895 resultados para Low voltage systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infection is a major clinical problem associated with the use of intravenous catheters.The efficacy of a direct electric current (10µA, 9V) via electrode-conducting carbon impregnated catheters to prevent colonisation of catheters by micro-organisms was investigated. The range of organisms susceptible to 10µA was determined by a zone of inhibition test. The catheters acting as the anode and the cathode were inserted into a nutrient agar plate inoculated with a lawn of bacteria. There was no zone of inhibition observed around the anode. Organisms susceptible to 10µA at the cathode were Staphylococcus aureus (2 strains), Staphylococcus epidermidis (5 strains), Escherichia coli and Klebsiella pneumoniae (2 strains each), and one strain of the following micro-organisms: Staphylococcus hominis, Proteus mirabilis, Pseudomonas aeruginosa and Candida albicans. The zones ranged from 6 to 16 mm in diameter according to the organisms under test. The zone size was proportional to the amperage (10 - 100 µA) and the number of organisms on the plate. Ten µA did not prevent adhesion of staphylococci to the cathode nor did it affect their growth in nutrient broth. However, it was bactericidal to adherent bacteria on the cathodal catheter and significantly reduced the number of bacteria on the catheter after 4 to 24 h application of electricity. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated.The mechanisms of the bactericidal activity associated with the cathode were investigated with S. epidermidis and S. aureus. The inhibition zone was greatly reduced in the presence of catalase. There was no zone around the cathode when the test was carried out under anaerobic conditions. Hydrogen peroxide was produced at the cathode surface under aerobic conditions, but not in the absence of oxygen. A salt-bridge apparatus was used to demonstrate further that hydrogen peroxide was produced at the cathode, and chlorine at the anode. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated. Antibacterial activity was reduced under anaerobic conditions, which is compatible with the role of hydrogen peroxide as a primary bactericidal agent of electricity associated with the cathode. A reduction in chloride ions did not significantly reduce the antibacterial activity suggesting chlorine plays only a minor role in the bactericidal activity against organisms attached to anodal electrode surfaces. The bactericidal activity of electric current associated with the cathode and H202 was greatly reduced in the presence of 50 μM to 0.5 mM magnesium ions in the test menstrum. Ten μA applied via the catheters did not prevent the initial biofilm growth by the adherent bacteria but reduced the number of bacteria in the biofilm by 2 log order aiter 24 h. The results suggested that 10 μA may prevent the colonisation of catheters by both the extra~ and intra-luminal routes. The localised production of hydrogen peroxide and chlorine and the intrinsic activity due to electric current may offer a useful method for the eradication of bacteria from catheter surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proposal to increase the existing residential LV grid voltage from 230 V to 300 V has been made in order to increase existing network capacity. A power-electronic AC-AC converter is then used to provide 230 V at each property. The equipment can also provide power-quality improvements to the network and load. Several constraints such as temperature rise at the converter location lead to a converter design requiring very high efficiency. In this paper different AC/AC converter topologies are presented which compares the power quality benefits, size and efficiency of each converter. The design and the control technique of the most suitable topology are verified using simulation and preliminary experimentally results of prototype hardware are also included. © 2013 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an urgent need for fast, non-destructive and quantitative two-dimensional dopant profiling of modern and future ultra large-scale semiconductor devices. The low voltage scanning electron microscope (LVSEM) has emerged to satisfy this need, in part, whereby it is possible to detect different secondary electron yield values (brightness in the SEM signal) from the p-type to the n-type doped regions as well as different brightness levels from the same dopant type. The mechanism that gives rise to such a secondary electron (SE) contrast effect is not fully understood, however. A review of the different models that have been proposed to explain this SE contrast is given. We report on new experiments that support the proposal that this contrast is due to the establishment of metal-to-semiconductor surface contacts. Further experiments showing the effect of instrument parameters including the electron dose, the scan speeds and the electron beam energy on the SE contrast are also reported. Preliminary results on the dependence of the SE contrast on the existence of a surface structure featuring metal-oxide semiconductor (MOS) are also reported. Copyright © 2005 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis aims at investigating the evolution of physico-chemical and electrical properties relevant to low-voltage power cables for