799 resultados para Objective visual acuity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). SETTING: The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. RESULTS: The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). CONCLUSIONS: Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To study the visual acuity and astigmatism of persons undergoing cataract extraction by local surgeons in rural China. METHODS: Visual acuity, keratometry, and refraction were measured 10 to 14 months postoperatively for all cataract cases during 4 months in Sanrao, China. RESULTS: Among 313 eligible subjects, 242 (77%) could be contacted, of whom 176 (73%) were examined. Of those who were examined, mean +/- SD age was 69.3 +/- 10.5 years, 66.5% were female, 35 had been operated on bilaterally at Sanrao, and 85.2% had a preoperative presenting visual acuity of 6/60 or worse. Presenting and best-corrected postoperative acuity in the eye that was operated on were 6/18 or better in 83.4% and 95.7%, respectively. Among 27 fellow eyes operated on elsewhere, 40.7% had a presenting acuity of 6/18 or better and 40.7% were blind (P < .001). Mean +/- SD postoperative astigmatism did not differ between 211 eyes that were operated on (-1.13 +/- 0.84 diopters) and 109 eyes that were not (-1.13 +/- 1.17 diopters; P = .27). Presence of operative complications (8.5%) and older age were associated with worse vision; bilateral surgery was associated with better vision. CONCLUSIONS: These results confirm the effectiveness of skill transfer in this setting, with superior outcomes to most studies in rural Asia and to eyes in this cohort operated on at other facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: determinar los diferentes factores clínicos y de imagen pronósticos para la agudeza visual final a los 3, 6 y 12 meses en los pacientes con oclusiones venosas retinianas tratados con terapia antiangiogénica. Material y métodos: estudio longitudinal de una cohorte de 60 pacientes con oclusión venosa retiniana tratados con terapia antiangiogénica intravitrea con ranibizumab y bevacizumab tomados retrospectivamente entre 2010 y 2012. Posteriormente se realizó un estudio analítico de cohorte retrospectiva, para establecer la asociación y predicción de los cambios de la agudeza visual. Resultados: se encontró una diferencia estadísticamente significativa entre la línea base, 3, 6 y 12 meses post tratamiento. (p < 0.001, prueba de Friedman). En el modelo explicativo de los cambios de la agudeza visual a los 3, 6 y 12 meses con la línea base, se encontró asociación significativa la presencia de IS/OS a los 3 meses con los cambios de la agudeza visual a los 6 meses (r2=.232, p< 0.001) y a los 12 meses (r2=.506, p< 0.001), en este último también se encontró asociado el género masculino (r2=.277 p< 0.001). Tomando los valores de la agudeza visual a los 3,6 y 12 meses y como covariable la agudeza visual inicial se encontró asociación significativa en los tres momentos, 3 meses (r2=0.697, p< 0.001), 6 meses (r2=745, p< 0.001) y 12 meses y (r2=786, p< 0.001), se encontró asociación significativa el presentar oclusión venosa de rama comparada con oclusión central con los cambios de la agudeza visual a los 6 meses (r2=.662, p=0.04) Conclusión: la presencia de IS/OS a los 3 meses y la agudeza visual inicial tienen una alta capacidad predictora de la agudeza visual a los 6 y 12 meses, el género masculino tiene relación con mejoría de la agudeza visual final y la oclusión de rama tiene relación con la mejoría de la agudeza visual a 6 meses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: Varias características pueden afectar el pronóstico visual después de resolver quirúrgicamente el desprendimiento de retina. Existen características no observables por el ojo humano por si solo pero si por tomografía óptica coherente que se relacionan con la recuperación visual. Objetivo: Describir las características clínicas y topográfica en los periodos pre y postquirúrgico de ojos que ha sufrido DR regmatógeno con compromiso macular y su relación con la calidad de recuperación visual después de una cirugía considerada exitosa desde el punto de vista anatómico. Materiales y métodos: Estudio descriptivo en el que se comparan algunas características en tres periodos perioeperatorios, uno antes y dos después de cirugía (3 y 6 meses) de 24 ojos con DRregmatógeno y compromiso macular intervenidos mediante retinopexia combinada con vitrectomía pars plana. Resultados: La recuperación visual mejor o igual que logMAR 0,397 (20/50) se dió en 41,7% de ojos y 16,7%. alcanzaron agudeza visual logMAR 0,301 (20/40). Cinco ojos no alcanzaron una ganancia de líneas de visión mayor a cinco. El líquido submacular ausente se observó en la mayoría de ojos que recuperaron más de cinco líneas al igual que aquellos con elipsoide conservado. La regularidad del neuroepitelio y el edema en el periodo posquirúrgico no mostraron comportamientos claros respecto a recuperación visual al igual que la altura del desprendimiento y el número de cuadrantes afectados. Una mejor recuperación visual fue más frecuente en aquellos con menos de cinco semanas de desprendimiento de retina. Conclusiones: El retraso menor a cinco semanas en la resolución del desprendimiento de retina, la conservación del elipsoide y la ausencia de líquido submacular en el periodo postquirúrgico se observó más frecuentemente en ojos con mejor recuperación visual.