975 resultados para Operative surgical procedure
Resumo:
Background: Gynaecomastia in male goats is characterized by abnormal development of the mammary gland. Enlarged udder may be observed cranially to the scrotum, which can occasionally reach the size of the testicles. The udder may carry functional glands and impair the animal's reproductive performance and welfare. The case of a successful surgical treatment of gynaecomastia in a high reproductive performance Saanen buck-goat is reported in the present study.Material, Methods & Results: The animal was admitted presenting significant augmentation of the mammary glands, which was clinically diagnosed as gynaecomastia. The male goat owned optimal phenotypic characteristics for the Saanen breed, which had been producing high performance descendents. The mammary glands had been impairing the goat's locomotion and sexual performance. Manual milking resulted in great amount of milk secretion. The animal presented anorexia and impaired sexual performance. After clinical and laboratorial evaluation, the animal was submitted to radical mastectomy. An elliptic skin incision was performed around each mammary gland. Subcuticular blunt dissection was accomplished to isolate the mammarian tissue from the abdominal muscular layer and the spermatic chord. The excised mass was sampled for histological assessment. Subcuticular layer and skin closure was carried in a routine fashion. Hygienization of the surgical wound was performed with 2,5% PVP-I solution for ten days. Additionally, an association of penicillin G benzathine and streptomycin, and fluxinin meglumine were also given. The surgical procedure was successfully accomplished without any peroperative complication. The excised mass was sampled for anatomic/histological assessment. Macroscopically, the left mammary gland presented 22 cm in length, 12 cm wide and 26 cm in diameter. The right gland presented 16 cm in length, 7 cm wide and 13,5 cm in diameter. The microscopic assessment revealed hyperplasia of the glandular ducts. No abnormalities resembling malignant mammary neoplasms or degeneration were observed. At the end of the treatment, the animal was completely recovered. The animal convalesced satisfactorily and surgical wound healed completely within the first 10 days post-op. The goat was not culled and returned to normal reproductive activity. Within 12 months of follow-up, the animal was able to produce high milk yield performance progenies.Discussion: This case report presented relevant aspects of the surgical management of gynaecomastia, especially to veterinary practitioners dealing with milk goats. Gynaecomastia is not as common as other reproductive disorders in domestic animals. In opposition to the findings of the present study, other trials revealed that gynaecomastia usually does not affect fertility, libido, ejaculate parameters and sexual performance of goats. However, it is important to consider that neoplasic disorders such as mammary adenocarcinoma may be present, even though these are rare complications. Last but not least, the decision making on mastectomy in the present study was crucial in order to reestablish the animal's welfare and its functionality in the farms reproduction program.
Resumo:
OBJETIVO: Avaliar a evolução pós-operatória de pacientes com divertículo faringoesofagiano submetidos aos tratamentos cirúrgico e endoscópico. MÉTODOS: Foram analisados de maneira retrospectiva 36 pacientes com divertículo faringo-esofagiano atendidos no Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP. Os pacientes foram distribuídos em dois grupos, na dependência do tratamento: grupo 1 (n=24) - diverticulectomia associada á miotomia do cricofaríngeo, através de cervicotomia esquerda; grupo 2 (n=12) - diverticulostomia endoscópica usando grampeador linear. RESULTADOS: A mortalidade operatória foi nula em ambos os grupos. Complicações precoces: grupo 1 - dois pacientes desenvolveram fistula cervical e outros dois, rouquidão; grupo 2 - sem complicações. Complicações tardias: grupo 1 - sem complicações: grupo 2: recidiva da disfagia em quatro pacientes (p=0,01). O seguimento médio foi 33 meses para o grupo 1 e 28 meses para o grupo 2. CONCLUSÃO: Os dois procedimentos foram eficazes na remissão da disfagia. O tratamento cirúrgico apresentou superioridade em relação ao endoscópico, com resolução da disfagia com um único procedimento. O tratamento endoscópico deve ser reservado para os mais idosos e portadores de comorbidades.
