214 resultados para Mixer


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ten stage laboratory mixer-settler has been designed, constructed and operated with efficiencies up to 90%. The phase equilibrium data of the system acetic acid-toluene-water at different temperatures has been determined and correlated. Trials for prediction of these data have been investigated and a good agreement between the experimental data and the predictions obtained by the NRTL equation have been found. Extraction processes have been analysed. A model for determination of the time needed for a countercurrent stage-wise process to come to steady state has been derived. The experimental data was in reasonable agreement with this model. The discrete maximum principle has been applied to optimize the countercurrent extraction process and proved to be highly successful in predicting the optimum operating conditions which were confirmed by the experimental results. The temperature has proved to be a prosolvent for mass transfer in both directions but the temperature profile functioned as an anti solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed optical clock recovery, demultiplexing and data regeneration will be integral parts of any future photonic network based on high bit-rate OTDM. Much research has been conducted on devices that perform these functions, however to date each process has been demonstrated independently. A very promising method of all-optical switching is that of a semiconductor optical amplifier-based nonlinear optical loop mirror (SOA-NOLM). This has various advantages compared with the standard fiber NOLM, most notably low switching power, compact size and stability. We use the SOA-NOLM as an all-optical mixer in a classical phase-locked loop arrangement to achieve optical clock recovery, while at the same time achieving data regeneration in a single compact device

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature relating to the extraction of the aromatics, benzene, toluene and xylene (BTX) using different commercial solvents, and to mixer-settler design and performance, has been reviewed. Liquid-liquid equilibria of the ternary systems: hexane-benzene-sulfolane, n-heptane-toluene-sulfolane, and octane-xylene-sulfolane were determined experimentally at temperatures of 30oC, 35oC, and 40oC. The work was then extended to a multicomponent system. The data were correlated by using Hand's method and were found to be in a good agreement with theoretical predictions using the UNIFAC method. A study was made of the performance of a 10-stage laboratory mixer-settler cascade for the extraction of BTX from a synthetic reformate utilizing sulfolane as a solvent. Murphree stage efficiency decreased with stage number but 99% extraction was achievable within 4 stages. The effects of temperature, phase ratio, and agitator speed were investigated. The efficiency increased with agitator speed but > 1050 rpm resulted in secondary haze formation. An optimum temperature of 30oC was selected from the phase equilibria; the optimum solvent: feed ratio was 3:1 for 4 stages. The experimental overall mass transfer coefficients were compared with those predicted from single drop correlations and were in all cases greater, by a factor of 1.5 to 3, due to the surface renewal associated with drop break-up and coalescence promoted by agitation. A similar investigation was performed using real reformate from the Kuwait Oil Company. The phase ratios were in the range 0.5 to 1 to 3.25 to 1, the agitator speed 1050 rpm, and the operating temperature 30oC. A maximum recovery of 99% aromatics was achieved in 4 stages at a phase ratio of 3.25 to 1. A backflow model was extended to simulate conditions in the mixer-settler cascade with this multicomponent system. Overall mass transfer coefficients were estimated by obtaining the best fit between experimental and predicted concentration profiles. They were up to 10% greater than those with the synthetic feed but close agreement was not possible because the distribution coefficient and phase ratio varied with stage number. Sulfolane was demonstrated to be an excellent solvent for BTX recovery and a mixer-settler cascade was concluded to be a technically viable alternative to agitated columns for this process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents an effective methodology for the generation of a simulation which can be used to increase the understanding of viscous fluid processing equipment and aid in their development, design and optimisation. The Hampden RAPRA Torque Rheometer internal batch twin rotor mixer has been simulated with a view to establishing model accuracies, limitations, practicalities and uses. As this research progressed, via the analyses several 'snap-shot' analysis of several rotor configurations using the commercial code Polyflow, it was evident that the model was of some worth and its predictions are in good agreement with the validation experiments, however, several major restrictions were identified. These included poor element form, high man-hour requirements for the construction of each geometry and the absence of the transient term in these models. All, or at least some, of these limitations apply to the numerous attempts to model internal mixes by other researchers and it was clear that there was no generally accepted methodology to provide a practical three-dimensional model which has been adequately validated. This research, unlike others, presents a full complex three-dimensional, transient, non-isothermal, generalised non-Newtonian simulation with wall slip which overcomes these limitations using unmatched ridding and sliding mesh technology adapted from CFX codes. This method yields good element form and, since only one geometry has to be constructed to represent the entire rotor cycle, is extremely beneficial for detailed flow field analysis when used in conjunction with user defined programmes and automatic geometry parameterisation (AGP), and improves accuracy for investigating equipment design and operation conditions. Model validation has been identified as an area which has been neglected by other researchers in this field, especially for time dependent geometries, and has been rigorously pursued in terms of qualitative and quantitative velocity vector analysis of the isothermal, full fill mixing of generalised non-Newtonian fluids, as well as torque comparison, with a relatively high degree of success. This indicates that CFD models of this type can be accurate and perhaps have not been validated to this extent previously because of the inherent difficulties arising from most real processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research project examined the feasibility of using a cavity transfer mixer (CTM) as a continuous reactor to perform reactions between either solid or liquid reagents and polymer melt; reactions which have previously been typically carried out in batch reactor systems. Equipment has been developed to allow uniform and reproducible introduction of reagents into the polymer melt. Reactions have also been performed using batch processing equipment to enable comparison with the performance of the CTM. It was concluded that: a) there are certain reactions which cannot be carried out in a CTM, but which can be performed in a batch system such as a mill or a sigma blade mixer. This was found to be the case for some neutralisation reactions where the product was quasi crosslinked. b) the reactions that can be carried out in a CTM are performed more efficiently in a CTM than on a batch process. For example, when monomers were to be grafted onto polymers, this was more safely and efficiently performed in the CTM than in a mill or a sigma blade mixer. Residence time distributions (RTDs) for three CTMs were studied in order to gain an insight into the effect of CTM geometry on RTD, polymer melt flow pattern and reactor performance. A mathematical model has been developed to predict the influence of process parameters on RTD and the results compared with experimentally observed trends. The comparison was good. A programme of research has been drawn up to form the basis of an industrially based sponsored development project of the CTM reactor. This work programme was successfully marketed to companies with commercial interest in modified rubber and plastics as an integral part of the research programme of this thesis and the sponsored research programme has paralleled the work reported here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed optical clock recovery, demultiplexing and data regeneration will be integral parts of any future photonic network based on high bit-rate OTDM. Much research has been conducted on devices that perform these functions, however to date each process has been demonstrated independently. A very promising method of all-optical switching is that of a semiconductor optical amplifier-based nonlinear optical loop mirror (SOA-NOLM). This has various advantages compared with the standard fiber NOLM, most notably low switching power, compact size and stability. We use the SOA-NOLM as an all-optical mixer in a classical phase-locked loop arrangement to achieve optical clock recovery, while at the same time achieving data regeneration in a single compact device

