994 resultados para Liner
Resumo:
Turbomachinery noise radiating into the rearward arc is an important problem. This noise is scattered by the trailing edges of the nacelle and the jet exhaust, and interacts with the shear layers between the external flow, bypass stream and jet, en route to the far field. In the past a range of relevant model problems involving semi-infinite cylinders have been solved. However, one limitation of these previous solutions is that they do not allow for the jet nozzle protruding a finite distance beyond the end of the nacelle (or in certain configurations being buried a finite distance upstream). With this in mind, we have used the matrix Wiener-Hopf technique to allow precisely this finite nacelle-jet nozzle separation to be included. We have previously reported results for the case of hard-walled ducts, which requires factorisation of a 2 × 2 matrix. In this paper we extend this work by allowing one of the duct walls, in this case the outer wall of the jet pipe, to be acoustically lined. This results in the need to factorise a 3 × 3 matrix, which is completed by use of a combination of pole-removal and Pad́e approximant techniques. Sample results are presented, investigating in particular the effects of exit plane stagger and liner impedance. Here we take the mean flow to be zero, but extension to nonzero Mach numbers in the core and bypass flow has also been completed. Copyright © 2009 by Nigel Peake & Ben Veitch.
Resumo:
某型发动机的火焰筒表面采用高温陶瓷涂层防护.该涂层用添加少量高岭土的玻璃料熔烧而成.由于批量生产时曾出现涂层与金属基体结合强度以及涂层耐酸性降低的问题,追溯工艺流程,发现高岭土原料存在问题.实际上,由于原料不合格导致的涂层质量问题在工艺试制时也偶有发生,但以前主要关注主料玻璃料,较少关注辅料高岭土的问题.本文对涂层的制备工艺及高岭土的作用进行了分析,针对原高岭土存在的问题以及新型高岭土的试用效果,探讨了选用新型高岭土的依据,力图解决当前发动机火焰筒陶瓷涂层的质量控制和提高新机火焰筒组件的性能等问题.……
Avaliação in vitro da incorporação de clorexidina nas propriedades físico-químicas de resinas macias
Resumo:
A incorporação do diacetato de clorexidina em resinas macias para reembasamento de próteses pode se tornar uma boa alternativa na terapia com antimicrobianos usados para candidíase oral, uma vez que é independente da cooperação do paciente. Este trabalho teve como objetivo analisar a hipótese que a incorporação de diacetato de clorexidina em resinas macias não alteraria as suas propriedades físico-químicas. Foram analisadas duas resinas macias, uma à base de polimetilmetacrilato (PMMA) e outra à base de polietilmetacrilato (PEMA), com a incorporação de 0,5%, 1,0% e 2,0% de diacetato de clorexidina, além do grupo controle sem diacetato de clorexidina. Os espécimes foram armazenadas em água destilada a 37 durante 2hrs, 48 hrs, 7, 14, 21 e 28 dias e analisados quanto a cristalinidade do polímero através da difração de Raios X, a dureza mensurada com durômetro na escala shore A, o grau de conversão dos monômeros pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR), a lixiviação de monômeros residuais e a liberação da clorexidina por Cromatografia Líquida de Alta Performace (HPLC). Os resultados mostraram que quanto à cristalinidade dos polímeros nas resinas macias à base de PMMA e de PEMA não alteraram após a incorporação de clorexidina, o que está relacionado à dureza Shore A, que aumentou ao longo do tempo, mas sem alteração significativa para nenhuma das concentrações de diacetato de clorexidina testadas. Já quanto ao grau de conversão, após a incorporação de clorexidina, a resina macia à base de PMMA não apresentou diferença estatisticamente significativa (р>0,05), porém a resina macia à base de PEMA apresentou diminuição significativa do grau de conversão (p<0,05), o que refletiu no aumento significativo da lixiviação de monômeros residuais nas concentrações 0,5% e 1,0% de clorexidina (p<0,05), principalmente nas primeiras 48 horas nessa resina. A resina macia à base de PMMA não apresentou alterações do padrão de lixiviação desses monômeros (р>0,05) e para ambas as resinas a cinética de liberação de clorexidina foi relacionada à lixiviação de monômeros residuais, que para a resina macia à base de PEMA foi maior significativamente nas primeiras 48 horas (p<0,05) e para a resina macia à base de PMMA não teve alteração estatisticamente significativa (р>0,05) se mantendo até o último dia de análise. Desse modo, conclui-se que a incorporação do diacetato de clorexidina não afetou a cristalinidade dos polímeros, inalterando a dureza nas duas resinas, porém o grau de conversão sofreu diminuição após a incorporação de diacetato de clorexidina na resina macia à base de PEMA, o que levou ao aumento da lixiviação de monômeros residuais e curta liberação de clorexidina; enquanto que a resina macia à base de PMMA, devido a não alteração significativa do seu grau de conversão, ocorreu menor lixiviação de monômeros residuais e liberação prolongada de clorexidina.
