HL patients, as well as in subgroups with early or advanced-stage disease and with low or high IPS risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Two hundred ten patients with newly diagnosed Hodgkin`s lymphoma (HL) were consecutively enrolled in this prospective trial to evaluate the cost-effectiveness of fluorine-18 ((18)F)-fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) scan in initial staging of patients with HL. Methods: All 210 patients were staged with conventional clinical staging (CCS) methods, including computed tomography (CT), bone marrow biopsy (BMB), and laboratory tests. Patients were also submitted to metabolic staging (MS) with whole-body FDG-PET scan before the beginning of treatment. A standard of reference for staging was determined with all staging procedures, histologic examination, and follow-up examinations. The accuracy of the CCS was compared with the MS. Local unit costs of procedures and tests were evaluated. Incremental cost-effectiveness ratio (ICER) was calculated for both strategies. Results: In the 210 patients with HL, the sensitivity for initial staging of FDG-PET was higher than that of CT and BMB in initial staging (97.9% vs. 87.3%; P < .001 and 94.2% vs. 71.4%, P < 0.003, respectively). The incorporation of FDG-PET in the staging procedure upstaged disease in 50 (24%) patients and downstaged disease in 17 (8%) patients. Changes in treatment would be seen in 32 (15%) patients. Cumulative cost for staging procedures was $3751/patient for CCS compared to $5081 for CCS + PET and $4588 for PET/CT. The ICER of PET/CT strategy was $16,215 per patient with modified treatment. PET/CT costs at the beginning and end of treatment would increase total costs of HL staging and first-line treatment by only 2%. Conclusion: FDG-PET is more accurate than CT and BMB in HL staging. Given observed probabilities, FDG-PET is highly cost-effective in the public health care program in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ten male Holstein calves (74.3 +/- 3.2 kg LW) were used for a trial with trickle infection with Cooperia punctata to evaluate phosphorus (P) kinetics. Five calves were inoculated with 10,000 L(3) stage larvae per week during 35 days, while the other group of five calves was kept as a control. On the 29th day each calf was intravenously injected with 29.6 MBq of a (32)p solution. Blood samples were taken at 24 h periods for 7 days, after which all calves were slaughtered and worms burdens. Faeces, urine and tissue samples were taken for analysis using isotopic dilution and modeling techniques. The number of eggs per gram of faeces (EPG)was 1920 +/- 168 on 28th day and the total number of worms burdens was 11,131 +/- 1500. Infected calves showed lower feed intake and live weight gain, as well as lower P intake, absorption and retention than control calves. The P flows between body compartments were lower for blood to gastrointestinal tract (TGI), TGI to blood, blood to soft tissues, bone balance and soft tissue balance in infected calves when compared to the control. The trickle infection of C punctata affected P metabolism due to the decrease in P retained and live weight due to fall in feed intake. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate growth and physiology are regulated by steroid hormones and modulated by multiple endocrine factors We investigated the action of insulin on the tissue organization and kinetics of epithelial cells in the rat ventral prostate (VP) in response to castration up to 120 hours after surgery by using an acute protocol of alloxan induced diabetes Diabetes caused a reduction in volume density (Vv(o)/) and volume of the epithelium The effects of castration on the epithelium were accelerated in the diabetic animals as determined by changes in V(o)/, and volume The smooth muscle cells became atrophic and apparently relaxed in response to castration in contrast to the spinous aspect observed in nondiabetic castrated rats Counting of apoptotic nuclei in the epithelium showed the classical apoptosis peak at 72 hours in nondiabetic rats and an advance of the apoptosis peak to 48 hours after castration in diabetic rats Insulin restored the time of the peak to 72 hours These results were confirmed after immunostaining for cleaved caspase 3 and suggest a survival and antiapoptotic effect on VP epithelial cells in both the presence and absence of androgen stimulation This idea is supported by the observation that insulin also reduced the overall rate of apoptosis at all experimental points analyzed before and after castration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the influence of rate of polymerization, degree of conversion and volumetric shrinkage on stress development by varying the amount of photoinitiators in a model composite. Methods: Volumetric shrinkage (with a mercury dilatometer), degree of conversion, maximum rate of reaction (RP(max)) (with differential scanning calorimetry) and polymerization stress (with a controlled compliance device) were evaluated. Bis-GMA/TEGDMA (equal mass ratios) were mixed with a tertiary amine (EDMAB) and camphorqpinone, respectively, in three concentrations (wt%): high= 0.8/1.6; intermediate= 0.4/0.8 and low= 0.2/0.4. 80 wt% filler was added. Composites were photoactivated (400 mW/cm(2) x 40 seconds; radiant exposure=16J/cm(2)). A fourth experimental group was included in which the low concentration formulation was exposed for 80 seconds (32 J/cm(2)). Results: For the same radiant exposure, conversion, RP(max) and stress increased with photoinitiator concentration (P< 0.001). When the low concentration group exposed to 32 J/cm(2) was compared with the high and intermediate groups (exposed to 16 J/cm(2)), RPmax Still increased with the photoinitiator concentration between all levels (P< 0.001) but conversion and stress did not vary (P> 0.05). Shrinkage did not vary regardless of the photoinitiator concentration or radiant exposure. For the photoinitiator concentrations used in this study. Polymerization stress was influenced by conversion but not by rate of reaction. (Am J Dent 2009;22:206-210).