908 resultados para MINIMALLY INVASIVE SURGERY
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Selective neck dissection (SND) in clinical N-0 (cN(0)) cases of oral squamous cell carcinoma (SCC) has been performed by surgeons using a retroauricular or modified facelift approach with robotic or endoscopic assistance. However, these procedures provide cosmetic satisfaction at the cost of possible maximal invasiveness. In this prospective study, we introduced and evaluated the feasibility as well as surgical invasiveness and cosmetic outcome of endoscopically-assisted SND via a small submandibular approach.Forty-four patients with cT(1-2)N(0) oral SCC (OSCC) were randomly divided into two groups of endoscopically-assisted SND and conventional SND. Perioperative and postoperative outcomes of patients were evaluated, including the length of the incision, operating time for neck dissection, estimated blood loss during the operation, amount and duration of drainage, total hospitalization period, total number of lymph nodes retrieved, satisfaction scores based on the cosmetic results, perioperative local complications, shoulder syndrome, and follow-up information.The mean operation time in the endoscopically-assisted group (126.04 +/- A 12.67 min) was longer than that in the conventional group (75.67 +/- A 16.67 min). However, the mean length of the incision was 4.33 +/- A 0.76 cm in the endoscopically-assisted SND group, and the amount and duration of drainage, total hospital stay, postoperative shoulder pain score, and cosmetic outcomes were superior in the endoscopically-assisted SND group. Additionally, the retrieved lymph nodes and complications were comparable.Endoscopically-assisted SND via a small submandibular approach had a longer operation time than the conventional approach. However, endoscopically-assisted SND was feasible and reliable while providing minimal invasiveness and satisfactory appearance.
Resumo:
The ability to integrate multiple materials into miniaturized fiber structures enables the realization of novel biomedical textile devices with higher-level functionalities and minimally-invasive attributes. In this work, we present novel textile fabrics integrating unobtrusive multi-material fibers that communicate through 2.4 GHz wireless networks with excellent signal quality. The conductor elements of the textiles are embedded within the fibers themselves, providing electrical and chemical shielding against the environment, while preserving the mechanical and cosmetic properties of the garments. These multi-material fibers combine insulating and conducting materials into a well-defined geometry, and represent a cost-effective and minimally-invasive approach to sensor fabrics and bio-sensing textiles connected in real time to mobile communications infrastructures, suitable for a variety of health and life science applications.
Resumo:
Isoflurane is a volatile halogenated anesthetic used especially for anesthesia maintenance whereas propofol is a venous anesthetic utilized for anesthesia induction and maintenance, and reportedly an antioxidant. However, there are still controversies related to isoflurane-induced oxidative stress and it remains unanswered whether the antioxidant effects occur in patients under propofol anesthesia.Taking into account the importance of better understanding the role of anesthetics on oxidative stress in anesthetized patients, the present study was designed to evaluate general anesthesia maintained with isoflurane or propofol on antioxidant status in patients who underwent minimally invasive surgeries.We conducted a prospective randomized trial in 30 adult patients without comorbidities who underwent elective minor surgery (septoplasty) lasting at least 2 h admitted to a Brazilian tertiary hospital.The patients were randomly allocated into 2 groups, according to anesthesia maintenance (isoflurane, n = 15 or propofol, n = 15). Peripheral blood samples were drawn before anesthesia (baseline) and 2-h after anesthesia induction.The primary outcomes were to investigate the effect of either isoflurane or propofol anesthesia on aqueous plasma oxidizability and total antioxidant performance (TAP) by fluorometry as well as several individual antioxidants by high-performance liquid chromatography. As secondary outcome, oxidized genetic damage (7,8-dihydro-8-oxoguanine, known as 8-oxo-Gua) was investigated by the comet assay.Both anesthesia techniques (isoflurane or propofol) for a 2-h period resulted in a significant decrease of plasma α-tocopherol, but not other antioxidants including uric acid, carotenoids, and retinol (P > 0.05). Propofol, in contrast to isoflurane anesthesia, significantly increased (P < 0.001) anti-inflammatory/antioxidant plasma γ-tocopherol concentration in patients. Both anesthesia types significantly enhanced hydrophilic antioxidant capacity and TAP, with no significant difference between them, and 8-oxo-Gua remained unchanged during anesthesia in both groups. In addition, both anesthetics showed antioxidant capacity in vitro.This study shows that anesthesia maintained with either propofol or isoflurane increase both hydrophilic and total antioxidant capacity in plasma, but only propofol anesthesia increases plasma γ-tocopherol concentration. Additionally, both types of anesthetics do not lead to oxidative DNA damage in patients without comorbidities undergoing minimally invasive surgery.