Resumo:
During 1964, the offshore fishing station, Cochin, took up a programme of exploratory tuna fishing in the deeper waters off Cochin. A side trawler was converted into a tuna long liner for this purpose.
Resumo:
Geomembranes are one of the most commonly used geosynthetics in landfill liner systems. They retain the leachate produced by the waste and prevent leakage. Geomembranes may experience harsh environmental conditions such as extreme temperatures or earthquake loading. Earthquake loading can be an extreme loading case for landfills located in seismic regions. This study, based on dynamic centrifuge testing, investigates the effects of simulated earthquake loading on the tension experienced bythe geomembrane on a landfill slope. The landfill modeled in the dynamic centrifuge test was a municipal solid waste (MSW) landfill cell with a single geomembrane-clay liner system (45° side slope and 10 m slope length). The paper shows that moderate earthquake loading (base acceleration between 0.1g to 0.2g) can result in transient increases of around 20% in geomembrane tension, with permanent tension increases of around 5%.
Resumo:
To control combustion instabilities occurring in LPP gas turbine combustors, several active and passive systems have been developed in recent years. The combustion chamber cooling geometry has the potential to influence instability feedback loops by absorbing acoustical energy inside the combustor. The design of the cooling liner and the geometry of the cooling plenum and the cooling air flow rate have a significant influence on the absorption characteristics of the system. This paper presents the results of a cold flow study which was carried out in the course of a comprehensive study on the influence of the cooling geometry on combustor thermoacoustics. Absorption characteristics of three different cooling liner geometries and non-perforated plates were determined over a frequency range from 50 Hz to 600 Hz for different cooling flow rates and different cooling plenum volumes. The experimental results compared well with results from a low order thermoacoustic network model. The acoustic energy absorption spectrum of a cooling liner with 90°-hole configuration was found to be strongly dependent on cooling flow rate and cooling plenum volume, whereas the absorption spectrum of cooling liners with 25°-holes were found to be strongly dependent on the cooling plenum volume, but less dependent on the cooling air flow rate. All cooling liner setups with perforations were capable of increased acoustic absorption over a broad band of frequencies compared to the case of non-perforated combustor walls. © 2010 by Johannes Schmidt.
Resumo:
A number of wide-ranging monitoring studies have been performed in order to estimate the degree of mercury (Hg) contamination in freshwater ecosystems. Knowledge regarding contamination of different levels of the food chain is necessary for estimation of total pollutant input fluxes and subsequent partitioning among different phases in the aquatic system. The growing international concern about this environmental data is closely related to the strongly developing ecological risk assessment activities. In addition,freshwater monitoring outputs hold a key position in the estimation of the Hg dose consumed by the human population as it is highly dependent on fish consumption. So monitoring of Hg in the tissue of edible fish is extremely important because of contaminated fish has caused serious neurological damage to new born babies and adults. Mercury tends to accumulate in fish tissue, particularly, in the form of methyl mercury, which is about 10 times more toxic than inorganic mercury. The Anzali lagoon is one of the biggest wetland of Guilan province, which joins to the Caspian sea. Many Chemical and industrial factories plus agricultural runoffs and urban and rural sewages are major polluting sources of the Anzali wetland. Since many of those polluting sources drain their wastes directly or indirectly into the Anzali wetland and their sewages may be polluted with Hg, this study was conducted to find out the bioaccumulation of Hg bioaccumulation in pike (Esox lucius) food chain from Anzali lagoon, Iran. Sampling were carried out from July 2004 to July 2005, in addition 318 speciments of 9 fish species were collected. T-Hg was measured by LECO AMA 254 Advanced Mercury Analyzer (USA) according to ASTM standard No D-6722. Each sample was analyzed 3 times. Accuracy of T-Hg analysis was checked by running three samples of Standard Reference Materials; SRM 1633b, SRM 2711 & Sra 2709. Detection limit was 0.001 mg/kg in dry weight. The Accuracy degree of analyzor equipment with RSD<%0.05 (N=7) was between %95.5 and %105. In overal