976 resultados para Needle Biopsy
Resumo:
OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.
Resumo:
Testicular biopsy has been a complementary technique for clinical and research purposes to evaluate reproductive function in males. However, hemorrhage, inflammation, degeneration, and adhesion are factors that might limit the use of this procedure. In order to minimize these potential problems, fibrin glue derived from snake venom, a tissue adhesive with sealing, hemostatic, and healing properties, was used in conjunction with bilateral testicular biopsy with the Tru-Cut needle and was compared with a more conventional technique that uses nylon suture. Thirty mature rams were randomly assigned to three groups of 10 animals each, as follows: nonsurgical control group (no scrotal surgery, or biopsy); biopsy + glue group (fibrin glue on puncture sites and skin incisions) and biopsy + suture group (compression with swab on puncture sites and suturing of skin incision). The surgeries of the rams in the biopsy groups were performed on the same day, which was designated Day 0 for all three groups. Data of scrotal circumference, number of spermatozoa per ejaculum, percentage of morphologically abnormal spermatozoa, spermatozoa motility, and serum testosterone concentrations from Days -7, 20, 40, 60, 80 and 100 were evaluated. There were no significant differences between groups within days for any of the parameters evaluated. In conclusion, the testicular biopsy procedure using the Tru-Cut needle in conjunction with conventional nylon suture or the more novel fibrin glue in rams did not affect any of the parameters of testicular function evaluated in this study and was shown to be relatively simple, safe and efficient. (C) 2002 Published by Elsevier B.V. B.V.
Resumo:
The Sister Mary Joseph (SMJ) nodule is a clinical sign of metastatic cancer involving the umbilicus. The vast majority of these instances represent adenocarcinomas arising from ovarian or colorectal primaries. We present a patient who presented with ascites and the SMJ lesion that turned out to be a metastatic gastrointestinal stromal tumor after fine needle aspiration biopsy was performed. The lesion was subsequently histologically confirmed. Gastrointestinal stroma tumor involving the umbilicus is exceedingly uncommon and only rarely presents in this fashion. The cytomorphological features, differential diagnosis, and comparison with the tissue specimen are made. © 2006 Elsevier Inc. All rights reserved.
Mammary benign neoplasm diagnosed by fine needle aspiration biopsy in a guinea pig (Cavia porcellus)
Resumo:
Cytology is a well established research technique in human and veterinary medicine, but it is rarely used in small rodents. Spontaneous tumors are relatively uncommon in guinea pigs and those described in literature include a variety of organs like skin and subcutis, respiratory and reproductive tract, endocrine and hematopoietic system, and mammary gland. The objective of this article was to describe the use of the fine needle aspiration biopsy technique (FNAB) on evaluation of a mammary neoplasm in a guinea pig and describe the main cytological findings for the first time in literature.
Resumo:
Facial cosmetic procedures are increasingly requested, and dermal filler materials have been widely used as a nonsurgical option since the 1980s. However, injectable fillers have been implicated in local adverse reactions. Therefore, the aim of this article was to describe the use of fine needle aspiration cytology (FNAC) in the diagnosis of foreign-body reactions to the perioral injection of dermal fillers. A 69-year-old woman presented with a painful nodule on her right nasolabial fold. Intraoral FNAC was performed, and cytologic smears were examined under optical and polarized light microscopy, showing birefringent microspheres, confirming the diagnosis of an adverse reaction caused by polymethyl methacrylate filler. FNAC is a less invasive method to confirm the diagnosis of adverse reactions caused by perioral cosmetic dermal fillers.
