960 resultados para Manifest refractive cylinder


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Accommodation to overcome hypermetropia is implicated in emmetropisation. This study recorded accommodation responses in a wide range of emmetropising infants and older children with clinically significant hypermetropia to assess common characteristics and differences. Methods: A PlusoptiXSO4 photorefractor in a laboratory setting was used to collect binocular accommodation data from participants viewing a detailed picture target moving between 33cm and 2m. 38 typically developing infants were studied between 6-26 weeks of age and were compared with cross-sectional data from children 5-9 years of age with clinically significant hypermetropia (n=15), corrected fully accommodative strabismus (n=14) and 27 age-matched controls. Results: Hypermetropes of all ages under-accommodated compared to controls at all distances, whether corrected or not (p<0.00001) and lag related to manifest refraction. Emmetropising infants under-accommodated most in the distance, while the hypermetropic patient groups underaccommodated most for near. Conclusions: Better accommodation for near than distance is demonstrated in those hypermetropic children who go on to emmetropise. This supports the approach of avoiding refractive correction in such children. In contrast, hypermetropic children referred for treatment for reduced distance visual acuity are not likely to habitually accommodate to overcome residual hypermetropia left by an under-correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two styrene-isoprene-styrene block copolymers Vector 4111 and 4113, exhibiting cylindrical (18 wt % PS) and spherical (16 wt % PS) morphology, respectively, have been examined under uniaxial elongation up to 200% strain. On the basis of stress-strain data, mechanical properties are compared for isotropic and oriented polystyrene domains. The structure at various stages of deformation has been determined from SAXS patterns in three planes and two principal deformation directions with respect to orientation. Samples showed a very high degree of hexagonal packing, resulting in an X-ray pattern taken parallel to the cylinder alignment approaching single crystal ordering. Cylinders were aligned with the closest packed planes parallel to film surface. Particular attention has been paid to a lattice deformation process occurring during the first stretching and relaxation cycle. For a copolymer with oriented cylindrical morphology the deformation was affine up to 120% strain. The microdomain spacing was calculated parallel and perpendicular to the stretching direction. The cylindrical microstructure orientation, quantified by Hermans' orientation factor reduced during elongation of oriented polymer, while the elongation of isotropic sample caused an increase of orientation. Deformation of all studied morphologies was reversible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanisms of refractive index change in poly(methyl methacrylate) by frequency doubled femtosecond laser pulses are investigated. It is demonstrated that positive refractive index modificaton can be caused by a combination of depolymerization and crosslinking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Z-scan technique is employed to obtain the nonlinear refractive index (n (2)) of the Ca(4)REO(BO(3))(3) (RECOB, where RE = Gd and La) single crystals using 30 fs laser pulses centered at 780 nm for the two orthogonal orientations determined by the optical axes (X and Z) relative to the direction of propagation of the laser beam (k//Y// crystallographic b-axis). The large values of n (2) indicate that both GdCOB and LaCOB are potential hosts for Yb:RECOB lasers operating in the Kerr-lens mode locking (KLM) regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation of an optical beam through dielectric media induces changes in the refractive index, An, which causes self-focusing or self-defocusing. In the particular case of ion-doped solids, there are thermal and non-thermal lens effects, where the latter is due to the polarizability difference, Delta alpha, between the excited and ground states, the so-called population lens (PL) effect. PL is a pure electronic contribution to the nonlinearity, while the thermal lens (TL) effect is caused by the conversion of part of the absorbed energy into heat. In time-resolved measurements such as Z-scan and TL transient experiments, it is not easy to separate these two contributions to nonlinear refractive index because they usually have similar response times. In this work, we performed time-resolved measurements using both Z-scan and mode mismatched TL in order to discriminate thermal and electronic contributions to the laser-induced refractive index change of the Nd3+-doped Strontium Barium Niobate (SrxBa1-xNb2O6) laser crystal. Combining numerical simulations with experimental results we could successfully distinguish between the two contributions to An. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a laboratory for loop quantum gravity, we consider the canonical quantization of the three-dimensional Chern-Simons theory on a noncompact space with the topology of a cylinder. Working within the loop quantization formalism, we define at the quantum level the constraints appearing in the canonical approach and completely solve them, thus constructing a gauge and diffeomorphism invariant physical Hilbert space for the theory. This space turns out to be infinite dimensional, but separable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Surveillance is a central activity among mental health nursing, but it is also questioned for its therapeutic value and considered to be custodial. Aim. The aim of this study was to describe how mental health nurses use different approaches to observe patients in relation to the practice of surveillance in psychiatric nursing care. Methods. In this study, Spradley's twelve-step ethnographic method was used. Results. Mental health nurses use their cultural knowing to observe patients in psychiatric care in various ways. Two dichotomous approaches were identified: the latent and the manifest approach. Discussion. Different strategies and techniques for observing patients are structured along two dichotomies. The underlying relationships between these two different dichotomous positions transform the act of observing into surveillance. This is further developed in a theoretical model called the powerful scheme of observation and surveillance (PSOS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Starting from the analysis of a Manifest placed in the World Wide Web in order to gather signatures, the paper discusses the arousal of a wide spread movement of scepticism in the so called Portuguese “civil socie ty” against the overall result of almost forty years of uninterrupted educational reform that has taken place in Portugal since the late sixties and has lead to an increasing percentage of illiteracy and innumeracy. That Manifest is presented as part of a broader movement, deeply rooted in the Portuguese society, and silent so far, which is becoming stronger and has now strength enough to be part of the political agenda. It is also our concern to unveil an emerging trend of blaming sciences of education and badly trained teachers as responsible for the poor outcome of our schooling system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the prevalence of refractive errors in the public and private school system in the city of Natal, Northeastern Brazil. Methods: Refractometry was performed on both eyes of 1,024 randomly selected students, enrolled in the 2001 school year and the data were evaluated by the SPSS Data Editor 10.0. Ametropia was divided into: 1- from 0.1 to 0.99 diopter (D); 2- 1.0 to 2.99D; 3- 3.00 to 5.99D and 4- 6D or greater. Astigmatism was regrouped in: I- with-the-rule (axis from 0 to 30 and 150 to 180 degrees), II- against-the-rule (axis between 60 and 120 degrees) and III- oblique (axis between > 30 and < 60 and >120 and <150 degrees). The age groups were categorized as follows, in: 1- 5 to 10 years, 2- 11 to 15 years, 3- 16 to 20 years, 4- over 21 years. Results: Among refractive errors, hyperopia was the most common with 71%, followed by astigmatism (34%) and myopia (13.3%). Of the students with myopia and hyperopia, 48.5% and 34.1% had astigmatism, respectively. With respect to diopters, 58.1% of myopic students were in group 1, and 39% distributed between groups 2 and 3. Hyperopia were mostly found in group 1 (61.7%) as well as astigmatism (70.6%). The association of the astigmatism axes of both eyes showed 92.5% with axis with-the-rule in both eyes, while the percentage for those with axis againstthe- rule was 82.1% and even lower for the oblique axis (50%). Conclusion: The results found differed from those of most international studies, mainly from the Orient, which pointed to myopia as the most common refractive error, and corroborates the national ones, with the majority being hyperopia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hybrid formalism for the superstring is used to compute one-loop amplitudes with an arbitrary number of external d = 4 supergravity states. These one-loop N-point amplitudes are expressed as Koba-Nielsen-like formulas with manifest d = 4 supersymmetry. (C) 2002 Published by Elsevier B.V. B.V.