982 resultados para Osseointegration fixation


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genotypic differences on growth and yield of common bean (Phaseolus vulgaris L.) in response to P supply were evaluated in a field experiment under biological N2 fixation. Eight cultivars were grown at two levels of applied P (12 and 50 kg ha-1 of P -- P1 and P2 respectively), in randomized block design in factorial arrangement. Vegetative biomass was sampled at three ontogenetic stages. The effects of genotype and phosphorus were significant for most traits, but not the genotype ´ phosphorus interaction. The cultivars presented different patterns of biomass production and nutrient accumulation, particularly on root system. At P1, P accumulation persisted after the beginning of pod filling, and P translocation from roots to shoots was lower. The nodule senescence observed after flowering might have reduced N2 fixation during pod filling. The responses of vegetative growth to the higher P supply did not reflect with the same magnitude on yield, which increased only 6% at P2; hence the harvest index was lower at P2. The cultivars with highest yields also presented lower grain P concentrations. A sub-optimal supply of N could have limited the expression of the yield potential of cultivars, reducing the genotypic variability of responses to P levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to investigate the effect of water stress on N2 fixation and nodule structure of two common bean (Phaseolus vulgaris L.) cultivars Carioca and EMGOPA-201. Plants were harvested after five and eight days of water stress. Carioca had lower nodule dry weight on both water stress periods; shoot dry weight was lower at five days water stress and did not differ from control after eight days stress. Both cultivars had lower nitrogenase activity than control after five and eight days water stress. For both cultivars, after eight days stress bacteroid membranes were damaged. Carioca presented more pronounced damage to infected tissue, with host cell vacuolation and loss of the peribacteroid membrane at five days after stress; at eight days after stress, there was degradation of cytoplasm host cells and senescence of bacteroids, with their release into intercellular spaces. Intensity of immunogold-labeling of intercellular cortical glycoprotein with the monoclonal antibodies MAC 236/265 was different for both cultivars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical fertilisers are rarely avaiable to poor farmers, for whom the nitrogen (N) is often the most limiting element for cereal grain production. The objective of this study was to quantify the contribution of biological nitrogen fixation (BNF) to groundnut (Arachis hypogaea) and velvet bean (Mucuna pruriens) crops using the 15N natural abundance (delta15N) technique and to determine their residual effect and that of a natural fallow, on growth and N accumulation by two rustic maize varieties. The contribution of BNF calculated from delta15N data was 40.9, 59.6 and 30.9 kg ha-1, for groundnut, velvet bean and the natural fallow, respectively. The only legume grain harvested was from the groundnut, which yielded approximately 1.000 kg ha-1. The subsequent maize varieties ("Sol de Manhã" and "Caiana Sobralha") yielded between 1.958 and 2.971 kg ha-1, and were higher after velvet bean for both maize varieties and "Sol da Manhã" groundnut, followed by "Caiana" after groundnut and, finally, the natural fallow. For a small-holder producer the most attractive system is the groundnut followed by maize, as, in this treatment, both groundnut and maize grain harvest are possible. However, a simple N balance calculation indicated that the groundnut-maize sequence would, in the long term, deplete soil N reserves, while the velvet bean-maize sequence would lead to a build up of soil nitrogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To review, retrospectively, the possible causes of sub- or intertrochanteric fractures after screw fixation of intracapsular fractures of the proximal femur. METHODS: Eighty-four patients with an intracapsular fracture of proximal femur were operated between 1995 and 1998 by using three cannulated 6.25 mm screws. The screws were inserted in a triangular configuration, one screw in the upper part of the femoral neck and two screws in the inferior part. Between 1999 and 2001, we use two screws proximally and one screw distally. RESULTS: In the first series, two patients died within one week after operation. Sixty-four fractures healed without problems. Four patients developed an atrophic non-union; avascular necrosis of the femoral head was found in 11 patients. Three patients (3.6%) suffered a sub- and/or intertrochanteric fracture after a mean postoperative time of 30 days, in one case without obvious trauma. In all three cases surgical revision was necessary. Between 1999 and 2001 we did not observe any fracture after screwing. CONCLUSION: Two screws in the inferior part of the femoral neck create a stress riser in the subtrochanteric region, potentially inducing a fracture in the weakened bone. For internal fixation for proximal intracapsular femoral fracture only one screw must be inserted in the inferior part of neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighteen patients with acetabular fractures, with a mean age of 76 years, were treated with cable fixation and acute total hip arthroplasty. Nine were T-shaped fractures, 4 associated transverse and posterior wall, 2 transverse, 2 posterior column and posterior wall, and 1 anterior and posterior hemitransverse fractures. One patient experienced 3 episodes of hip dislocation within 10 months after surgery. All the others had a good outcome at a mean follow-up time of 36 months. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This option provides good primary fixation, stabilizes complex acetabular fractures in elderly patients, and permits early postoperative mobilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares the direct and indirect costs of conservative and minimally invasive treatment for undisplaced scaphoid fractures. Costs data concerning groups of non-operated and operated patients were analysed. Direct costs were higher in operated patients. Although highly variable, indirect costs were significantly smaller in operated patients and the total costs were higher in non-operated patients. In conclusion, operative treatment of scaphoid fractures is initially more expensive than conservative treatment but markedly decreases the work compensation costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a modification of intraoperative external fixation for mandibular reconstruction with free tissue flaps. This technique is indicated when preregistration of the reconstruction plate is not possible due to transmandibular tumor extension. Once standard external fixation has been carried out and prior to segmental mandibulectomy, additional pins are fixed to the connecting rod that delineate the mandibular contour in three-dimensional (3D) space. Following mandibulectomy, these pins allow accurate contouring of the reconstruction plate and improved restoration of mandibular contour, projection, and dental occlusion. A step-by-step description of the technique using models and intraoperative photos is presented. This method of mandibular reconstruction is a simple and time-effective alternative to intraoperative computer navigation and 3D modeling in select cases of oral carcinoma where tumor infiltration of the outer mandibular cortex precludes prebending of the reconstruction plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to genetically characterize four new Rhizobium strains, and to evaluate their nodulation and fixation capacity compared to commercial strains and to native rhizobia population of a Brazilian Rhodic Hapludox. Two experiments were carried out in randomized blocks design, under greenhouse conditions, in 2007. In the first experiment, the nodulation and nitrogen fixation capacity of new strains were evaluated, in comparison to the commercial strains CIAT-899 and PRF-81 and to native soil population. It was carried out in plastic tubes filled with vermiculite. DNA extractions and PCR sequencing of the intergenic space were made from the isolated pure colonies, in order to genetically characterize the strains and the native rhizobia population. In the second experiment, the nodulation and productivity of common beans Perola cultivar were determined, with the use of evaluated strains, alone or in mixture with PRF-81 strain. It was carried out in pots filled with soil. The native soil population was identified as Rhizobium sp. and was inefficient in nitrogen fixation. Three different Rhizobium species were found among the four new strains. The LBMP-4BR and LBMP-12BR new strains are among the ones with greatest nodulation and fixation capacity and exhibit differential responses when mixed to PRF-81.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rb fusions between acrocentric chromosomes leading to metacentrics tend to become fixed during the chromosomal evolution in the common shrew. Using microsatellite markers preliminary results show that populations are only slightly subdivided and genetic drift seems not to play an important role for the fixation of metacentrics. A significant segregation distortion in favour of metacentric chromosomes was found during male meiosis. This suggests that cytological factors such as facilitated fusion between acrocentric chromosomes or choice-effects at the level of gametes are more likely to play a role for the chromosomal evolution in the common shrew.