951 resultados para Laser treatment


Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of CO2 laser treatment through topically applied amine fluoride solution on demineralised enamel. MATERIALS AND METHODS: Sixty extracted human molar crowns were selected and cut longitudinally into half. One half was subjected to a 10-day pH-cycling procedure to create caries-like lesions, whereas the other was left non-demineralised. The following treatments were randomly assigned (one treatment per tooth, on respective non-demineralised and demineralised matched specimens): exposure to a 1% amine fluoride solution for 15 s without irradiation (group I), irradiation for 15 s with a continuous-wave CO2 laser (group II), or laser-treatment for 15 s through the amine fluoride solution applied immediately beforehand (group III). Fluoride uptake (n = 30) and acid resistance (n = 30) were determined after treatment. Enamel surface alterations after laser irradiation were monitored using scanning electron microscopy. RESULTS: In groups I and III, an increased fluoride uptake was detected (p < or = 0.05). Laser irradiation through topical fluoride resulted in an increased acid resistance of sound and demineralised enamel specimens in deeper layers (p < or = 0.05). In addition, less surface alterations were observed in SEM examination of specimens irradiated through the amine fluoride solution compared with counterparts treated with laser only. CONCLUSIONS: CO2 laser light application through an amine fluoride solution may be instrumental in enhancing acid resistance of sound and demineralised enamel.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE To systematically review the current literature on the maxillary midline frenum and associated conditions and complications, as well as the recommended treatment options. METHOD AND MATERIALS A detailed MEDLINE database search was carried out to provide evidence about the epidemiology, associated pathologies, and treatment options regarding the maxillary frenum. Of the 206 initially identified articles, 48 met the inclusion criteria. RESULTS The maxillary frenum is highly associated with a number of syndromes and developmental abnormalities. A hypertrophic frenum may be involved in the etiology of the midline diastema. There is also a tendency by orthodontists to suggest posttreatment removal of the frenum (frenectomy). Studies on the cause of gingival recession due to the maxillary frenum are inconclusive. An injured frenum in combination with other traumas and doubtful history might point to child abuse. The involvement of hyperplastic frena in the pathogenesis of peri-implant diseases remains uncertain. There seems to be a clinical interest regarding lasers for surgery for treatment of maxillary frena. The superiority of laser treatment in relation to conventional surgical methods has not yet been demonstrated in the literature. CONCLUSION A maxillary frenum is a clinical symptom in numerous syndromic conditions and plays a role in the development of the median midline diastema. Nevertheless, the contribution to gingival recession and peri-implant diseases in the region of the maxillary incisors is rather controversial. Laser techniques are reported as the method of choice for the surgical removal of frena; however, this needs to be substantiated by appropriate prospective controlled studies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Fractured endodontic instruments inhibit optimal cleaning and filling of dental root canals, which may result in a less favorable prognosis for the tooth. Several techniques are available to remove fractured instruments; however, healthy tooth substance often must be destroyed in the process. This study was intended to evaluate Nd:YAG laser treatment as a method to remove fractured stainless steel instruments without destroying healthy tooth substance. METHOD AND MATERIALS Stainless steel endodontic instruments were fractured in 33 unprocessed root canals of mandibular central and lateral incisors and premolars in vitro. A brass tube charged with solder was placed at the coronal end of the fractured instrument and laser energy was used to melt the solder, connecting the fractured instrument with the brass tube. The success rates of connecting and removal of fractured instruments from the root channel were recorded for each case. RESULTS Connecting was achieved in every case in which more than 1.5 mm of the fractured instrument was tangible (22 out of 22). In cases where less than 1.5 mm was tangible, the rate for successful connection decreased to 4 out of 11 (36.4%). Fractured endodontic instruments were removed successfully in 17 out of 22 cases (77.3%) in which more than 1.5 mm was tangible. If less than 1.5 mm was tangible, the removal success rate decreased to 3 out of 11 cases (27.3%). CONCLUSION Our data support Nd:YAG laser-mediated connecting of a brass tube to a fractured endodontic instrument as a feasible and tissue conserving removal approach when more than 1.5 mm of the instrument is tangible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O