880 resultados para Lower limbs power
Resumo:
Transmit antenna selection (AS) has been adopted in contemporary wideband wireless standards such as Long Term Evolution (LTE). We analyze a comprehensive new model for AS that captures several key features about its operation in wideband orthogonal frequency division multiple access (OFDMA) systems. These include the use of channel-aware frequency-domain scheduling (FDS) in conjunction with AS, the hardware constraint that a user must transmit using the same antenna over all its assigned subcarriers, and the scheduling constraint that the subcarriers assigned to a user must be contiguous. The model also captures the novel dual pilot training scheme that is used in LTE, in which a coarse system bandwidth-wide sounding reference signal is used to acquire relatively noisy channel state information (CSI) for AS and FDS, and a dense narrow-band demodulation reference signal is used to acquire accurate CSI for data demodulation. We analyze the symbol error probability when AS is done in conjunction with the channel-unaware, but fair, round-robin scheduling and with channel-aware greedy FDS. Our results quantify how effective joint AS-FDS is in dispersive environments, the interactions between the above features, and the ability of the user to lower SRS power with minimal performance degradation.
Resumo:
Modern pulse-width-modulated (PWM) rectifiers use LC L filters that can be applied in both the common mode and differential mode to obtain high-performance filtering. Interaction between the passive L and C components in the filter leads to resonance oscillations. These oscillations need to be damped either by the passive damping or active damping. The passive damping increases power loss and can reduce the effectiveness of the filter. Methods of active damping, using control strategy, are lossless while maintaining the effectiveness of the filters. In this paper, an active damping strategy is proposed to damp the oscillations in both line-to-line and line-to-ground. An approach based on pole placement by the state feedback is used to actively damp both the differential-and common-mode filter oscillations. Analytical expressions for the state-feedback controller gains are derived for both continuous and discrete-time model of the filter. Tradeoff in selection of the active damping gain on the lower order power converter harmonics is analyzed using a weighted admittance function. Experimental results on a 10-kVA laboratory prototype PWM rectifier are presented. The results validate the effectiveness of the active damping method, and the tradeoff in the settings of the damping gain.
Resumo:
The photoresponse of the graphene photodetector elucidated strong dependence on several optical parameters, such as the angle of incidence and the incident power of infrared exposure at room temperature. The sinusoidal dependence of the photoresponse on incidence angle, which had not been realized before, has now been revealed. The combined effect of the photo excited charge carrier and the photon drag effect explain this nonlinear optical absorption in graphene at lower incident power. The nonlinear dependence of the charge carrier generation on the incident power revealed that this process contributed to the nonlinear photoresponse. However, a deviation is observed at a higher incident power due to the induction of thermal effects in the graphene lattice. This work demonstrates the tunability of the graphene photodetector under a systematic variation that involves both parameters.
Resumo:
Lead-carbon hybrid ultracapacitors comprise positive lead dioxide plates of the lead-acid battery and negative plates of carbon-based electrical double-layer capacitors (EDLCs). Accordingly, a lead-carbon hybrid ultracapacitor has the features of both the battery and that of an EDLC. In this study, the development and performance comparison between the two types of lead-carbon hybrid ultracapacitors, namely those with substrate-integrated and conventional pasted positive plates, is presented as such a study is lacking in the literature. The study suggests that the faradaic efficiencies for both types of lead-carbon hybrid ultracapacitors are comparable. However, their capacitance values as well as energy and power densities differ significantly. For substrate-integrated positive plate hybrid ultracapacitor, capacitance and energy density values are lower, but power density values are higher than pasted positive plate lead-carbon hybrid ultracapacitors due to their shorter response time. Accordingly, internal resistance values are also lower for substrate-integrated lead-carbon hybrid ultracapacitors. Both types of lead-carbon hybrid ultracapacitors exhibit good cycle life of 100,000 pulse charge-discharge cycles with only a nominal loss in their capacitance values.
