938 resultados para PHOTON EMISSION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectius: Valorar el significat dels defectes paradoxals (DP) segmentaris (captació en esforç més gran que en repòs) a la gated-SPECT (Single Photon Emission Computer Tomography) de perfusió miocàrdica amb compostos tecneciats en regions amb necrosi miocàrdica. Material i mètodes: Es van revisar 1764 SPECT de perfusió miocàrdica estrès-repòs consecutives de pacients amb infart (IM) previ i es van identificar 117 pacients (6,6%) en els quals els DPs corresponien a una regió amb necrosi miocàrdica. Es van valorar els criteris gammagràfics de viabilitat (intensitat del defecte, valor d'aquesta intensitat ponderat pel nombre de segments compromesos-VIP-, la motilitat i l'engrossiment miocàrdic sistòlic) en els segments d'aquestes regions i les característiques de l'artèria responsable en els 96 pacients en els quals s'havia practicat una coronariografia. Resultats: Es van analitzar 160 necrosis, 125 (75%) paradoxals (67 (54%) en regió AnteroSeptoApical i 58 (46%) en regió InferoLateral) i 35 (25%) no paradoxals (19 (54%) ASA i 16 ( 46%) IL). Els valors de severitat de la necrosi i del VIP van ser inferiors en l'estudi d'estrès respecte al repòs i la diferència d'aquests va ser sempre negativa, evidenciant un comportament gammagràfic paradoxal. Per contra, aquests valors van ser inferiors al repòs respecte a l'estrès en les necrosi no paradoxals posant de manifest un comportament gammagràfic de mínima o nul reversibilitat. Així mateix, es van trobar alteracions lleus en la motilitat i engrossiment de les necrosi paradoxals i moderats en les necrosi no paradoxals. Es van trobar 102 necrosis amb DP i coronariografia dels quals, 84 (88%) tenien permeabilitat a l'artèria responsable de la necrosi i 12 pacients (12%) tenien circulació colateral per compensar l'oclusió de l'artèria responsable. Conclusions: Tots els segments amb DP en regions amb necrosi complien criteris gammagràfics de viabilitat en les imatges d'estrès, considerant aquestes imatges millors per a l'avaluació d'aquest tipus de lesions. El vas responsable de la regió amb DP es trobava permeable o bé presentava circulació colateral evident en els casos en què la coronària es trobava closa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Myocardial infarction is rare in children, if it occurs, findings are almost similar to adults. In Ouchenne muscular dystrophy (OMO), ST segment displacement associated with typical chest pain can occur. We report the case of a young boy with OMO presenting symptoms suggestive of myocardial ischemia. Case report: 7 year old boy, diagnosed with OMO, eoming to the emergency department with complaints of acute chest pain, dyspnoea and anxiety the night before. Clinical examination was not remarkable, with exception of findings of the OMO. ECG showed important ST-segment elevation in right precordial leads. Major increase in troponin 1 42.33 mcg/(normal, <0.04 mcg/I) was found. Echocardiography revealed slight yskinesia of postero-septal wall without decrease in ventricular function. As acute pain had happened more han 12 hours before referral and as the child was asymptomatic, he received anti-platelets therapy. The serum level of troponin 1 declined and the ECG normalised in a few days. Cardiac catheterization did not show any coronary anomaly or eardiac dysfunction. Cardiac biopsy revealed myocardial cell damaged compatible with OMO cardiomyopathy. Tc99m myocardial single-photon emission computed tomography (SPECT) did not show any radionuclide uptake defect. Conclusions: ln this particular context of children with OMO, the classical signs of myocardial ischemia could be misleading, standard investigation failed to demonstrate the cause of chest pain and inerease of troponin l, there was also no evidence of myocarditis. Role of late enhancement (LE) signal in eontrast-enhanced MRI in the understanding of the occurring process has to be evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental studies in nude mice with human colon-carcinoma grafts demonstrated the therapeutic efficiency of F(ab')2 fragments to carcinoembryonic antigen (CEA) labeled with a high dose of 131Iodine. A phase I/II study was designed to determine the maximum tolerated dose of 131I-labeled F(ab')2 fragments (131I-F(ab')2) from anti-CEA monoclonal antibody F6, its limiting organ toxicity and tumor uptake. Ten patients with non-resectable liver metastases from colorectal cancer (9 detected by CT scan and 1 by laparotomy) were treated with 131I-F(ab')2, doses ranging from 87 mCi to 300 mCi for the first 5 patients, with a constant 300-mCi dose for the last 5 patients. For all the patients, autologous bone marrow was harvested and stored before treatment. Circulating CEA ranged from 2 to 126 ng/ml. No severe adverse events were observed during or immediately following infusion of therapeutic doses. The 9 patients with radiologic evidence of liver metastases showed uptake of 131I-F(ab')2 in the metastases, as observed by single-photon-emission tomography. The only toxicity was hematologic, and no severe aplasia was observed when up to 250 mCi was infused. At the 300-mCi dose, 5 out of 6 patients presented grade-3 or -4 hematologic toxicity, with a nadir for neutrophils and thrombocytes ranging from 25 to 35 days after infusion. In these 5 cases, bone marrow was re-infused. No clinical complications were observed during aplasia. The tumor response could be evaluated