982 resultados para Micro-ring resonator
Resumo:
We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb D-2 line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs D-2 line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of 10(-10). We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.
Resumo:
The eigenmodes confined in the equilateral triangle resonator (ETR) are analyzed by deriving the eigenvalues and the mode field distributions and by the finite difference time domain (FDTD) technique. The analytical results show that the one-period-length for the mode light rays inside the ETR is the perimeter of the ETR, and the number of transverse modes is limited by the condition of total internal reflection. In addition, the sum of the longitudinal mode index and the transverse mode index should be an even number, which limits the number of confined modes again. Based on the FDTD technique and the Pade approximation, we calculate the mode resonant frequencies and the quality factors from the local maximum and the width of the spectral distribution of the intensity The numerical results of mode frequencies agree very well with the analytical results, and the quality factor of the fundamental mode is usually higher than that of the higher order transverse modes. The results show that the ETR is suitable to realize single-made operation as semiconductor microcavity lasers.
Resumo:
A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.
Resumo:
Tree-ring chronologies are a powerful natural archive to reconstruct summer temperature variations of the late Holocene with an annual resolution. To develop these long-term proxy records tree-ring series are commonly extended back in time by combining samples from living trees with relict dead material preserved onshore or in lakes. Former studies showed that low frequency variations in such reconstructions can be biased if the relict and recent material is from different origins. A detailed analysis of the influence of various ecological (micro-) habitats representing the recent part is required to estimate potential errors in temperature estimates. The application of collective detrending methods, that comprise absolute growth rates, can produce errors in climate reconstructions and results in an underestimation of past temperatures. The appearance of these kind of micro-site effects is a wide-spread phenomenon that takes place all over Fennoscandia. Future research in this key region for dendroclimatology should take this issue into account. Especially the higher climate response at the lakeshore site is interesting to achieve smaller uncertainties when a tree-ring series is transformed to temperature anomalies. For new composite chronologies the main aim should be to minimize potential biases and this includes also micro-site effects.
Resumo:
In whispering gallery mode resonator sensing applications, the conventional way to detect a change in the parameter to be measured is by observing the steady-state transmission spectrum through the coupling waveguide. Alternatively, sensing based on cavity ring-up spectroscopy, i.e. CRUS, can be achieved transiently. In this work, we investigate CRUS using coupled mode equations and find analytical solutions with a large spectral broadening approximation of the input pulse. The relationships between the frequency detuning, coupling gap and ring-up peak height are determined and experimentally verified using an ultrahigh Q-factor silica microsphere. This work shows that distinctive dispersive and dissipative transient sensing can be realised by simply measuring the peak height of the CRUS signal, which may improve the data collection rate.
Resumo:
The macerals in bituminous coals with varying organic sulfur content from the Early Permian Greta Coal Measures at three locations (Southland Colliery, Drayton Colliery and the Cranky Corner Basin), in and around the Sydney Basin (Australia), have been studied using light-element electron microprobe (EMP) analysis and micro-ATR–FTIR. Electron microprobe analysis of individual macerals reveals that the vitrinite in both the Cranky Corner Basin and Drayton Colliery (Puxtrees seam) samples have similar carbon contents (ca. 78% C in telocollinite), suggesting that they are of equivalent rank. However, the Cranky Corner coals have anomalously low vitrinite reflectance (down to 0.45%) vs. the Drayton materials (ca. 0.7%). They also have very high organic S content (3–6.5%) and lower O content (ca. 10%) than the equivalent macerals in the Drayton sample (0.7% S and 15.6% O). A study was carried out to investigate the impacts of the high organic S on the functional groups of the macerals in these two otherwise iso-rank, stratigraphically-equivalent seams. An iso-rank low-S coal from the overlying Wittingham Coal Measures near Muswellbrook and coals of slightly higher rank from the Greta Coal Measures at Southland Colliery near Cessnock were also evaluated using the same techniques to extend the data set. Although the telocollinite in the Drayton and Cranky Corner coals have very similar carbon content (ca.78% C), the ATR–FTIR spectra of the vitrinite and inertinite macerals in these respectively low S and high S coals show some distinct differences in IR absorbance from various aliphatic and aromatic functional groups. The differences in absorbance of the aliphatic stretching bands (2800–3000 cm−1) and the aromatic carbon (CC) peak at 1606 cm−1 are very obvious. Compared to that of the Drayton sample (0.7% S and 15% O), the telocollinite of the Cranky Corner coal (6% S and 10% O) clearly shows: (i) less absorbance from OH groups, represented by a broad region around 3553 cm−1, (ii) much stronger aliphatic C–H absorbance (stretching modes around 3000–2800 cm−1 and bending modes around 1442 cm−1) and (iii) less absorbance from aromatic carbon functional groups (peaking at 1606 cm−1). Evaluation of the iso-rank Drayton and Cranky Corner coals shows that: (i) the aliphatic C–H absorbances decrease with increasing oxygen content but increase with increasing organic S content and (ii) the aromatic H to aliphatic H ratio (Har/Hali) for the telocollinite increases with (organic) O%, but decreases progressively with increasing organic S. The high organic S content in the maceral appears to be accompanied by a greater proportion of aliphatic functional groups, possibly as a result of some of the O within maceral ring structures in the high S coal samples being replaced.
