991 resultados para PORCINE MODEL


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Mortality of patients with acute liver failure (ALF) is still unacceptably high. Available liver support systems are still of limited success at improving survival. A new type of albumin dialysis, the Hepa Wash® system, was newly introduced. We evaluated the new liver support system as well as the Molecular Adsorbent Recycling System (MARS) in an ischemic porcine model of ALF. METHODS In the first study animals were randomly allocated to control (n=5) and Hepa Wash (n=6) groups. In a further pilot study, two animals were treated with the MARS-system. All animals received the same medical and surgical procedures. An intraparenchymal intracranial pressure was inserted. Hemodynamic monitoring and goal-directed fluid therapy using the PiCCO system was done. Animals underwent functional end-to-side portacaval shunt and ligation of hepatic arteries. Treatment with albumin dialysis was started after fall of cerebral perfusion pressure to 45 mmHg and continued for 8 h. RESULTS All animals in the Hepa Wash group survived the 13-hour observation period, except for one that died after stopping treatment. Four of the control animals died within this period (p=0.03). Hepa Wash significantly reduced impairment of cerebral perfusion pressure (23±2 vs. 10±3 mmHg, p=0.006) and mean arterial pressure (37±1 vs. 24±2 mmHg, p=0.006) but had no effect on intracranial pressure (14±1 vs. 15±1 mmHg, p=0.72). Hepa Wash also enhanced cardiac index (4.94±0.32 vs. 3.36±0.25 l/min/m2, p=0.006) and renal function (urine production, 1850 ± 570 vs. 420 ± 180 ml, p=0.045) and eliminated water soluble (creatinine, 1.3±0.2 vs. 3.2±0.3 mg/dl, p=0.01; ammonia 562±124 vs. 1382±92 μg/dl, p=0.006) and protein-bound toxins (nitrate/nitrite 5.54±1.57 vs. 49.82±13.27 μmol/l, p=0.01). No adverse events that could be attributed to the Hepa Wash treatment were observed. CONCLUSIONS Hepa Wash was a safe procedure and improved multiorgan system failure in pigs with ALF. The survival benefit could be the result of ameliorating different organ functions in association with the detoxification capacity of water soluble and protein-bound toxins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Selective retina therapy (SRT) has shown great promise compared to conventional retinal laser photocoagulation as it avoids collateral damage and selectively targets the retinal pigment epithelium (RPE). Its use, however, is challenging in terms of therapy monitoring and dosage because an immediate tissue reaction is not biomicroscopically discernibel. To overcome these limitations, real-time optical coherence tomography (OCT) might be useful to monitor retinal tissue during laser application. We have thus evaluated a proprietary OCT system for its capability of mapping optical changes introduced by SRT in retinal tissue. Methods: Freshly enucleated porcine eyes, covered in DMEM upon collection were utilized and a total of 175 scans from ex-vivo porcine eyes were analyzed. The porcine eyes were used as an ex-vivo model and results compared to two time-resolved OCT scans, recorded from a patient undergoing SRT treatment (SRT Vario, Medical Laser Center Lübeck). In addition to OCT, fluorescin angiography and fundus photography were performed on the patient and OCT scans were subsequently investigated for optical tissue changes linked to laser application. Results: Biomicroscopically invisible SRT lesions were detectable in OCT by changes in the RPE / Bruch's complex both in vivo and the porcine ex-vivo model. Laser application produced clearly visible optical effects such as hyperreflectivity and tissue distortion in the treated retina. Tissue effects were even discernible in time-resolved OCT imaging when no hyper-reflectivity persisted after treatment. Data from ex-vivo porcine eyes showed similar to identical optical changes while effects visible in OCT appeared to correlate with applied pulse energy, leading to an additional reflective layer when lesions became visible in indirect ophthalmoscopy. Conclusions: Our results support the hypothesis that real-time high-resolution OCT may be a promising modality to obtain additional information about the extent of tissue damage caused by SRT treatment. Data shows that our exvivo porcine model adequately reproduces the effects occurring in-vivo, and thus can be used to further investigate this promising imaging technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Postmortem investigation is increasingly supported by Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). This led to the idea to implement a noninvasive or minimally invasive autopsy technique. Therefore, a minimally invasive angiography technique becomes necessary, in order to support the vascular cross section diagnostic. Preliminary experiments investigating different contrast agents for CT and MRI and their postmortem applicability have been performed using an ex-vivo porcine coronary model. MSCT and MRI angiography was performed in the porcine model. Three human corpses were investigated using minimally invasive MSCT angiography. Via the right femoral artery a plastic tube was advanced into the aortic arch. Using a flow adjustable pump the radiopaque contrast agent meglumine-ioxithalamate was injected. Subsequent MSCT scanning provided an excellent anatomic visualization of the human arterial system including intracranial and coronary arteries. Vascular pathologies such as calcification, stenosis and injury were detected. Limitations of the introduced approach are cases of major vessel injury and cases that show an advanced stage of decay.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