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Establecer la correlación entre condiciones de iluminación, ángulo visual, discriminación de contrastes y agudeza visual en la aparición de síntomas visuales en operarios de computador. Materiales y métodos: Estudio de corte transversal y correlación en muestra de 136 trabajadores administrativos de un “call center” perteneciente a una entidad de salud en la ciudad de Bogotá, utilizando un cuestionario con el que se evaluaron las variables sociodemográficas y ocupacionales; aplicando la escala de síntomas visión – computador (CVSS17), realizando evaluación médica y midiendo iluminación y distancia operario pantalla de computador y con los datos recolectados se realizó un análisis estadístico bivariado y se estableció la correlación entre las condiciones de iluminación, ángulo visual, discriminación de contrataste y agudeza visual; frente a la aparición de síntomas visuales asociados con el uso del computador. El análisis se llevó a cabo con medidas de tendencia central y dispersión y con el coeficiente de correlación paramétrico de Pearson o no-paramétrico de Spearman, previamente se evaluó la normalidad con la prueba de Shapiro-Wilk. Las pruebas estadísticas se evaluarán a un nivel de significancia del 5% (p<0.05). Resultados: El promedio de edad de los participantes en el estudio fue de 36,3 años con un rango entre los 22 y 57 años y en donde el género predominante fue el femenino con el 79,4%. Se encontraron síntomas visuales asociados al uso de pantalla de computador del 59,6%, siendo los más frecuentes la epifora (70,6%), fotofobia (67,6%) y ardor ocular (54,4%). Se reportó una correlación inversa significativa entre niveles de iluminación y manifestación de fotofobia (p=0.02; r= 0,262). Por otra parte no se encontró correlación significativa entre los síntomas referidos con ángulo de visión y agudeza visual y discriminación de contrastes. Conclusión: Las condiciones laborales de iluminación del grupo de estudio están relacionadas con la manifestación de fotofobia, Se encontró asociación entre síntomas visuales y variables sociodemográficas, específicamente con el género, fotofobia a pantalla, fatiga visual y fotofobia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare subjective and objective visual performance of the Air Optix Aqua Multifocal lens to monovision in a group of subjects requiring a medium level of reading-addition power.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi estimar a entropia conjunta do sistema visual humano no domínio do espaço e no domínio das freqüências espaciais através de funções psicométricas. Estas foram obtidas com testes de discriminação de estímulos com luminância ou cromaticidade moduladas por funções de Gábor. A essência do método consistiu em avaliar a entropia no domínio do espaço, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em extensão espacial, e avaliar a entropia no domínio das freqüências espaciais, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em freqüência espacial. A entropia conjunta foi calculada, então, a partir desses dois valores individuais de entropia. Três condições visuais foram estudadas: acromática, cromática sem correção fina para eqüiluminância e cromática com correção para eqüiluminância através de fotometria com flicker heterocromático. Quatro sujeitos foram testados nas três condições, dois sujeitos adicionais foram testados na condição cromática sem eqüiluminância fina e um sétimo sujeito também fez o teste acromático. Todos os sujeitos foram examinados por oftalmologista e considerados normais do ponto de vista oftálmico, não apresentando relato, sintomas ou sinais de disfunções visuais ou de moléstias potencialmente capazes de afetar o sistema visual. Eles tinham acuidade visual normal ou corrigida de no mínimo 20/30. O trabalho foi aprovado pela Comissão de Ética em Pesquisa do Núcleo de Medicina Tropical da UFPA e obedeceu às recomendações da Declaração de Helsinki. As funções de Gábor usadas para modulação de luminância ou cromaticidade compreenderam redes senoidais unidimensionais horizontais, moduladas na direção vertical, dentro de envelopes gaussianos bidimensionais cuja extensão espacial era medida pelo desvio padrão da gaussiana. Os estímulos foram gerados usando-se uma rotina escrita em Pascal num ambiente