884 resultados para Laser refractive surgery
Resumo:
Purpose: To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Setting: Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Design: Comparative evaluation of diagnostic technology. Methods: Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. Results: The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Conclusion: Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.
Resumo:
Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.
Corneal complications associated with topical ophthalmic use of nonsteroidal antiinflammatory drugs.
Resumo:
PURPOSE:
To explore the potential association between adverse corneal events and the use of topical nonsteroidal antiinflammatory drugs (NSAIDs).
SETTING:
Practice-based reports.
METHODS:
A detailed case-reporting form and request for medical records were sent to all practices reporting cases of corneal or conjunctival pathology in association with the use of topical NSAIDs to the American Society of Cataract and Refractive Surgery. Cases were classified as "mild," "moderate," or "severe" according to predetermined clinical criteria.
RESULTS:
Records of 140 eyes (129 patients) were reviewed; 51 cases (36.4%) were mild, 55 (39.3%) moderate, and 34 (24.3%) severe. An association with a specific topical NSAID was confirmed in 117 cases (81.8%). Most confirmed cases (53.8%) involved generic diclofenac (Falcon). Cases associated with brand diclofenac (Voltaren, CIBA Vision) and ketorolac (Acular, Allergan) were more likely to have ocular comorbidity and to have received significantly higher total doses of NSAIDs. Neither "off-label" use nor use of any specific agent was associated with severe compared to mild or moderate disease. However, patients with more severe adverse events were more likely to have a history of diabetes, previous surgery in the affected eye, and surgery other than cataract. Cases not occurring in the perioperative period had significantly worse outcomes, had significantly more ocular comorbidities, and received nearly 3 times the dose of NSAIDs.
CONCLUSIONS:
While topical NSAIDs as a class may be associated with severe adverse events, such events appeared to require potentiation in the form of high total doses, ocular comorbidities, or both with Acular and Voltaren. Severe adverse events might have been more likely to occur at lower doses and in routine postoperative settings with generic diclofenac.
Resumo:
PURPOSE: To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). SETTING: The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. RESULTS: The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). CONCLUSIONS: Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.
Resumo:
PURPOSE:
To report determinants of outcomes and follow-up in a large Mexican pediatric cataract project.
SETTING:
Hospital Luis Sanchez Bulnes, Mexico City, Mexico.
METHODS:
Data were collected prospectively from a pediatric cataract surgery program at the Hospital Luis Sanchez Bulnes, implemented by Helen Keller International. Preoperative data included age, sex, baseline visual acuity, type of cataract, laterality, and presence of conditions such as amblyopia. Surgical data included vitrectomy, capsulotomy, complications, and use of intraocular lenses (IOLs). Postoperative data included final visual acuity, refraction, number of follow-up visits, and program support for follow-up.
RESULTS:
Of 574 eyes of 415 children (mean age 7.1 years +/- 4.7 [SD]), IOLs were placed in 416 (87%). At least 1 follow-up was attended by 408 patients (98.3%) (mean total follow-up 3.5 +/- 1.8 months); 40% of eyes achieved a final visual acuity of 6/18 or better. Children living farther from the hospital had fewer postoperative visits (P = .04), while children receiving program support had more visits (P = .001). Factors predictive of better acuity included receiving an IOL during surgery (P = .04) and provision of postoperative spectacles (P = .001). Predictive of worse acuity were amblyopia (P = .003), postoperative complications (P = .0001), unilateral surgery (P = .0075), and female sex (P = .045).
CONCLUSIONS:
The results underscore the importance of surgical training in reducing complications, early intervention before amblyopia (observed in 40% of patients) can develop, and vigorous treatment if amblyopia is present. The positive impact of program support on follow-up is encouraging, although direct financial support may pose a problem for sustainability. More work is needed to understand reasons for worse outcomes in girls.
Resumo:
PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.
Resumo:
Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.
Resumo:
Introducción: Los resultados de la remoción de tatuajes con láser de sesión a sesión según los parámetros utilizados son limitados en la literatura. Objetivo: Evaluar los cambios en el aclaramiento de tatuajes y factores asociados posterior a una sesión con láser y los efectos adversos. Materiales y Métodos: Estudio longitudinal retrospectivo de antes y después de 1 sesión de con láser para remoción de tatuajes, donde se determinaron parámetros del tratamiento, aclaramiento y efectos adversos. Resultados: Se evaluaron 35 pacientes para un total de 98 sesiones, fototipo de piel II y IV. Equipos utilizados laser Q-Switch Nd Yag 1064 (83.3%), láser Q-Switch Nd YAG 532(11.3%) y laser Q-Switch Rubí (4.1%). El aclaramiento posterior a la sesión de láser fue evaluado por dos evaluadores independientes, mostrando concordancia significativa (Kappa de 0.615, p<0.001), con aclaración en un 96% de los tatuajes después de la sesión de láser. (p< 0.001). Se encontraron cambios significativos entre la densidad de energía aplicada y las categorías de aclaramiento de la escala de 0 a 3, siendo a mayor densidad mayor el nivel de aclaramiento (p= 0.05). No se encontró asociación significativa entre el número de pases y el aclaramiento del tatuaje. Los efectos adversos fueron del 5.4%. Cicatriz 2%, hiperpigmentación 2% y hipopigmentación 1%. Conclusión: Posterior a una sesión de remoción de tatuajes con láser Q-Switch hay un aclaramiento significativo en un 96% asociado con la densidad de energía, a mayor densidad de energía mayor el nivel de aclaramiento y no al número de pases realizados.