Resumo:
Background: Women with a family history of breast cancer who develop this disease are confronted with important situations regarding the increased risk for development of a second cancer in the contralateral breast. Prophylactic contralateral mastectomy (PCM) reduces by approximately 95% the risk for contralateral breast cancer. In spite of an increase in indications for PCM, the technical difficulties are many regarding the accomplishment of these procedures. The aim of this study is to describe the technique of mastectomy with preservation of the nipple-areola complex and a small incision, reducing surgical difficulties and complications attributed to this technique, thus allowing better aesthetic results in breast reconstruction. Methods: Forty-six patients with indications for PCM (28 bilateral) were submitted to minimally invasive mastectomy from March 2005 to November 2007. A small incision in the superior pole of the areola, sufficient to pass a liposuction 4 mm cannula is made. With the help of this cannula, detachment of the skin from the gland tissue is performed. Then a 3.5 to 4.5-cm long incision in the inframammary fold is made. Glandular detachment is completed using cautery in the sub,glandular portion and scissors in the upper breast portion cutting the restraints left by the cannula. The mammary gland tissue is removed through this incision. Results: Seventy-four breasts were operated on. The resected breast mass ranged from 285 g to 475 g. All 43 patients were reconstructed with prostheses. There was no necrosis of the nipple-areola complex or of the skin. Conclusions: This technique is an option for cases of patients with indications for PCM.
Resumo:
A Micro-opto-mechanical systems (MOMS) based technology for the fabrication of ultrasonic probes on optical fiber is presented. Thanks to the high miniaturization level reached, the realization of an ultrasonic system constituted by ultrasonic generating and detecting elements, suitable for minimally invasive applications or Non Destructive Evaluation (NDE) of materials at high resolution, is demonstrated. The ultrasonic generation is realized by irradiating a highly absorbing carbon film patterned on silicon micromachined structures with a nanosecond pulsed laser source, generating a mechanical shock wave due to the thermal expansion of the film induced by optical energy conversion into heat. The short duration of the pulsed laser, together with an appropriate emitter design, assure high frequency and wide band ultrasonic generation. The acoustic detection is also realized on a MOMS device using an interferometric receiver, fabricated with a Fabry-Perot optical cavity realized by means of a patterned SU-8 and two Al metallization levels. In order to detect the ultrasonic waves, the cavity is interrogated by a laser beam measuring the reflected power with a photodiode. Various issues related to the design and fabrication of these acoustic probes are investigated in this thesis. First, theoretical models are developed to characterize the opto-acoustic behavior of the devices and estimate their expected acoustic performances. Tests structures are realized to derive the relevant physical parameters of the materials constituting the MOMS devices and determine the conditions theoretically assuring the best acoustic emission and detection performances. Moreover, by exploiting the models and the theoretical results, prototypes of acoustic probes are designed and their fabrication process developed by means of an extended experimental activity.