Delphi 7 Enterprise. Foi utilizado um microcomputador Dell Precision 390 Workstation e um gerador de estímulos CRS VSG ViSaGe para exibir os estímulos num CRT de 20”, 800 x 600 pixels, 120 Hz, padrão RGB, Mitsubishi Diamond Pro 2070SB. Nos experimentos acromáticos, os estímulos foram gerados pela modulação de luminância de uma cor branca correspondente à cromaticidade CIE1931 (x = 0,270; y = 0,280) ou CIE1976 (u’ = 0,186; v’= 0,433) e tinha luminância média de 44,5 cd/m2. Nos experimentos cromáticos, a luminância média foi mantida em 15 cd/m2 e foram usadas duas series de estímulos verde-vermelhos. Os estímulos de uma série foram formados por duas cromaticidades definidas no eixo M-L do Espaço de Cores DKL (CIE1976: verde, u’=0,131, v’=0,380; vermelho, u’=0,216, v’=0,371). Os estímulos da outra série foram formados por duas cromaticidades definidas ao longo de um eixo horizontal verde-vermelho definido no Espaço de Cores CIE1976 (verde, u’=0,150, v’=0,480; vermelho, u’=0,255, v’=0,480). Os estímulos de referência eram compostos por redes de três freqüências espaciais diferentes (0,4, 2 e 10 ciclos por grau) e envelope gaussiano com desvio padrão de 1 grau. Os estímulos de testes eram compostos por uma entre 19 freqüências espaciais diferentes em torno da freqüência espacial de referência e um entre 21 envelopes gaussianos diferentes com desvio padrão em torno de 1 grau. Na condição acromática, foram estudados quatro níveis de contraste de Michelson: 2%, 5%, 10% e 100%. Nas duas condições cromáticas foi usado o nível mais alto de contraste agregado de cones permitidos pelo gamut do monitor, 17%. O experimento consistiu numa escolha forçada de dois intervalos, cujo procedimento de testagem compreendeu a seguinte seqüência: i) apresentação de um estímulo de referência por 1 s; ii) substituição do estímulo de referência por um fundo eqüiluminante de mesma cromaticidade por 1 s; iii) apresentação do estímulo de teste também por 1 s, diferindo em relação ao estímulo de referência seja em freqüência espacial, seja em extensão espacial, com um estímulo sonoro sinalizando ao sujeito que era necessário responder se o estímulo de teste era igual ou diferente do estímulo de referência; iv) substituição do estímulo de teste pelo fundo. A extensão espacial ou a freqüência espacial do estímulo de teste foi mudada aleatoriamente de tentativa para tentativa usando o método dos estímulos constantes. Numa série de 300 tentativas, a freqüencia espacial foi variada, noutra série também de 300 tentativas, a extensão espacial foi variada, sendo que cada estímulo de teste em cada série foi apresentado pelo menos 10 vezes. A resposta do indivíduo em cada tentativa era guardada como correta ou errada para posterior construção das curvas psicométricas. Os pontos experimentais das funções psicométricas para espaço e freqüência espacial em cada nível de contraste, correspondentes aos percentuais de acertos, foram ajustados com funções gaussianas usando-se o método dos mínimos quadrados. Para cada nível de contraste, as entropias para espaço e freqüência espacial foram estimadas pelos desvios padrões dessas funções gaussianas e a entropia conjunta foi obtida multiplicando-se a raiz quadrada da entropia para espaço pela entropia para freqüência espacial. Os valores de entropia conjunta foram comparados com o mínimo teórico para sistemas lineares, 1/4π ou 0,0796. Para freqüências espaciais baixas e intermediárias, a entropia conjunta atingiu níveis abaixo do mínimo teórico em contrastes altos, sugerindo interações não lineares entre dois ou mais mecanismos visuais. Este fenômeno occorreu em todas as condições (acromática, cromática e cromática eqüiluminante) e foi mais acentuado para a frequência espacial de 0,4 ciclos / grau. Uma possível explicação para este fenômeno é a interação não linear entre as vias visuais retino-genículo-estriadas, tais como as vias K, M e P, na área visual primária ou em níveis mais altos de processamento neural.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study measured grating visual acuity in 173 children between 6-48 months of age who had different types of spastic cerebral palsy (CP). Method: Behavioural acuity was measured with the Teller Acuity Cards (TAC) using a staircase psychophysical procedure. Electrophysiological visual acuity was estimated using the sweep VEP (sVEP). Results: The percentage of children outside the superior tolerance limits was 44 of 63 (69%) and 50 of 55 (91%) of tetraplegic, 36 of 56 (64%) and 42 of 53 (79%) of diplegic, 10 of 48 (21%) and 12 of 40 (30%) of hemiplegic for sVEP and TAC, respectively. For the sVEP, the greater visual acuity deficit found in the tetraplegic group was significantly different from that of the hemiplegic group (p < 0.001). In the TAC procedure the mean visual acuity deficits of the tetraplegic and diplegic groups were significantly different from