NO synthases are widely distributed in the lung and are extensively involved in the control of airway and vascular homeostasis. It is recognized, however, that the O2-rich environment of the lung may predispose NO toward toxicity. These Janus faces of NO are manifest in recent clinical trials with inhaled NO gas, which has shown therapeutic benefit in some patient populations but increased morbidity in others. In the airways and circulation of humans, most NO bioactivity is packaged in the form of S-nitrosothiols (SNOs), which are relatively resistant to toxic reactions with O2/O\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} \begin{equation*}{\mathrm{_{2}^{-}}}\end{equation*}\end{document}. This finding has led to the proposition that channeling of NO into SNOs may provide a natural defense against lung toxicity. The means to selectively manipulate the SNO pool, however, has not been previously possible. Here we report on a gas, O-nitrosoethanol (ENO), which does not react with O2 or release NO and which markedly increases the concentration of indigenous species of SNO within airway lining fluid. Inhalation of ENO provided immediate relief from hypoxic pulmonary vasoconstriction without affecting systemic hemodynamics. Further, in a porcine model of lung injury, there was no rebound in cardiopulmonary hemodynamics or fall in oxygenation on stopping the drug (as seen with NO gas), and additionally ENO protected against a decline in cardiac output. Our data suggest that SNOs within the lung serve in matching ventilation to perfusion, and can be manipulated for therapeutic gain. Thus, ENO may be of particular benefit to patients with pulmonary hypertension, hypoxemia, and/or right heart failure, and may offer a new therapeutic approach in disorders such as asthma and cystic fibrosis, where the airways may be depleted of SNOs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of magnets for anchoring of instrumentation in minimally invasive surgery and endoscopy has become of increased interest in recent years. Permanent magnets have significant advantages over electromagnets for these applications; larger anchoring and retraction force for comparable size and volume without the need for any external power supply. However, permanent magnets represent a potential hazard in the operating field where inadvertent attraction to surgical instrumentation is often undesirable. The current work proposes an interesting hybrid approach which marries the high forces of permanent magnets with the control of electromagnetic technology including the ability to turn the magnet OFF when necessary. This is achieved through the use of an electropermanent magnet, which is designed for surgical retraction across the abdominal and gastric walls. Our electropermanent magnet, which is hand-held and does not require continuous power, is designed with a center lumen which may be used for trocar or needle insertion. The device in this application has been demonstrated successfully in the porcine model where coupling between an intraluminal ring magnet and our electropermanent magnet facilitated guided insertion of an 18 Fr Tuohy needle for guidewire placement. Subsequent investigations have demonstrated the ability to control the coupling distance of the system alleviating shortcomings with current methods of magnetic coupling due to variation in transabdominal wall thicknesses. With further refinement, the magnet may find application in the anchoring of endoscopic and surgical instrumentation for minimally invasive interventions in the gastrointestinal tract.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Apesar dos avanços na sua abordagem terapêutica, a hemorragia severa continua a ser a principal causa de morbilidade e mortalidade em animais vítimas de trauma ou sujeitos a intervenção cirúrgica. O aparecimento de lesões decorrentes, ou da morte consequente, deve-se ao deficit de volume de fluidos intravasculares e subsequente desenvolvimento do estado hipovolémico. Em termos fisiológicos, a consequência mais devastadora desta condição é a diminuição, absoluta ou relativa, da pré-carga cardíaca, resultando num baixo débito cardíaco, perfusão tecidular inadequada e diminuição do aporte de oxigénio aos tecidos, o qual compromete, inequivocamente, a função celular. O controlo da hipovolémia passa pela resolução da hemorragia e pela correção do deficit de volume intravascular causado e envolve, obrigatoriamente, o recurso à administração de fluidos intravenosos. A escolha do tipo de fluido mais adequado para a terapia intravenosa, em cada ocorrência, é uma tarefa que exige reflexão e ponderação. A seleção dos fluidos apropriados é da responsabilidade do médico veterinário, sendo, no entanto, fundamental que o enfermeiro veterinário detenha conhecimentos básicos sobre as diferenças entre os fluidos disponíveis para a fluidoterapia. O objetivo deste projeto é determinar qual o tipo de fluido mais adequado para ajudar a preservar a integridade e funcionalidade hepática, em situações de hipoperfusão, e assim ajudar a padronizar a sua escolha no momento da decisão pela fluidoterapia. Para atingir este objetivo recorreu-se ao modelo suíno, a fim de recrear a situação de hipoperfusão e posteriormente avaliar os efeitos de dois fluidos diferentes administrados na reposição volémica, o lactato de Ringer e hidroxietilamido 130/0,4. Os animais foram sujeitos a uma hemorragia controlada, após a qual foi reposta a volémia com os respetivos fluidos. Após esta reposição volémica os animais foram eutanaziados e foram obtidas amostras de vários órgãos, incluindo fígado, objeto do presente estudo, alvo de diversas técnicas histopatológicas, nomeadamente o estudo histopatológico de rotina, através de hematoxilina e eosina, e diversos métodos para deteção de eventos apoptóticos, incluindo citocromo c, TUNEL e M30.Após a avaliação exaustiva dos resultados obtidos através das técnicas realizadas, foi possível concluir que o lactato de Ringer confere uma maior proteção contra a lesão de reperfusão, quando comparado com o hidroxietilamido 130/0,4.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo: Determinar diferencias en las impedancias basales registradas durante los procedimientos de denervación renal por radiofrecuencia de los pacientes sometidos a este procedimiento en la Fundación Cardioinfantil de Bogotá durante los años 2012 a 2015. Materiales y métodos: Estudio observacional, analítico de corte retrospectivo, donde se analizaron todas las impedancias basales medidas durante los procedimientos de denervación renal, buscando diferencias significativas entre los segmentos de las arterias intervenidas, estratificados en proximal, medio distal y superior, lateral, inferior u ostial. Con seguimiento a los pacientes a tres, seis y doce meses en cuanto a presión arterial de consultorio. Resultados: Se evaluaron 150 puntos de denervación renal exitosos, correspondientes a 23 arterias renales de 11 procedimientos. La mediana de edad fue 56 años. Al realizar un modelo de regresión lineal no se encontró ninguna diferencia estadísticamente significativa entre las impedancias de ninguno de los segmentos de las arterias ni sitios anatómicos. Se documentó disminución de presión arterial sistólica a tres meses, seis meses y doce meses de 14 mmHg (RIQ 10-33mmHg), 21 mmHg (RIQ 12-42mmHg) y 19 mmHg (RIQ 11-42 mmHg) respectivamente