nuclear application when subjected to typical nuclear power plant (NPP) environments i.e., to gamma radiation and high temperature. This research is part of the European Project Horizon 2020 TeaM Cables, which aims at providing a novel methodology for efficient and reliable NPP cable aging management to NPP operators. The analyzed samples consist of both coaxial and twisted pair cables with different polymeric compounds used as primary insulation. Insulating materials are based on the same silane cross-linked polyethylene matrix with different additives and fillers. In order to characterize the material response to the environmental stresses, various experimental techniques have been used. These characterizations range from the microscale chemical response e.g. by FTIR, OIT and DSC, to the macroscale electrical and mechanical behavior. A significant part of this Thesis is given to the correlation of the response to aging among the different measured properties. It has been shown that it could be possible to connect both the chemical and mechanical properties of the investigated XLPE cables with the electrical ones. In particular, the high-frequency dielectric response allows an effective monitoring of both the early periods of aging, controlled by the antioxidant consumption kinetics, and then the subsequent oxidation of the polymer matrix. Therefore, dielectric spectroscopy showed to be capable of assessing the LV cable aging state and, it might be used as an aging marker for cable diagnostic. The last part of the manuscript focuses on the building of a predictive modelling approach of LV cable conditions subjected to radio-chemical aging. It resulted into obtaining a lifetime curve which relates the aging factor to which the cable is subjected to, namely the dose rate, with the limit value of the considered electrical property (tanδ).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Global warming and climate change have been among the most controversial topics after the industrial revolution. The main contributor to global warming is carbon dioxide (CO2), which increases the temperature by trapping heat in the atmosphere. Atmospheric CO2 concentration before the industrial era was around 280 ppm for a long period, while it has increased dramatically since the industrial revolution up to approximately 420 ppm. According to the Paris agreement it is needed to keep the temperature increase up to 2°C, preferably 1.5° C, to prevent reaching the tipping point of climate change. To keep the temperature increase below the range, it is required to find solutions to reduce CO2 emissions. The solutions can be low-carbon systems and transition from fossil fuels to renewable energy sources (RES). This thesis is allocated to the assessment of low-carbon systems and the reduction of CO2 by using RES instead of fossil fuels. One of the most important aspects to define the location and capacity of low-carbon systems is CO2 mass estimation. As mentioned, high-emission systems can be substituted by low-carbon systems. An example of high-emission systems is dredging. The global CO2 emission from dredging is relatively high which is associated with the growth of marine transport in addition to its high emission. Thus, ejectors system as alternative for dredging is investigated in chapter 2. For the transition from fossil fuels to RES, it is required to provide solutions for the RES storage problem. A solution could be zero-emission fuels such as hydrogen. However, the production of hydrogen requires electricity, and electricity production emits a large amount of CO2. Therefore, the last three chapters are allocated to hydrogen generation via electrolysis, at the current condition and scenarios of RES and variation of cell characteristics and stack materials, and its delivery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El present projecte pretén oferir una solució constructiva de les instal•lacions de baixa tensió, mesures contra incendis i climatització d’un supermercat i també l’obtenció d’una qualificació energètica de l’establiment. Aquesta activitat terciari d’ús comercial és classifica com un comerç al detall amb predomini de productes alimentaris, begudes i una altra àmplia gamma de mercaderies (com són els cosmètics, detergents, productes de papereria, etc.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El projecte es basa en una proposta de modificació d’una Norma Tecnològica d’Edificació sobre les instal•lacions elèctriques de baixa tensió del 1973, per tal de donar-li un caire més actual

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disseny d’una xarxa de distribució d’alta tensió de tercera categoria de 25 kV subterrània, a partir d’ara mitja tensió (MT), amb deu centres de transformació i distribució de 1000 kVA cadascun. La reforma d’un centre de transformació i distribució de 630 kVA i el disseny de la xarxa de baixa tensió. Amb la finalitat de donar subministrament d’energia elèctrica a les industries d’un polígon del terme municipal de Torroella de Montgrí (GIRONA) i obtenir l’autorització administrativa per la posterior posada en servei d’aquesta instal•lació.No queda inclòs en aquest projecte la instal•lació d’enllumenat públic