presente estudo avaliou a velocidade da movimentação ortodôntica e as alterações dentárias e esqueléticas na distalização de molares superiores sob influência do laser de baixa intensidade por meio de telerradiografias laterais. A amostra foi constituída por 18 pacientes, portadores de maloclusão Classe II, com idade média inicial de 14,4 anos e divididos em dois grupos: Grupo I - laser e Grupo II - controle. Os pacientes foram tratados com um dispositivo ortodôntico denominado Pêndulo de Hilgers modificado, concomitantemente foi realizado a aplicação do laser de baixa intensidade na região radicular dos primeiros e segundos molares superiores, dos lados direito e esquerdo, nos pacientes do grupo I, sob o seguinte protocolo: 780nm de comprimento de onda, 40mW de potência, 10J/cm² de densidade de energia, 0,4J de energia por ponto durante 10 segundos cada e resultando em energia total de 20,8J. Foram distribuídos 52 pontos por vestibular e palatina dos primeiros e segundos molares superiores. A aplicação do laser foi realizada no dia da ativação da mola de TMA e repetida a cada mês até a sobrecorreção da relação molar. As telerradiografias laterais foram realizadas no início do tratamento (T1), ao final do terceiro mês (T2) e ao final da distalização (T3) com a relação molar sobrecorrigida em aproximadamente 1mm. Após análise cefalométrica foram realizadas comparações das alterações obtidas entre as fases Inicial (T1) e Final (T3) e Inicial (T1) e terceiro mês (T2) e comparadas entre os grupos. Os resultados mostraram inclinação para distal dos primeiros e segundos molares superiores, inclinação vestibular dos incisivos centrais superiores acentuada pela presença dos segundos molares e ausência de alterações dentárias verticais significativas, rotação do plano mandibular no sentido horário e o consequente aumento da altura facial anterior inferior. Concluiu-se que os efeitos do Pêndulo de Hilgers modificado sob a metodologia realizada provocaram alterações predominantemente dentoalveolares e que a movimentação dos primeiros e segundos molares superiores sob efeito da laserterapia, não apresentou diferença estatisticamente significante na velocidade de movimentação ortodôntica e em nenhuma das variáveis estudadas.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Presentation Purpose:We conducted a study to determine if the spectral domain optical coherence tomography (SD-OCT) could be used as a tool to assess effective delivery of threshold and subthreshold laser burns created using 532nm green wavelength laser. Methods:10 patients planned for panretinal photocoagulation (PRP) for proliferative diabetic retinopathy were included in this study. Before initiating the full PRP, a row of moderately white laser burns as used for conventional PRP was created using 532 nm laser set at threshold power for 0.1 second with 300 microns spot size. Further rows of laser burns were created by altering the duration and power settings on the laser device. The area of the retina irradiated with laser was imaged using the Topcon SD-OCT within a few minutes of laser treatment. Results:Laser burns created using threshold power were seen on the OCT scan in all cases as a homogenous diffuse increase in reflectivity extending across the full thickness of retina (Fig 1). Retinal burns created by lowering the duration of laser pulse to 0.01s were barely visible ophthalmoscopically but were clearly detectable on the OCT scan as a localised, well-defined area of increased tissue reflectivity (Fig 2). Conclusions:OCT is a useful to tool to assess the delivery of laser burns created using the 532 nm green laser. Burns of a subthreshold intensity that may not be visible ophthalmoscopically result in retinal changes that are clearly detectable on OCT imaging. Further studies would be needed to assess the clinical effectiveness of subthreshold laser treatment for retinal vascular diseases using the 532 nm green laser.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: Current panretinal laser photocoagulative parameters are based on the Diabetic Retinopathy Study, which used exposures of 0.1 - 0.5 second to achieve moderate intensity retinal burns. Unfortunately, many patients find these settings painful. We wanted to investigate whether reducing exposure time and increasing power to give the same endpoint, is more comfortable and effective. Methods: 20 patients having panretinal photocoagulation for the first time underwent random allocation to two forms of laser treatment: half of the retinal area scheduled for treatment was treated with Green Yag laser with conventional parameters {exposure time 0.1 second (treatment A), power density sufficient to produce a visible grey - white burns}. The other half treated with shorter exposure 0.02 second (treatment B). All patient were asked to evaluate severity of pain on a visual analogue scale ranging from 0 - 10 (0 = no pain, 10 = most severe pain). All patients were masked as to the type of treatment. The order of carrying out the treatment on each patient was randomised. Fundus photographs were taken of each hemifundus to confirm treatment. Results: Of the 20 patients, 17 had proliferative diabetic retinopathy, 2 had ischaemic central retinal vein occlusion and one had ocular ischaemic syndrome. The average pain response to treatment A was 5.11 on a visual analogue scale with a mean power of 0.178 Watt; the average pain response to treatment B was 1.40 with a mean power of 0.489 Watt. Short exposure laser burns were significantly less painful (P < 0.001). Conclusion: Shortening exposure time with increased power is more comfortable for patients undergoing panretinal photocoagulation than conventional parameters.