Resumo:
Functional Electrical Stimulation (FES) is a technique that consists on applying electrical current pulses to artificially activate motor nerve fibers and produce muscle contractions to achieve functional movements. The main applications of FES are within the rehabilitation field, in which this technique is used to aid recovery or to restore lost motor functions. People that benefit of FES are usually patients with neurological disorders which result in motor dysfunctions; most common patients include stroke and spinal cord injury (SCI). Neuroprosthesis are devices that have their basis in FES technique, and their aim is to bridge interrupted or damaged neural paths between the brain and upper or lower limbs. One of the aims of neuroprosthesis is to artificially generate muscle contractions that produce functional movements, and therefore, assist impaired people by making them able to perform activities of daily living (ADL). FES applies current pulses and stimulates nerve fibers by means of electrodes, which can be either implanted or surface electrodes. Both of them have advantages and disadvantages. Implanted electrodes need open surgery to place them next to the nerve root, so these electrodes carry many disadvantages that are produced by the use of invasive techniques. In return, as the electrodes are attached to the nerve, they make it easier to achieve selective functional movements. On the contrary, surface electrodes are not invasive and are easily attached or detached on the skin. Main disadvantages of surface electrodes are the difficulty of selectively stimulating nerve fibers and uncomfortable feeling perceived by users due to sensory nerves located in the skin. Electrical stimulation surface electrode technology has improved significantly through the years and recently, multi-field electrodes have been suggested. This multi-field or matrix electrode approach brings many advantages to FES; among them it is the possibility of easily applying different stimulation methods and techniques. The main goal of this thesis is therefore, to test two stimulation methods, which are asynchronous and synchronous stimulation, in the upper limb with multi-field electrodes. To this end, a purpose-built wrist torque measuring system and a graphic user interface were developed to measure wrist torque produced with each of the methods and to efficiently carry out the experiments. Then, both methods were tested on 15 healthy subjects and sensitivity results were analyzed for different cases. Results show that there are significant differences between methods regarding sensation in some cases, which can affect effectiveness or success of FES.
Resumo:
166 p.
Resumo:
Indivíduos que permanecem longo tempo em cadeira de rodas apresentam importante perda de massa óssea, principalmente nos membros inferiores, possivelmente agravada pela baixa ingestão de cálcio dietético e pelo inadequado estado nutricional de vitamina D. O exercício físico pode contribuir para a manutenção ou aumento da massa óssea em diferentes populações e nos indivíduos com lesão medular pode contribuir para atenuar a perda de massa óssea. O objetivo do presente estudo foi avaliar a influência da prática regular de exercício físico sobre a adequação da massa óssea, indicadores bioquímicos do metabolismo ósseo e estado nutricional de vitamina D em indivíduos com lesão medular cervical há pelo menos um ano. Em vinte e cinco homens de 19 a 56 anos sendo 15 fisicamente ativos e 10 sedentários, foi realizada análise sérica de cálcio, PTH, 25(OH)D, IGF-1, osteocalcina e NTx. As medidas do conteúdo mineral ósseo, densidade mineral óssea (DMO), massa magra e massa gorda foram realizadas por DXA. A pigmentação da pele (constitutiva e por bronzeamento) foi determinada por colorimetria com o objetivo de investigar sua influência sobre o estado de vitamina D. A ingestão habitual de cálcio foi registrada em um questionário de frequência alimentar direcionado para alimentos fonte. As comparações entre os dois grupos foram realizadas pela aplicação do Teste t de Student exceto para as variáveis ósseas que foram realizadas após ajustes pela massa corporal total, tempo de lesão e ingestão de cálcio utilizando-se análise de co-variância. Associações entre as variáveis estudadas foram avaliadas através de análise de correlação de Pearson. Valores de p<0.05 foram considerados significativos. Não foram observadas diferenças estatisticamente significativas entre os grupos para nenhuma variável óssea com exceção do z-score da DMO da coluna lombar, que foi significativamente maior no grupo de indivíduos sedentários (0,9 1,7 vs -0,7 0,8; p<0,05). No entanto, entre os indivíduos ativos, aqueles que iniciaram a prática de exercício físico com menos tempo decorrido após a lesão apresentaram maior DMO do fêmur (r=-0,60; p<0,05). Nos indivíduos ativos, a freqüência do exercício apresentou associação negativa com a concentração sérica de i-PTH (r = -0,50; p =0,05) e positiva com a concentração de 25(OH)D (r= 0,58; p <0,05). Após ajustes pela massa corporal total e tempo de lesão foram observadas associações positivas entre a ingestão diária de cálcio e z-score da DMO da coluna lombar (r = 0,73 e p <0,01) e DMO do rádio (r = 0,56 e p <0,05). Os resultados do presente estudo apontam para um efeito benéfico do exercício físico sobre a massa óssea e o perfil hormonal relacionado ao metabolismo ósseo. O início da prática regular de exercício físico o quanto antes após a lesão parece contribuir para atenuar a perda de massa óssea nos membros inferiores. Além disso, os resultados deste estudo sugerem uma possível potencialização do efeito osteogênico do exercício físico quando combinado a uma adequada ingestão de cálcio.
