955 resultados para Multijets ratio
Resumo:
We report a measurement of the ratio of the top-antitop to Z/gamma* production cross sections in sqrt(s) = 1.96 TeV proton-antiproton collisions using data corresponding to an integrated luminosity of up to 4.6 fb-1, collected by the CDF II detector. The top-antitop cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/gamma*->ll cross section, the extracted top-antitop cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result sigma_(top-antitop) = 7.70 +/- 0.52 pb, for a top-quark mass of 172.5 GeV/c^2.
Resumo:
This article presents the first measurement of the ratio of branching fractions B(Λb0→Λc+μ-ν̅ μ)/B(Λb0→Λc+π-). Measurements in two control samples using the same technique B(B̅ 0→D+μ-ν̅ μ)/B(B̅ 0→D+π-) and B(B̅ 0→D*(2010)+μ-ν̅ μ)/B(B̅ 0→D*(2010)+π-) are also reported. The analysis uses data from an integrated luminosity of approximately 172 pb-1 of pp̅ collisions at √s=1.96 TeV, collected with the CDF II detector at the Fermilab Tevatron. The relative branching fractions are measured to be B(Λb0→Λc+μ-ν̅ μ)/B(Λb0→Λc+π-)=16.6±3.0(stat)±1.0(syst)+2.6/-3.4(PDG)±0.3(EBR), B(B̅ 0→D+μ-ν̅ μ)/B(B̅ 0→D+π-)= 9.9±1.0(stat)±0.6(syst)±0.4(PDG)±0.5(EBR), and B(B̅ 0→D*(2010)+μ-ν̅ μ)/B(B̅ 0→D*(2010)+π-)=16.5±2.3(stat)± 0.6(syst)±0.5(PDG)±0.8(EBR). The uncertainties are from statistics (stat), internal systematics (syst), world averages of measurements published by the Particle Data Group or subsidiary measurements in this analysis (PDG), and unmeasured branching fractions estimated from theory (EBR), respectively. This article also presents measurements of the branching fractions of four new Λb0 semileptonic decays: Λb0→Λc(2595)+μ-ν̅ μ, Λb0→Λc(2625)+μ-ν̅ μ, Λb0→Σc(2455)0π+μ-ν̅ μ, and Λb0→Σc(2455)++π-μ-ν̅ μ, relative to the branching fraction of the Λb0→Λc+μ-ν̅ μ decay. Finally, the transverse-momentum distribution of Λb0 baryons produced in pp̅ collisions is measured and found to be significantly different from that of B̅ 0 mesons, which results in a modification in the production cross-section ratio σΛb0/σB̅ 0 with respect to the CDF I measurement.
Resumo:
A combined mass and particle identification fit is used to make the first observation of the decay B̅ s0→Ds±K∓ and measure the branching fraction of B̅ s0→Ds±K∓ relative to B̅ s0→Ds+π-. This analysis uses 1.2 fb-1 integrated luminosity of pp̅ collisions at √s=1.96 TeV collected with the CDF II detector at the Fermilab Tevatron collider. We observe a B̅ s0→Ds±K∓ signal with a statistical significance of 8.1σ and measure B(B̅ s0→Ds±K∓)/B(B̅ s0→Ds+π-)=0.097±0.018(stat)±0.009(syst).
Resumo:
A combined mass and particle identification fit is used to make the first observation of the decay Bs --> Ds K and measure the branching fraction of Bs --> Ds K relative to Bs --> Ds pi. This analysis uses 1.2 fb^-1 integrated luminosity of pbar-p collisions at sqrt(s) = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron collider. We observe a Bs --> Ds K signal with a statistical significance of 8.1 sigma and measure Br(Bs --> Ds K)/Br(Bs --> Ds pi) = 0.097 +- 0.018(stat) +- 0.009(sys).
Resumo:
Using Huxley's solution of the diffusion equation for electron-attaching gases, the ratio of diffusion coefficient D to mobility μ for electrons in dry air was measured over the range 3·06 × 10-17
Resumo:
Yhteenveto: Haihdunnan mittaamisesta ja mallintamisesta peltoalueella
Resumo:
By using the bender and extender elements tests, together with measurements of the travel times of shear (S) and primary (P) waves, the variation of Poisson ratio (nu) was determined for dry sands with respect to changes in relative densities and effective confining pressures (sigma(3)). The tests were performed for three different ranges of particle sizes. The magnitude of the Poisson ratio decreases invariably with an increase in both the relative density and the effective confining pressure. The effect of the confining pressure on the Poisson ratio was found to become relatively more significant for fine-grained sand as compared with the coarse-grained sand. For a given material, at a particular value of sigma(3), the magnitude of the Poisson ratio decreases, almost in a linear fashion, with an increase in the value of maximum shear modulus (G(max)). The two widely used correlations in literature, providing the relationships among G(max), void ratio (e) and effective confining pressure (sigma(3)), applicable for angular granular materials, were found to compare reasonably well with the present experimental data for the fine- and medium-grained sands. However, for the coarse-grained sand, these correlations tend to overestimate the values of G(max).
Resumo:
A three-terminal capacitance bridge is developed for the measurement of the dielectric constant of lossy liquids. Using this modified ratio transformer bridge, the capacitance shunted by a resistance as low as 50 Omega is measured at 10 kHz. The capacitance error associated with the inductance of the connecting wire is compensated using the novel method of introducing an additional transformer to the existing ratio transformer bridge. Other sources of capacitance errors, such as the non-zero output impedence of the ratio transformer and the shield capacitances of the cables, are discussed.
Resumo:
The near flow field of small aspect ratio elliptic turbulent free jets (issuing from nozzle and orifice) was experimentally studied using a 2D PIV. Two point velocity correlations in these jets revealed the extent and orientation of the large scale structures in the major and minor planes. The spatial filtering of the instantaneous velocity field using Gaussian convolution kernel shows that while a single large vortex ring circumscribing the jet seems to be present at the exit of nozzle, the orifice jet exhibited a number of smaller vortex ring pairs close to jet exit. The smaller length scale observed in the case of the orifice jet is representative of the smaller azimuthal vortex rings that generate axial vortex field as they are convected. This results in the axis-switching in the case of orifice jet and may have a mechanism different from the self induction process as observed in the case of contoured nozzle jet flow.
Resumo:
Consanguineous marriages are strongly favoured in the state of Karnataka. Of 65492 marriages studied 33·07% were consanguineous, equivalent to a coefficient of inbreeding (F) of 0·0298. The twinning rate was low, 6·9 per thousand, whereas the secondary sex ratio, 0·5221, was higher than in comparable major human populations. Consanguinity exerted no significant effect on either parameter. The results also indicate that consanguinity is not associated with excess antenatal losses and suggest the possibility of enhanced selection against mutations at X chromosome loci.
Resumo:
For highly compressible normally consolidated saturated soil the compression index, Cc, is not constant over the entire pressure range. However, the ratio of the compression index and the initial specific volume, generally known as the compression ratio, appears to be constant. Thus settlement seems to depend on Cc/(1 + e) rather than Cc alone. Using the theoretical zero air voids line and the generalized compressibility equation for normally consolidated saturated soils, a generalized and simple equation for compression has been derived in the form: C'c = 0.003wL.