that of hemiplegic group (p < 0.001). The differences between sVEP and TAC means of visual acuity difference were statistically significant for the tetraplegic (p < 0.001), diplegic (p < 0.001), and hemiplegic group (p = 0.004). Discussion: Better visual acuities were obtained in both procedures for hemiplegic children compared to diplegic or tetraplegic. Tetraplegic and diplegic children showed greater discrepancies between the TAC and sVEP results. Inter-ocular acuity difference was more frequent in sVEP measurements. Conclusions: Electrophysiologically measured visual acuity is better than behavioural visual acuity in children with CP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Visual acuity serves as only a rough gauge of macular function. The aim therefore was to ascertain whether central an assessment of the central visual field afforded a closer insight into visual function after removal of epiretinal membranes and Infracyanine-Green- or Trypan-Blue-assisted peeling of the inner limiting membrane. Patients and methods: Fourty-three patients undergoing pars-plana vitrectomy for the removal of epimacular membranes and dye-assisted peeling of the inner limiting membrane using either Infracyanine Green (n = 29; group 1) or Trypan Blue (n = 14; group 2) were monitored prospectively for 12 months. Preoperatively, and 1, 6 and 12 months postoperatively, distance and reading visual acuities were evaluated; the central visual field was assessed by automated static perimetry. RESULTS: Twelve months after surgery, distance and reading visual acuities had improved in both groups, but to a significant degree only in Trypan-Blue-treated eyes. The difference between the two groups was not significant. Likewise at this juncture, the mean size of the visual-field defect remained unchanged in Trypan-Blue-treated eyes (preoperative: 4.3 (SD 2.1) dB; 12 months: 4.0 (2.1) dB (p = 0.15)), but had increased in Infracyanine-Green-treated ones (from 5.3 (3.7) dB to 8.0 (5.2) dB (p = 0.027)). CONCLUSION: Unlike visual acuity, the central visual field had deteriorated in Infracyanine-Green-treated eyes but not in Trypan-Blue-treated eyes 12 months after surgery. Hence, as a predictor of functional outcome, testing of the central visual field may be a more sensitive gauge than visual acuity. Furthermore, Infracyanine Green may have a chronic and potentially clinically relevant effect on the macula which is not reflected in the visual acuity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal image quality is commonly analyzed through parameters inherited from instrumental optics. These parameters are defined for ‘good optics’ so they are hard to translate into visual quality metrics. Instead of using point or artificial functions, we propose a quality index that takes into account properties of natural images. These images usually show strong local correlations that help to interpret the image. Our aim is to derive an objective index that quantifies the quality of vision by taking into account the local structure of the scene, instead of focusing on a particular aberration. As we show, this index highly correlates with visual acuity and allows inter-comparison of natural images around the retina. The usefulness of the index is proven through the analysis of real eyes before and after undergoing corneal surgery, which usually are hard to analyze with standard metrics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Refractive error is defined as the inability of the eye to bring parallel rays of light into focus on the retina, resulting in nearsightedness (myopia), farsightedness (Hyperopia) or astigmatism. Uncorrected refractive error in children is associated with increased morbidity and reduced educational opportunities. Vision screening (VS) is a method for identifying children with visual impairment or eye conditions likely to lead to visual impairment. Objective: To analyze the utility of vision screening conducted by teachers and to contribute to a better estimation of the prevalence of childhood refractive errors in Apurimac, Peru. Design: A pilot vision screening program in preschool (Group I) and elementary school children (Group II) was conducted with the participation of 26 trained teachers. Children whose visual acuity was<6/9 [20/30] (Group I) and≤6/9 (Group II) in one or both eyes, measured with the Snellen Tumbling E chart at 6 m, were referred for a comprehensive eye exam. Specificity and positive predictive value to detect refractive error were calculated against clinical examination. Program assessment with participants was conducted to evaluate outcomes and procedures. Results: A total sample of 364 children aged 3–11 were screened; 45 children were examined at Centro Oftalmológico Monseñor Enrique Pelach (COMEP) Eye Hospital. Prevalence of refractive error was 6.2% (Group I) and 6.9% (Group