Resumo:
In this study, aspects of the structural mechanics of the upper and lower limbs of the three Chinese species of Rhinopithecus were examined. Linear regression and reduced major axis (RMA) analyses of natural log-transformed data were used to examine the dimensions of limb bones and other relationships to body size and locomotion. The results of this study suggest that: (1) the allometry exponents of the lengths of long limbs deviate from isometry, being moderately negative, while the shaft diameters (both sagittal and transverse) show significantly positive allometry; (2) the sagittal diameters of the tibia and ulna show extremely significantly positive allometry - the relative enlargement of the sagittal, as opposed to transverse, diameters of these bones suggests that the distal segments of the fore- and hindlimbs of Rhinopithecus experience high bending stresses during locomotion; (3) observations of Rhinopithecus species in the field indicate that all species engage in energetic leaping during arboreal locomotion. The limbs experience rapid and dramatic decelerations upon completion of a leap. We suggest that these occasional decelerations produce high bending stresses in the distal limb segments and so account for the hypertrophy of the sagittal diameters of the ulna and tibia.
Resumo:
A study on the nanosecond fiber laser interaction with silicon was performed experimentally for the generation of percussion drilled holes. Single pulse ablation experiments were carried out on mono crystalline 650μm thick Si wafers. Changes of the mass removal mechanism were investigated by varying laser fluence up to 68 J/cm2 and pulse duration from 50 ns to 200 ns. Hole width and depth were measured and surface morphology were studied using scanning electron microscopy (SEM) and optical interferometric profilometry (Veeco NT3300). High speed photography was also used to examine laser generated plasma expansion rates. The material removal rate was found to be influenced by the pulse energy, full pulse duration and pulse peak power. Single pulse ablation depth of 4.42 μm was achieved using a 200 ns pulse of 13.3 J/cm 2, giving a maximum machining efficiency of 31.86 μm per mJ. Holes drilled with an increased fluence but fixed pulse length were deeper, exhibited low recast, but were less efficient than those produced at a lower fluence. The increased peak power in this case led to high levels of plasma and vapour production. The expansion of which, results in a strong driving recoil force, an increase in the rate and volume of melt ejection, and cleaner hole formation. The experimental findings show that for efficient drilling at a given energy, a longer, lower peak power pulse is more desirable than a high peak power short pulse.
Resumo:
The Accelerator Driven Subcritical Reactor (ADSR) concept is based on the coupling of a particle accelerator to a subcritical reactor core by means of a neutron spallation target interface. This paper investigates the benefits of multiple spallation targets in ADSRs. The motivation behind this is, firstly, to improve the overall reliability of the accelerator-reactor system, and, secondly, to evaluate other potential advantages such as lower beam power requirements. The results show that a system containing two or three spallation targets, coupled to independent accelerators, offers better neutronic performance. This is demonstrated through the increased effective multiplication factor (keff) in the two- and three-target configurations and a more uniform neutron flux distribution. A multiple-target ADSR also proves effective in mitigating the impact of frequent beam interruptions, a pressing issue that needs to be addressed for the ADSR concept to advance. Assuming no simultaneous beam shutdowns, the two- and three-target configurations reduce the risk of fuel cladding failure due to thermal cyclic fatigue. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Photoluminescence (PL) spectra of GaInNAs/GaAs multiple quantum wells grown on a GaAs substrate by molecular beam epitaxy are measured in a range of temperatures and excitation power densities. The energy position of the dominant PL peak shows an anomalous S-shape temperature dependence instead of the Varshni relation. By careful inspection, especially for the PL under lower excitation power density, two near bandedge peaks are well identified. These are assigned to carriers localized in nitrogen-induced bound states and interband excitonic recombinations, respectively. It is suggested that the temperature-induced switch of such two luminescence peaks in relative intensity causes a significant mechanism responsible for the S-shape shift observed in GaInNAs. A quantitative model based on the thermal depopulation of carriers is used to explain the temperature dependence of the PL peak related to N-induced bound states.
Resumo:
A fully-differential switched-capacitor sample-and-hold (S/H) circuit used in a 10-bit 50-MS/s pipeline analog-to-digital converter (ADC) was designed and fabricated using a 0.35-μm CMOS process. Capacitor fliparound architecture was used in the S/H circuit to lower the power consumption. In addition, a gain-boosted operational transconductance amplifier (OTA) was designed with a DC gain of 94 dB and a unit gain bandwidth of 460 MHz at a phase margin of 63 degree, which matches the S/H circuit. A novel double-side bootstrapped switch was used, improving the precision of the whole circuit. The measured results have shown that the S/H circuit reaches a spurious free dynamic range (SFDR) of 67 dB and a signal-to-noise ratio (SNR) of 62.1 dB for a 2.5 MHz input signal with 50 MS/s sampling rate. The 0.12 mm~2 S/H circuit operates from a 3.3 V supply and consumes 13.6 mW.