Resumo:
Microbial degradation pathways play a key role in the detoxification and the mineralization of polyaromatic hydrocarbons (PAHs), which are widespread pollutants in soil and constituents of petroleum hydrocarbons. In microbiology the aromatic degradation pathways are traditionally studied from single bacterial strains with capacity to degrade certain pollutant. In soil the degradation of aromatics is performed by a diverse community of micro-organisms. The aim of this thesis was to study biodegradation on different levels starting from a versatile aromatic degrader Sphingobium sp. HV3 and its megaplasmid, extending to revelation of diversity of key catabolic enzymes in the environment and finally studying birch rhizoremediation in PAH-polluted soil. To understand biodegradation of aromatics on bacterial species level, the aromatic degradation capacity of Sphingobium sp. HV3 and the role of the plasmid pSKY4, was studied. Toluene, m-xylene, biphenyl, fluorene, phenanthrene were detected as carbon and energy sources of the HV3 strain. Tn5 transposon mutagenesis linked the degradation capacity of toluene, m-xylene, biphenyl and naphthalene to the pSKY4 plasmid and qPCR expression analysis showed that plasmid extradiol dioxygenases genes (bphC and xylE) are inducted by phenanthrene, m-xylene and biphenyl whereas the 2,4-dichlorophenoxyacetic acid herbicide induced the chlorocatechol 1,2-dioxygenase gene (tfdC) from the ortho-pathway. A method to study upper meta-pathway extradiol dioxygenase gene diversity in soil was developed. The extradiol dioxygenases catalyse cleavage of the aromatic ring between a hydroxylated carbon and an adjacent non-hydroxylated carbon (meta-cleavage). A high diversity of extradiol dioxygenases were detected from polluted soils. The detected extradiol dioxygenases showed sequence similarity to known catabolic genes of Alpha-, Beta-, and Gammaproteobacteria. Five groups of extradiol dioxygenases contained sequences with no close homologues in the database, representing novel genes. In rhizoremediation experiment with birch (Betula pendula) treatment specific changes of extradiol dioxygenase communities were shown. PAH pollution changed the bulk soil extradiol dioxygenase community structure and birch rhizosphere contained a more diverse extradiol dioxygenase community than the bulk soil showing a rhizosphere effect. The degradation of pyrene in soil was enhanced with birch seedlings compared to soil without birch. The complete 280,923 kb nucleotide sequence of pSKY4 plasmid was determined. The open reading frames of pSKY4 were divided into putative conjugative transfer, aromatic degradation, replication/maintaining and transposition/integration function-encoding proteins. Aromatic degradation orfs shared high similarity to corresponding genes in pNL1, a plasmid from the deep subsurface strain Novosphingobium aromaticivorans F199. The plasmid backbones were considerably more divergent with lower similarity, which suggests that the aromatic pathway has functioned as a plasmid independent mobile genetic element. The functional diversity of microbial communities in soil is still largely unknown. Several novel clusters of extradiol dioxygenases representing catabolic bacteria, whose function, biodegradation pathways and phylogenetic position is not known were amplified with single primer pair from polluted soils. These extradiol dioxygenase communities were shown to change upon PAH pollution, which indicates that their hosts function in PAH biodegradation in soil. Although the degradation pathways of specific bacterial species are substantially better depicted than pathways in situ, the evolution of degradation pathways for the xenobiotic compounds is largely unknown. The pSKY4 plasmid contains aromatic degradation genes in putative mobile genetic element causing flexibility/instability to the pathway. The localisation of the aromatic biodegradation pathway in mobile genetic elements suggests that gene transfer and rearrangements are a competetive advantage for Sphingomonas bacteria in the environment.
Resumo:
We report the simulation and analytical results obtained for homogenous or bulk sensing of protein on Siliconon- insulator strip waveguide based microring resonator. The radii of the rings considered are 5 μm and 20 μm; the waveguide dimensions are 300 × 300 nm. A gap of (i) 200 nm and (ii) 300 nm exists between the ring and the bus waveguide. The biomaterial is uniformly distributed over a thickness which exceeds the evanescent field penetration depth of 150 nm. The sensitivities of the resonators are 32.5 nm/RIU and 17.5 nm/RIU (RIU - Refractive index unit) respectively.
Resumo:
Micro- and nano-mechanical resonators have been proposed for a variety of applications ranging from mass sensing to signal processing. Often their actuation and/or detection involve external subsystems that are much larger than the resonator itself. We have designed a simple microcantilever resonator with integrated sensor and actuator, facilitating the integration of large arrays of resonators. This unique design can be manufactured with a low-cost fabrication process, involving just a single step of lithography. The bilayer cantilever of gold and silicon dioxide is used as piezoresistive sensor as well as thermal bimorph actuator. The ac current used for actuation and the dc current used for piezoresistive detection are separated in the frequency-domain using a bias-tee circuit configuration. The resonant response is measured by detecting the second harmonic of the actuation current using a lock-in amplifier.