991 resultados para Marginal Adaptation (Dentistry)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: This systematic review aimed to report and explore the survival of dental veneers constructed from non-feldspathic porcelain over 5 and 10 years.

MATERIALS AND METHODS: A total of 4,294 articles were identified through a systematic search involving all databases in the Cochrane Library, MEDLINE (OVID), EMBASE, Web of Knowledge, specific journals (hand-search), conference proceedings, clinical trials registers, and collegiate contacts. Articles, abstracts, and gray literature were sought by two independent researchers. There were no language limitations. One hundred sixteen studies were identified for full-text assessment, with 10 included in the analysis (5 qualitative, 5 quantitative). Study characteristics and survival (Kaplan-Meier estimated cumulative survival and 95% confidence interval [CI]) were extracted or recalculated. A failed veneer was one which required an intervention that disrupted the original marginal integrity, had been partially or completely lost, or had lost retention more than twice. A meta-analysis and sensitivity analysis of Empress veneers was completed, with an assessment of statistical heterogeneity and publication bias. Clinical heterogeneity was explored for results of all veneering materials from included studies.

RESULTS: Within the 10 studies, veneers were fabricated with IPS Empress, IPS Empress 2, Cerinate, and Cerec computer-aided design/computer-assisted manufacture (CAD/CAM) materials VITA Mark I, VITA Mark II, Ivoclar ProCad. The meta-analysis showed the pooled estimate for Empress veneers to be 92.4% (95% CI: 89.8% to 95.0%) for 5-year survival and 66% to 94% (95% CI: 55% to 99%) for 10 years. Data regarding other non-feldspathic porcelain materials were lacking, with only a single study each reporting outcomes for Empress 2, Cerinate, and various Cerec porcelains over 5 years. The sensitivity analysis showed data from one study had an influencing and stabilizing effect on the 5-year pooled estimate.

CONCLUSION: The long-term outcome (> 5 years) of non-feldspathic porcelain veneers is sparsely reported in the literature. This systematic review indicates that the 5-year cumulative estimated survival for etchable non-feldspathic porcelain veneers is over 90%. Outcomes may prove clinically acceptable with time, but evidence remains lacking and the use of these materials for veneers remains experimental.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To evaluate the placement of composite materials by new graduates using three alternative placement techniques.Methods: A cohort of 34 recently qualified graduates were asked to restore class II interproximal cavities in plastic teeth using three different techniques.

(i) A conventional incremental filling technique (Herculite XRV) using increments no larger than 2-mm with an initial layer on the cervical floor of the box of 1-mm.
(ii) Flowable bulk fill technique (Dentsply SDR) bulk fill placement in a 3-mm layer followed by an incremental fill of a microhybrid resin
(iii) Bulk fill (Kerr Sonicfill) which involved restorations placed in a 5-mm layer.

