990 resultados para Measuring parameters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the use of actigraphy in depression research, the association of depression ratings and quantitative motor activity remains controversial. In addition, the impact of recurring episodes on motor activity is uncertain. In 76 medicated inpatients with major depression (27 with a first episode, 49 with recurrent episodes), continuous wrist actigraphy for 24h and scores on the Hamilton Depression Rating Scale (HAMD) were obtained. In addition, 10 subjects of the sample wore the actigraph over a period of 5 days, in order to assess the reliability of a 1-day measurement. Activity levels were stable over 5 consecutive days. Actigraphic parameters did not differ between patients with a first or a recurrent episode, and quantitative motor activity failed to correlate with the HAMD total score. However, of the motor-related single items of the HAMD, the item activities was associated with motor activity parameters, while the items agitation and retardation were not. Actigraphy is consistent with clinical observation for the item activities. Expert raters may not correctly rate the motor aspects of retardation and agitation in major depression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Testing a new method of nanoindentation using the atomic force microscope (AFM) was the purpose of this research. Nanoindentation is a useful technique to study the properties of materials on the sub-micron scale. The AFM has been used as a nanoindenter previously; however several parameters needed to obtain accurate results, including tip radius and cantilever sensitivity, can be difficult to determine. To solve this problem, a new method to determine the elastic modulus of a material using the atomic force microscope (AFM) has been proposed by Tang et al. This method models the cantilever and the sample as two springs in a series. The ratio of the cantilever spring constant (k) to diameter of the tip (2a) is treated in the model as one parameter (α=k/2a). The value of a, along with the cantilever sensitivity, are determined on two reference samples with known mechanical properties and then used to find the elastic modulus of an unknown sample. To determine the reliability and accuracy of this technique, it was tested on several polymers. Traditional depth-sensing nanoindentation was preformed for comparison. The elastic modulus values from the AFM were shown to be statistically similar to the nanoindenter results for three of the five samples tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the effects of cognitive-behavioral stress management (CBSM) training on clinical and psychosocial markers in HIV-infected persons. METHODS: A randomized controlled trial in four HIV outpatient clinics of 104 HIV-infected persons taking combination antiretroviral therapy (cART), measuring HIV-1 surrogate markers, adherence to therapy and well-being 12 months after 12 group sessions of 2 h CBSM training. RESULTS: Intent-to-treat analyses showed no effects on HIV-1 surrogate markers in the CBSM group compared with the control group: HIV-1 RNA < 50 copies/ml in 81.1% [95% confidence interval (CI), 68.0-90.6] and 74.5% (95% CI, 60.4-85.7), respectively (P = 0.34), and mean CD4 cell change from baseline of 53.0 cells/microl (95% CI, 4.1-101.8) and 15.5 cells/microl (95% CI, -34.3 to 65.4), respectively (P = 0.29). Self-reported adherence to therapy did not differ between groups at baseline (P = 0.53) or at 12 month's post-intervention (P = 0.47). Significant benefits of CBSM over no intervention were observed in mean change of quality of life scores: physical health 2.9 (95% CI, 0.7-5.1) and -0.2 (95% CI, -2.1 to 1.8), respectively (P = 0.05); mental health 4.8 (95% CI, 1.8-7.3) and -0.5 (95% CI, -3.3 to 2.2) (P = 0.02); anxiety -2.1 (95% CI, -3.6 to -1.0) and 0.3 (95% CI, -0.7 to 1.4), respectively (P = 0.002); and depression -2.1 (95% CI, -3.2 to -0.9) and 0.02 (95% CI, -1.0 to 1.1), respectively (P = 0.001). Alleviation of depression and anxiety symptoms were most pronounced among participants with high psychological distress at baseline. CONCLUSION: CBSM training of HIV-infected persons taking on cART does not improve clinical outcome but has lasting effects on quality of life and psychological well-being.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A patient classification system was developed integrating a patient acuity instrument with a computerized nursing distribution method based on a linear programming model. The system was designed for real-time measurement of patient acuity (workload) and allocation of nursing personnel to optimize the utilization of resources.^ The acuity instrument was a prototype tool with eight categories of patients defined by patient severity and nursing intensity parameters. From this tool, the demand for nursing care was defined in patient points with one point equal to one hour of RN time. Validity and reliability of the instrument was determined as follows: (1) Content validity by a panel of expert nurses; (2) predictive validity through a paired t-test analysis of preshift and postshift categorization of patients; (3) initial reliability by a one month pilot of the instrument in a practice setting; and (4) interrater reliability by the Kappa statistic.^ The nursing distribution system was a linear programming model using a branch and bound technique for obtaining integer solutions. The objective function was to minimize the total number of nursing personnel used by optimally assigning the staff to meet the acuity needs of the units. A penalty weight was used as a coefficient of the objective function variables to define priorities for allocation of staff.^ The demand constraints were requirements to meet the total acuity points needed for each unit and to have a minimum number of RNs on each unit. Supply constraints were: (1) total availability of each type of staff and the value of that staff member (value was determined relative to that type of staff's ability to perform the job function of an RN (i.e., value for eight hours RN = 8 points, LVN = 6 points); (2) number of personnel available for floating between units.