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taajuusmuuttajat aiheuttavat toimintansa seurauksena runsaasti laajakaistaisia sähkömagneettisia häiriöitä. Häiriöt etenevät sekä johtumalla että säteilemällä ja ne ovat seurausta pääasiassa taajuusmuuttajien toimintaan perustuvista nopeista kytkentäilmiöistä sekä puolijohdekomponenttien epälineaarisuuksista. Sähkömagneettisille häiriöille määritellään suurimmat sallitut tasot useissa EMC-standardeissa. Taajuusmuuttajia koskevia EMC-standardia on neljä; tuotestandardi EN 61800-3, harmonisia virtoja pienjänniteverkoissa käsittelevä EN 61000-3-12 sekä yleiset standardit EN 61000-6-1, -6-2 ja EN 61000-6-3, -6-4. Tämän diplomityön tarkoituksena on tutkia ja koota yhteen edellä mainittujen standardien sisältämät vaatimukset. Työn pääpaino on kohdistettu häiriöpäästöille asetettuihin vaatimuksiin, sillä häiriöiden sietoon liittyvien vaatimusten täyttäminen ei taajuusmuuttajien kohdalla yleensä tuota ongelmia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ajoneuvoissa, kuten busseissa, käytetään yleensä 24 VDC järjestelmiä ja tämä ei muutu myöskään sähköajoneuvojen kohdalla. Sähköajoneuvoissakin tarvitaan siis 24 VDC matalajänniteakustoja valoille, pyyhkijöille ja muille matalan jännitteen järjestelmille. Lisäksi sähköajoneuvoissa on esimerkiksi ilmastointi ja paineilmankompressori, jotka tarvitsevat taajuusmuuttajan pyörittämään niitä. Tässä työssä suunnitellaan suuren virran piilevy DC/DC-muuntimeen, joka on osa ajoneuvokäyttöön suunnitellun invertterin ja DC/DC-muuntimen yhdistelmälaitetta. Työn pääpaino on piirilevyn suunnittelussa, mutta työssä kerrotaan lyhyesti koko laitteen kytkentä ja käyttötarkoitus. Työssä kerrotaan myös tehopiirilevylle tulevien komponenttien valinta, mitoitus ja jäähdytys. Käydään läpi suuren virran piirilevysuunnittelun mitoitusperiaatteet ja mitä seikkoja siinä erityisesti tulee ottaa huomioon. Lisäksi käsitellään piirilevyn liityntöjä ja virtakiskojen lämpenemää virranahtautumisen takia. Suunniteltua piirilevyä mitataan ja sen toimintaa kokeillaan prototyyppilaitteessa. Protoyyppilaitteella havaitaan virtakiskojen lämpenevän liikaa ja huomataan ongelma kytkenssä. Kytkentää korjattiin ja toimintaa analysoitiin uudestaan, jonka jälkeen havaittiin piirilevyn lämpenemän tippuneen 20 °C. Lopputuloksena piirilevyn lämpenemä, korjatulla kytkennällä, on suunnitellun mukainen. Lopussa esitetään piirilevyn korvaamista moduuliratkaisulla laitteen parantamiseksi sarjatuotantoon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disseny d’una xarxa de distribució d’alta tensió de tercera categoria de 25 kV subterrània, a partir d’ara mitja tensió (MT), amb deu centres de transformació i distribució de 1000 kVA cadascun. La reforma d’un centre de transformació i distribució de 630 kVA i el disseny de la xarxa de baixa tensió. Amb la finalitat de donar subministrament d’energia elèctrica a les industries d’un polígon del terme municipal de Torroella de Montgrí (GIRONA) i obtenir l’autorització administrativa per la posterior posada en servei d’aquesta instal•lació. No queda inclòs en aquest projecte la instal•lació d’enllumenat públic

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El present projecte pretén oferir una solució constructiva de les instal•lacions de baixa tensió, mesures contra incendis i climatització d’un supermercat i també l’obtenció d’una qualificació energètica de l’establiment. Aquesta activitat terciari d’ús comercial és classifica com un comerç al detall amb predomini de productes alimentaris, begudes i una altra àmplia gamma de mercaderies (com són els cosmètics, detergents, productes de papereria, etc.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A status report of the modelling and simulation work that is being undertaken as part of the TIMES (Totally Integrated More Electric Systems) project is presented. Dynamic power quality simulations have been used to asses the performance of the electrical system of a EMA based actuation system for an Airbus A330 size aircraft, for both low voltage 115 V, and high voltage 230 V three-phase AC systems. The high voltage system is shown to have benefits in terms of power quality and reduced size and weight of equipment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distribution systems are the first volunteers experiencing the benefits of smart grids. The smart grid concept impacts the internal legislation and standards in grid-connected and isolated distribution systems. Demand side management, the main feature of smart grids, acquires clear meaning in low voltage distribution systems. In these networks, various coordination procedures are required between domestic, commercial and industrial consumers, producers and the system operator. Obviously, the technical basis for bidirectional communication is the prerequisite of developing such a coordination procedure. The main coordination is required when the operator tries to dispatch the producers according to their own preferences without neglecting its inherent responsibility. Maintenance decisions are first determined by generating companies, and then the operator has to check and probably modify them for final approval. In this paper the generation scheduling from the viewpoint of a distribution system operator (DSO) is formulated. The traditional task of the DSO is securing network reliability and quality. The effectiveness of the proposed method is assessed by applying it to a 6-bus and 9-bus distribution system.