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of the comonomer content in a series of metallocene-based ethylene-1-octene copolymers (m-LLDPE) on thermo-mechanical, rheological, and thermo-oxidative behaviours during melt processing were examined using a range of characterisation techniques. The amount of branching was calculated from 13C NMR and studies using differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were employed to determine the effect of short chain branching (SCB, comonomer content) on thermal and mechanical characteristics of the polymer. The effect of melt processing at different temperatures on the thermo-oxidative behaviour of the polymers was investigated by examining the changes in rheological properties, using both melt flow and capillary rheometry, and the evolution of oxidation products during processing using infrared spectroscopy. The results show that the comonomer content and catalyst type greatly affect thermal, mechanical and oxidative behaviour of the polymers. For the metallocene polymer series, it was shown from both DSC and DMA that (i) crystallinity and melting temperatures decreased linearly with comonomer content, (ii) the intensity of the ß-transition increased, and (iii) the position of the tan δmax peak corresponding to the a-transition shifted to lower temperatures, with higher comonomer content. In contrast, a corresponding Ziegler polymer containing the same level of SCB as in one of the m-LLDPE polymers, showed different characteristics due to its more heterogeneous nature: higher elongational viscosity, and a double melting peak with broader intensity that occurred at higher temperature (from DSC endotherm) indicating a much broader short chain branch distribution. The thermo-oxidative behaviour of the polymers after melt processing was similarly influenced by the comonomer content. Rheological characteristics and changes in concentrations of carbonyl and the different unsaturated groups, particularly vinyl, vinylidene and trans-vinylene, during processing of m-LLDPE polymers, showed that polymers with lower levels of SCB gave rise to predominantly crosslinking reactions at all processing temperatures. By contrast, chain scission reactions at higher processing temperatures became more favoured in the higher comonomer-containing polymers. Compared to its metallocene analogue, the Ziegler polymer showed a much higher degree of crosslinking at all temperatures because of the high levels of vinyl unsaturation initially present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a 1-10 GHz low-noise downconvert mixer RFIC suitable for wideband receivers. A switched transconductor mixing core is adopted to reduce noise at high frequencies. By adding a series inductor to the RF transconductor, a flat 4-5 dB noise figure (NF) and a high gain of 26.5 dB can be achieved over a broad bandwidth out to 10 GHz. A CMOS output amplifier is also integrated on-chip, employing derivative superposition (DS) for high linearity and an OIP3 of 16.5 dBm. The circuit consumes less than 20 mW of dc power and occupies an active chip area of less than 0.2 mm2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stirring of a body of viscous fluid using multiple stirring rods is known to be particularly effective when the rods trace out a path corresponding to a nontrivial mathematical braid. The optimal braid is the so-called "pigtail braid", in which three stirring rods execute the usual "over-under" motion associated with braiding plaiting) hair. We show how to achieve this optimal braiding motion straightforwardly: one stirring rod is driven in a figure-of-eight motion, while the other two rods are baffles, which rotate episodically about their common centre. We also explore the extent to which the physical baffles may be replaced by flow structures (such as periodic islands).