in 9 out of 10 patients. One patient showed a partial response of one small liver metastasis (2 cm in diameter) and a stable evolution of the other metastases, 2 patients had stable disease, and 6 showed tumor progression at the time of evaluation (2 or 3 months after injection) by CT scan. This phase-I/II study demonstrated that a dose of 300 mCi of 131I-F(ab')2 from the anti-CEA Mab F6 is well tolerated with bone-marrow rescue, whereas a dose of 200 mCi can be infused without severe bone-marrow toxicity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Functional brain images such as Single-Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been widely used to guide the clinicians in the Alzheimer's Disease (AD) diagnosis. However, the subjectivity involved in their evaluation has favoured the development of Computer Aided Diagnosis (CAD) Systems. METHODS It is proposed a novel combination of feature extraction techniques to improve the diagnosis of AD. Firstly, Regions of Interest (ROIs) are selected by means of a t-test carried out on 3D Normalised Mean Square Error (NMSE) features restricted to be located within a predefined brain activation mask. In order to address the small sample-size problem, the dimension of the feature space was further reduced by: Large Margin Nearest Neighbours using a rectangular matrix (LMNN-RECT), Principal Component Analysis (PCA) or Partial Least Squares (PLS) (the two latter also analysed with a LMNN transformation). Regarding the classifiers, kernel Support Vector Machines (SVMs) and LMNN using Euclidean, Mahalanobis and Energy-based metrics were compared. RESULTS Several experiments were conducted in order to evaluate the proposed LMNN-based feature extraction algorithms and its benefits as: i) linear transformation of the PLS or PCA reduced data, ii) feature reduction technique, and iii) classifier (with Euclidean, Mahalanobis or Energy-based methodology). The system was evaluated by means of k-fold cross-validation yielding accuracy, sensitivity and specificity values of 92.78%, 91.07% and 95.12% (for SPECT) and 90.67%, 88% and 93.33% (for PET), respectively, when a NMSE-PLS-LMNN feature extraction method was used in combination with a SVM classifier, thus outperforming recently reported baseline methods. CONCLUSIONS All the proposed methods turned out to be a valid solution for the presented problem. One of the advances is the robustness of the LMNN algorithm that not only provides higher separation rate between the classes but it also makes (in combination with NMSE and PLS) this rate variation more stable. In addition, their generalization ability is another advance since several experiments were performed on two image modalities (SPECT and PET).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Migraine is a chronic neurologic disease that can severely affect the patient's quality of life. Although in recent years many randomised studies have been carried out to investigate the effectiveness of acupuncture as a treatment for migraine, it remains a controversial issue. Our aim is to determine whether acupuncture, applied under real conditions of clinical practice in the area of primary healthcare, is more effective than conventional treatment. METHODS/DESIGN The design consists of a pragmatic multi-centre, three-armed randomised controlled trial, complemented with an economic evaluation of the results achieved, comparing the effectiveness of verum acupuncture with sham acupuncture, and with a control group receiving normal care only. Patients eligible for inclusion will be those presenting in general practice with migraine and for whom their General Practitioner (GP) is considering referral for acupuncture. Sampling will be by consecutive selection, and by randomised allocation to the three branches of the study, in a centralised way following a 1:1:1 distribution (verum acupuncture; sham acupuncture; conventional treatment). Secondly, one patient in three will be randomly selected from each of the acupuncture (verum or sham) groups for a brain perfusion study (by single photon emission tomography). The treatment with verum acupuncture will consist of 8 treatment sessions, once a week, at points selected individually by the acupuncturist. The sham acupuncture group will receive 8 sessions, one per week, with treatment being applied at non-acupuncture points in the dorsal and lumbar regions, using the minimal puncture technique. The control group will be given conventional treatment, as will the other two groups. DISCUSSION This trial will contribute to available evidence on acupuncture for the treatment of migraine. The primary endpoint is the difference in the number of days with migraine among the three groups, between the baseline period (the 4 weeks prior to the start of treatment) and the period from weeks 9 to 12. As a secondary aspect, we shall record the index of laterality and the percentage of change in the mean count per pixel in each region of interest measured by the brain perfusion tomography, performed on a subsample of the patients within the real and sham acupuncture groups. TRIAL REGISTRATION Current Controlled Trials ISRCTN98703707.