991 resultados para Masonry structures
Resumo:
The development of infrastructure in major cities often involves tunnelling, which can cause damage to existing structures. Therefore, these projects require a careful prediction of the risk of settlement induced damage. The simplified approach of current methods cannot account for three-dimensional structural aspects of buildings, which can result in an inaccurate evaluation of damage. This paper investigates the effect of the building alignment with the tunnel axis on structural damage. A three-dimensional, phased, fully coupled finite element model with non-linear material properties is used as a tool to perform a parametric study. The model includes the simulation of the tunnel construction process, with the tunnel located adjacent to a masonry building. Three different type of settlements are included (sagging, hogging and a combination of them), with seven different increasing angles of the building with respect to the tunnel axis. The alignment parameter is assessed, based on the maximum occurring crack width, measured in the building. Results show a significant dependency of the final damage on the building and tunnel alignment.
Resumo:
Externally bonding of FRP composites is an effective technique for retrofitting historical masonry arch structures. A major failure mode in such strengthened structures is the debonding of FRP from the masonry. The bond behaviour between FRP and masonry thus plays a crucial role in these structures. Major challenges exist in the finite element modelling of such structures, such as modelling of mixed Mode-I and Mode-II bond behaviour between the FRP and the curved masonry substrate, modelling of existing damages in the masonry arches, consideration of loading history in the unstrengthened and strengthened structure etc. This paper presents a rigorous FE model for simulating FRP strengthened masonry arch structures. A detailed solid model was developed for simulating the masonry and a mixed-mode interface model was used for simulating the FRP-to-masonry bond behaviour. The model produces results in very close agreement with test results.
Resumo:
This research has focused on the study of the behavior and of the collapse of masonry arch bridges. The latest decades have seen an increasing interest in this structural type, that is still present and in use, despite the passage of time and the variation of the transport means. Several strategies have been developed during the time to simulate the response of this type of structures, although even today there is no generally accepted standard one for assessment of masonry arch bridges. The aim of this thesis is to compare the principal analytical and numerical methods existing in literature on case studies, trying to highlight values and weaknesses. The methods taken in exam are mainly three: i) the Thrust Line Analysis Method; ii) the Mechanism Method; iii) the Finite Element Methods. The Thrust Line Analysis Method and the Mechanism Method are analytical methods and derived from two of the fundamental theorems of the Plastic Analysis, while the Finite Element Method is a numerical method, that uses different strategies of discretization to analyze the structure. Every method is applied to the case study through computer-based representations, that allow a friendly-use application of the principles explained. A particular closed-form approach based on an elasto-plastic material model and developed by some Belgian researchers is also studied. To compare the three methods, two different case study have been analyzed: i) a generic masonry arch bridge with a single span; ii) a real masonry arch bridge, the Clemente Bridge, built on Savio River in Cesena. In the analyses performed, all the models are two-dimensional in order to have results comparable between the different methods taken in exam. The different methods have been compared with each other in terms of collapse load and of hinge positions.
Resumo:
This thesis reports a study on the seismic response of two-dimensional squat elements and their effect on the behavior of building structures. Part A is devoted to the study of unreinforced masonry infills, while part B is focused on reinforced concrete sandwich walls. Part A begins with a comprehensive review of modelling techniques and code provisions for infilled frame structures. Then state-of-the practice techniques are applied for a real case to test the ability of actual modeling techniques to reproduce observed behaviors. The first developments towards a seismic-resistant masonry infill system are presented. Preliminary design recommendations for the seismic design of the seismic-resistant masonry infill are finally provided. Part B is focused on the seismic behavior of a specific reinforced concrete sandwich panel system. First, the results of in-plane psuudostatic cyclic tests are described. Refinements to the conventional modified compression field theory are introduced in order to better simulate the monotonic envelope of the cyclic response. The refinements deal with the constitutive model for the shotcrete in tension and the embedded bars. Then the hysteretic response of the panels is studied according to a continuum damage model. Damage state limits are identified. Design recommendations for the seismic design of the studied reinforced concrete sandwich walls are finally provided.
Resumo:
This paper presents the application of the Integral Masonry System (IMS) to the construction of earthquake resistant houses and its experimental study. To verify the security of this new type of building in seismic areas of the third world two prototypes have been tested, one with adobe and the other with hollow brick. In both cases it’s a two-story 6x6x6 m3 house built to scale 1/2. The tests are carried out at the Laboratory of Antiseismic Structures of the Department of Engineering, Pontifical Catholic University of Peru in Lima, in collaboration with the UPM (Technical University of Madrid). This article shows the design process of the prototypes to test, including the sizing of the reinforcements, the characteristics of the tests and the results obtained. These results show that the IMS with adobe or brick remains stable with no significant cracks faced with a severe earthquake, with an estimated acceleration of 1.8 g. Este artículo presenta una aplicación del Sistema de Albañilería Integral (SAI) a la construcción de viviendas sismorresistentes y su estudio experimental. Para verificar su seguridad para su construcción en zonas sísmicas del tercer mundo se han ensayado dos prototipos, uno con adobe, y otro con ladrillo hueco. Se trata de una vivienda de 6x6x6 m3 y dos plantas que se construyen a escala 1/2. Los ensayos se realizaron en el Laboratorio de Estructuras Antisísmicas del Departamento de Ingeniería de la Pontificia Católica Universidad del Perú (PUCP) de Lima en colaboración con la UPM (Universidad Politécnica de Madrid). Este artículo muestra el proceso de diseño de los prototipos a ensayar, incluido el dimensionado de los refuerzos, las características de los ensayos y los resultados obtenidos. Estos resultados muestran que el SAI con adobe o ladrillo permanece estable sin grietas significativas ante un sismo severo, con una aceleración estimada de 1,8 g.
