971 resultados para Layout. Offices. Workspaces. Environmental comfort
Resumo:
This paper presents results for thermal comfort assessment in non-uniform thermal environments. Three types of displacement ventilation (DV) units that created stratified condition in an environmental test chamber have been selected to carry out the thermal comfort assessment: a flat diffuser (DV1), semi-circular diffuser (DV2), and floor swirl diffuser (DV3). The CBE (Center for the Built Environment at Berkeley) comfort model was implemented in this study to assess the occupant’s thermal comfort for the three DV types. The CBE model predicted the occupant’s mean skin as well as local skin temperatures very well when compared with measurements found in the literature, while it underestimated the occupant’s core temperature. The predicted occupant’s thermal sensation and thermal comfort for the case of (DV2) were the best. Therefore, the semi-circular diffuser (DV2) provided better thermal comfort for the occupant in comparison with the other two DV types.
Resumo:
This paper investigates the extent to which office activity contributes to travel-related CO2 emission. Using ‘end-user’ figures[1], travel accounts for 32% of UK CO2 emission (Commission for Integrated Transport, 2007) and commuting and business travel accounts for a fifth of transport-related CO2 emissions, equating to 6.4% of total UK emissions (Building Research Establishment, 2000). Figures from the Department for Transport (2006) report that 70% of commuting trips were made by car, accounting for 73% of all commuting miles travelled. In assessing the environmental performance of an office building, the paper questions whether commuting and business travel-related CO2 emission is being properly assessed. For example, are office buildings in locations that are easily accessible by public transport being sufficiently rewarded? The de facto method for assessing the environmental performance of office buildings in the UK is the Building Research Establishment’s Environmental Assessment Method (BREEAM). Using data for Bristol, this paper examines firstly whether BREEAM places sufficient weight on travel-related CO2 emission in comparison with building operation-related CO2 emission, and secondly whether the methodology for assigning credits for travel-related CO2 emission efficiency is capable of discerning intra-urban differences in location such as city centre and out-of-town. The results show that, despite CO2 emission per worker from building operation and travel being comparable, there is a substantial difference in the credit-weighting allocated to each. Under the current version of BREEAM for offices, only a maximum of 4% of the available credits can be awarded for ensuring the office location is environmentally sustainable. The results also show that all locations within the established city centre of Bristol will receive maximum BREEAM credits. Given the parameters of the test there is little to distinguish one city centre location from another and out of town only one office location receives any credits. It would appear from these results that the assessment method is not able to discern subtle differences in the sustainability of office locations
Resumo:
The adaptive thermal comfort theory considers people as active rather than passive recipients in response to ambient physical thermal stimuli, in contrast with conventional, heat-balance-based, thermal comfort theory. Occupants actively interact with the environments they occupy by means of utilizing adaptations in terms of physiological, behavioural and psychological dimensions to achieve ‘real world’ thermal comfort. This paper introduces a method of quantifying the physiological, behavioural and psychological portions of the adaptation process by using the analytic hierarchy process (AHP) based on the case studies conducted in the UK and China. Apart from three categories of adaptations which are viewed as criteria, six possible alternatives are considered: physiological indices/health status, the indoor environment, the outdoor environment, personal physical factors, environmental control and thermal expectation. With the AHP technique, all the above-mentioned criteria, factors and corresponding elements are arranged in a hierarchy tree and quantified by using a series of pair-wise judgements. A sensitivity analysis is carried out to improve the quality of these results. The proposed quantitative weighting method provides researchers with opportunities to better understand the adaptive mechanisms and reveal the significance of each category for the achievement of adaptive thermal comfort.
Resumo:
This paper fully describes a nation-wide field study on building thermal environment and thermal comfort of occupant, which was carried out in summer 2005 and in winter 2006 respectively in China, illustrating the adaptive strategies adopted by occupants in domestic buildings in China. According to the climate division in China, the buildings in Beijing (BJ), Shanghai (SH), Wuhan (WH) and Chongqing (CQ), Guangzhou (GZ), Kunming (KM), were selected as targets which are corresponding to cold zone, hot summer and cold winter zone (SWC-SH, WH, CQ), hot summer and warm winter zone and temperate zone, respectively. The methodology used in the field study is the combination of subjective questionnaire regarding thermal sensation and adaptive approaches and physical environmental monitoring including indoor air temperature and relative humidity. A total of 1671 subjects participate in this investigation with more than 80% response rate in all surveyed cities. Both physiological and non-physiological factors (behavioural and psychological adaptations) have been analysed.
Resumo:
Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.