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human cytosolic thymidine kinase (hTK1) has proven to be a suitable target for the noninvasive imaging of cancer cell proliferation using radiolabeled thymidine analogues such as [(18)F]3'-fluoro-3'-deoxythymidine ([(18)F]FLT). A thymidine analogue for single photon emission computed tomography (SPECT), which incorporates the readily available and inexpensive nuclide technetium-99m, would be of considerable practical interest. hTK1 is known to accommodate modification of the structure of the natural substrate thymidine at the positions N3 and C3' and, to a lesser extent, C5. In this work, we used the copper-catalyzed azide-alkyne cycloaddition to synthesize two series of derivatives in which thymidine is functionalized at either the C3' or N3 position with chelating systems suitable for the M(CO)(3) core (M = (99m)Tc, Re). The click chemistry approach enabled complexes with different structures and overall charges to be synthesized from a common precursor. Using this strategy, the first organometallic hTK1 substrates in which thymidine is modified at the C3' position were identified. Phosphorylation of the organometallic derivatives was measured relative to thymidine. We have shown that the influence of the overall charge of the derivatives is dependent on the position of functionalization. In the case of the C3'-functionalized derivatives, neutral and anionic substrates were most readily phosphorylated (20-28% of the value for the parent ligand thymidine), whereas for the N3-functionalized derivatives, cationic and neutral complexes were apparently better substrates for the enzyme (14-18%) than anionic derivatives (9%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rupture of unstable plaques may lead to myocardial infarction or stroke and is the leading cause of morbidity and mortality in western countries. Thus, there is a clear need for identifying these vulnerable plaques before the rupture occurs. Atherosclerotic plaques are a challenging imaging target as they are small and move rapidly, especially in the coronary tree. Many of the currently available imaging tools for clinical use still provide minimal information about the biological characteristics of plaques, because they are limited with respect to spatial and temporal resolution. Moreover, many of these imaging tools are invasive. The new generation of imaging modalities such as magnetic resonance imaging, nuclear imaging such as positron emission tomography and single photon emission computed tomography, computed tomography, fluorescence imaging, intravascular ultrasound, and optical coherence tomography offer opportunities to overcome some of these limitations. This review discusses the potential of these techniques for imaging the unstable plaque.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim of the present article was to perform three-dimensional (3D) single photon emission tomography-based dosimetry in radioimmunotherapy (RIT) with (90)Y-ibritumomab-tiuxetan. A custom MATLAB-based code was used to elaborate 3D images and to compare average 3D doses to lesions and to organs at risk (OARs) with those obtained with planar (2D) dosimetry. Our 3D dosimetry procedure was validated through preliminary phantom studies using a body phantom consisting of a lung insert and six spheres with various sizes. In phantom study, the accuracy of dose determination of our imaging protocol decreased when the object volume decreased below 5 mL, approximately. The poorest results were obtained for the 2.58 mL and 1.30 mL spheres where the dose error evaluated on corrected images with regard to the theoretical dose value was -12.97% and -18.69%, respectively. Our 3D dosimetry protocol was subsequently applied on four patients before RIT with (90)Y-ibritumomab-tiuxetan for a total of 5 lesions and 4 OARs (2 livers, 2 spleens). In patient study, without the implementation of volume recovery technique, tumor absorbed doses calculated with the voxel-based approach were systematically lower than those calculated with the planar protocol, with average underestimation of -39% (range from -13.1% to -62.7%). After volume recovery, dose differences reduce significantly, with average deviation of -14.2% (range from -38.7.4% to +3.4%, 1 overestimation, 4 underestimations). Organ dosimetry in one case overestimated, in the other underestimated the dose delivered to liver and spleen. However, both for 2D and 3D approach, absorbed doses to organs per unit administered activity are comparable with most recent literature findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Adoptive transfer therapy of in vitro-expanded tumor-specific cytolytic T lymphocytes (CTLs) can mediate objective cancer regression in patients. Yet, technical limitations hamper precise monitoring of posttherapy T cell responses. Here we show in a mouse model that fused single photon emission computed tomography and x-ray computed tomography allows quantitative whole-body imaging of (111)In-oxine-labeled CTLs at tumor sites. Assessment of CTL localization is rapid, noninvasive, three-dimensional, and can be repeated for longitudinal analyses. We compared the effects of lymphodepletion before adoptive transfer on CTL recruitment and report that combined treatment increased intratumoral delivery of CTLs and improved antitumor efficacy. Because (111)In-oxine is a Food and Drug Administration-approved clinical agent, and human SPECT-CT systems are available, this approach should be clinically translatable, insofar as it may assess the efficacy of immunization procedures in individual patients and lead to development of more effective therapies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (< or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.