Resumo:
Non-contrast post-mortem computed tomography (pm-CT) is useful in the evaluation of bony pathologies, whereas minimally invasive pm-CT-angiography allows for the detection of subtle vascular lesions. We present a case of an accidentally self-inflicted fatal bullet wound to the chest where pm-CT-angiography revealed a small laceration of the anterior interventricular branch of the left coronary artery and a tiny disruption of the right ventricle with pericardial and pleural effusion. Subsequent autopsy confirmed our radiological findings. Post-mortem CT-angiography has a great potential for the detection of vascular lesions and can be considered equivalent to autopsy for selected cases in forensic medicine.
Resumo:
We report a case of a 78-year-old female with a proximal femur fracture caused by an accidental fall who died suddenly 1h after orthopaedic prosthesis insertion. Post-mortem computed tomography (CT) scan and histological examination of samples obtained with post-mortem percutaneous needle biopsies of both lungs were performed. Analysis of the medical history and the clinical scenario immediately before death, imaging data, and biopsy histology established the cause of death without proceeding to traditional autopsy. It was determined to be acute right ventricular failure caused by massive pulmonary fat embolism. Although further research in post-mortem imaging and post-mortem tissue sampling by needle biopsies is necessary, we conclude that the use of CT techniques and percutaneous biopsy, as additional tools, can offer a viable alternative to traditional autopsy in selected cases and may increase the number of minimally invasive forensic examinations performed in the future.
Resumo:
To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.
Resumo:
Although postmortem CT suffices for diagnosing most forms of traumatic death, the examination of natural death is, to date, very difficult and error prone. The introduction of postmortem angiography has led to improved radiologic diagnoses of natural deaths. Nevertheless, histologic changes to tissues, an important aspect in traditional examination procedures, remain obscure even with CT and CT angiography. For this reason, we examined the accuracy of a minimally invasive procedure (i.e., CT angiography combined with biopsy) in diagnosing major findings and the cause of death in natural deaths.
Resumo:
Microneurography is a method suitable for recording intraneural single or multiunit action potentials in conscious subjects. Microneurography has rarely been applied to animal experiments, where more invasive methods, like the teased fiber recording technique, are widely used. We have tested the feasibility of microneurographic recordings from the peripheral nerves of rats. Tungsten microelectrodes were inserted into the sciatic nerve at mid-thigh level. Single or multiunit action potentials evoked by regular electrical stimulation were recorded, digitized and displayed as a raster plot of latencies. The method allows unambiguous recording and recognition of single C-fiber action potentials from an in vivo preparation, with minimal disruption of the nerve being recorded. Multiple C-fibers can be recorded simultaneously for several hours, and if the animal is allowed to recover, repeated recording sessions can be obtained from the same nerve at the same level over a period of weeks or months. Also, single C units can be functionally identified by their changes in latency to natural stimuli, and insensitive units can be recognized as 'silent' nociceptors or sympathetic efferents by their distinctive profiles of activity-dependent slowing during repetitive electrical stimulation, or by the effect on spontaneous efferent activity of a proximal anesthetic block. Moreover, information about the biophysical properties of C axons can be obtained from their latency recovery cycles. Finally, we show that this preparation is potentially suitable for the study of C-fiber behavior in models of neuropathies and nerve lesions, both under resting conditions and in response to drug administration.
Resumo:
We investigated the feasibility of postmortem percutaneous needle biopsy (PNB) for obtaining pulmonary samples adequate for the study of pulmonary fat embolism (PFE). Samples of both lungs were obtained from 26 cadavers via two different methods: (i) PNB and (ii) the double-edged knife technique, the gold standard at our institute. After water storage and Sudan III staining, six forensic pathologists independently examined all samples for the presence and severity of PFE. The results were compared and analyzed in each case regarding the vitality of the PFE and its relationship to the cause of death. The results showed that PFE was almost identically diagnosed and graded on the samples obtained via both methods. The discrepancies between the two techniques did not affect the diagnoses of vitality or cause of death related to PFE. This study demonstrates the feasibility of the PNB sampling method for the diagnosis and interpretation of PFE in the postmortem setting.