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract PURPOSE: To evaluate ranibizumab 0.5 mg using bimonthly monitoring and individualized re-treatment after monthly follow-up for 6 months in patients with visual impairment due to diabetic macular edema (DME). DESIGN: A phase IIIb, 18-month, prospective, open-label, multicenter, single-arm study in the United Kingdom. PARTICIPANTS: Participants (N = 109) with visual impairment due to DME. METHODS: Participants received 3 initial monthly ranibizumab 0.5 mg injections (day 0 to month 2), followed by individualized best-corrected visual acuity (BCVA) and optical coherence tomography-guided re-treatment with monthly (months 3-5) and subsequent bimonthly follow-up (months 6-18). Laser was allowed after month 6. MAIN OUTCOME MEASURES: Mean change in BCVA from baseline to month 12 (primary end point), mean change in BCVA and central retinal thickness (CRT) from baseline to month 18, gain of ≥10 and ≥15 letters, treatment exposure, and incidence of adverse events over 18 months. RESULTS: Of 109 participants, 100 (91.7%) and 99 (90.8%) completed the 12 and 18 months of the study, respectively. The mean age was 63.7 years, the mean duration of DME was 40 months, and 77.1% of the participants had received prior laser treatment (study eye). At baseline, mean BCVA was 62.9 letters, 20% of patients had a baseline BCVA of >73 letters, and mean baseline CRT was 418.1 μm, with 32% of patients having a baseline CRT <300 μm. The mean change in BCVA from baseline to month 6 was +6.6 letters (95% confidence interval [CI], 4.9-8.3), and after institution of bimonthly treatment the mean change in BCVA at month 12 was +4.8 letters (95% CI, 2.9-6.7; P < 0.001) and +6.5 letters (95% CI, 4.2-8.8) at month 18. The proportion of participants gaining ≥10 and ≥15 letters was 24.8% and 13.8% at month 12 and 34.9% and 19.3% at month 18, respectively. Participants received a mean of 6.8 and 8.5 injections over 12 and 18 months, respectively. No new ocular or nonocular safety findings were observed during the study. CONCLUSIONS: The BCVA gain achieved in the initial 6-month treatment period was maintained with an additional 12 months of bimonthly ranibizumab PRN treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conventional invasive coronary angiography is the clinical gold standard for detecting of coronary artery stenoses. Noninvasive multidetector computed tomography (MDCT) in combination with retrospective ECG gating has recently been shown to permit visualization of the coronary artery lumen and detection of coronary artery stenoses. Single photon emission tomography (SPECT) perfusion imaging has been considered the reference method for evaluation of nonviable myocardium, but magnetic resonance imaging (MRI) can accurately depict structure, function, effusion, and myocardial viability, with an overall capacity unmatched by any other single imaging modality. Magnetocardiography (MCG) provides noninvasively information about myocardial excitation propagation and repolarization without the use of electrodes. This evolving technique may be considered the magnetic equivalent to electrocardiography. The aim of the present series of studies was to evaluate changes in the myocardium assessed with SPECT and MRI caused by coronary artery disease, examine the capability of multidetector computed tomography coronary angiography (MDCT-CA) to detect significant stenoses in the coronary arteries, and MCG to assess remote myocardial infarctions. Our study showed that in severe, progressing coronary artery disease laser treatment does not improve global left ventricular function or myocardial perfusion, but it does preserve systolic wall thickening in fixed defects (scar). It also prevents changes from ischemic myocardial regions to scar. The MCG repolarization variables are informative in remote myocardial infarction, and may perform as well as the conventional QRS criteria in detection of healed myocardial infarction. These STT abnormalities are more pronounced in patients with Q-wave infarction than in patients with non-Q-wave infarctions. MDCT-CA had a sensitivity of 82%, a specificity of 94%, a positive predictive value of 79%, and a negative predictive value of 95% for stenoses over 50% in the main coronary arteries as compared with conventional coronary angiography in patients with known coronary artery disease. Left ventricular wall dysfunction, perfusion defects, and infarctions were detected in 50-78% of sectors assigned to calcifications or stenoses, but also in sectors supplied by normally perfused coronary arteries. Our study showed a low sensitivity (sensitivity 63%) in detecting obstructive coronary artery disease assessed by MDCT in patients with severe aortic stenosis. Massive calcifications complicated correct assessment of the lumen of coronary arteries.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

