873 resultados para National Measurement System for Time and Frequency.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To assess the impact of a closed-loop electronic prescribing and automated dispensing system on the time spent providing a ward pharmacy service and the activities carried out. Setting Surgical ward, London teaching hospital. Method All data were collected two months pre- and one year post-intervention. First, the ward pharmacist recorded the time taken each day for four weeks. Second, an observational study was conducted over 10 weekdays, using two-dimensional work sampling, to identify the ward pharmacist's activities. Finally, medication orders were examined to identify pharmacists' endorsements that should have been, and were actually, made. Key findings Mean time to provide a weekday ward pharmacy service increased from 1 h 8 min to 1 h 38 min per day (P = 0.001; unpaired t-test). There were significant increases in time spent prescription monitoring, recommending changes in therapy/monitoring, giving advice or information, and non-productive time. There were decreases for supply, looking for charts and checking patients' own drugs. There was an increase in the amount of time spent with medical and pharmacy staff, and with 'self'. Seventy-eight per cent of patients' medication records could be assessed for endorsements pre- and 100% post-intervention. Endorsements were required for 390 (50%) of 787 medication orders pre-intervention and 190 (21%) of 897 afterwards (P < 0.0001; chi-square test). Endorsements were made for 214 (55%) of endorsement opportunities pre-intervention and 57 (30%) afterwards (P < 0.0001; chi-square test). Conclusion The intervention increased the overall time required to provide a ward pharmacy service and changed the types of activity undertaken. Contact time with medical and pharmacy staff increased. There was no significant change in time spent with patients. Fewer pharmacy endorsements were required post-intervention, but a lower percentage were actually made. The findings have important implications for the design, introduction and use of similar systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reaction between gas-phase ozone and monolayers of the unsaturated lipid 1-palmitoy1-2-oleoyl-sn-glycero-3-phosphocholine, POPC, on aqueous solutions has been studied in real time using neutron reflection and surface pressure measurements. The reaction between ozone and lung surfactant, which contains POPC, leads to decreased pulmonary function, but little is known shout the changes that occur to the interfacial material as a result of oxidation. The results reveal that the initial reaction of ozone with POPC leads to a rapid increase in surface pressure followed by a slow decrease to very low values. The neutron reflection measurements, performed on an isotopologue of POPC with a selectively deuterated palmitoyl strand, reveal that the reaction leads to loss of this strand from the air-water interface. suggesting either solubilization of the product lipid or degradation of the palmitoyl strand by a reactive species. Reactions of H-1-POPC on D2O reveal that the headgroup region of the lipids in aqueous solution is not dramatically perturbed by the reaction of POPC monolayers with ozone supporting degradation of the palmitoyl strand rather than solubilization. The results are consistent with the reaction of ozone with the oleoyl strand of POPC at the air water interface leading to the formation of OH radicals. the highly reactive OH radicals produced can then go on to react with the saturated palmitoyl strands leading to the formation or oxidized lipids with shorter alkyl tails.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sexual system of the symbiotic shrimp Thor amboinensis is described, along with observations on sex ratio and host-use pattern of different populations. We used a comprehensive approach to elucidate the previously unknown sexual system of this shrimp. Dissections, scanning electron microscopy, size-frequency distribution analysis, and laboratory observations demonstrated that T amboinensis is a protandric hermaphrodite: shrimp first mature as males and change into females later in life. Thor amboinensis inhabited the large and structurally heterogeneous sea anemone Stichoclactyla helianthus in large groups (up to 11 individuals) more frequently than expected by chance alone. Groups exhibited no particularly complex social structure and showed male-biased sex ratios more frequently than expected by chance alone. The adult sex ratio was male-biased in the four separate populations studied, one of them being thousands of kilometers apart from the others. This study supports predictions central to theories of resource monopolization and sex allocation. Dissections demonstrated that unusually large males were parasitized by an undescribed species of isopod (family Entoniscidae). Infestation rates were similarly low in both sexes (approximate to 11%-12%). The available information suggests that T. amboinensis uses pure search promiscuity as a mating system. This hypothesis needs to be formally tested with mating behavior observations and field measurements on the movement pattern of both sexes of the species. Further detailed studies on the lifestyle and sexual system of all the species within this genus and the development of a molecular phylogeny are necessary to elucidate the evolutionary history of gender expression in the genus Thor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the results of an intracavity Stark spectroscopy experiment on the fundamental state of (CD3OH)-C-13. We use an optically pumped hybrid waveguide FIR laser, CH2F2 as active molecule, and (CD3OH)-C-13 as absorbent molecule. No Brewster window is needed to separate the lasing gas from the absorbing deuterated methanol. An absorption line is assigned as E(l) symmetry (n, K, J): (1,4,18) --> (1,5,18) and its frequency is measured as 63.08631 cm(-1) with a precision of a few parts in 10(7); two more absorptions are reported and a tentative assignment for one of them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims to demonstrate an application of telemetry for monitoring process variables. The authors developed the prototype of a dedicated device capable of multiplexing, encoding and transmitting real-time data signals via amplitude-shift keying modulation to remotely located device(s). The prototype development is described in details, enabling the reproduction of the proposed telemetry system for a three-phase motor as well as for other devices. Furthermore, the proposed device has an easy implementation by using of accessible components and low cost, also presenting a tutorial and educational purpose. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little information is available related to adolescent calcium intake and relationships with injuries they might suffer from sport participation. To determine calcium intake of high school athletes, to assess their self reported injury rates, and to examine the relationship between the two over a 12 month period of time. Participants received a questionnaire at their school and completed it anywhere they found convenient. Adolescent athletes in the Lincoln Public School system (n=43) that participated in at least one sport in the past year. Four age groups participated in the study with sixteen year olds having a significantly higher calcium intake at 1297 mg that of fourteen year olds. A variety of sports were represented with largest number of respondents participating in baseball/or softball at (55%). The next most played sport was basketball at (18%). Median total diet calcium was 1144.5 mg with a mean of 1182 mg + 567 mg. For the frequency of injuries that caused a missed practice or game in the past year, ankle injuries were the most common (25%). Knee injuries were the second most common (17%), followed closely by hand injuries (8%). Mean total diet calcium of athletes with five or more injuries that caused a missed practice or game was significantly higher at 1966 mg (P<.05) than athletes mean diet calcium with zero, one, two, and three injuries. Total milk calcium of those who reported three injuries that resulted in broken or fractured bones or dislocated joints was significantly higher (P<.05) at 1286 mg of total milk calcium than those who reported having zero, one, or two breaks or fractures. Athletes with higher calcium intakes have a higher number of reported injuries. This may be the result of increased vigorous activity which leads to increased calorie and calcium consumption. More importantly, this increased activity leads to an increased chance of injury. The greater calcium intake correlated with greater number of injuries may also be because of third parties advising the athletes who get injured to drink more milk and get more calcium in their diets because they have been injuries already.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alternans of cardiac action potential duration (APD) is a well-known arrhythmogenic mechanism which results from dynamical instabilities. The propensity to alternans is classically investigated by examining APD restitution and by deriving APD restitution slopes as predictive markers. However, experiments have shown that such markers are not always accurate for the prediction of alternans. Using a mathematical ventricular cell model known to exhibit unstable dynamics of both membrane potential and Ca2+ cycling, we demonstrate that an accurate marker can be obtained by pacing at cycle lengths (CLs) varying randomly around a basic CL (BCL) and by evaluating the transfer function between the time series of CLs and APDs using an autoregressive-moving-average (ARMA) model. The first pole of this transfer function corresponds to the eigenvalue (λalt) of the dominant eigenmode of the cardiac system, which predicts that alternans occurs when λalt≤−1. For different BCLs, control values of λalt were obtained using eigenmode analysis and compared to the first pole of the transfer function estimated using ARMA model fitting in simulations of random pacing protocols. In all versions of the cell model, this pole provided an accurate estimation of λalt. Furthermore, during slow ramp decreases of BCL or simulated drug application, this approach predicted the onset of alternans by extrapolating the time course of the estimated λalt. In conclusion, stochastic pacing and ARMA model identification represents a novel approach to predict alternans without making any assumptions about its ionic mechanisms. It should therefore be applicable experimentally for any type of myocardial cell.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early descriptions for species of Aka were poor in detail, and the only spicule type that occurs in this genus does not vary much between species, which led to taxonomic confusion. Moreover, the type specimens of 5 species of Aka are lost, causing considerable problems. Mediterranean specimens of Aka were identified as Aka labyrinthica (Hancock, 1849) by Topsent (1900), even though this species was originally described from the Indo-Pacific. All following publications on Mediterranean Aka accepted Topsent's decision. We assessed this problem with new samples from the Ionian Sea. Our material consisted of only one specimen of Aka, and we had to rely mainly on spicule characters for comparison to other species. We developed a system for species recognition solely based on spicular characters and biometry, involving a combination of the parameters oxea length, width, tip form and angle of curvature. This approach was surprisingly accurate. Forming ratios of the above parameters was less helpful, but can sometimes provide additional information. We identified our sample as Aka infesta (Johnson, 1899), and describe it as a minute-fistulate species with large, multicamerate erosion traces and stout, smooth oxeas. Our data further imply that A. labyrinthica sensu Hancock has not yet been found in the Mediterranean. A. labyrinthica sensu Topsent is a collection of different species not including A. labyrinthica sensu Hancock.