884 resultados para Linear accelerator
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.
Resumo:
A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed 241AmBe neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port.
Resumo:
Les néoplasies pulmonaires demeurent la première cause de décès par cancer au Québec représentant près de 6000 décès par année. Au cours des dernières années, la radiothérapie stéréotaxique d’ablation (SABR) s’est imposée comme un traitement alternatif à la résection anatomique pour les patients inopérables atteints d’un cancer pulmonaire non à petites cellules de stade précoce. Il s’agit d’une modalité de traitement qui permet d’administrer des doses élevées, typiquement 30-60 Gy en 1-8 fractions, dans le but de cibler précisément le volume de traitement tout en épargnant les tissus sains. Le Centre Hospitalier de l’Université de Montréal s’est muni en 2009 d’un appareil de SABR de fine pointe, le CyberKnife™ (CK), un accélérateur linéaire produisant un faisceau de photons de 6 MV dirigé par un bras robotisé, permettant d’administrer des traitements non-coplanaires avec une précision infra-millimétrique. Ce mémoire est dédié à la caractérisation de certains enjeux cliniques et physiques associés au traitement par CK. Il s’articule autour de deux articles scientifiques revus par les pairs. D’une part, une étude prospective clinique présentant les avantages de la SABR pulmonaire, une technique qui offre un excellent contrôle tumoral à long terme et aide au maintien de la qualité de vie et de la fonction pulmonaire. D’autre part, une étude de physique médicale illustrant les limites de l’acquisition d’images tomodensitométriques en auto-rétention respiratoire lors de la planification de traitement par CK.
Resumo:
AEC Contract AT(04-3)-400.
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-476."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"June 1964."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"AEC Contract AT(04-3)-400."