Resumo:
The built environment in China is required to achieve a 50% reduction in carbon emissions by 2020 against the 1980 design standard. A particular challenge is how to maintain acceptable comfort conditions through the hot humid summers and cold desiccating winters of its continental climate regions. Fully air-conditioned sealed envelopes, often fully glazed, are becoming increasingly common in these regions. Remedial strategies involve technical refinements to the air-handling equipment and a contribution from renewable energy sources in an attempt to achieve the prescribed net reduction in energy use. However an alternative hybrid environmental design strategy is developed in this research project. It exploits observed temperate periods of weeks, days, even hours in duration to free-run an office and exhibition building configured to promote natural stack ventilation when ambient conditions permit and mechanical ventilation when conditions require it, the two modes delivered through the same physical infrastructure. The proposal is modelled in proprietary software and the methodology adopted is described. The challenge is compounded by its first practical application to an existing reinforced concrete frame originally designed to receive a highly glazed envelope. This original scheme is reviewed in comparison. Furthermore the practical delivery of the proposal value engineered out a proportion of the ventilation stacks. The likely consequence of this for the environmental performance of the building is investigated through a sensitivity study.
Resumo:
‘Sustainable’ or ‘green’ commercial buildings are frequently seen as a growth sector in the property investment market. This research examines the emergence of sustainable commercial buildings in both the UK and overseas. The empirical part of the paper is based on a telephone survey of 50 UK corporate (private sector) occupiers taking leased and owner–occupied office space, which was carried out during the period of April to November 2008. The survey focused on actual moves made within the previous two years, or moves that were imminent during 2006–2008. The research suggests that although there is an emerging and increasing demand for sustainable offices in the UK, other factors such as location and availability of stock continue to remain more important than sustainability in determining occupiers’ final choice of office. Occupiers who moved to a Building Research Establishment Environmental Assessment Method (BREEAM)‐rated building, and were in business sectors with strong environmental and corporate responsibility policies, placed more emphasis on sustainability than other groups in the final choice of office, but location and availability remained paramount.
Resumo:
As the fidelity of virtual environments (VE) continues to increase, the possibility of using them as training platforms is becoming increasingly realistic for a variety of application domains, including military and emergency personnel training. In the past, there was much debate on whether the acquisition and subsequent transfer of spatial knowledge from VEs to the real world is possible, or whether the differences in medium during training would essentially be an obstacle to truly learning geometric space. In this paper, the authors present various cognitive and environmental factors that not only contribute to this process, but also interact with each other to a certain degree, leading to a variable exposure time requirement in order for the process of spatial knowledge acquisition (SKA) to occur. The cognitive factors that the authors discuss include a variety of individual user differences such as: knowledge and experience; cognitive gender differences; aptitude and spatial orientation skill; and finally, cognitive styles. Environmental factors discussed include: Size, Spatial layout complexity and landmark distribution. It may seem obvious that since every individual's brain is unique - not only through experience, but also through genetic predisposition that a one size fits all approach to training would be illogical. Furthermore, considering that various cognitive differences may further emerge when a certain stimulus is present (e.g. complex environmental space), it would make even more sense to understand how these factors can impact spatial memory, and to try to adapt the training session by providing visual/auditory cues as well as by changing the exposure time requirements for each individual. The impact of this research domain is important to VE training in general, however within service and military domains, guaranteeing appropriate spatial training is critical in order to ensure that disorientation does not occur in a life or death scenario.
Resumo:
Improving the environmental performance of non-domestic buildings is a complex and ‘wicked’ problem due to conflicting interests and incentives. This is particularly challenging in tenanted spaces, where landlord and tenant interactions are regulated through leases that traditionally ignore environmental considerations. ‘Green leasing’ is conceptualized as a form of ‘middle-out’ inter-organizational environmental governance that operates between organizations, alongside other drivers. This paper investigates how leases are evolving to become ‘greener’ in the UK and Australia, providing evidence from five varied sources on: (1) UK office and retail leases, (2) UK retail sector energy management, (3) a major UK retailer case study; (4) office leasing in Sydney, and (5) expert interviews on Australian retail leases. With some exceptions, the evidence reveals an increasing trend towards green leases in prime offices in both countries, but not in retail or sub-prime offices. Generally introduced by landlords, adopted green leases contain a variety of ambitions and levels of enforcement. As an evolving form of private–private environmental governance, green leases form a valuable framework for further tenant–landlord cooperation within properties and across portfolios. This increased cohesion could create new opportunities for polycentric governance, particularly at the interface of cities and the property industry.
Resumo:
The objective of this work was to evaluate the effect of environmental variables on dairy buffaloes physiology in two different places after milking, shaded plus artificial ventilation and another one non-shaded, in Ribeira Valley, São Paulo State, Brazil. Data on the respiratory rate (RR) and the surface temperature (ST) at udder, neckmiddle, forehead, back middle and rump were collected in 12 dairy buffaloes at autumn. In the same way, it were recorded the black globe temperature in the sun (GTS) and in the shade (GTNS), air temperature and wind speed at padronized height of 1.60 meters. All data were collected at 10:30am and 1:30pm. The results showed statistical difference among black globe temperature, wind speed, RR and ST (P<0.01) in two treatments.The results showed the necessity of protection against the solar radiation in the buffaloes, even in periods of warm climates.
