937 resultados para Locked screw (Orthopedy)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Letras - FCLAS
Resumo:
Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.
Resumo:
Statement of problem. An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps.Purpose. The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by cementing titanium cylinders to the prefabricated framework (group CTF). This procedure was developed to correct the misfit between frameworks and loaded implants.Material and methods. Four internal hexagon cylindrical implants were placed 10 mm apart in a polyurethane block by using the surgical guides of the corresponding implant system. Previously fabricated titanium frameworks (n=10) were divided into 2 groups. In group STF, prefabricated machined frameworks were used (n=5), and, in group CTF, the frameworks were fabricated by using a passive fit procedure, which was developed to correct the misfit between the cast titanium frameworks and supporting dental implants (n=5). Both groups were screw-retained under torque control (10 Ncm). Six strain gauges were placed on the upper surface of the polyurethane block, and 3 strain measurements were recorded for each framework. Data were analyzed with the Student t test (alpha=.05).Results. The mean microstrain values between the framework and the implants were significantly higher for group STF (2517 me) than for group CTF (844 me) (P<.05).Conclusions. Complete-arch implant frameworks designed for load application and fabricated by using the passive fit procedure decreased the strain between the frameworks and implants more than 1 piece prefabricated machined frameworks.
Resumo:
Purpose: To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).Materials and Methods: Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (alpha = 0.05).Results: RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 mm uniformly coating the hexagonal abutment.Conclusion: DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Objective: A morphological analysis of the bone structure of 02 in patients with rheumatoid arthritis in order to enhance the security of the stabilization procedures for this vertebra. Methods: We retrospectively analyzed 20 CT scans of the cervical spine performed in patients with rheumatoid arthritis; the following parameters were measured: spinolaminar angle, thickness and length of C2 lamina. Results: The mean values are: 5.92mm and 5.87mm for thickness of right and left laminae retrospectively, 27.75mm for right lamina length and 27.94mm for left lamina length, and 44.7 degrees for spinolaminar angle. Conclusion: The values obtained are consistent with studies in normal subjects published by other groups, with no apparent need for change in the screw placement technique. Level of Evidence IV, Case Series.
Resumo:
Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Intensive scheduling in sports requires athletes to resume physical activity shortly after injury. The purpose of this study was to investigate early isokinetic muscle strength and knee function on bone-patellar tendon-bone (BPTB) ACL reconstruction with double femoral pin fixation or interference screw technique. A prospective study was conducted from 2008 to 2009, with 48 athletes who received femoral BPTB fixation with interference screw (n = 26) or double pin (n = 22). Clinical (IKDC objective score and hop test) and isokinetic muscle strength (peak torque (PT), PT/body weight and flexion/extension rate (F/E) in 60 and 240A degrees/s) were analyzed at 6 months of follow-up. Analysis at baseline showed no differences between groups before surgery related to age, gender, associated injury, Tegner or Lysholm score; thus showing that groups were similar. During follow-up, however, there were significant differences between the two groups in some of the isokinetic muscle strength: PT/BW 60A degrees/s (Double Pin = 200% +/- A 13% vs. Interference Screw = 253% +/- A 16%*, *P = 0.01); F/E 60A degrees/s (Double Pin = 89% +/- A 29%* vs. Interference Screw = 74% +/- A 12%, *P = 0.04). No statistical differences between groups were observed on IKDC objective score, hop test and complications. The significant muscle strength outcome of the interference screw group found in this study gives initial evidence that this fixation technique is useful for athletes that may need accelerated rehabilitation. Early return to sports ability signaled by isokinetic muscle strength is of clinical relevance as it is one of the main goals for athletes' rehabilitation. III.
Resumo:
Using the solutions of the gap equations of the magnetic-color-flavor-locked (MCFL) phase of paired quark matter in a magnetic field, and taking into consideration the separation between the longitudinal and transverse pressures due to the field-induced breaking of the spatial rotational symmetry, the equation of state (EoS) of the MCFL phase is self-consistently determined. Implications for stellar models of magnetized (self-bound) strange stars and hybrid (MCFL core) stars are discussed.
