941 resultados para Low intensity pulsed ultrasound
Resumo:
Mode of access: Internet.
Resumo:
Aim of study: To examine the prevalence of low intensity symptom severity states in patients taking placebo, rofecoxib 12.5 mg once daily, rofecoxib 25 mg once daily, or ibuprofen 800 mg three times daily using a post-hoc definition of low pain intensity states (BLISS Index) based on the WOMAC Index. Methods: Two 6-week, double-blind, parallel-group, placebocontrolled, ibuprofen-comparator studies were conducted to measure the efficacy of rofecoxib in patients with knee or hip osteoarthritis. These studies employed a flare design requiring a minimum level of symptoms at entry following discontinuation of prior analgesics. The WOMAC Pain subscale (100 mm visual analog scale) was used as the pain measure. In separate analyses, WOMAC pain subscale scores from each patient were compared to five thresholds of pain:%5 mm, %10 mm, %15 mm, %20 mm, and %25 mm. The percent of patients with BLISS states (1) on average over 6 weeks, (2) at any time during the study, and (3) at week 6 was computed for each treatment group and threshold. The treatment group percentages were compared using Fisher’s exact test. Results: During the study, patients received placebo (N Z 143), rofecoxib 12.5 mg (N Z 461), rofecoxib 25 mg (N Z 459), or ibuprofen (N Z 465). For each pain threshold and treatment group, the percent of patients with BLISS states at any time (e.g., 50% for rofecoxib 25 mg) exceeded the percentage at week 6 (e.g., 40% for rofecoxib 25 mg) which, in turn, exceeded the percentage with BLISS states on average (e.g., 32% for rofecoxib 25 mg). The percentages of patients in the active treatment groups with BLISS states on average were significantly different than observed in the placebo group at the%15 mm threshold (8–11% points vs placebo, P ! 0.01), %20 mm level (10–15% points, P ! 0.01), and %25 mm level (14–17% points, P ! 0.001). Significant differences between the active treatments and placebo were also observed at the %10 mm threshold (8–9% points, P ! 0.05) for measurements at week 6 and at the%10 (12–14% points, P !0.001) and%5 mm thresholds (5–7% points, P ! 0.05) for patients with BLISS states at any time. Conclusion: These measures of BLISS states differentiate all three active treatment groups from placebo and further confirm, at an individual patient level, the clinical benefit of rofecoxib in the treatment of osteoarthritis. Furthermore, they provide information on the prevalence of patients achieving low (%15 mm, %20 mm, %25 mm), and very low (%5 mm, %10 mm) pain severity states.
Resumo:
Transcranial magnetic stimulation (TMS) studies indicate that the observation of other people's actions influences the excitability of the observer's motor system. Motor evoked potential (MEP) amplitudes typically increase in muscles which would be active during the execution of the observed action. This 'motor resonance' effect is thought to result from activity in mirror neuron regions, which enhance the excitability of the primary motor cortex (M1) via cortico-cortical pathways. The importance of TMS intensity has not yet been recognised in this area of research. Low-intensity TMS predominately activates corticospinal neurons indirectly, whereas high-intensity TMS can directly activate corticospinal axons. This indicates that motor resonance effects should be more prominent when using low-intensity TMS. A related issue is that TMS is typically applied over a single optimal scalp position (OSP) to simultaneously elicit MEPs from several muscles. Whether this confounds results, due to differences in the manner that TMS activates spatially separate cortical representations, has not yet been explored. In the current study, MEP amplitudes, resulting from single-pulse TMS applied over M1, were recorded from the first dorsal interosseous (FDI) and abductor digiti minimi (ADM) muscles during the observation of simple finger abductions. We tested if the TMS intensity (110% vs. 130% resting motor threshold) or stimulating position (FDI-OSP vs. ADM-OSP) influenced the magnitude of the motor resonance effects. Results showed that the MEP facilitation recorded in the FDI muscle during the observation of index-finger abductions was only detected using low-intensity TMS. In contrast, changes in the OSP had a negligible effect on the presence of motor resonance effects in either the FDI or ADM muscles. These findings support the hypothesis that MN activity enhances M1 excitability via cortico-cortical pathways and highlight a methodological framework by which the neural underpinnings of action observation can be further explored. © 2013 Loporto et al.