eigth fish species were distingushed in the gut content of 87 speciments of pike with age 1-5 year and maximum length 550mm. The max. and min. concentration of T-Hg in dorsal muscle of pjke was 0.2ppm in one year and 1.2ppm in five year class. The mean of T-Hg significantly increased with age and length increased (P<0.05).Mercury accumulation pattern in pike was as well as muscle > liver > spleen (P<0.05). THg content in female was higher than male(P<0.05). In contrast the mean of THg concentration in dorsal muscle of eigth fish species as prey was 0.282, 0.261, 0.328, 0.254, 0.256, 0.286, 0.322 and 0.241 ppm for Carassius auratus gibelio, Hemiculter leucisculus, Blicca bjoerkna transcaucasica, Chalcalburnus mossulensis, Rhodeus sericeus amarus, Gambusia holbrooki, Alburnus charusini hohenackeri & Scardinius Erythrophthalmus respectively.Liner regresion indicated that high degree of relationship between age of pike and Uptak/Intake ratio (R2=%99.12) and indicated that the mercury bioaccumulation in the pike dorsal muscle increased with age increased. BFA was >1 and and indicating the mercury biomagnification in the pike food chain. Trophy level of pike in the Anzali lagoon was estimated as well as 3.5 and 4 . It is generally agreed that Hg concentration in carnivorous fish are higher than in noncarnivorous species.
Resumo:
This paper presents an analytic expression for the acoustic eigenmodes of a cylindrical lined duct with rigid axially running splices in the presence of flow. The cylindrical duct is considered to be uniformly lined except for two symmetrically positioned axially running rigid liner splices. An exact analytic expression for the acoustic pressure eigenmodes is given in terms of an azimuthal Fourier sum, with the Fourier coefficients given by a recurrence relation. Since this expression is derived using a Greens function method, the completeness of the expansion is guaranteed. A numerical procedure is described for solving this recurrence relation, which is found to converge exponentially with respect to number of Fourier terms used and is in practice quick to compute; this is then used to give several numerical examples for both uniform and sheared mean flow. An asymptotic expression is derived to directly calculate the pressure eigenmodes for thin splices. This asymptotic expression is shown to be quantitatively accurate for ducts with very thin splices of less than 1 % unlined area and qualitatively helpful for thicker splices of the order of 6 % unlined area. A thin splice is in some cases shown to increase the damping of certain acoustic modes. The influences of thin splices and thin boundary layers are compared and found to be of comparable magnitude for the parameters considered. Trapped modes at the splices are also identified and investigated. © 2011 Cambridge University Press.
Resumo:
The present study aims at investigating the effect of a swirling mean flow and a lined annular duct on rotor trailing-edge noise. The objectives are to investigate these effects on the eigenvalues and a tailored Green's function on one hand and on the realistic case of the fan trailing-edge noise on the other hand. Indeed, the mean flow in between the rotor and the stator of the fan is highly swirling. Moreover, interstage liners are used to reduce the noise produced by the fan stage. The extension of Ffowcs-Williams & Hawkings' acoustic analogy in a medium at rest with moving surfaces, of Goldstein's acoustic analogy in a hardwall circular duct with uniform mean flow and of Rienstra & Tester's Green's function in an annular lined duct with uniform mean flow to a swirling mean flow in an annular duct with liner is introduced. First, the eigenvalues and the Green's function are investigated showing a strong effect of the swirl and of the liner. Second, a rotor trailing-edge noise model accounting for both the effects of the annular duct with lined walls and the swirling mean flow is developed and applied to a realistic fan rotor with different swirling mean flows (and as a result different associated blade stagger angles). The benchmark cases are built from the Boeing 18-inch Fan Rig Broadband Noise Test. In all cases the swirling mean flow has a strong effect on the absolute noise level. The overall liner insertion loss is little changed by the swirl in the studied cases.
Resumo:
This paper presents a method for trace level analysis of microcystins in water using solid-phase extraction and high performance liquid chromatography. The optimized condition enabled the determination of common microcystins at levels as low as 0.02 similar to 0.05 mug/L, and the liner range is from 0.1 mug/L to 50 mug/L. The method has been applied to the analysis of field sample from Dianchi lake.