Resumo:
Background: Locally advanced breast cancer (LABC) is still common in developing countries. The association between neoadjuvant chemotherapy (NC) and oncoplastic surgery (OS) might provide an oncological treatment with satisfactory aesthetic results.Purpose: The goal was to demonstrate if oncoplastic surgical techniques can be utilized to treat LABC which was submitted to neoadjuvant chemotherapy.Methods: This prospective clinical trial included breast cancer patients, clinical stage III, who underwent established NC regimen. All patients underwent preoperative planning to control the tumor size and to define the surgical technique. A detailed analysis of the pathological specimen was performed.Results: 50 patients were assessed and surgically treated. Tumor size ranged from 3.0 to 14.0 cm (median 6.5 cm). Pathologic response was rated as stable, progressive, partial response, and complete response in 10%, 8%, 80% and 2% of the cases, respectively. Seventeen (34%) patients were submitted to OS. No patient had positive margins. Skin involvement was presented in 36% of pathologic specimen.Conclusions: Oncoplastic surgical techniques for selected patients decrease the rates of radical surgery despite large tumors. (www.clinicaltrials.gov, NCT00820690). (C) 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: This article reports a clinical case with a 3-year follow-up in which a subepithelial connective tissue graft (SCTG) was used with the tunnel technique to treat multiple gingival recessions, and describes a technique used to enlarge the extension of the graft.Methods: A 41 -year-old female patient was referred for evaluation and treatment of maxillary multiple recessions. Following basic therapy, the plaque index was 23%, and the gingival index was 12%. Thus, SCTG with the tunnel technique was proposed to provide root coverage of Miller Class I recession on teeth #8 through #11 and a Miller Class III recession on tooth #12. After the donor area had been prepared, SCTG was removed and split cross-sectionally to lengthen it. The graft was placed through the tunnel and sutured.Results: Two weeks after the surgical procedure, the tissue color was nearly homogeneous with some reddish regions where the connective tissue was left uncovered, and there were no signs of incisions or suture marks. After 3 years of follow-up, the mean coverage of the recessions was 2.2 +/- 0.7 mm (74.2%), which corresponded to the gain of keratinized tissue. In addition, a gain in tissue thickness was observed.Conclusion: In a long-term evaluation, the tunnel technique with the elongated SCTG was used successfully for treatment of multiple gingival recessions with an increase of the soft tissue volume and gain of keratinized tissue.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A intubação traqueal associada a operações das vias aéreas faz com que complicações como laringoespasmo, broncoespasmo e períodos de redução da saturação de oxigênio sejam frequentemente relatados em adenotonsilectomias, procedimento que, por sua natureza, eleva a incidência de tais complicações. O objetivo deste estudo foi analisar a ocorrência de problemas respiratórios comparando-se o uso da máscara laríngea (ML) descartável com a intubação orotraqueal em adenotonsilectomias. MÉTODOS: Foram avaliados 204 pacientes pediátricos submetidos a anestesia geral para adenotonsilectomias e alocados em dois grupos, aleatoriamente: grupo Cânula Traqueal (CT, n = 100) e grupo Máscara Laríngea (ML, n = 104). Foram observados os níveis de saturação de pulso de oxigênio (SpO2) após a indução anestésica (SpO2-1), após o estabelecimento de campo operatório (SpO2-2), ao término do procedimento cirúrgico (SpO2-3), três minutos após a retirada do dispositivo respiratório (SpO2-4) e na admissão da sala de recuperação anestésica (SpO2-5). As complicações respiratórias foram relatadas. RESULTADOS: Os valores médios e os desvios padrão de SpO2 nos grupos CT e ML foram, respectivamente: SpO2-1: 98,9 ± 1,0 e 98,7 ± 0,8 (p > 0,25); SpO2-2: 97,4 ± 1,0 e 94,9 ± 4,3 (p < 0,001); SpO2-3: 96,9 ± 1,1 e 97,2 ± 1,1 (p = 0,037); SpO2-4: 91,7 ± 9,0 e 95,2 ± 2,2 (p < 0,001); SpO2-5: 94,0 ± 2,1 e 95,8 ± 2,6 (p < 0,001). No grupo ML, em 12 pacientes, foi necessária alguma manobra para ajuste do dispositivo e correção de vazamento durante o ato operatório. A ML foi substituída pela CT em quatro pacientes. As complicações respiratórias foram similares entre os grupos. CONCLUSÕES: Adenotonsilectomias em pacientes pediátricos com o emprego da ML, em comparação com a CT, resulta em menores valores de SpO2 intraoperatórios e, eventualmente, necessidade de substituição da ML pela CT. Apesar de a ML viabilizar a cirurgia, pela segurança, o uso da CT é preferível.