The operators were instructed in each technique, didactically and with a hands-on demonstration, prior to restoration placement.
All restorations were cured according to manufacturer’s recommendations. Each participant restored 3 teeth, 1 tooth per treatment technique.
The restorations were evaluated using modified USPHS criteria to assess both the marginal adaptation and the surface texture of the restorations. Blind evaluations were carried out independently by two examiners with the aid of magnification (loupes X2.5). Examiners were standardized prior to evaluation.
Results: Gaps between the tooth margins and the restoration or between the layers of the restoration were found in 13 of Group (i), 3 of Group (ii), and 4 of Group (iii)
Statistical analysis revealed a significant difference between the incrementally filled group (i) and the flowable bulk-fill group (ii) (p=0.0043) and between the incrementally filled (i) and the bulk fill groups (iii) (p=0.012) and no statistical difference (p=0.69) between the bulk filled groups Conclusions: Bulk fill techniques may result in a more satisfactory seal of the cavity margins when restoring with composite.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to clinically evaluate fluoride-containing sealants in teeth subjected to minimal enamel reduction (preventive resin restorations). Two hundred fourteen sealants (109 Fluro Shield and 105 Delton Fluor) were applied in 153 teeth of 32 subjects. The sealants were evaluated for superficial irregularities, marginal adaptation, retention, and caries after 6, 12, 18, and 24 months. After 6, 12, and 18 months, the attendance at recall was 100.00%. After 24 months, 93.75% of subjects returned for reevaluation. Although total or partial loss of sealant occurred in a few instances, no occlusal caries was found in any tooth at any recall. No statistically significant differences in the results of the clinical evaluation were found between sealant in the maxillary and mandibular dentitions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim : To compare the push-out strength of bovine- and human-root dentin and, thus, evaluate the suitability of bovine-root dentin to substitute human-root dentin for bond strength testing. Materials and Methods : Ten single-rooted human-teeth and ten bovine incisors were prepared using a #3 bur of a fiber post system (12 mm long). The posts were duplicated with resin cement (Duolink). The root canals were treated with All Bond 2 adhesive system and the resin posts were cemented using Duolink. The specimens were cut perpendicular to their long axis, yielding disc-specimens with 1.5 mm thickness, which were submitted to a push-out test (1 mm/min). Ten bond strength values per group (n = 10) were used for statistical analysis (Student t test, a =.05). Results : Statistically significant differences were found for the bond strength values between bovine- (4.1 1.3 MPa) and human-root dentin (8.6 5.7 MPa) (P =.0001). Conclusion : The push-out strengths of bovine- and human-root dentin were statistically different.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To analyze the reasons for replacing amalgam and composite resin restorations of patients treated at the Integrated Clinic Discipline of the Dental School of Araçatuba (UNESP), SP, Brazil. Method: After examining the patients for data collection to obtain a diagnosis, the treatment plan was outlined using a clinical form containing the restorations to be replaced, the reasons for replacing, the restorative material of choice and the number of restored surfaces. Next, all restorations indicated for replacement were examined as to their real need of replacement by 5 calibrated examiners taking into account the theorical concepts on the proposed criteria for the need of replacing or not. The analyzed period comprised 5 years (2001 to 2005). The criteria adopted for replacement were attached to the data collecting form in order to standardize the analysis of the restorations. Results: 856 patients were treated within the studied period and 753 needed restoration replacement. The main reasons for replacing amalgam restorations were defective marginal adaptation (40.9%), recurent caries (24.1%) and deficient anatomical form (15.4%). The main reasons for replacing resin restorations were esthetics (31.4%), defective marginal adaptation (29.2%) and recurent caries (20.7%). Conclusion: In spite of the little clinical experience of the studied population (undergraduate students), the reasons for replacing restorations were in accordance with the literature, having estehtics as the main reason for the replacement of composite resin restorations and defective marginal adaptation for amalgam restorations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)-100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated the dimensional alterations and the solubility of two experimental endodontic sealers based on Copaifera multijuga oil-resin (Biosealer) and castor oil bean cement (Poliquil), maintained in different storage solutions. Twenty specimens (3 mm diameter and 2 mm height) of each sealer were assigned to 2 groups (n=10) according to the storage solution: simulated tissue fluid (STF) or distilled water (DW). The specimens were stored in these solutions during 90 days, being removed every 30 days for weighting. The solutions were renewed every 15 days. The results were subjected to statistical analysis by Dunn's and Mann-Whitney tests (α=0.05). The solubility of Poliquil was higher in STF (38.4 ± 36.0) than in DW (28.4 ± 15.0), while Biosealer showed higher solubility in DW (34.61 ± 6.0) than in STF (18.59 ± 8.0). The storage solution influenced the behavior of sealers in relation to the weight variation (p=0.0001). Poliquil presented higher variation of weight independent of the solution (p=0.239). Biosealer also presented higher variation of weight regardless of the solution (p=0.0001). The solubility of Biosealer was different from that of Poliquil, but both sealers showed low solubility in STF. Under the tested conditions, neither of the materials were according to the ADA'S specification.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste ensaio clínico randomizado foi avaliar o comportamento clínico das restaurações adesivas, usando um adesivo convencional de três passos (CTP), um adesivo autocondicionante de um passo (AUP) e uma técnica simplificada da adesão úmida por etanol (AUET) antes da aplicação de uma resina composta em lesões cervicais não-cariosas. Noventa e três restaurações (31 para cada grupo) foram realizadas em 17 pacientes por um único operador. Nenhum preparo cavitário foi realizado. Depois de 6 e 12 meses, as restaurações foram avaliadas por 2 examinadores previamente treinados, utilizando critérios de Ryge modificados para retenção (kappa=1,00) e adaptação/manchamento marginal (kappa=0,81), e os resultados foram analisados pelos testes Exato de Fisher e Kruskal-Wallis, respectivamente. Não foram observadas diferenças significativas entre os grupos aos 6 e 12 meses para qualquer um dos critérios avaliados (p≥0,05). A análise intra-grupo feita pelos testes Q de Cochran (para retenção) e Wilcoxon (para adaptação/manchamento marginal) revelou diferenças significativas entre os intervalos de tempo baseline/12 meses para a adaptação marginal no AUP (p=0,0180) e manchamento marginal no CTP (p=0,0117). A análise de sobrevivência para o critério retenção realizada utilizando o teste de log-rank não apresentou diferenças significantes (p≥0,05). As restaurações feitas utilizando a técnica simplificada da adesão úmida por etanol comportaram-se igualmente às outras estratégias adesivas empregadas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper evaluates the photopolymerization kinetics and degree of conversion of different commercial dental composites when photoactivated by a LED curing unit using two different modes (standard and soft-start mode). The investigation was performed on with RelyX ARC (dual-cured), Filtek Z-350 (Nanocomposite), Filtek Z-250 (Hybrid), and Filtek Z-350flow (Flowable) resin composites. The analysis used was attenuated total reflection with a Fourier transform infrared (ATR-FTIR). The RelyX ARC resin demonstrated the highest degree of conversion with both LED photoactivation modes. For this resin a 28% decrease in maximum rate was observed and the time to reach its highest rate was almost 2.3 times higher than when the soft-start photoactivation light curing was used. Z-350flow resin recorder a higher maximum rate using the soft-start mode rather than the standard mode. In contrast, the Z-250 showed a higher value using the standard mode. Although Z-250 and Z-350 showed a higher total degree of conversion effectiveness using the soft-start mode, RelyX and Z-350flow achieved a higher value using the standard mode.