911 resultados para Non-invasive monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work presented here is part of a larger study to identify novel technologies and biomarkers for early Alzheimer disease (AD) detection and it focuses on evaluating the suitability of a new approach for early AD diagnosis by non-invasive methods. The purpose is to examine in a pilot study the potential of applying intelligent algorithms to speech features obtained from suspected patients in order to contribute to the improvement of diagnosis of AD and its degree of severity. In this sense, Artificial Neural Networks (ANN) have been used for the automatic classification of the two classes (AD and control subjects). Two human issues have been analyzed for feature selection: Spontaneous Speech and Emotional Response. Not only linear features but also non-linear ones, such as Fractal Dimension, have been explored. The approach is non invasive, low cost and without any side effects. Obtained experimental results were very satisfactory and promising for early diagnosis and classification of AD patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because the excreted sporocysts and/or oocysts of various species of Sarcocystis may not be discriminated morphologically, we sought to validate a diagnostic technique based on variation in the 18S rDNA sequence. Oocysts and/or sporocysts; from three taxa

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structured Light Plethysmography (SLP) is a novel non-invasive method that uses structured light to perform pulmonary function testing that does not require physical contact with a patient. The technique produces an estimate of chest wall volume changes over time. A patient is observed continuously by two cameras and a known pattern of light (i.e. structured light) is projected onto the chest using an off-the-shelf projector. Corner features from the projected light pattern are extracted, tracked and brought into correspondence for both camera views over successive frames. A novel self calibration algorithm recovers the intrinsic and extrinsic camera parameters from these point correspondences. This information is used to reconstruct a surface approximation of the chest wall and several novel ideas for 'cleaning up' the reconstruction are used. The resulting volume and derived statistics (e.g. FVC, FEV) agree very well with data taken with a spirometer. © 2010. The copyright of this document resides with its authors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article examines some preliminary tests which were performed in order to evaluate the best electrode configuration (width and spacing) for cell culture analyses. Biochips packaged with indium tin oxide (ITO) interdigitated electrodes (IDEs) were used to perform impedance measurements on A549 cells cultured on the surface of the biochip. Several tests were carried out using a 10 mM solution of Sodium Chloride (NaCl), cell medium and the cell culture itself to characterize some of the configurations already fabricated in the facilities at Tyndall National Institute.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The early detection of developmental disorders is key to child outcome, allowing interventions to be initiated that promote development and improve prognosis. Research on autism spectrum disorder (ASD) suggests behavioral markers can be observed late in the first year of life. Many of these studies involved extensive frame-by-frame video observation and analysis of a child's natural behavior. Although non-intrusive, these methods are extremely time-intensive and require a high level of observer training; thus, they are impractical for clinical and large population research purposes. Diagnostic measures for ASD are available for infants but are only accurate when used by specialists experienced in early diagnosis. This work is a first milestone in a long-term multidisciplinary project that aims at helping clinicians and general practitioners accomplish this early detection/measurement task automatically. We focus on providing computer vision tools to measure and identify ASD behavioral markers based on components of the Autism Observation Scale for Infants (AOSI). In particular, we develop algorithms to measure three critical AOSI activities that assess visual attention. We augment these AOSI activities with an additional test that analyzes asymmetrical patterns in unsupported gait. The first set of algorithms involves assessing head motion by tracking facial features, while the gait analysis relies on joint foreground segmentation and 2D body pose estimation in video. We show results that provide insightful knowledge to augment the clinician's behavioral observations obtained from real in-clinic assessments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of pain in neonates is difficult due to their limited means of communication. The aim was to determine whether behavioural reactions of cry and facial activity provoked by an invasive procedure could be discriminated from responses to non-invasive tactile events. Thirty-six healthy full-term infants (mean age 2.2 h) received 3 procedures in counterbalanced order: intramuscular injection, application of triple dye to the umbilical stub, and rubbing thigh with alcohol. Significant effects of procedure were found for total face activity and latency to face movement. A cluster of facial actions comprised of brow bulging, eyes squeezed shut, deepening of the naso-labial furrow and open mouth was associated most frequently with the invasive procedure. Comparisons between the 2 non-invasive procedures showed more facial activity to thigh swabbing and least to application of triple dye to the umbilical cord. Acoustic analysis of cry showed statistically significant differences across procedures only for latency to cry and cry duration for the group as a whole. However, babies who cried to two procedures showed higher pitch and greater intensity to the injection. There were no significant differences in melody, dysphonation, or jitter. Methodological difficulties for investigators in this area were examined, including criteria for the selection of cries for analysis, and the logical and statistical challenges of contrasting cries induced by different conditions when some babies do not always cry. It was concluded that facial expression, in combination with short latency to onset of cry and long duration of first cry cycle typifies reaction to acute invasive procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive population genetics has become a valuable tool in ecology and conservation biology, allowing genetic studies of wild populations without the need to catch, handle or even observe the study subjects directly. We address some of the concerns regarding the limitations of using non-invasive samples by comparing the quality of population genetic information gained through DNA extracted from faecal samples and biopsy samples of two elusive bat species, Myotis mystacinus and Myotis nattereri. We demonstrate that DNA extracted from faeces and tissue samples gives comparable results for frequency based population genetic analyses, despite the occurrence of genotyping errors when using faecal DNA. We conclude that non-invasive genetic sampling for population genetic analysis in bats is viable, and although more labour-intensive and expensive, it is an alternative to tissue sampling, which is particularly pertinent when specimens are rare, endangered or difficult to capture. © 2012 Museum and Institute of Zoology PAS.