Resumo:
Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e mu A of Xe37+, 1 e mu A of Xe43+, and 0.16 e mu A of Ne-like Xe44+. To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi31+ beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e mu A of Bi31+, 22 e mu A of Bi41+, and 1.5 e mu A of Bi50+ have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.
Resumo:
An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
A novel edge degree f(i) for heteroatom and multiple bonds in molecular graph is derived on the basis of the edge degree delta(e(r)). A novel edge connectivity index F-m is introduced. The multiple linear regression by using the edge connectivity index F-m and alcohol-type parameter delta, alcohol-distance parameter L can provide high-quality QSPR models for the normal boiling points (BPs), molar volumes (MVs), molar refraction (MRs), water solubility(log(1/S)) and octanol/water partition (logP) of alcohols with up to 17 non-hydrogen atoms. The results imply that these physical properties may be expressed as a liner combination of the edge connectivity index and alcohol-type parameter, 6, alcohol-distance parameter, L. For the models of the five properties, the correlation coefficient r and the standard errors are 0.9969,3.022; 0.9993, 1.504; 0.9992, 0.446; 0.9924,0.129 and 0.9973,0.123 for BPs, MVs, MRs, log(1/S) and logP, respectively. The cross-validation by using the leave-one-out method demonstrates the models to be highly reliable from the point of view of statistics.
Resumo:
The vesicle of didodecyldhnethylammonimn bromide (DDAB) which contained tetrathiafulvalene (TTF) was mixed with xanthine oxidase, and the mixture was cast on the pyrolytic graphite electrode. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. TTF was used as a mediator because of its high electron-transfer efficiency. A novel xanthine biosensor based on cast DDAB film was developed. The effects of pH and operating potential were explored for optimum analytical performance by using the amperometric method. The response time of the biosensor was less than 10 s. The detection limit of the biosensor was 3.2 x 10(-7) mol/L and the liner range was from 4 x 10(-7) mol/L to 2.4 x 10(-6) mol/L.
Resumo:
As a fast and effective method for approximate calculation of seismic numerical simulation, ray tracing method, which has important theory and practical application value, in terms of seismic theory and seismic simulation, inversion, migration, imaging, simplified from seismic theory according to geometric seismic, means that the main energy of seismic wave field propagates along ray paths in condition of high-frequency asymptotic approximation. Calculation of ray paths and traveltimes is one of key steps in seismic simulation, inversion, migration, and imaging. Integrated triangular grids layout on wavefront with wavefront reconstruction ray tracing method, the thesis puts forward wavefront reconstruction ray tracing method based on triangular grids layout on wavefront, achieves accurate and fast calculation of ray paths and traveltimes. This method has stable and reasonable ray distribution, and overcomes problems caused by shadows in conventional ray tracing methods. The application of triangular grids layout on wavefront, keeps all the triangular grids stable, and makes the division of grids and interpolation of a new ray convenient. This technology reduces grids and memory, and then improves calculation efficiency. It enhances calculation accuracy by accurate and effective description and division on wavefront. Ray tracing traveltime table, which shares the character of 2-D or 3-D scatter data, has great amount of data points in process of seismic simulation, inversion, migration, and imaging. Therefore the traveltime table file will be frequently read, and the calculation efficiency is very low. Due to these reasons, reasonable traveltime table compression will be very necessary. This thesis proposes surface fitting and scattered data compression with B-spline function method, applies to 2-D and 3-D traveltime table compression. In order to compress 2-D (3-D) traveltime table, first we need construct a smallest rectangular (cuboidal) region with regular grids to cover all the traveltime data points, through the coordinate range of them in 2-D surface (3-D space). Then the value of finite regular grids, which are stored in memory, can be calculated using least square method. The traveltime table can be decompressed when necessary, according to liner interpolation method of 2-D (3-D) B-spline function. In the above calculation, the coefficient matrix is stored using sparse method and the liner system equations are solved using LU decomposition based on the multi-frontal method according to the sparse character of the least square method matrix. This method is practiced successfully in several models, and the cubic B-spline function can be the best basal function for surface fitting. It make the construction surface smooth, has stable and effective compression with high approximate accuracy using regular grids. In this way, through constructing reasonable regular grids to insure the calculation efficiency and accuracy of compression and surface fitting, we achieved the aim of traveltime table compression. This greatly improves calculation efficiency in process of seismic simulation, inversion, migration, and imaging.