893 resultados para Musculoskeletal ultrasound
Resumo:
Purpose: To establish whether there was a difference in health-related quality of life (HRQoL) in people with chronic musculoskeletal disorders (PwCMSKD) after participating in a multimodal physiotherapy program (MPP) either two or three sessions a week. Methods: Total of 114 PwCMSKD participated in this prospective randomised controlled trial. An individualised MPP, consisting of exercises for mobility, motor-control, muscle strengthening, cardiovascular training, and health education, was implemented either twice a week (G2: n = 58) or three times a week) (G3: n = 56) for 1 year. Outcomes: HRQoL physical and mental health state (PHS/MHS), Roland Morris disability Questionnaire (RMQ), Neck-Disability-Index (NDI) and Western Ontario and McMaster Universities’ Arthritis Index (WOMAC) were used to measure outcomes of MPP for people with chronic low back pain, chronic neck pain and osteoarthritis, respectively. Measures were taken at baseline, 8 weeks (8 w), 6 months (6 m), and 1 year (1 y) after starting the programme. Results: No statistically significant differences were found between the two groups (G2 and G3), except in NDI at 8 w (−3.34, (CI 95%: −6.94/0.84, p = 0.025 (scale 0–50)). All variables showed improvement reaching the following values (from baseline to 1 y) G2: PHS: 57.72 (baseline: 41.17; (improvement: 16.55%), MHS: 74.51 (baseline: 47.46, 27.05%), HRQoL 0.90 (baseline: 0.72, 18%)), HRQoL-VAS 84.29 (baseline: 58.04, 26.25%), RMQ 4.15 (baseline: 7.85, 15.42%), NDI 3.96 (baseline: 21.87, 35.82%), WOMAC 7.17 (baseline: 25.51, 19.10%). G3: PHS: 58.64 (baseline: 39.75, 18.89%), MHS: 75.50 (baseline: 45.45, (30.05%), HRQoL 0.67 (baseline: 0.88, 21%), HRQoL-VAS 86.91 (baseline: 52.64, 34.27%), RMQ 4.83 (baseline: 8.93, 17.08%), NDI 4.91 (baseline: 23.82, 37.82%), WOMAC 6.35 (baseline: 15.30, 9.32%). Conclusions: No significant differences between the two groups were found in the outcomes of a MPP except in the NDI at 8 weeks, but both groups improved in all variables during the course of 1 year under study.
Resumo:
The aim of this study was to develop a new method for quantifying intersegmental motion of the spine in an instrumented motion segment L4–L5 model using ultrasound image post-processing combined with an electromagnetic device. A prospective test–retest design was employed, combined with an evaluation of stability and within- and between-day intra-tester reliability during forward bending by 15 healthy male patients. The accuracy of the measurement system using the model was calculated to be ± 0.9° (standard deviation = 0.43) over a 40° range and ± 0.4 cm (standard deviation = 0.28) over 1.5 cm. The mean composite range of forward bending was 15.5 ± 2.04° during a single trial (standard error of the mean = 0.54, coefficient of variation = 4.18). Reliability (intra-class correlation coefficient = 2.1) was found to be excellent for both within-day measures (0.995–0.999) and between-day measures (0.996–0.999). Further work is necessary to explore the use of this approach in the evaluation of biomechanics, clinical assessments and interventions.
Resumo:
Objective To analyze the ability to discriminate between healthy individuals and individuals with chronic nonspecific low back pain (CNLBP) by measuring the relation between patient-reported outcomes and objective clinical outcome measures of the erector spinae (ES) muscles using an ultrasound during maximal isometric lumbar extension. Design Cross-sectional study with screening and diagnostic tests with no blinded comparison. Setting University laboratory. Participants Healthy individuals (n=33) and individuals with CNLBP (n=33). Interventions Each subject performed an isometric lumbar extension. With the variables measured, a discriminate analysis was performed using a value ≥6 in the Roland and Morris disability questionnaire (RMDQ) as the grouping variable. Then, a logistic regression with the functional and architectural variables was performed. A new index was obtained from each subject value input in the discriminate multivariate analysis. Main Outcome Measures Morphologic muscle variables of the ES muscle were measured through ultrasound images. The reliability of the measures was calculated through intraclass correlation coefficients (ICCs). The relation between patient-reported outcomes and objective clinical outcome measures was analyzed using a discriminate function from standardized values of the variables and an analysis of the reliability of the ultrasound measurement. Results The reliability tests show an ICC value >.95 for morphologic and functional variables. The independent variables included in the analysis explained 42% (P=.003) of the dependent variable variance. Conclusions The relation between objective variables (electromyography, thickness, pennation angle) and a subjective variable (RMDQ ≥6) and the capacity of this relation to identify CNLBP within a group of healthy subjects is moderate. These results should be considered by clinicians when treating this type of patient in clinical practice.