Resumo:
OBJETIVO: Analisar o efeito das fundoplicaturas total e parcial sobre a pressão e comprimento do esfíncter inferior do esôfago (EIE). MÉTODOS: Foram estudados 30 coelhos machos da raça Norfolk. Os animais foram divididos em 3 grupos de 10, na dependência da operação[cirurgia] realizada. Grupo 1 (controle)-laparotomia mediana (LM) e dissecção da transição gastroesofágica; grupo 2- LM e fundoplicatura total, e grupo 3-LM e fundoplicatura parcial. Todos os animais foram submetidos à manometria esofágica (ME) segundo a técnica de tração intermitente da sonda e infusão contínua dos cateteres com água destilada. A ME foi realizada em dois momentos: M1 (pré-operatório) e M2 (pós-operatório), e permitiu a análise da pressão (mmHg) e comprimento (cm) do EIE. RESULTADOS: Nos animais do grupo 1 não foi observada alteração da pressão e comprimento do EIE. Naqueles do grupo 2 (fundoplicatura total) foi observado aumento da pressão (69,7%) e do comprimento (81,8%) do EIE. Nos coelhos do grupo 3 (fundoplicatura parcial) houve aumento da pressão (58%) e do comprimento (100%) do EIE. CONCLUSÕES: As fundoplicaturas total e parcial acarretam aumento da pressão e comprimento de EIE. O incremento da pressão e comprimento de EIE independe do tipo de fundoplicatura utilizada.
Resumo:
Background: Orbital infection is an uncommon devastating infection and is usually a complication of paranasal sinus infection. Without appropriate treatment, orbital infection may lead to serious complications, even death. Prompt treatment is mandatory to avoid visual loss or intracranial complications. The literature shows that initially, intravenous antibiotics should be administered, and after 48 h, if no improvement appears, the affected orbit and the sinuses must be surgically drained. The authors describe two cases of orbital cellulitis with a brief literature review. Case report: The authors describe two cases of orbital abscess caused by paranasal sinus infection. In case 1, the patient presented a decreased visual acuity associated with ophthalmoplegia of the right eye. In case 2, the patient presented a decreased visual acuity. Thus, administration of intravenous antibiotic combined with surgical drainage was performed. After surgical procedure, eye movements were normalized in case 1, and in both patients, the visual acuity returned to normal parameters. Discussion: The authors recommend early surgical drainage with parenteral antibiotic administration and careful postoperative observations by monitoring the signs and symptoms of the orbital complaint. © 2012 Springer-Verlag.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Anestesiologia - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Cherubism is a rare autosomal-dominant inherited syndrome and is usually self-limiting; it starts in early childhood and involutes by puberty. It is a benign fibroosseous disease, characterized by excessive bone degradation of the upper and lower jaws followed by development of fibrous tissue masses. The purpose of this clinical report is to describe a rare and aggressive form of cherubism on an adult female patient that has been treated in our Bioscience Center for Special Health Care Needs-CEBAPE. The patient was firstly submitted to the surgical procedure with partial curettage of the lesion, and the cavity was filled with autogenous cancellous bone and bone marrow grafts. Furthermore, the support treatment used was the administration of salmon calcitonin by nasal spray during the first year after the preconized procedure. At 4-year followup, we confirmed the stomatognathic system improvement and esthetic rehabilitation, which led to a significant increase in the patient's quality of life.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.