Resumo:
This thesis aims to understand the behavior of a low-rise unreinforced masonry building (URM), the typical residential house in the Netherlands, when subjected to low-intensity earthquakes. In fact, in the last decades, the Groningen region was hit by several shallow earthquakes caused by the extraction of natural gas. In particular, the focus is addressed to the internal non-structural walls and to their interaction with the structural parts of the building. A simple and cost-efficient 2D FEM model is developed, focused on the interfaces representing mortar layers that are present between the non-structural walls and the rest of the structure. As a reference for geometries and materials, it has been taken into consideration a prototype that was built in full-scale at the EUCENTRE laboratory of Pavia (Italy). Firstly, a quasi-static analysis is performed by gradually applying a prescribed displacement on the roof floor of the structure. Sensitivity analyses are conducted on some key parameters characterizing mortar. This analysis allows for the calibration of their values and the evaluation of the reliability of the model. Successively, a transient analysis is performed to effectively subject the model to a seismic action and hence also evaluate the mechanical response of the building over time. Moreover, it was possible to compare the results of this analysis with the displacements recorded in the experimental tests by creating a model representing the entire considered structure. As a result, some conditions for the model calibration are defined. The reliability of the model is then confirmed by both the reasonable results obtained from the sensitivity analysis and the compatibility of the values obtained for the top displacement of the roof floor of the experimental test, and the same value acquired from the structural model.
Resumo:
Osteoporosis and its consequent fractures are a great social and medical problem mainly occurring in post-menopausal women. Effective forms of prevention and treatment of osteoporosis associated with lower costs and the least side effects are needed. Electrical fields are able to stimulate osteogenesis in fractures, but little is known about their action on osteoporotic tissue. The aim of the present study was to determine by bone densitometry the effects of electrical stimulation on ovariectomized female Wistar rats. Thirty rats (220 ± 10 g) were divided into three groups: sham surgery (SHAM), bilateral ovariectomy (OVX) and bilateral ovariectomy + electrical stimulation (OVX + ES). The OVX + ES group was submitted to a 20-min session of a low-intensity pulsed electrical field (1.5 MHz, 30 mW/cm²) starting on the 7th day after surgery, five times a week (total = 55 sessions). Global, spine and limb bone mineral density were measured by dual-energy X-ray absorptiometry (DXA Hologic 4500A) before surgery and at the end of protocol (84 days after surgery). Electrical stimulation improved (P < 0.05) global (0.1522 ± 0.002), spine (0.1502 ± 0.003), and limb (0.1294 ± 0.003 g/cm²) bone mineral density compared to OVX group (0.1447 ± 0.001, 0.1393 ± 0.002, and 0.1212 ± 0.001, respectively). The OVX + ES group also showed significantly higher global bone mineral content (9.547 ± 0.114 g) when compared to both SHAM (8.693 ± 0.165 g) and OVX (8.522 ± 0.207 g) groups (P < 0.05). We have demonstrated that electrical fields stimulate osteogenesis in ovariectomized female rats. Their efficacy in osteoporosis remains to be demonstrated.
Resumo:
Four emerging high-energy non-thermal technologies may replace or augment heating for producing sterile low-acid food products. High pressure, high-voltage pulsed electric field, high-energy ultrasound and high-intensity pulsed light are all capable of reducing bacterial spore counts under certain conditions. However, only non-continuous high pressure treatments, at temperatures higher than ambient, are currently capable of completely inactivating spores and producing sterile food products. The first three technologies also reduce the resistance of spores to inactivation by heat.