Resumo:
Piezoelectric ultrasound transducers are commonly used to convert mechanical energy to electrical energy and vice versa. The transducer performance is highly affected by the frequency at which it is excited. If excitation frequency and main resonant frequency match, transducers can deliver maximum power. However, the problem is that main resonant frequency changes in real time operation resulting in low power conversion. To achieve the maximum possible power conversion, the transducer should be excited at its resonant frequency estimated in real time. This paper proposes a method to first estimate the resonant frequency of the transducer and then tunes the excitation frequency accordingly in real time. The measurement showed a significant difference between the offline and real time resonant frequencies. Also, it was shown that the maximum power was achieved at the resonant frequency estimated in real time compare to the one measured offline.
Resumo:
From 2008-09 to 2012-13, the most prevalent worker compensation claim in the Queensland Ambulance Service (QAS) was musculoskeletal injuries at >80%. This is consistent with literature that shows Musculoskeletal Disorders (MSD) was one of the front runners for workplace injuries among many professions. In an attempt to reduce the injury rate and related claims, the QAS created a selection criterion for their workers based on the Health Related Fitness Test. This method intended to select workers based upon their fitness level, instead of selecting for their ability to perform the tasks or modify the tasks to better suit the workers. With injury rates remaining high, further research produced the Patient Handling Equipment Project Report, which provided the background for the Manual Handling Program Book. The Manual Handling Program Book however lacks in accurately addressing musculoskeletal hazards; actions which cause or avoid injury, correct posture and motion for patient movement, muscular biomechanics, static and dynamic workload including activities causing strain, and equipment use in relation to musculoskeletal hazards. The exploratory research aims to better understand the ambulance service’s perception of Manual Materials Handling (MMH), how it relates to musculoskeletal injuries and how the service has attempted to reduce its prevalence. Based on a literature review and a critical analysis of the QAS Health Related Fitness Test, QAS Patient Handling Equipment Project Report and the QAS Manual Handling Program Book, an understanding of their shortfalls in the prevention of musculoskeletal injuries was gained. This entails understanding the work tasks, workloads, strains and workflow of paramedics. This research creates a starting point for further research into musculoskeletal injuries in paramedics. This study specifically looks at hazards related to musculoskeletal disorders. It identifies work system deficiencies that contribute to the prevalence of musculoskeletal injuries, and possible interventions to avoid them in paramedics.
Resumo:
Background Nurses are at high risk of musculoskeletal disorders (MSDs). Although the prevalence of MSDs of the lower back, upper limbs, neck and shoulders have been reported previously in nursing, few studies have evaluated MSDs of the foot and ankle. This study evaluated the prevalence of foot and ankle MSDs in nurses and their relation to individual and workplace risk factors. Methods A self-administered survey incorporating the Nordic Musculoskeletal Questionnaire (NMQ) was distributed, over a nine-week period, to all eligible nurses (n = 416) working in a paediatric hospital in Brisbane, Australia. The prevalence of MSDs for each of the NMQ body regions was determined. Bivariate and multivariable logistic regression analyses were conducted to examine the relationships between activity-limiting foot/ankle MSDs and risk factors related to the individual (age, body mass index, number of existing foot conditions, smoking history, general physical health [SF36 Physical Component Scale], footwear features) or the workplace (level of nursing position, work location, average hours worked, hours worked in previous week, time since last break from work). Results A 73% response rate was achieved with 304 nurses completing surveys, of whom 276 were females (91%). Mean age of the nurses was 37 years (±10), younger than the state average of 43 years. Foot/ankle MSDs were the most prevalent conditions experienced by nurses during the preceding seven days (43.8%, 95% CI 38.2-49.4%), the second most prevalent MSDs to impair physical activity (16.7%, 95% CI 13.0-21.3%), and the third most prevalent MSD, after lower-back and neck problems, during the preceding 12 months (55.3%, 95% CI 49.6-60.7%). Of the nurse and work characteristics investigated, obesity, poor general physical health, existing foot conditions and working in the intensive care unit emerged as statistically significant (p < 0.05) independent risk factors for activity-limiting foot/ankle MSDs. Conclusions Foot/ankle MSDs are common in paediatric hospital nurses and resulted in physical activity limitations in one out of every six nurses. We recommend targeted education programs regarding the prevention, self-management and treatment strategies for foot/ankle MSDs. Further research is needed into the impact of work location and extended shift durations on foot/ankle MSDs.