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We developed a reproducible model of deep dermal partial thickness burn injury in juvenile Large White pigs. The contact burn is created using water at 92 degrees C for 15s in a bottle with the bottom replaced with plastic wrap. The depth of injury was determined by a histopathologist who examined tissue sections 2 and 6 days after injury in a blinded manner. Upon creation, the circular wound area developed white eschar and a hyperaemic zone around the wound border. Animals were kept for 6 weeks or 99 days to examine the wound healing process. The wounds took between 3 and 5 weeks for complete re-epithelialisation. Most wounds developed contracted, purple, hypertrophic scars. On measurement, the thickness of the burned skin was approximately 1.8 times that of the control skin at week 6 and approximately 2.2 times thicker than control skin at 99 days after injury. We have developed various methods to assess healing wounds, including digital photographic analysis, depth of organising granulation tissue, immunohistochemistry, electron microscopy and tensiometry. Immunohistochemistry and electron microscopy showed that our porcine hypertrophic scar appears similar to human hypertrophic scarring. The development of this model allows us to test and compare different treatments on burn wounds.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We read with great interest the article entitled “Enhancing drugs absorption through third-degree burn wound eschar” by Manafi et al. [1]. The authors addressed the concern of poor penetration of topically applied anti-microbials through burn eschar and detailed the improvement of this penetration by penetration enhancers. Here, we would like to report the poor penetration of a topical agent into the viable deep dermal layer under burn eschar on a porcine burn model [2]. In burn treatment, a common practice is the topical application of either anti-microbial products or wound enhancing agents. While the activity of anti-microbial products is designed to fight against microbes on the wound surface but with the least toxicity to viable tissue, wound enhancing agents need to reach the viable tissue layer under the burn eschar. Many studies have reported the accelerated healing of superficial burn wounds and skin graft donor sites by the topical application of exogeneous growth factors [3]. It is well known that the efficacy of the penetration of a topical agent on intact skin mostly depends on the molecular size of the product [4] and [5]. While burn injury destroys this epidermal physiological barrier, the coagulated burn tissue layer on the burn wound surface makes it difficult for topical agents to reach viable tissue....