Resumo:
In endemic areas with low prevalence and low intensity of infection, the diagnosis of hepatic pathology due to the Schistosoma mansoni infection is very difficult. In order to establish the hepatic morbidity, a double-blind study was achieved in Venezuelan endemic areas, with one group of patients with schistosomiasis and the other one of non-infected people, that were evaluated clinically and by abdominal ultrasound using the Cairo classification. Schistosomiasis diagnosis was established based on parasitologic and serological tests. The increase of the hepatic size at midclavicular and midsternal lines (in hepatometry) and the hard liver consistency were the clinical parameters able to differentiate infected persons from non infected ones, as well as the presence of left lobe hepatomegaly detected by abdominal ultrasound. The periportal thickening, especially the mild form, was frequent in all age groups in both infected and uninfected patients. There was not correlation between the intensity of infection and ultrasound under the current circumstances. Our data suggest that in Venezuela, a low endemic area of transmission of schistosomiasis, the hepatic morbidity is mild and uncommon. The Cairo classification seems to overestimate the prevalence of periportal pathology. The specificity of the method must be improved, especially for the recognition of precocious pathology. Other causes of hepatopathies must be investigated.
Resumo:
Herpes simplex virus (HSV) is one of the most common viral infections of the human being. Although most of the seropositive persons do not manifest symptoms, infected individuals may present recurrent infections, characterized by cold sores. HSV-1 infection can result in potentially harmful complications in some patients, especially in those with compromised immunity. We report a clinical case of a patient with severe oral HSV-1 infection in the lower lip. The treatment of the lesions with the association of high-intensity (erbium-doped yttrium aluminum garnet, 2.94 mu m, 80 mJ/pulse, 2-4 Hz) and low-intensity (indium gallium aluminum phosphide, 660 nm, 3.8 J/cm(2), 10mW) lasers has not been reported in the literature. During treatment, no systemic or topical medication was used. Pain sensitivity was completely gone after the first irradiation with the low-intensity laser. During the healing process, lesions were traumatized twice, on the days 4 and 7. Even though the lesions were completely healed within 10 days.
Resumo:
Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
The response of bone metabolism is directly related to hormonal factors and mechanical stimuli that the bone is exposed. The ultrasonic energy on bone healing have been shown to be crucial for the stimulation and improvement in quality of newly formed tissue. The aim of this study was to analyze the action of low intensity ultrasound on bone healing of tibial osteotomy in rats subjected to tail suspension, through histological analysis and histomorphometry. Eighteen Rattus norvegicus albinos, Wistar, adults were divided into three groups, arranged as follows: G1 (n = 6), who remained free for a period of 15 days, G2 (n = 5), suspended by the tail for a period of 15 days and G3 (n = 7), suspended by the tail for a period of 36 days. In all three groups, both tibias were subjected to mono-cortical bone injury 4X2 mm in the medial region of the diaphysis, and the left limb was used as control and the right limb undergoing treatment with ultrasound (U.S.). The right tibia was treated with pulsed ultrasound at a frequency of 1.5 MHz, duty cycle 1:4, 30mW/cm2, for 12 sessions of 20 minutes each. Samples of tibia were subjected to histological analysis, blindly, with light microscopy and histomorphometric analysis by specific software Image-Pro 6.1. The average percentage of new bone formation were subjected to analysis of variance in subdivided parcels and multiple comparison test "Student-Newman-Keuls (SNK), with a significance level of 5%. The average values and standard deviations of the percentage of newly formed bone for the groups showed the least amount of bone repair G1t (13.62% ± 4.88%) - G1c (8.68% ± 4.16%) compared G2t groups (27.17% ± 11.36%) - G2c (10.10% ± 7.90%) and G3t (23.19% ± 5.61%) - G3c (15.74% ± 7 08%). However, the mean values and standard deviations of the percentage of newly formed bone repair in the tibia treated G2t and G3t were significantly higher when compared to the repair of tibia in the control group (G2c and G3c). Consequently, we conclude that ultrasound has helped to accelerate bone repair in both the presence and absence of cargo.