Resumo:
Background Spanish is one of the five most spoken languages in the world. There is currently no published Spanish version of the Örebro Musculoskeletal Pain Questionnaire (OMPQ). The aim of the present study is to describe the process of translating the OMPQ into Spanish and to perform an analysis of reliability, internal structure, internal consistency and concurrent criterion-related validity. Methods Design: Translation and psychometric testing. Procedure: Two independent translators translated the OMPQ into Spanish. From both translations a consensus version was achieved. A backward translation was made to verify and resolve any semantic or conceptual problems. A total of 104 patients (67 men/37 women) with a mean age of 53.48 (±11.63), suffering from chronic musculoskeletal disorders, twice completed a Spanish version of the OMPQ. Statistical analysis was performed to evaluate the reliability, the internal structure, internal consistency and concurrent criterion-related validity with reference to the gold standard questionnaire SF-12v2. Results All variables except “Coping” showed a rate above 0.85 on reliability. The internal structure calculation through exploratory factor analysis indicated that 75.2% of the variance can be explained with six components with an eigenvalue higher than 1 and 52.1% with only three components higher than 10% of variance explained. In the concurrent criterion-related validity, several significant correlations were seen close to 0.6, exceeding that value in the correlation between general health and total value of the OMPQ. Conclusions The Spanish version of the screening questionnaire OMPQ can be used to identify Spanish patients with musculoskeletal pain at risk of developing a chronic disability.
Resumo:
Ultrasound has been previously investigated as an alternative readout method for irradiated polymer gel dosimeters, with authors reporting varying dose responses. We extend previous work utilizing a new computed tomography ultrasound scanner comprising of two identical 5 MHz, 128-element linear-array ultrasound transducers, co-axially aligned and submerged in water as a coupling agent, with rotational of the gel dosimeter between the transducers facilitated by a robotic arm. We have investigated the dose-dependence of both ultrasound bulk attenuation and broadband ultrasound attenuation (BUA) for the PAGAT gel dosimeter. The ultrasound bulk attenuation dose sensitivity was found to be 1.46 ± 0.04 dB m −1 Gy −1, being in agreement with previously published results for PAG and MAGIC gels. BUA was also found to be dose dependent and was measured to be 0.024 ± 0.003 dB MHz −1 Gy −1; the advantage of BUA being its insensitivity to frequency-independent attenuation mechanisms including reflection and refraction, thereby minimizing image reconstruction artefacts.
Resumo:
Bone and joint diseases are major causes of morbidity and mortality worldwide, and their prevalence is increasing as the average population age increases. Most common musculoskeletal diseases show significant heritability, and few have treatments that prevent disease or can induce true treatment-free, disease-free remission. Furthermore, despite valiant efforts of hypothesis-driven research, our understanding of the etiopathogenesis of these conditions is, with few exceptions, at best moderate. Therefore, there has been a long-standing interest in genetics research in musculoskeletal disease as a hypothesis-free method for investigating disease etiopathogenesis. Important contributions have been made through the identification of monogenic causes of disease, but the holy grail of human genetics research has been the identification of the genes responsible for common diseases. The development of genome-wide association (GWA) studies has revolutionized this field, and led to an explosion in the number of genes identified that are definitely involved in musculoskeletal disease pathogenesis. However, this approach will not identify all common disease genes, and although the current progress is exciting and proves the potential of this research discipline, other approaches will be required to identify many of the types of genetic variation likely to be involved.
Resumo:
Considering ultrasound propagation through complex composite media as an array of parallel sonic rays, a comparison of computer simulated prediction with experimental data has previously been reported for transmission mode (where one transducer serves as transmitter, the other as receiver) in a series of ten acrylic step-wedge samples, immersed in water, exhibiting varying degrees of transit time inhomogeneity. In this study, the same samples were used but in pulse-echo mode, where the same ultrasound transducer served as both transmitter and receiver, detecting both ‘primary’ (internal sample interface) and ‘secondary’ (external sample interface) echoes. A transit time spectrum (TTS) was derived, describing the proportion of sonic rays with a particular transit time. A computer simulation was performed to predict the transit time and amplitude of various echoes created, and compared with experimental data. Applying an amplitude-tolerance analysis, 91.7±3.7% of the simulated data was within ±1 standard deviation (STD) of the experimentally measured amplitude-time data. Correlation of predicted and experimental transit time spectra provided coefficients of determination (R2) ranging from 100.0% to 96.8% for the various samples tested. The results acquired from this study provide good evidence for the concept of parallel sonic rays. Further, deconvolution of experimental input and output signals has been shown to provide an effective method to identify echoes otherwise lost due to phase cancellation. Potential applications of pulse-echo ultrasound transit time spectroscopy (PE-UTTS) include improvement of ultrasound image fidelity by improving spatial resolution and reducing phase interference artefacts.
