908 resultados para LC-MSMS
Resumo:
The aim of this study was to develop and validate an analytical method to simultaneously determine European Union-regulated beta-lactams (penicillins and cephalosporins) and quinolones in cow milk. The procedure involves a new solid phase extraction (SPE) to clean-up and pre-concentrate the three series of antibiotics before analysis by liquid chromatography¿tandem mass spectrometry (LC-MS/MS) and ultra-high-performance liquid chromatography¿tandem mass spectrometry (UPLC-MS/MS). LC-MS/MS and UPLC-MS/MS techniques were also compared. The method was validated according to the Directive 2002/657/EC and subsequently applied to 56 samples of raw cow milk supplied by the Laboratori Interprofessional Lleter de Catalunya (ALLIC) (Laboratori Interprofessional Lleter de Catalunya, Control Laboratory Interprofessional of Milk of Catalunya).
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
BACKGROUND: Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. RESULTS: The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. CONCLUSION: The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
BACKGROUND: Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking. METHODS: We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them. RESULTS: The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients. CONCLUSIONS: The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.
Resumo:
Viime vuosien nopea kehitys on kiihdyttänyt uusien lääkkeiden kehittämisprosessia. Kombinatorinen kemia on tehnyt mahdolliseksi syntetisoida suuria kokoelmia rakenteeltaan toisistaan poikkeavia molekyylejä, nk. kombinatorisia kirjastoja, biologista seulontaa varten. Siinä molekyylien rakenteeseen liittyvä aktiivisuus tutkitaan useilla erilaisilla biologisilla testeillä mahdollisten "osumien" löytämiseksi, joista osasta saatetaan myöhemmin kehittää uusia lääkeaineita. Jotta biologisten tutkimusten tulokset olisivat luotettavia, on syntetisoitujen komponenttien oltava mahdollisimman puhtaita. Tämän vuoksi tarvitaan HTP-puhdistusta korkealaatuisten komponenttien ja luotettavan biologisen tiedon takaamiseksi. Jatkuvasti kasvavat tuotantovaatimukset ovat johtaneet näiden puhdistustekniikoiden automatisointiin ja rinnakkaistamiseen. Preparatiivinen LC/MS soveltuu kombinatoristen kirjastojen nopeaan ja tehokkaaseen puhdistamiseen. Monet tekijät, esimerkiksi erotuskolonnin ominaisuudet sekä virtausgradientti, vaikuttavat preparatiivisen LC/MS puhdistusprosessin tehokkuuteen. Nämä parametrit on optimoitava parhaan tuloksen saamiseksi. Tässä työssä tutkittiin emäksisiä komponentteja erilaisissa virtausolosuhteissa. Menetelmä kombinatoristen kirjastojen puhtaustason määrittämiseksi LC/MS-puhdistuksen jälkeen optimoitiin ja määritettiin puhtaus joillekin komponenteille eri kirjastoista ennen puhdistusta.
Resumo:
In this work methods for the multiresidue determination of the series of quinolones include in the European regulation in food of animal origin are de veloped and validated in line with Commission Decision 2002/657/EC in terms of linearity, decision limit, capability detection, precision and stability. Mult iresidue methods were established to allow the determination of quinolones covered by EU legislation in 2377/90/EC in muscle of chicken, turkey, pig and cow, plasma of cow and pig, liver of pig and milk of cow. First an extraction step was optimized and a SPE step was applied to clean!up and preconcentrate quinolones prior to their separation by CE or LC and determination by CE!UV, LC!UV, LC!Fl, LC!MS with different ion sources (ESI ,ApCI) and different mass analyser (Q, ToF) and LC!E SI!QqQ tandem mass spectrometry. The limits of quantification obtained are always lower than Maxim um Residue Limit (MRL) established by EU for quinolones in animal products and they can be applied to the control of quinolones in foodstuffs of animal origin . Finally the proposed methods were applied to determine quinolones in samples of turkey and pig muscle, pig plasma and milk of cow. Excellent quality parameters and reduced time of analysis were obtained when LC!ESI!MS/MS is used, although the others techniques presented too satisfactory results.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.