通过有限元方法,模拟了接触载荷下,激光熔覆盖率对材料表层循环应力幅值和表层裂纹CTOD的影响,从而预测了熔凝覆盖率对材料接触疲劳寿命的影响。文中考虑了不同熔凝覆盖率的材料表面微结构形状的差异,不同熔凝覆盖率摩擦副的摩擦系数一样和发生变化两种情况。结果显示,熔凝覆盖率为20%左右的材料表层强韧化性能最好。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

采用焓方法对Nd:YAG脉冲激光导致的不锈钢材料表面熔凝过程的温度场进行了数值模拟.在此基础上,结合材料的结晶动力学和快速凝固理论,对材料微结构演化的几个重要参数,包括凝固速率、冷却速度和界面温度梯度做了估算和讨论.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

采用无粘胶膜层结合力测试方法对镀铬层的结合性能进行定量测试.结果表明,钢基体经高重频激光强化处理改善了原基体状态铬层断面的瓷状形貌,断面粗糙,抗破坏能力提高.对两种状态铬层的破坏抗力差异和端面形貌特征的形成原因进行了分析.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los diferentes tipos de láseres, sobre todo el láser de diodo, irrumpen en la terapéutica podológica para proporcionar una alternativa más de tratamiento en muchas patologías que son el día a día de las consultas. El buen manejo y el conocimiento de sus características son requisitos imprescindibles para no tener efectos secundarios indeseados y poder llevar a cabo tratamientos poco dolorosos, minimizando el tiempo total, y muchas veces proporcionando una solución a diversas patologías.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

When TiO2 powder was irradiated with a laser light (>0.8 MW peak pulse power (PPP) at 355 nm) a visible change in its colour from white to dark blue was observed. The initial rate of change of the total colour difference was related to the laser light intensity and the longer the irradiation time the more substantial the colour change. The result of X-ray diffraction (XRD) studies showed that the crystal structure of the TiO2 developed a more rutile form after laser exposure. ESR studies indicated that the colour change was associated with the generation of Ti(III) species in the photocatalyst. Electron microscopic studies showed that more spherical shaped particles of TiO2 were observed after laser treatment although the average particle size remained largely unchanged. No significant changes in the band gap or the surface area of the laser modified TiO2 were observed. The laser modified photocatalyst showed no enhancement in activity for the destruction of methylene blue, rhodamine B and stearic acids, indicating that the rutile/anatase ratio is unimportant in the destruction of the test pollutants used in this work, via TiO2 photocatalysis

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of high power pulsed laser light on a TiO2 photocatalyst (powder and 0.1% (w/v) aqueous suspension) are reported. When this material was irradiated with a laser of power over 0.8 MW peak pulse power at 355 nm wavelength a visible change in colour from white to dark blue was observed. The initial rate of change of the total colour difference is related to the laser power; the stronger the laser power the darker the colour change. The result of X-ray diffraction studies indicates that the crystal structure of the TiO2 developed a more rutile form after laser exposure. Electron microscopic studies showed that spherical shaped particles of TiO2 were observed after laser treatment. Preliminary results show enhanced photocatalytic activity for the destruction of methylene blue. (C) 1999 Elsevier Science S.A. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim - To describe a new surgical technique for foveal relocation, and to report the outcome in nine patients treated with this procedure. Methods - Nine consecutive patients with subfoveal choroidal neovascular membranes (CNVMs) secondary to age related macular degeneration underwent foveal relocation surgery by redistribution of the neurosensory retina (RNR). The technique involved induction of a retinal detachment via a single retinotomy, relocation of the fovea by 'sweeping' the retinal tissue with a retinal brush, and stabilisation of the retina in its new location using perfluorocarbon liquid peroperatively and silicone oil postoperatively. Results - In eight of nine eyes successful relocation of the fovea was achieved; in one eye the CNVM remained in a subfoveal location postoperatively. Visual acuity improved in two eyes, remained unchanged in three, and decreased in four eyes after a median follow up of 4 months (range 2.5-6 months). Complications included rupture of a foveal cyst with the development of a macular hole in one eye and epimacular membrane formation in another eye. In two eyes, macular retinal vessel closure occurred at the time of laser photocoagulation; one of these eyes later developed cystoid macular oedema and the other an epiretinal membrane. Recurrence of the CNVM was observed in one eye, but was controlled with further laser treatment. Conclusions - Foveal relocation by RNR appears to be feasible, obviating the need for extensive retinotomies or scleral shortening.