Resumo:
Layer mortality due to heat stress is an important economic loss for the producer. The aim of this study was to determine the mortality pattern of layers reared in the region of Bastos, SP, Brazil, according to external environment and bird age. Data mining technique were used based on monthly mortality records of hens in production, 135 poultry houses, from January 2004 to August 2008. The external environment was characterized according maximum and minimum temperatures, obtained monthly at the meteorological station CATI in the city of Tupa, SP, Brazil. Mortality was classified as normal (<= 1.2%) or high (> 1.2%), considering the mortality limits mentioned in literature. Data mining technique produced a decision tree with nine levels and 23 leaves, with 62.6% of overall accuracy. The hit rate for the High class was 64.1% and 59.9% for Normal class. The decision tree allowed finding a pattern in the mortality data, generating a model for estimating mortality based on the thermal environment and bird age.
Resumo:
Pigs are quite sensitive to high environmental temperatures and the thermoregulation mechanisms represent great expenses in energy for heating loss, reducing animal well-being and production performance, and altering carcass quality. The aim of this study was to assess the effects of sex and dietary energy level in growing-finishing pigs submitted to characteristic seasonal variation of temperature in subtropical humid climate, and to propose a mathematical model to predict growth performance and carcass characteristics. Twenty-eight crossbred growing-finishing pigs were randomly allotted to twelve treatments, in a 2x2x3 factorial trial (2 sex; 2 environmental conditions, and 3 energy levels). Heat stress condition (climatic chamber) showed temperatures of 31 oC at 7:00 and 22 oC at 17:00 (maximum of 33 °C) and thermal comfort condition (stall) showed temperatures of 18 °C at 7:00 and 24 °C (maximum of 27 °C). Pigs were fed ad libitum with diets containing 12.2 (low), 13.6 (medium) and 15.0 (high) MJ ME/ kg DM. Voluntary feed intake, daily weight gain, and final body weight were higher (P<0.01) at thermal comfort condition and were influenced by sex (P<0.01) in growing pigs. Feed to gain ratio decreased as the energy level increased (P<0.01), with values of 2.67, 2.59, and 2.32 (12.2, 13.6, and 15.0 MJ ME/kg DM, respectively). There was energy level and sex interaction only for daily weight gain. Regarding finishing pigs, environmental conditions also showed effects (P<0.01) on voluntary feed intake, daily weight gain, and final body weight. Performance of pigs was better at thermal comfort condition. Feed to gain ratio values were 3.55, 3.42, and 2.95 for low, medium, and high energy level, respectively. Interactions between energy level and sex were observed for voluntary feed intake, daily weight gain, and final body weight (P<0.05). Carcass yield and quality were affected by environmental condition and dietary energy level. Both hot and cold carcass weight increased as energy of ration increased. Cold carcass weight increased by 1.142 kg/MJ EM whereas backfat thickness was up to 252 mm/MJ EM. Longissimus thoracis muscle thickness was around 16 mm smaller in pigs under heat stress, but lean content was 2.68% higher in those animals. Regression equations were proposed to predict the performance values in the different situations studied.
Resumo:
Includes bibliography
Resumo:
Statistical organizations of the Caribbean countries continue to face serious challenges posed by the increased demand for more relevant, accurate and timely statistical data. Tangible progress has been made in delivering key products in the area of economic statistics. The central banks of the subregion have assisted greatly in this respect. However, even in this branch of statistics there are still several glaring gaps. The situation is even worse in other areas of statistics including social and environmental statistics. Even though all countries of the subregion have committed to the Millennium Development Goals (MDGs) as well as to other internationally agreed development goals serious challenges remain with respect to the compilation of the agreed indicators to assist in assessing progress towards the goals. It is acknowledged that appreciable assistance has been provided by the various donor agencies to develop statistical competence. This assistance has translated into the many gains that have been made. However, the national statistical organizations require much more help if they are to reach the plateau of self reliance in the production of the necessary statistical services. The governments of the subregion have also committed to invest more in statistical development and in promoting a statistics culture in the Caribbean. The training institutions of the subregion have also started to address this urgent need by broadening and deepening their teaching curricula. Funding support is urgently required to develop the appropriate cadre of statistical professionals to deliver the required outputs. However, this training must be continuous and must be sustained over an appropriate period since the current turnover of trained staff is high. This programme of training will need to be intensive for a period of at least five years after which it may be reduced. The modalities of training will also have to be more focused and in addition to formal training at educational institutions there is much room for on-the-job training, group training at the national level and much more south-south capacity building. There is also an urgent need to strengthen cooperation and collaboration among the donor community in the delivery of assistance for statistical development. Several development agencies with very good intentions are currently operating in the Caribbean. There is a danger however, that efforts can be duplicated if agencies do not collaborate adequately. Development agencies therefore need to consult with each other much more and share there development agenda more freely if duplication is to be averted. Moreover, the pooling of resources can surely maximize the benefits to the countries of the subregion.
Resumo:
This study aims at identifying which environmental management practices computer companies located in Brazil are adopting, and classifying these companies according to the evolutionary stages of environmental management. For such, the case study research method was used at three companies. Results show that environmental management in the sector is geared towards compliance with laws and eco-efficiency, aimed at cutting costs. It was concluded that classification does not occur in a linear manner with defined borders, and that the multinational companies located in Brazil are greatly influenced by their foreign head offices, which are at more advanced evolutionary stages.