^ The capability of the model to assign staff quantitatively and qualitatively equal to the manual method was established by a thirty day comparison. Sensitivity testing demonstrated appropriate adjustment of the optimal solution to changes in penalty coefficients in the objective function and to acuity totals in the demand constraints.^ Further investigation of the model documented: correct adjustment of assignments in response to staff value changes; and cost minimization by an addition of a dollar coefficient to the objective function. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Growth in plants results from the interaction between genetic and signalling networks and the mechanical properties of cells and tissues. There has been a recent resurgence in research directed at understanding the mechanical aspects of growth, and their feedback on genetic regulation. This has been driven in part by the development of new micro-indentation techniques to measure the mechanical properties of plant cells in vivo. However, the interpretation of indentation experiments remains a challenge, since the force measures results from a combination of turgor pressure, cell wall stiffness, and cell and indenter geometry. In order to interpret the measurements, an accurate mechanical model of the experiment is required. Here, we used a plant cell system with a simple geometry, Nicotiana tabacum Bright Yellow-2 (BY-2) cells, to examine the sensitivity of micro-indentation to a variety of mechanical and experimental parameters. Using a finite-element mechanical model, we found that, for indentations of a few microns on turgid cells, the measurements were mostly sensitive to turgor pressure and the radius of the cell, and not to the exact indenter shape or elastic properties of the cell wall. By complementing indentation experiments with osmotic experiments to measure the elastic strain in turgid cells, we could fit the model to both turgor pressure and cell wall elasticity. This allowed us to interpret apparent stiffness values in terms of meaningful physical parameters that are relevant for morphogenesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we develop a methodology to summarize the various policy parameters of an unemployment insurance scheme into a single generosity parameter. Unemployment insurance policies are multdimensional objects. They are typically defined by waiting periods, eligibility duration, benefit levels and asset tests when eligible, which makes intertemporal or international comparisons difficult. To make things worse, labor market conditions, such as the likelihood and duration of unemployment matter when assessing the generosity of different policies. We build a first model with such complex characteristics. Our model features heterogeneous agents that are liquidity constrained but can self-insure. We then build a second model that is similar, except that the unemployment insurance is simpler: it is deprived of waiting periods and agents are eligible forever with constant benefits. We then determine which level of benefits in this second model makes agents indifferent between both unemployment insurance policies. We apply this strategy to the unemployment insurance program of the United Kingdom and study how its generosity evolved over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study sites. Samples of surface water were taken from 4 coastal lagoons on the Yucatan Peninsula in Mexico: Celestun (20° 45' N - 90° 22' W), Chelem (21° 15' N - 89° 45' W), Rosada Lagoon (21º 19' N - 89º 19' W), and Sabancuy Estuary (18° 58' N - 91° 12' W). The sampling was performed from august to October of 2011 (Chelem 08/24; Laguna Rosada 09/06; Celestún 09/28; Sabancuy 10/25). The sampling was random without replacement and 10 samples of surface water were collected along a transect parallel to the coastal axis. Samples were deposited in sterile plastic bottles and conserved in refrigeration at 4°C. All samples were processed within 24 hours after sampling. According to the Mexican laws and regulations no permissions are required to obtain water and sediment samples from open public areas. Analysis of environmental and physicochemical parameters. Determinations of the environmental parameters were performed with a Hach 5465000 model 156 multi-parameter measuring instrument. The Lorenzen method was used to determine chlorophyll-a (21) with 90% acetone and the concentration was calculated according to the formula: Chla= 27.63 (OD665o - OD665a)(VA)/VM x L Where, OD665o: absorbance at 665 nm before acidification; OD665a: absorbance at 665 nm after acidification; VA: volume (ml) of acetone for extraction; VM: volume (ml) of filtered water; L: length (cm) of the photometric cell. Determinations of the physicochemical parameters (silicates, phosphates, nitrates, nitrites and ammonia) were performed using the spectrophotometric techniques described and modified by Strickland and Parsons (1972).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El principal objetivo de este estudio es evaluar la influencia de las fendas de secado en las propiedades mecánicas de vigas de madera. Para esto, se utilizan 40 vigas de Pino silvestre (Pinus sylvestris L) de 4200 mm de longitud y 150x200 mm de sección que fueron ensayadas según norma EN 408. Las fendas se registran detalladamente atendiendo a su longitud y posición en cada cara de la viga, y midiendo el espesor y la profundidad cada 100mm a lo largo de la viga. Solo el 10% de la muestra es rechazada por las fendas, según los criterios establecidos por la norma española de clasificación visual UNE 56544. Para evaluar la influencia de las fendas en las propiedades mecánicas, se usan tres parámetros globales basados en el área, el volumen o la profundad de la fenda, y dos locales basados en la profundidad máxima y la profundidad en la zona de rotura. Además se determina la densidad de las piezas. Estos parámetros se comparan con las propiedades mecánicas (tensión de rotura, módulo de elasticidad y energía de rotura) y se encuentra escasa relación entre ellos. Las mejores correlaciones se encuentran entre los parámetros relacionados con la profundidad de las fendas, tanto con el módulo de elasticidad como con la tensión de rotura. The aim of this study is the evaluation of the influence of drying fissures on the mechanical properties of timber beams. For that purpose, 40 sawn timber pieces of Scots pine (Pinus sylvestris L.) with 150x200 mm in cross-section and 4200 mm in length have been tested according to EN 408, obtaining MOR and MOE. The fissures were registered in detail measuring their length and position in each face of the beam, and the thickness and depth every 100 mm in length. Only 10 % of the pieces were rejected because fissures, according to UNE 56544 Spanish visual grading standard. To evaluate the influence of fissures in mechanical properties three global parameters: Fissures Area Ratio or ratio between the area occupied by fissures and the total area in the neutral axis plane of the beam; Fissures Volume Ratio or ratio between volume of fissures and the total volume of the beam; Fissures Average Depth and two local parameters were used: Fissures Maximum Depth in the beam, and Fissures Depth in the broken zone of the beam. Also the density of the beams was registered. These parameters were compared with mechanical properties (tensile strength, elasticity modulus, and rupture energy) and the relationship between them had not been founded. The best relationship was founded between the elasticity modulus y the tensile strength with the parameters which included the depth of the fissures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different parameters are used to quantify the maturity of fruits at or near harvest (shape, color, flesh texture and internal composition). Flesh firmness is a critical handling parameter for fruits such as peach, pear and apple. Results of previous studies conducted by different researchers have shown that impact techniques can be used to evaluate firmness of fruits. A prototype impact system for firmness sorting of fruits was developed by Chen and Ruiz-Altisent (Chen et al, 1996). This sensor was mounted and tested successfully on a 3 m section of a commercial conveyor belt (Chen et al, 1998). This is a further development of the on-line impact system for firmness sorting of fruits. The design of the sensor has been improved and it has been mounted on a experimental fruit packing line (Ortiz-Cañavate et al 1999).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On-line partial discharge (PD) measurements have become a common technique for assessing the insulation condition of installed high voltage (HV) insulated cables. When on-line tests are performed in noisy environments, or when more than one source of pulse-shaped signals are present in a cable system, it is difficult to perform accurate diagnoses. In these cases, an adequate selection of the non-conventional measuring technique and the implementation of effective signal processing tools are essential for a correct evaluation of the insulation degradation. Once a specific noise rejection filter is applied, many signals can be identified as potential PD pulses, therefore, a classification tool to discriminate the PD sources involved is required. This paper proposes an efficient method for the classification of PD signals and pulse-type noise interferences measured in power cables with HFCT sensors. By using a signal feature generation algorithm, representative parameters associated to the waveform of each pulse acquired are calculated so that they can be separated in different clusters. The efficiency of the clustering technique proposed is demonstrated through an example with three different PD sources and several pulse-shaped interferences measured simultaneously in a cable system with a high frequency current transformer (HFCT).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper illustrates how to design a visual experiment to measure color differences in gonioapparent materials and how to assess the merits of different advanced color-difference formulas trying to predict the results of such experiment. Successful color-difference formulas are necessary for industrial quality control and artificial color-vision applications. A color- difference formula must be accurate under a wide variety of experimental conditions including the use of challenging materials like, for example, gonioapparent samples. Improving the experimental design in a previous paper [Melgosaet al., Optics Express 22, 3458-3467 (2014)], we have tested 11 advanced color-difference formulas from visual assessments performed by a panel of 11 observers with normal colorvision using a set of 56 nearly achromatic colorpairs of automotive gonioapparent samples. Best predictions of our experimental results were found for the AUDI2000 color-difference formula, followed by color-difference formulas based on the color appearance model CIECAM02. Parameters in the original weighting function for lightness in the AUDI2000 formula were optimized obtaining small improvements. However, a power function from results provided by the AUDI2000 formula considerably improved results, producing values close to the inter-observer variability in our visual experiment. Additional research is required to obtain a modified AUDI2000 color-difference formula significantly better than the current one.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we described an efficient theoretical approach to determine the integral characteristics such as Mode Field Diameter (MFD) and V-parameter of the Weakly guiding waveguides. To test the described method we measured MFD for the commercially available step index single mode fibre with known parameters. The results of these measurements are presented for two different wavelengths. It is worth noting that the developed approach implies infinite cladding, thus care should be taken to avoid influence of finiteness of cladding when MFD compares to cladding diamete.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we described an efficient theoretical approach to determine the integral characteristics such as Mode Field Diameter (MFD) and V-parameter of the Weakly guiding waveguides. To test the described method we measured MFD for the commercially available step index single mode fibre with known parameters. The results of these measurements are presented for two different wavelengths. It is worth noting that the developed approach implies infinite cladding, thus care should be taken to avoid influence of finiteness of cladding when MFD compares to cladding diamete.