Resumo:
The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R2=99.9% and R2=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.
Resumo:
The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.
Resumo:
Effective processing of powdered particles can facilitate powder handling and result in better drug product performance, which is of great importance in the pharmaceutical industry where the majority of active pharmaceutical ingredients (APIs) are delivered as solid dosage forms. The purpose of this work was to develop a new ultrasound-assisted method for particle surface modification and thin-coating of pharmaceutical powders. The ultrasound was used to produce an aqueous mist with or without a coating agent. By using the proposed technique, it was possible to decrease the interparticular interactions and improve rheological properties of poorly-flowing water-soluble powders by aqueous smoothing of the rough surfaces of irregular particles. In turn, hydrophilic polymer thin-coating of a hydrophobic substance diminished the triboelectrostatic charge transfer and improved the flowability of highly cohesive powder. To determine the coating efficiency of the technique, the bioactive molecule β-galactosidase was layered onto the surface of powdered lactose particles. Enzyme-treated materials were analysed by assaying the quantity of the reaction product generated during enzymatic cleavage of the milk sugar. A near-linear increase in the thickness of the drug layer was obtained during progressive treatment. Using the enzyme coating procedure, it was confirmed that the ultrasound-assisted technique is suitable for processing labile protein materials. In addition, this pre-treatment of milk sugar could be used to improve utilization of lactose-containing formulations for populations suffering from severe lactose intolerance. Furthermore, the applicability of the thin-coating technique for improving homogeneity of low-dose solid dosage forms was shown. The carrier particles coated with API gave rise to uniform distribution of the drug within the powder. The mixture remained homogeneous during further tabletting, whereas the reference physical powder mixture was subject to segregation. In conclusion, ultrasound-assisted surface engineering of pharmaceutical powders can be effective technology for improving formulation and performance of solid dosage forms such as dry powder inhalers (DPI) and direct compression products.
Resumo:
Measurement of loading patterns of the patellar tendon during activity is important in understanding tendon injury. We used transmission-mode ultrasonography to investigate patellar tendon loading during squatting in adults with and without tendinopathy. It was hypothesized that axial ultrasonic velocity, a surrogate measure of the elastic modulus of tendon, would be lower in tendinopathy. Ultrasound velocity was measured in both patellar tendons of adults with unilateral patellar tendinopathy (n=9) and in healthy controls (n=16) during a bilateral squat manoeuvre. Sagittal knee movement was measured simultaneously with an electrogoniometer. Statistical comparisons between healthy and injured tendons were made using 2–way mixed–design ANOVAs. Axial ultrasound velocity in both symptomatic and asymptomatic patellar tendons in tendinopathy was approximately 15% higher than in healthy tendons at the commencement (F1,23=5.2, P<.05) and completion (F1,23=4.5, P<.05) of the squat. While peak velocity was ≈5% higher during both flexion (F1,23=5.4, P<.05) and extension (F1,23=5.3, P<.05) phases, there was no significant between–group difference at the mid–point of the movement. There were no significant differences in the rate and magnitude of knee movement between groups. Although further research is required, these findings suggest enhanced baseline muscle activity in patellar tendinopathy and highlight fresh avenues for its clinical management.
Resumo:
Ultrasound screening is now a routine procedure which forms part of antenatal care provision. Within this routine context ultrasound technology has been found to be generally acceptable and indeed is positively demanded by many women. This paper raises the question whether the routine presentation of ultrasound implicitly conveys the message that is use in antenatal care is both valuable and safe. It examines women's views of ultrasound technology beyond a routine context. In a study designed to examine women's reactions to cerebral ultrasound on their normal term infants mothers were asked their views and knowledge of ultrasound and a comparison with their antenatal experience of ultrasound was elicited. A generalized concern about ultrasound techniques was found to underlie many of the women's comments. This raised questions concerning the current practice in the presentation of ultrasound to women attending for antenatal care.