Resumo:
A large number of reinforced concrete (RC) frame structures built in earthquake-prone areas such as Haiti are vulnerable to strong ground motions. Structures in developing countries need low-cost seismic retrofit solutions to reduce their vulnerability. This paper investigates the feasibility of using masonry infill walls to reduce deformations and damage caused by strong ground motions in brittle and weak RC frames designed only for gravity loads. A numerical experiment was conducted in which several idealized prototypes representing RC frame structures of school buildings damaged during the Port-au-Prince earthquake (Haiti, 2010) were strengthened by adding elements representing masonry infill walls arranged in different configurations. Each configuration was characterized by the ratio Rm of the area of walls in the direction of the ground motion (in plan) installed in each story to the total floor area. The numerical representations of these idealized RC frame structures with different values of Rm were (hypothetically) subjected to three major earthquakes with peak ground accelerations of approximately 0.5g. The results of the non-linear dynamic response analyses were summarized in tentative relationships between Rm and four parameters commonly used to characterize the seismic response of structures: interstory drift, Park and Ang indexes of damage, and total amount of energy dissipated by the main frame. It was found that Rm=4% is a reasonable minimum design value for seismic retrofitting purposes in cases in which available resources are not sufficient to afford conventional retrofit measures.
Resumo:
The effect of infill walls on the behaviour of frames is widely recognized, and, for several decades now, has been the subject of numerous experimental investigations. However, the analytical modeling of infilled panels and frames under in-plane loading is difficult and generally unreliable. From the point of view of the simulation technique the models may be divided into micromodels and simplified (or macro-) models. Based on the equivalent strut approach (simplified model), in this paper a damage model is proposed for the characterization of masonry walls submitted to lateral cyclic loads. The model, developed along the lines of the Continuum Damage Mechanics, have the advantages of including explicitly the coupling between damage and mechanical behaviour and so is consistent with the definition of damage as a phenomenon with mechanical consequences.
Resumo:
This paper presents a structural analysis of a masonry chimney built in the 1940s, which is currently being cataloged as local interest heritage. This structure has not served any industrial purpose for the last thirty years. The chimney is located in the town of Agost (Alicante - Spain) and directly exposed to the prevailing winds from the sea, as it is approximately 12 km away from the waterfront and there are not any significant barriers, which could protect the structure against the wind. There are longitudinal cracks and fissures all along the shaft because of the chimney’s geometrical characteristics, the effect of the masonry creep and especially the lack of maintenance. Moreover, there is also a permanent bending deformation in the upper 1/3 of the height due to the wind pressure. A numerical analysis for the static behavior against gravity and wind loads was performed using the structure’s current conditions after a detailed report of its geometry, its construction system and the cracking pattern. Afterwards, the dynamic behavior was studied, i.e. a seismic analysis using both response spectra and accelerograms in order to examine the structural stability. This work shows the pre-monitoring analysis before any experimental testing. Using the current results the future test conditions will be determined (e.g. number of sensors and monitoring point location, excitation systems, etc) prior to a possible structural reinforcement by applying composite material (fiber reinforced polymers).
Resumo:
"Prepared under the supervision of William A. Radford, editor-in-chief ... Alfred Sidney Johnson ... editor in charge."
Semi-engineered earthquake-resistant structures: one-storey buildings built up with gabion-box walls
Resumo:
This thesis studies the static and seismic behavior of simple structures made with gabion box walls. The analysis was performed considering a one-story building with standard dimensions in plan (6m x 5m) and a lightweight timber roof. The main focus of the present investigation is to find the principals aspects of the seismic behavior of a one story building made with gabion box walls, in order to prevent a failure due to seismic actions and in this way help to reduce the seismic risk of developing countries where this natural disaster have a significant intensity. Regarding the gabion box wall, it has been performed some calculations and analysis in order to understand the static and dynamic behavior. From the static point of view, it has been performed a verification of the normal stress computing the normal stress that arrives at the base of the gabion wall and the corresponding capacity of the ground. Moreover, regarding the seismic analysis, it has been studied the in-plane and out-of-plane behavior. The most critical aspect was discovered to be the out-of-plane behavior, for which have been developed models considering the “rigid- no tension model” for masonry, finding a kinematically admissible multiplier that will create a collapse mechanism for the structure. Furthermore, it has been performed a FEM and DEM models to find the maximum displacement at the center of the wall, maximum tension stresses needed for calculating the steel connectors for joining consecutive gabions and the dimensions (length of the wall and distance between orthogonal walls or buttresses) of a geometrical configuration for the standard modulus of the structure, in order to ensure an adequate safety margin for earthquakes with a PGA around 0.4-0.5g. Using the results obtained before, it has been created some rules of thumb, that have to be satisfy in order to ensure a good behavior of these structure.
Clustering of Protein Structures Using Hydrophobic Free Energy And Solvent Accessibility of Proteins