Resumo:
Major requirements for performance of liver biopsy (LB) are the benefits for the patient and the impossibility of having the same information by less invasive procedures. In the last two decades physicians have faced the difficult task of convincing a patient positive for hepatitis C, with minimal clinical or laboratory alterations to be submitted to LB in order to evaluate the status of the disease for therapeutic management. The characteristics of the needle used for percutaneous LB interferes with the accuracy of diagnosis. In chronic hepatitis C (CHC), validity is achieved with liver fragments about 25mm in length containing more than 10 portal tracts. Morbidity due to LB is mainly related to bleeding but death is very rare. Severe complications are also uncommon, increasing with number of passes and decreasing with experience of operator and ultrasound guidance. Although CHC is a diffuse disease, the various areas of the liver may not be equally affected and sampling errors are possible. Another potential limitation of LB is the discordance between pathologists in its interpretation. To replace LB, many panels of surrogate markers have been described, aiming to identify extent of fibrosis and inflammation. All of them have used LB as their ""gold standard"". Liver biopsy continues to be the most reliable method to evaluate the possibility of therapy for CHC. Universal treatment of all patients with diagnosis of CHC would be ideal. But, there are mainly three drawbacks. Overall efficacy is as low as 50%, side effects are common and may be severe and treatment is prolonged and expensive. The acceptability of the biopsy by the patient is highly dependent on the physician`s conviction of its usefulness.
Resumo:
Introduction: The samples obtained from fine needle aspiration in liquid base cytology (FNAC) are often limited by scarce cellularity compared to the amount of colloid and presence of blood. Accordingly, it was important to test alternative technical procedures so as to maximize the cellularity of each sample. Objective: To compare the morphological features and cellularity of the three procedures in the FNAC cytodiagnosis of the thyroid. Methods: A total of 31 cases were each subjected to a cell block and ThinPrep preparation as well as a routine smear. The observation and analysis was performed using an optical microscope. Cytological diagnosis of each cell block case was objectively analysed for cellularity, presence of background and cellular preservation. Each smear and ThinPrep case was analysed for the presence or absence of cells. The data was analysed with Microsoft Excel (Office 2010) and SPSS (Statistical Package of Social Science) version 15.0 for Windows. Results: Of 31 cases, only 20 had thyroid cells in the cell block and ThinPrep preparations, however, all smear cases contained thyroid cells. Some background was found in 30 Cell block cases with only 5 of these containing well preserved cells for cytodiagnosis. Conclusions: As indicated by the results, smear is the most appropriate procedure for FNAC of the thyroid.
Resumo:
Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO2) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO2 was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.
Resumo:
Le diagnostic final des pathologies impliquant le système hématopoïétique tel que les leucémies, pancytopénies inexpliquées ou autres désordres médullaires, requiert une ponction biopsie de moelle. Cette procédure relativement invasive doit être maîtrisée non seulement par l'hématologue, mais également par l'interniste. Il est crucial d'en connaître les indications et contre-indications et de pouvoir prévenir les complications par une bonne connaissance de celles-ci. Cet article revoit ces différents éléments et apporte les détails pratiques de la procédure ainsi que le matériel nécessaire. The definitive diagnosis of several hematological diseases, as for instance leukaemias, unexplained pancytopenias and other bone marrow disorders, requires a bone marrow aspiration and biopsy. Not only haematologists, but also internists, need to master this rather invasive procedure. The knowledge of indications, contra-indications, potential complications and their prevention of its complications is of utmost importance. This article reviews these topics about bone marrow biopsy, giving some practical advices on this procedure
Resumo:
The purpose was to evaluate the influence of radiologist's experience on the diagnostic yield and complications of a percutaneous liver biopsy (PLB) method. Six hundred patients underwent an ultrasound-guided PLB by an inexperienced operator in 25.2% of cases (experience of less than 15 percutaneous liver biopsies performed alone--group I) or by an experienced operator (experience of more than 150 percutaneous liver biopsies--group II). The two groups were well-matched with respect to sex, age, percentage with viral hepatitis without histological cirrhosis, number of needle passes, history of liver biopsy and pain before the biopsy. A histological diagnosis was available in 97.3% of cases without any significant difference between the two groups ( P=0.25). However, group II samples were significantly longer and contained more portal tracts ( P=0.01). Pain was mild immediately and 6 h after the biopsy, without significant difference between both groups. Eight vasovagal reactions (five in group II) and one arteriobiliary fistula (in group II) occurred. With the method of PLB used for this study, operator's experience did not influence either the final histological diagnosis or the degree of pain suffered.
Resumo:
OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.