95 resultados para POLYMETHYLMETHACRYLATE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. 3H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. Aim: The purpose of this study was to investigate, using 3H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins. Materials and Methods: Nine disc-shaped specimens (10 x 1 mm) of each denture base resin (Lucitone 550 and QC 20) were prepared according to the manufacturers' recommendations and stored in distilled water at 37°C for 48 h. The specimens were assigned to 3 groups: 1) post-polymerization in a microwave oven for 3 min at 500 W; 2) post-polymerization in water-bath at 55°C for 60 min; and 3) without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle's medium and incubated at 37°C for 24 h. The cytotoxic effect of the eluates was evaluated by 3H-thymidine incorporation. Results: The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (p<0.05). Compared to the group with no heat treatment, water-bath decreased the cytotoxicity of the denture base acrylic resins. Conclusion: The in vitro cytotoxicity of the tested denture base materials was not influenced by microwave post-polymerization heat treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased use of orofacial fillers in cosmetic procedures has led to new diagnostic challenges for dentists and oral pathologists. Here, we describe a case with multiple oral foreign body granulomas, which were formed after a polymethylmetacrylate injection for cosmetic purposes. © 2011 European Association for Cranio-Maxillo-Facial Surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A segmental defect of 6mm diameter was performed in the medial metaphyseal region of the tibia of 12 rabbits. For the bone defect reconstruction there was implanted a combination of micro and macro fragments of heterologous fragmented cortical bone matrix preserved in glycerin (98%) and polymethylmethacrylate, both autoclaved. Radiological and macroscopic evaluation was performed at 30, 60, 90 and 120 days. Adhesion in relation to time of the micro and macro composites to the recipient bed was observed in 100% of the cases. This showed that this implant is biologically biocompatible, since it promoted bone defects repair, with no signs of infection, migration and/or rejection. In this way, this implant can be classified as one more option of substitute to fill large bone defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the opacity of the polymethylmethacrylate for ocular prosthesis using an ocular button, a colorless resin for the ocular prostheses, and 4 brands of acrylic colorless resin in the function of weathering (0, 504, or 1008 h) and thickness (1 and 3.5 mm). One hundred twenty specimens were confectioned (made) and allocated into 12 groups (n = 10). Opacity analysis was carried out with a spectrophotometer of visible ultraviolet reflection before and after weathering by 504 and 1008 hours. Data for the opacity were expressed in ΔE. Data were then analyzed statistically by analysis of variance and the Tukey test (P < 0.01). The data demonstrated statistically significant differences; manufactured ocular button (ΔE = 47.4) and the resin Vipi Cril (ΔE = 38.11) presented greater and minor values of opacity, respectively. The weathering showed statistical difference among times (0 h, ΔE = 36.32; 504 h, ΔE = 39.98; and 1008 h, ΔE = 43.9). Ocular button and evaluated resins presented greater values of opacity when presented in 3.5 mm in thickness. The values of opacity increased with the progression of the time of weathering, independent of the evaluated material and the thickness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is special interest in the incorporation of metallic nanoparticles in a surrounding dielectric matrix for obtaining composites with desirable characteristics such as for surface plasmon resonance, which can be used in photonics and sensing, and controlled surface electrical conductivity. We investigated nanocomposites produced through metallic ion implantation in insulating substrate, where the implanted metal self-assembles into nanoparticles. During the implantation, the excess of metal atom concentration above the solubility limit leads to nucleation and growth of metal nanoparticles, driven by the temperature and temperature gradients within the implanted sample including the beam-induced thermal characteristics. The nanoparticles nucleate near the maximum of the implantation depth profile (projected range), that can be estimated by computer simulation using the TRIDYN. This is a Monte Carlo simulation program based on the TRIM (Transport and Range of Ions in Matter) code that takes into account compositional changes in the substrate due to two factors: previously implanted dopant atoms, and sputtering of the substrate surface. Our study suggests that the nanoparticles form a bidimentional array buried few nanometers below the substrate surface. More specifically we have studied Au/PMMA (polymethylmethacrylate), Pt/PMMA, Ti/alumina and Au/alumina systems. Transmission electron microscopy of the implanted samples showed the metallic nanoparticles formed in the insulating matrix. The nanocomposites were characterized by measuring the resistivity of the composite layer as function of the dose implanted. These experimental results were compared with a model based on percolation theory, in which electron transport through the composite is explained by conduction through a random resistor network formed by the metallic nanoparticles. Excellent agreement was found between the experimental results and the predictions of the theory. It was possible to conclude, in all cases, that the conductivity process is due only to percolation (when the conducting elements are in geometric contact) and that the contribution from tunneling conduction is negligible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treatment of spinal fracture and luxation in small animals Traumatic spinal injuries usually result from a mechanic trauma. Spinal facture and luxations generally occur in the junction between and more mobile parts of the spinal column: close to the skull, thorax and pelvis. Fractures may occur alone or in combination with luxation as fracture/luxation. When the fractures are not stable the best solution is the surgical fixation. Internal and external fixation are the surgical methods for the treatment of vertebral fractures and luxations. The authors report the treatment of 12 cases of thoracic and lumbar vertebral fractures and luxations in small animals using the screws/pins and Polymethylmethacrylate technique. The analysis of results is a contribute I the valutation of surgical technique