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the kinetics of fluoride in plasma, femur surface and the whole femur of rats, after chronic exposure to different water fluoride levels was interrupted. Four groups of Wistar rats received drinking water containing 0, 5, 15 or 50 mu g F/ml for 60 days (n = 50/group). The animals were euthanized immediately after exposure to fluoride or after 7, 30, 90 or 180 days (n = 10/subgroup). Plasma and femurs were collected. Fluoride on the femur surface, whole femur and plasma was analyzed with an electrode. Data were analyzed using ANOVA and Tukey`s test (p < 0.05). The increase in plasma fluoride levels was significant only for the 50 mu g F/ml group at 0 and 7 days. Regarding bone surface and whole bone, for most groups, significant increases in fluoride concentrations were observed with the increase in water fluoride concentrations at each time of euthanasia. For fluoride doses up to 15 mu g F/ml, femur surface fluoride levels were reestablished 180 days after the exposure was discontinued, which Was not valid for whole femur or for higher fluoride doses. We found a different kinetics of fluoride in plasma,femur surface and the whole femur of rats after chronic exposure to fluoride is interrupted. Copyright 2008 Prous Science, S.A.U. or its licensors. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diffusion model for percutaneous absorption is developed for the specific case of delivery to the skin being limited by the application of a finite amount of solute. Two cases are considered; in the first, there is an application of a finite donor (vehicle) volume, and in the second, there are solvent-deposited solids and a thin vehicle with a high partition coefficient. In both cases, the potential effect of an interfacial resistance at the stratum corneum surface is also considered. As in the previous paper, which was concerned with the application of a constant donor concentration, clearance limitations due to the viable eqidermis, the in vitro sampling rate, or perfusion rate in vivo are included. Numerical inversion of the Laplace domain solutions was used for simulations of solute flux and cumulative amount absorbed and to model specific examples of percutaneous absorption of solvent-deposited solids. It was concluded that numerical inversions of the Laplace domain solutions for a diffusion model of the percutaneous absorption, using standard scientific software (such as SCIENTIST, MicroMath Scientific software) on modern personal computers, is a practical alternative to computation of infinite series solutions. Limits of the Laplace domain solutions were used to define the moments of the flux-time profiles for finite donor volumes and the slope of the terminal log flux-time profile. The mean transit time could be related to the diffusion time through stratum corneum, viable epidermal, and donor diffusion layer resistances and clearance from the receptor phase. Approximate expressions for the time to reach maximum flux (peak time) and maximum flux were also derived. The model was then validated using reported amount-time and flux-time profiles for finite doses applied to the skin. It was concluded that for very small donor phase volume or for very large stratum corneum-vehicle partitioning coefficients (e.g., for solvent deposited solids), the flux and amount of solute absorbed are affected by receptor conditions to a lesser extent than is obvious for a constant donor constant donor concentrations. (C) 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90:504-520, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microwave and thermal cure processes for the epoxy-amine systems N,N,N',N'-tetraglycidyl-4,4'-diaminodiphenyl methane (TGDDM) with diaminodiphenyl sulfone (DDS) and diaminodiphenyl methane (DDM) have been investigated. The DDS system was studied at a single cure temperature of 433 K and a single stoichiometry of 27 wt% and the DDM system was studied at two stoichiometries, 19 and 32 wt%, and a range temperatures between 373 and 413 K. The best values the kinetic rate parameters for the consumption of amines have been determined by a least squares curve Ft to a model for epoxy-amine cure. The activation energies for the rate parameters for the MY721/DDM system were determined as was the overall activation energy for the cure reaction which was found to be 62 kJ mol(-1). No evidence was found for any specific effect of the microwave radiation on the rate parameters, and the systems were both found to be characterized by a negative substitution effect. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The batch removal of hexavalent chromium (Cr(Vl)) from wastewater under different experimental conditions using economic adsorbents was investigated in this study. These adsorbents were produced from the pyrolysis and activation of the waste tyres (TAC) and from the pyrolysis of sawdust (SPC). The performance of these adsorbents against commercial activated carbon F400 (CAC) has also been carried out. The removal was favoured at low pH, with maximum removal at pH = 2 for all types of carbon. The effects of concentration, temperature and particle size have been reported. All sorbents were found to efficiently remove Cr(VI) from solution. The batch sorption kinetics have been tested for a first-order reversible reaction, a first-order and second-order reaction. The rate constants of adsorption for all these kinetic models have been calculated. The applicability of the Langmuir isotherm for the present system has been tested at different temperatures. The thermodynamic parameters (AGO, K,) obtained indicate the endothermic nature of Cr(Vl) adsorption on TAC, SPC and CAC. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a model for permeation in oxide coated gas barrier films. The model accounts for diffusion through the amorphous oxide lattice, nano-defects within the lattice, and macro-defects. The presence of nano-defects indicate the oxide layer is more similar to a nano-porous solid (such as zeolite) than silica glass with respect to permeation properties. This explains why the permeability of oxide coated polymers is much greater, and the activation energy of permeation much lower, than values expected for polymers coated with glass. We have used the model to interpret permeability and activation energies measured for the inert gases (He, Ne and Ar) in evaporated SiOx films of varying thickness (13-70 nm) coated on a polymer substrate. Atomic force and scanning electron microscopy were used to study the structure of the oxide layer. Although no defects could be detected by microscopy, the permeation data indicate that macro-defects (>1 nm), nano-defects (0.3-0.4 nm) and the lattice interstices (<0.3 nm) all contribute to the total permeation. (C) 2002 Elsevier Science B.V. All rights reserved.