II); specificity of teacher vision screening was 95.8% and 93.0%, while positive predictive value was 59.1% and 47.8% for each group, respectively. Aspects highlighted to improve the program included extending training, increasing parental involvement, and helping referred children to attend the hospital. Conclusion: Prevalence of refractive error in children is significant in the region. Vision screening performed by trained teachers is a valid intervention for early detection of refractive error, including screening of preschool children. Program sustainability and improvements in education and quality of life resulting from childhood vision screening require further research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Evaluar la eficacia del tratamiento en 3 casos de exotropia intermitente (XT(i)) mediante ejercicios de terapia visual, completando la exploración clínica con Videooculografia-30 y evidenciar la potencial aplicabilidad de esta tecnología para dicho propósito. Métodos: Exponemos los cambios ocurridos tras ejercicios de terapia visual en una mujer de 36 años con XT(i) de -25 dioptrías prismáticas (dp) de lejos y 18 dp de cerca; Un niño de 10 años de edad con 8 dp de XT(i) en posición primaria, asociados a +6 dp de hipotropia izquierda; y un hombre de 63 años con XT(i) de 6 dp en posición primaria asociada a +7 dp de hipertropia derecha. Todos los pacientes presentaron buena agudeza visual corregida en ambos ojos. La inestabilidad de la desviación ocular se evidenció mediante análisis de VOG-30, revelando la presencia de components verticales y torsionales. Se realizaron ejercicios de terapia visual, incluyendo diferentes tipos de ejercicios de vergencias, acomodación y percepción de la diplopía. Resultados: Tras la terapia visual se obtuvieron excelentes rangos de vergencias fusionales y de punto próximo de convergencia («hasta la nariz»). El examen mediante VOG-3D (Sensoro Motoric lnstruments, Teltow, Germany) confirmó la compensación de la desviación con estabilidad del alineamiento ocular. Se observó una significativa mejora después de la terapia en los components verticals y torsionales, lo cuales se hicieron más estables. Los pacientes se mostraron muy satisfechos de los resultados obtenidos. Conclusión: La VOG-3D es una técnica útil para dotamos de un método objetivo de registro de la compensación y estabilidad de la desviación ocular después de realizar ejercicios de terapia visual en casos de XT(i), ofreciéndonos un detallado análisis de la mejoría de los components verticales y torsionales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a review of studies that have investigated the proposed rehabilitative benefit of tinted lenses and filters for people with low vision. Currently, eye care practitioners have to rely on marketing literature and anecdotal reports from users when making recommendations for tinted lens or filter use in low vision. Our main aim was to locate a prescribing protocol that was scientifically based and could assist low vision specialists with tinted lens prescribing decisions. We also wanted to determine if previous work had found any tinted lens/task or tinted lens/ocular condition relationships, i.e. were certain tints or filters of use for specific tasks or for specific eye conditions. Another aim was to provide a review of previous research in order to stimulate new work using modern experimental designs. Past studies of tinted lenses and low vision have assessed effects on visual acuity (VA), grating acuity, contrast sensitivity (CS), visual field, adaptation time, glare, photophobia and TV viewing. Objective and subjective outcome measures have been used. However, very little objective evidence has been provided to support anecdotal reports of improvements in visual performance. Many studies are flawed in that they lack controls for investigator bias, and placebo, learning and fatigue effects. Therefore, the use of tinted lenses in low vision remains controversial and eye care practitioners will have to continue to rely on anecdotal evidence to assist them in their prescribing decisions. Suggestions for future research, avoiding some of these experimental shortcomings, are made. © 2002 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS. Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS. Four months after implantation best-corrected acuity was -0.01 ± 0.16 logMAR at distance and 0.60 ± 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 ± 0.38 D. The average dynamic amplitude of accommodation was 0.71 ± 0.47 D, with a lag behind the target of 0.50 ± 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 ± 0.28 D/mm). Subjective amplitude of accommodation was 2.24 ± 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS. The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL. Copyright © Association for Research in Vision and Ophthalmology.