and complications in the post-surgical period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurden Untersuchungen zur Aufklärung des Versagens thermisch verschweißter Polymergrenzflächen (hier: Polymethylmethacrylat) durchgeführt. Solch ein Wissen kommt in der Praxis bei sogenannten Sollbruchstellen zum Einsatz. Dabei muss die Grenzschicht bis zu einer bestimmten Belastungsintensität stabil bleiben bei höherer Belastung jedoch brechen. Zudem ist eine stabile Risspropagation entlang der Grenzschicht wichtig.Neben der Bruchstabilitätsbestimmung mit Hilfe des Double Cantilever Beam Tests wurden die beim Versagen der Grenzschicht entstandenen Defekte untersucht. Die Analyse der Bruchfläche erfolgte mit Mikroskopie und Höhenprofilometrie. Defekte im Volumen wurden durch Scanning-Ultra Small Angle X-ray Scattering und Scanning Microfokus-Small Angle X-ray Scattering untersucht.Im Modellsystem können Sollbruchstellen bis zu einer Belastungsintensität von maximal 280J/m² durch die Verschweißungsdauer eingestellt werden. Die Untersuchung der Bruchflächen lieferte ein kombiniertes Modell aus Ausheil- und Interdiffusionsprozess. Ferner folgt aus den Streuuntersuchungen, dass beim Modellsystem keine hochgeordneten Defektstrukturen vorliegen. Die entstandenen Strukturen folgen einem Modell diffuser Defektgrenzflächen. Über die gemessene Diffusivität kann zudem auf die Energiedissipation im Bereich um das Rissende geschlossen werden. Sie ist im unmittelbaren Rissbereich am Höchsten und nimmt mit Entfernung davon ab. Dabei haben die Defektbereiche eine Größe bis zu 650µm. Die Richtung der von außen angelegten Belastung spielt bei der räumlichen Orientierung der Defekte keine Rolle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work is devoted to synthesis of new triazolinyl stable radical derivatives with different substituents at the 5-position of the triazolinyl ring. Obtained results showed great influence of these substituents on the stability of the radical. Electron-rich aromatic substituents at this position stabilize the radical while electron-poor aromatics decrease the stability of the triazolinyl. The triazolinyl radicals synthesized were used as additives for kinetic investigations of controlled radical polymerization of styrene and methylmethacrylate (MMA). The studies performed showed that the more stable radicals provide better control for the polymerization of styrene. In the same time certain instability of the radical is required for realization of controlled polymerization of methylmethacrylate. Based on the kinetic investigations controlled radical polymerization of a variety of monomers including 4-vinylpyridine (4-VP), ethylmethacrylate (EMA), 2,2,2-trifluoroethylmethacrylate (FEMA) and n-butylmethacrylate (BMA)was successfully carried out. Polystyrene and polymethylmethacrylate macroinitiators prepared by triazolinyl mediated controlled radical polymerization were efficiently reinitiated in the presence of a variety of monomers leading to the formation of block copolymers. Using this method PS-b-P-4-VP, PMMA-b-PS, PMMA-b-PBMA, PMMA-b-PFEMA, and PMMA-b-Poly-tert-butylacrylate were successfully synthesized. The results obtained during this work showed the efficiency and flexibility of the method allowing preparation of a range of advanced macromolecular structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clinically, the displacement of intravertebral fat into the circulation during vertebroplasty is reported to lead to problems in elderly patients and can represent a serious complication, especially when multiple levels have to be treated. An in vitro study has shown the feasibility of removing intravertebral fat by pulsed jet-lavage prior to vertebroplasty, potentially reducing the embolization of bone marrow fat from the vertebral bodies and alleviating the cardiovascular changes elicited by pulmonary fat embolism. In this in vivo study, percutaneous vertebroplasty using polymethylmethacrylate (PMMA) was performed in three lumbar vertebrae of 11 sheep. In six sheep (lavage group), pulsed jet-lavage was performed prior to injection of PMMA compared to the control group of five sheep receiving only PMMA vertebroplasty. Invasive recording of blood pressures was performed continuously until 60 min after the last injection. Cardiac output and arterial blood gas parameters were measured at selected time points. Post mortem, the injected cement volume was measured using CT and lung biopsies were processed for assessment of intravascular fat. Pulsed jet-lavage was feasible in the in vivo setting. In the control group, the injection of PMMA resulted in pulmonary fat embolism and a sudden and significant increase in mean pulmonary arterial pressure. Pulsed jet-lavage prevented any cardiovascular changes and significantly reduced the severity of bone marrow fat embolization. Even though significantly more cement had been injected into the lavaged vertebral bodies, significantly fewer intravascular fat emboli were identified in the lung tissue. Pulsed jet-lavage prevented the cardiovascular complications after PMMA vertebroplasty in sheep and alleviated the severity of pulmonary fat embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The management of insufficiency fractures of the tibial plateau in osteoporotic patients can be very challenging, since it is difficult to achieve a stable fixation, an essential condition for the patients' early mobilization. We present a minimally invasive technique for the treatment of proximal tibial plateau fractures, "tibiaplasty", using percutaneous polymethylmethacrylate augmentation. Five osteoporotic patients (7 fractures) with a non-traumatic insufficiency tibial plateau fracture were treated with this technique at the authors' institution from 2006 to 2008. The patients' median age was 79 (range 62-88) years. The intervention was performed percutaneously under general or spinal anesthesia; after the intervention, immediate full weight bearing was allowed. The technique was feasible in all patients and no complications related to the intervention were observed. All patients reported a relevant reduction in pain, were able to mobilize with full weight bearing and would undergo the operation again. No secondary loss of reduction or progression of arthrosis was observed in radiological controls; no revision surgery was required. Our initial results indicate that tibiaplasty is a good treatment option for the management of insufficiency in tibial plateau fractures in osteoporotic patients. The technique is minimally invasive, safe and allows immediate mobilization without restrictions. In our group of patients, we found excellent early to mid-term results.