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In thermal deep-dermal burns, surgical debridement is normally used in conjunction with skin grafting or skin substitutes and debridement alone as a burn treatment is not usually practiced. The current study addresses whether or not debridement alone would enhance burn wound healing on small deep-dermal-partial thickness burns. This was a prospective and blinded experimental trial using a porcine deep-dermal-partial thickness burn model. Four burns, approximately 50 cm(2) in size, were created on each of eight pigs. Two burns from each pig were immediately surgically debrided and the other two were not debrided as the internal control. Hydrate gel together with paraffin gauze were used to cover the burns for four pigs and silver dressings for the other four. Clinical assessment of wound healing was conducted over a 6-week period. Skin samples were collected at the end of the experiment and histopathological evaluation was performed. The results show thinner scar formation and lower scar height in the debrided compared with nondebrided wounds in the hydrate gel/paraffin gauze groups. There were no statistically significant differences in wound healing assessment between the debrided and nondebrided wounds dressed with silver dressings. This study provides supporting evidence that immediate debridement with an appropriate dressing and without skin grafting may promote wound healing, suggesting its potential benefit for clinical patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This retrospective review examines healing in different sites on a porcine burn model; 24 pairs of burns on 18 pigs from other animal trials were selected for analysis. Each pair of burns was located on the either the cranial or the caudal part of the thoracic ribs region, on the same side of the animal. The burns were 40-50 cm(2) in size and of uniform deep-dermal partial thickness. Caudal burns healed significantly better than cranial burns, demonstrated by earlier closure of wounds, less scar formation and better cosmesis. To our knowledge, this is the first detailed study reporting that burn healing is affected by location on a porcine burn model. We recommend that similar symmetrical burns should be used for future comparative assessments of burn healing.

Relevância:

40.00% 40.00%

Publicador: