819 resultados para Measure Vertebral Rotation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is the most common form of spinal deformity in paediatrics, prevalent in approximately 2-4% of the general population. While it is a complex three-dimensional deformity, it is clinically characterised by an abnormal lateral curvature of the spine. The treatment for severe deformity is surgical correction with the use of structural implants. Anterior single rod correction employs a solid rod connected to the anterior spine via vertebral body screws. Correction is achieved by applying compression between adjacent vertebral body screws, before locking each screw onto the rod. Biomechanical complication rates have been reported as high as 20.8%, and include rod breakage, screw pull-out and loss of correction. Currently, the corrective forces applied to the spine are unknown. These forces are important variables to consider in understanding the biomechanics of scoliosis correction. The purpose of this study was to measure these forces intra-operatively during anterior single rod AIS correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an initiative in the Faculty of Health at the Queensland University of Technology, Australia, where a short writing task was introduced to first year undergraduates in four courses including Public Health, Nursing, Social Work and Human Services, and Human Movement Studies. Over 1,000 students were involved in the trial. The task was assessed using an adaptation of the MASUS Procedure (Measuring the Academic Skills of University Students) (Webb & Bonanno, 1994). Feedback to the students including MASUS scores then enabled students to be directed to developmental workshops targeting their academic literacy needs. Students who achieved below the benchmark score were required to attend academic writing workshops in order to obtain the same summative 10% that was obtained by those who had achieved above the benchmark score. The trial was very informative, in terms of determining task appropriateness and timing, student feedback, student use of support, and student perceptions of the task and follow-up workshops. What we learned from the trial will be presented with a view to further refinement of this initiative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transportation disadvantage has been recognised to be the key source of social exclusion. Therefore an appropriate process is required to investigate and seek to resolve this problem. Currently, determination of Transportation Disadvantage is postulate based on income, poverty and mobility level. Transportation disadvantage may best regard be based on accessibility perspectives as they represent inability of the individual to access desired activities. This paper attempts to justify a process in determining transportation disadvantage by incorporating accessibility and social transporation conflict as the essence of a framework. The framework embeds space time organisation within the dimension of accessibility to identify a rigorous definition of transportation disadvantage. In developing the framework, the definition, dimension, component and measure of accessibility were scrutinised. The findings suggest the definition and dimension are the significant approach of research to evaluate travel experience of the disadvantaged. Concurrently, location accessibility measures will be incorprated to strenghten the determination of accessibility level. Literature review in social exclusion and mobility-related exclusion identified the dimension and source of transportation disadvantage. It was revealed that the appropriate approach to justify trasnportation disadvantaged is to incorporate space-time organisation within the studied components. The suggested framework is an inter-related process consisting of component of accessibility; individual, networking (transport system) and activities (destination). The integration and correlation among the components shall determine the level of transportation disadvantage. Prior findings are used to retrieve the spatial distribution of transportation disadvantaged and appropriate policies are developed to resolve the problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an implementation of an aircraft pose and motion estimator using visual systems as the principal sensor for controlling an Unmanned Aerial Vehicle (UAV) or as a redundant system for an Inertial Measure Unit (IMU) and gyros sensors. First, we explore the applications of the unified theory for central catadioptric cameras for attitude and heading estimation, explaining how the skyline is projected on the catadioptric image and how it is segmented and used to calculate the UAV’s attitude. Then we use appearance images to obtain a visual compass, and we calculate the relative rotation and heading of the aerial vehicle. Additionally, we show the use of a stereo system to calculate the aircraft height and to measure the UAV’s motion. Finally, we present a visual tracking system based on Fuzzy controllers working in both a UAV and a camera pan and tilt platform. Every part is tested using the UAV COLIBRI platform to validate the different approaches, which include comparison of the estimated data with the inertial values measured onboard the helicopter platform and the validation of the tracking schemes on real flights.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate whether venous occlusion plethysmography (VOP) may be used to measure high rates of arterial inflow associated with exercise, venous occlusions were performed at rest, and following dynamic handgrip exercise at 15, 30, 45, and 60 % of maximum voluntary contraction (MVC) in seven healthy males. The effect of including more than one cardiac cycle in the calculation of blood flow was assessed by comparing the cumulative blood flow over one, two, three, or four cardiac cycles. The inclusion of more than one cardiac cycle at 30 and 60 % MVC, and more than two cardiac cycles at 15 and 45 % MVC resulted in a lower blood flow compared to using only the first cardiac cycle (P < 0.05). Despite the small time interval over which arterial inflow was measured (~1 second), this did not affect the reproducibility of the technique. Reproducibility (coefficient of variation for arterial inflow over three trials) tended to be poorer at the higher workloads, although this was not significant (12.7 ± 6.6 %, 16.2 ± 7.3 %, and 22.9 ± 9.9 % for the 15, 30, and 45 % MVC workloads; P=0.102). There was also a tendency for greater reproducibility with the inclusion of more cardiac cycles at the highest workload, but this did not reach significance (P=0.070). In conclusion, when calculated over the first cardiac cycle only during venous occlusion, high rates of FBF can be measured using VOP, and this can be achieved without a significant decrease in the reproducibility of the measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the psychometric properties of a Chinese version of the Diabetes Coping Measure (DCM-C) scale.----- Methods: A self-administered questionnaire was completed by 205 people with type 2 diabetes from the endocrine outpatient departments of three hospitals in Taiwan. Confirmatory factor analysis, criterion validity, and internal consistency reliability were conducted to evaluate the psychometric properties of the DCM-C.----- Findings: Confirmatory factor analysis confirmed a four-factor structure (χ2 /df ratio=1.351, GFI=.904, CFI=.902, RMSEA=.041). The DCM-C was significantly associated with HbA1c and diabetes self-care behaviors. Internal consistency reliability of the total DCM-C scale was .74. Cronbach’s alpha coefficients for each subscale of the DCM-C ranged from .37 (tackling spirit) to .66 (diabetes integration).----- Conclusions: The DCM-C demonstrated satisfactory reliability and validity to determine the use of diabetes coping strategies. The tackling spirit dimension needs further refinement when applies this scale to Chinese populations with diabetes.----- Clinical Relevance: Healthcare providers who deal with Chinese people with diabetes can use the DCM-C to implement an early determination of diabetes coping strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delirium is a disorder of acute onset with fluctuating symptoms and is characterized by inattention, disorganized thinking, and altered levels of consciousness. The risk for delirium is greatest in individuals with dementia, and the incidence of both is increasing worldwide because of the aging of our population. Although several clinical trials have tested interventions for delirium prevention in individuals without dementia, little is known about the mechanisms for the prevention of delirium in early-stage Alzheimer’s disease (AD). The purpose of this article is to explore ways of preventing delirium and slowing the rate of cognitive decline in early-stage AD by enhancing cognitive reserve. An agenda for future research on interventions to prevent delirium in individuals with early-stage AD is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frontline employee behaviours are recognised as vital for achieving a competitive advantage for service organisations. The services marketing literature has comprehensively examined ways to improve frontline employee behaviours in service delivery and recovery. However, limited attention has been paid to frontline employee behaviours that favour customers in ways that go against organisational norms or rules. This study examines these behaviours by introducing a behavioural concept of Customer-Oriented Deviance (COD). COD is defined as, “frontline employees exhibiting extra-role behaviours that they perceive to defy existing expectations or prescribed rules of higher authority through service adaptation, communication and use of resources to benefit customers during interpersonal service encounters.” This thesis develops a COD measure and examines the key determinants of these behaviours from a frontline employee perspective. Existing research on similar behaviours that has originated in the positive deviance and pro-social behaviour domains has limitations and is considered inadequate to examine COD in the services context. The absence of a well-developed body of knowledge on non-conforming service behaviours has implications for both theory and practice. The provision of ‘special favours’ increases customer satisfaction but the over-servicing of customers is also counterproductive for the service delivery and costly for the organisation. Despite these implications of non-conforming service behaviours, there is little understanding about the nature of these behaviours and its key drivers. This research builds on inadequacies in prior research on positive deviance, pro-social and pro-customer literature to develop the theoretical foundation of COD. The concept of positive deviance which has predominantly been used to study organisational behaviours is applied within a services marketing setting. Further, it addresses previous limitations in pro-social and pro-customer behavioural literature that has examined limited forms of behaviours with no clear understanding on the nature of these behaviours. Building upon these literature streams, this research adopts a holistic approach towards the conceptualisation of COD. It addresses previous shortcomings in the literature by providing a well bounded definition, developing a psychometrically sound measure of COD and a conceptually well-founded model of COD. The concept of COD was examined across three separate studies and based on the theoretical foundations of role theory and social identity theory. Study 1 was exploratory and based on in-depth interviews using the Critical Incident Technique (CIT). The aim of Study 1 was to understand the nature of COD and qualitatively identify its key drivers. Thematic analysis was conducted to analyse the data and the two potential dimensions of COD behaviours of Deviant Service Adaptation (DSA) and Deviant Service Communication (DSC) were revealed in the analysis. In addition, themes representing the potential influences of COD were broadly classified as individual factors, situational factors, and organisational factors. Study 2 was a scale development procedure that involved the generation and purification of items for the measure based on two student samples working in customer service roles (Pilot sample, N=278; Initial validation sample, N=231). The results for the reliability and Exploratory Factor Analyses (EFA) on the pilot sample suggested the scale had poor psychometric properties. As a result, major revisions were made in terms of item wordings and new items were developed based on the literature to reflect a new dimension, Deviant Use of Resources (DUR). The revised items were tested on the initial validation sample with the EFA analysis suggesting a four-factor structure of COD. The aim of Study 3 was to further purify the COD measure and test for nomological validity based on its theoretical relationships with key antecedents and similar constructs (key correlates). The theoretical model of COD consisting of nine hypotheses was tested on a retail and hospitality sample of frontline employees (Retail N=311; Hospitality N=305) of a market research panel using an online survey. The data was analysed using Structural Equation Modelling (SEM). The results provided support for a re-specified second-order three-factor model of COD which consists of 11 items. Overall, the COD measure was found to be reliable and valid, demonstrating convergent validity, discriminant validity and marginal partial invariance for the factor loadings. The results showed support for nomological validity, although the antecedents had differing impact on COD across samples. Specifically, empathy and perspective-taking, role conflict, and job autonomy significantly influenced COD in the retail sample, whereas empathy and perspective-taking, risk-taking propensity and role conflict were significant predictors in the hospitality sample. In addition, customer orientation-selling orientation, the altruistic dimension of organisational citizenship behaviours, workplace deviance, and social desirability responding were found to correlate with COD. This research makes several contributions to theory. First, the findings of this thesis extend the literature on positive deviance, pro-social and pro-customer behaviours. Second, the research provides an empirically tested model which describes the antecedents of COD. Third, this research contributes by providing a reliable and valid measure of COD. Finally, the research investigates the differential effects of the key antecedents in different service sectors on COD. The research findings also contribute to services marketing practice. Based on the research findings, service practitioners can better understand the phenomenon of COD and utilise the measurement tool to calibrate COD levels within their organisations. Knowledge on the key determinants of COD will help improve recruitment and training programs and drive internal initiatives within the firm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the wake of recent corporate collapses, 'corporate governance' has received unprecedented levels of attention. It can be narrowly defined as how a company is directed and steered. The responsibility of steering a company is entrusted with the board of directors, who become the focus of governance mechanisms.Yet this is not as straightforward as it appears - Australia has experienced massive shifts in business regulations over the past two decades. One innovation in Australian business regulation is 'enforced self-regulation' which combines the benefits of voluntary self-regulation with the coercive power of the State, implemented via a compliance program. A possible hazard of compliance system is that management might treat this responsibility as a 'box ticking' exercise. Therefore effective governance and compliance entails more than setting up internal and regulatory mechanisms; the willingness of various stakeholders to collaborate is crucial. This suggests that managing relationships between stakeholders of an organization is the key to averting corporate collapses.