Resumo:
Several experiments (time-resolved Z-scan experiments based on pulsed and CW pump lasers, time-resolved divergence diagnostics) have been performed to examine and clarify the question of the converging or diverging population lensing effect occurring in a Cr(3+):Al(2)O(3) ruby laser. The dynamics of the laser far-field divergence of such a laser indeed indicated initially a diverging effect while Z-scan measurements conclude to a converging one. The origin of this discrepancy is thus analysed and elucidated here by introducing the general concept of correlation collapse between the centre and the wings of a laser beam having some clipping. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The topical corneal application of antimitotic mitomycin-C (MMC) during refractive surgery is still characterized by a lack of standardization and considerable empirism. For this reason the creation of a system capable of reliable drug delivery represents a beneficial innovation for patients submitted to these procedures. Objective: Elaborate a new MMC delivery system during the transoperatory period of photorefractive keratectomy (PRK) followed by patent application. Methods: The project consists of an in vitro experimental study to create an MMC (0.02%) release system. The drug was impregnated in sterile Whatman® 41 paper filter discs with a diameter of 8 mm. After drying, the discs were applied to antibiogram plates seeded with Staphylococcus epidermidis (American Type Culture Collection ATCC 12228), followed by the addition of a drop of sterile water. At the end of 1 minute, the discs were removed and the plates incubated for 48 hours at 35oC. Mean drop volume in the collyrium flasks was measured using analytical balance weighing. The inhibition halo (mm) was correlated with the MMC impregnated into the disc. After completion of the invention design a patent application was lodged at the National Institute of Industrial Property. Results: The correspondence between MMC-produced inhibition halos indicated that a dose of 16μg was ideal for impregnating into the discs. The mean drop volume obtained from the collyrium flasks was 37.7 μL. A minute after the application of one drop of balanced saline solution, the system released an adequate concentration for PRK surgery. Conclusion: A new MMC delivery system was created for transoperatory application in photorefractive keratectomy (PRK). Publication of the patent application (number PI 0704739-8) gives the authors exclusive intellectual property rights. The study was sponsored by Ophthalmos Indústria e Comércio de Produtos Farmacêuticos S.A. (São Paulo-SP, Brazil) and received the indispensable scientific contribution of researchers from the fields of Pharmacy, Medicine, Biology, Statistics and Law, characterizing the work as multidisciplinary, in accordance with norms established by the Postgraduate Health Sciences Program of the Federal University of Rio Grande do Norte (UFRN)
Resumo:
Objective: the ability of the laser irradiation to promote the cleaning and disinfection of the radicular canal system has become this type of treatment in a viable and real alternative in endodontics. The purpose of this study was to evaluate the apical marginal sealing of root canal fillings after the irradiation with the laser of Nd:YAG or of Er:YAG. Materials and Methods: Forty-two human, extracted single-rooted teeth had their crowns sectioned and the root canals prepared with a no. 70 K-file. Then, they were dried and divided into three groups according to canal wall treatment: group 1: the canals were filled with EDTA for 3 min, followed by irrigation with 1% sodium hypochlorite solution; group 2: the canal walls were irradiated with Nd:YAG laser; and group 3: the canal walls were irradiated with Er:YAG laser. Afterwards, the root canals were obturated by the lateral condensation technique. The roots were externally waterproof, except in the apical foramen and immerged in 2% methylene blue aqueous solution during 48 hours. Results: the results showed that the largest infiltrations happened in the group 3-Er:YAG (7.3 mm), proceeded by the group 1-EDTA (1.6 mm) and by the group 2-Nd:YAG (0.6 mm). The group Er:YAG differed statistically of the others (p < 0.05). Conclusion: It was concluded that the Er:YAG laser intracanal irradiation previously to the root canal filling must be used with caution until future research is define the best parameters for it's use.
Resumo:
In rare earth ion doped solids, a resonant non-linear refractive index, n2, appears when the laser pumps one of the ion excited states and the refractive index change is proportional to the excited state population. In these solids there are usually thermal and non-thermal lensing effects, where the non-thermal one is due to the polarizability difference, Δα, between excited and ground states of the ions. We have used the time resolved Z-scan and a mode-mismatched thermal lens technique with an Ar+ ion laser in Er+3 (20ZnF2-20SrF2-2NaF-16BaF2-6GaF3-(36 - x)InF3-xErF3, with x= 1, 2, 3 and 4 mol%) and Nd+3 (20SrF2-16BaF2-20ZnF2-2GdF3-2NaF-(40 - x)InF3-xNdF3, with x = 0.1, 0.25, 0.5-1 mol%) doped fluoroindate glasses. In both samples we found that the non-linear refraction is due to the thermal effect, while the non-thermal effect is negligible. This result indicates that in fluoride glasses Δα is very small (less than 10-26 cm3). We also measured the imaginary part of the non-linear refractive index (n″2) due to absorption saturation.
Resumo:
PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
Resumo:
Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.
Resumo:
PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.