New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)
Resumo:
Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e mu A of Xe-129(43+), 22 e mu A of Bi-209(41+), and 1.5 e mu A of Bi-209(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e mu A of Xe-129(27+) and 152 e mu A of Xe-129(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and Xe-129(27+), Kr-78(19+), Bi-209(31+), and Ni-58(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.
Resumo:
Restless Legs Syndrome (RLS) is a common neurological disorder affecting nearly 15% of the general population. Ironically, RLS can be described as the most common condition one has never heard of. It is usually characterised by uncomfortable, unpleasant sensations in the lower limbs inducing an uncontrollable desire to move the legs. RLS exhibits a circadian pattern with symptoms present predominantly in the evening or at night, thus leading to sleep disruption and daytime somnolence. RLS is generally classified into primary (idiopathic) and secondary (symptomatic) forms. Primary RLS includes sporadic and familial cases of which the age of onset is usually less than 45 years and progresses slowly with a female to male ratio of 2:1. Secondary forms often occur as a complication of another health condition, such as iron deficiency or thyroid dysfunction. The age of onset is usually over 45 years, with an equal male to female ratio and more rapid progression. Ekbom described the familial component of the disorder in 1945 and since then many studies have been published on the familial forms of the disorder. Molecular genetic studies have so far identified ten loci (5q, 12q, 14p, 9p, 20p, 16p, 19p, 4q, 17p). No specific gene within these loci has been identified thus far. Association mapping has highlighted a further five areas of interest. RLS6 has been found to be associated with SNPs in the BTBD9 gene. Four other variants were found within intronic and intergenic regions of MEIS1, MAP2K5/LBXCOR1, PTPRD and NOS1. The pathophysiology of RLS is complex and remains to be fully elucidated. Conditions associated with secondary RLS, such as pregnancy or end-stage renal disease, are characterised by iron deficiency, which suggests that disturbed iron homeostasis plays a role. Dopaminergic dysfunction in subcortical systems also appears to play a central role. An ongoing study within the Department of Pathology (University College Cork) is investigating the genetic characteristics of RLS in Irish families. A three generation RLS pedigree RLS3002 consisting of 11 affected and 7 unaffected living family members was recruited. The family had been examined for four of the known loci (5q, 12q, 14p and 9p) (Abdulrahim 2008). The aim of this study was to continue examining this Irish RLS pedigree for possible linkage to the previously described loci and associated regions. Using informative microsatellite markers linkage was excluded to the loci on 5q, 12q, 14p, 9p, 20p, 16p, 19p, 4q, 17p and also within the regions reported to be associated with RLS. This suggested the presence of a new unidentified locus. A genome-wide scan was performed using two microsatellite marker screening sets (Research Genetics Inc. Mapping set and the Applied Biosystems Linkage mapping set version 2.5). Linkage analysis was conducted under an autosomal dominant model with a penetrance of 95% and an allele frequency of 0.01. A maximum LOD score of 3.59 at θ=0.00 for marker D19S878 indicated significant linkage on chromosome 19p. Haplotype analysis defined a genetic region of 6.57 cM on chromosome 19p13.3, corresponding to 2.5 Mb. There are approximately 100 genes annotated within the critical region. Sequencing of two candidate genes, KLF16 and GAMT, selected on the assumed pathophysiology of RLS, did not identify any sequence variant. This study provides evidence of a novel RLS locus in an Irish pedigree, thus supporting the picture of RLS as a genetically heterogeneous trait.
Resumo:
INTRODUCTION: Increasing number of stretch-shortening contractions (SSCs) results in increased muscle injury. METHODS: Fischer Hybrid rats were acutely exposed to an increasing number of SSCs in vivo using a custom-designed dynamometer. Magnetic resonance imaging (MRI) imaging was conducted 72 hours after exposure when rats were infused with Prohance and imaged using a 7T rodent MRI system (GE Epic 12.0). Images were acquired in the transverse plane with typically 60 total slices acquired covering the entire length of the hind legs. Rats were euthanized after MRI, the lower limbs removed, and tibialis anterior muscles were prepared for histology and quantified stereology. RESULTS: Stereological analyses showed myofiber degeneration, and cellular infiltrates significantly increased following 70 and 150 SSC exposure compared to controls. MRI images revealed that the percent affected area significantly increased with exposure in all SSC groups in a graded fashion. Signal intensity also significantly increased with increasing SSC repetitions. DISCUSSION: These results suggest that contrast-enhanced MRI has the sensitivity to differentiate specific degrees of skeletal muscle strain injury, and imaging data are specifically representative of cellular histopathology quantified via stereological analyses.