Resumo:
Gegenstand der Arbeit: Die distale Radiusfraktur ist der häufigste Bruch des Menschen. Neben etablierten Verfahren wie der dorsalen und palmaren Plattenosteosynthese gibt es seit Kurzem neuartige minimalinvasive Osteosynthesesysteme. Gegenstand der vorliegenden Arbeit ist die Untersuchung der biomechanischen Stabilität von zwei neuartigen Implantaten für die distale extraartikuläre Radiusfraktur. rnMethodik: Es handelt sich einerseits um das System XSCREW (Zimmer, Freiburg i. Br., Deutschland), eine kanülierte Schraube, die über den Processus styloideus eingeführt wird und mit bis zu neun Bohrdrähten im Knochen fixiert werden kann. Das Vergleichsimplantat DorsalNailPlate (HandInnovations, Miami, Florida, USA) ist ein Hybrid aus einer dorsalen Platte und einem Marknagel. Beide Systeme wurden an 8 paarigen frischen unfixierten Leichenradii unter Axialbelastung bis 100 N und Torsionsbelastung bis 1,5 Nm getestet. Die A3-Fraktur wurde durch eine standardisierte Keilosteotomie simuliert. Das Biomaterial wurde prä- und postinterventionell sowie nach einem Dauerbelastungstest unter 1000 Zyklen in Rotation mit 0,5 Hz untersucht. Ein Versagenstest mit steigendem Drehmoment beendete das Experiment. rnErgebnisse: Die XSCREW erreichte eine Axialsteifigkeit von 136 N/mm und eine Torsionssteifigkeit von 0,16 Nm/°. Die DNP erzielte hingegen axial 70 N/mm und torsional 0,06 Nm/°. Der Unterschied zwischen beiden Verfahren war nur für die Torsion eindeutig statistisch auffällig (p=0,012), jedoch nicht für die Axialsteifigkeit (p=0,054). Die ursprüngliche Axial- und Torsionssteifigkeit wurde durch die XSCREW signifikant besser wiederhergestellt als durch die DNP (p=0,012). Beide Verfahren erzielten nach der Intervention signifikant niedrigere Steifigkeiten als die intakten Knochen (p=0,012). Ein Präparat der DNP-Gruppe und vier Präparate der XSCREW-Gruppe überstanden den Dauerbelastungstest. Das Drehmoment bei Versagen war mit der XSCREW höher als mit der DNP, der Unterschied zwischen den Verfahren war signifikant (p=0,043). Die Schwachstellen beider Systeme lagen vorwiegend in der proximalen Verankerung im Knochen. Kirschner-Drähte bzw. Verriegelungsschrauben führten unter andauernder Belastung zu einer Spaltung der Kortikalis im Schaftbereich. Bedingt durch die Ausrichtung der distalen Verriegelungen können mit beiden Implantaten Schäden an der radiocarpalen bzw. radioulnaren Gelenkfläche entstehen. rnZusammenfassung: Die XSCREW ermöglicht insgesamt eine höhere mechanische Stabilität als die DNP. Beide Verfahren sind jedoch einer winkelstabilen palmaren Plattenosteosynthese insbesondere unter rotatorischer Dauerbelastung unterlegen und erreichen nicht die Stabilität eines anderen neuartigen minimalinvasiven Systems.
Resumo:
The goals of any treatment of cervical spine injuries are: return to maximum functional ability, minimum of residual pain, decrease of any neurological deficit, minimum of residual deformity and prevention of further disability. The advantages of surgical treatment are the ability to reach optimal reduction, immediate stability, direct decompression of the cord and the exiting roots, the need for only minimum external fixation, the possibility for early mobilisation and clearly decreased nursing problems. There are some reasons why those goals can be reached better by anterior surgery. Usually the bony compression of the cord and roots comes from the front therefore anterior decompression is usually the procedure of choice. Also, the anterior stabilisation with a plate is usually simpler than a posterior instrumentation. It needs to be stressed that closed reduction by traction can align the fractured spine and indirectly decompress the neural structures in about 70%. The necessary weight is 2.5 kg per level of injury. In the upper cervical spine, the odontoid fracture type 2 is an indication for anterior surgery by direct screw fixation. Joint C1/C2 dislocations or fractures or certain odontoid fractures can be treated with a fusion of the C1/C2 joint by anterior transarticular screw fixation. In the lower and middle cervical spine, anterior plating combined with iliac crest or fibular strut graft is the procedure of choice, however, a solid graft can also be replaced by filled solid or expandable vertebral cages. The complication of this surgery is low, when properly executed and anterior surgery may only be contra-indicated in case of a significant lesion or locked joints.
Resumo:
Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.
Resumo:
STUDY DESIGN.: Cadaver study. OBJECTIVE.: To determine bone strength in vertebrae by measuring peak breakaway torque or indentation force using custom-made pedicle probes. SUMMARY OF BACKGROUND DATA.: Screw performance in dorsal spinal instrumentation is dependent on bone quality of the vertebral body. To date no intraoperative measuring device to validate bone strength is available. Destructive testing may predict bone strength in transpedicular instrumentations in osteoporotic vertebrae. Insertional torque measurements showed varying results. METHODS.: Ten human cadaveric vertebrae were evaluated for bone mineral density (BMD) measurements by quantitative computed tomography. Peak torque and indentation force of custom-made probes as a measure for mechanical bone strength were assessed via a transpedicular approach. The results were correlated to regional BMD and to biomechanical load testing after pedicle screw implementation. RESULTS.: Both methods generated a positive correlation to failure load of the respective vertebrae. The correlation of peak breakaway torque to failure load was r = 0.959 (P = 0.003), therewith distinctly higher than the correlation of indentation force to failure load, which was r = 0.690 (P = 0.040). In predicting regional BMD, measurement of peak torque also performed better than that of indentation force (r = 0.897 [P = 0.002] vs. r = 0.777 [P = 0.017]). CONCLUSION.: Transpedicular measurement of peak breakaway torque is technically feasible and predicts reliable local bone strength and implant failure for dorsal spinal instrumentations in this experimental setting.