947 resultados para Internal fixation of fractures. Mandibular fractures. Biocompatible materials


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The carbonate outcrops of the anticline of Monte Conero (Italy) were studied in order to characterize the geometry of the fractures and to establish their influence on the petrophysical properties (hydraulic conductivity) and on the vulnerability to pollution. The outcrops form an analog for a fractured aquifer and belong to the Maiolica Fm. and the Scaglia Rossa Fm. The geometrical properties of fractures such as orientation, length, spacing and aperture were collected and statistically analyzed. Five types of mechanical fractures were observed: veins, joints, stylolites, breccias and faults. The types of fractures are arranged in different sets and geometric assemblages which form fracture networks. In addition, the fractures were analyzed at the microscale using thin sections. The fracture age-relationships resulted similar to those observed at the outcrop scale, indicating that at least three geological episodes have occurred in Monte Conero. A conceptual model for fault development was based on the observations of veins and stylolites. The fracture sets were modelled by the code FracSim3D to generate fracture network models. The permeability of a breccia zone was estimated at microscale by and point counting and binary image methods, whereas at the outcrop scale with Oda’s method. Microstructure analysis revealed that only faults and breccias are potential pathways for fluid flow since all veins observed are filled with calcite. According this, three scenarios were designed to asses the vulnerability to pollution of the analogue aquifer: the first scenario considers the Monte Conero without fractures, second scenario with all observed systematic fractures and the third scenario with open veins, joints and faults/breccias. The fractures influence the carbonate aquifer by increasing its porosity and hydraulic conductivity. The vulnerability to pollution depends also on the presence of karst zones, detric zones and the material of the vadose zone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first part of this three-part review on the relevance of laboratory testing of composites and adhesives deals with approval requirements for composite materials. We compare the in vivo and in vitro literature data and discuss the relevance of in vitro analyses. The standardized ISO protocols are presented, with a focus on the evaluation of physical parameters. These tests all have a standardized protocol that describes the entire test set-up. The tests analyse flexural strength, depth of cure, susceptibility to ambient light, color stability, water sorption and solubility, and radiopacity. Some tests have a clinical correlation. A high flexural strength, for instance, decreases the risk of fractures of the marginal ridge in posterior restorations and incisal edge build-ups of restored anterior teeth. Other tests do not have a clinical correlation or the threshold values are too low, which results in an approval of materials that show inferior clinical properties (e.g., radiopacity). It is advantageous to know the test set-ups and the ideal threshold values to correctly interpret the material data. Overall, however, laboratory assessment alone cannot ensure the clinical success of a product.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Delayed fracture healing and non-unions represent rare but severe complications in orthopedic surgery. Further knowledge on the mechanisms of the bone repair process and of the development of a pseudoarthrosis is essential to predict and prevent impaired healing of fractures. The present study aimed at elucidating differences in gene expression during the repair of rigidly and non-rigidly fixed osteotomies. For this purpose, the MouseFix™ and the FlexiPlate™ systems (AO Development Institute, Davos, CH), allowing the creation of well defined osteotomies in mouse femora, were employed. A time course following the healing process of the osteotomy was performed and bones and periimplant tissues were analyzed by high-resolution X-ray, MicroCT and by histology. For the assessment of gene expression, Low Density Arrays (LDA) were done. In animals with rigid fixation, X-ray and MicroCT revealed healing of the osteotomy within 3 weeks. Using the FlexiPlate™ system, the osteotomy was still visible by X-ray after 3 weeks and a stabilizing cartilaginous callus was formed. After 4.5 weeks, the callus was remodeled and the osteotomy was, on a histological level, healed. Gene expression studies revealed levels of transcripts encoding proteins associated with inflammatory processes not to be altered in tissues from bones with rigid and non-rigid fixation, respectively. Levels of transcripts encoding proteins of the extracellular matrix and essential for bone cell functions were not increased in the rigidly fixed group when compared to controls without osteotomy. In the FlexiPlate™ group, levels of transcripts encoding the same set of genes were significantly increased 3 weeks after surgery. Expression of transcripts encoding BMPs and BMP antagonists was increased after 3 weeks in repair tissues from bones fixed with FlexiPlate™, as were inhibitors of the WNT signaling pathways. Little changes only were detected in transcript levels of tissues from rigidly fixed bones. The data of the present study suggest that rigid fixation enables accelerated healing of an experimental osteotomy as compared to non-rigid fixation. The changes in the healing process after non-rigid fixation are accompanied by an increase in the levels of transcripts encoding inhibitors of osteogenic pathways and, probably as a consequence, by temporal changes in bone matrix synthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the introduction of strong discontinuities into a mesh will be developed. This method, applicable to a number of eXtended Finite Element Methods (XFEM) with intra-element strong discontinuities will be demonstrated with one specific method: the Generalized Cohesive Element (GCE) method. The algorithm utilizes a subgraph mesh representation which may insert the GCE either adaptively during the course of the analysis or a priori. Using this subgraphing algorithm, the insertion time is O(n) to the number of insertions. Numerical examples are presented demonstrating the advantages of the subgraph insertion method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION To present the accuracy of reduction, complications and results two years after open reduction and internal fixation of displaced acetabular fractures involving the anterior column (AC) through the Pararectus approach. Frequencies for conversion to total hip replacement in the early follow up, the clinical outcome in preserved hips, and the need for an extension of the approach (1st window of the ilioinguinal approach) are compared to the literature about the modified Stoppa approach. METHODS Forty-eight patients (mean age 62 years, range: 16–98; 41 male) with displaced acetabular fractures involving the AC (AC: n = 9; transverse fracture: n = 2; AC and hemitransverse: n = 24; both column: n = 13) were treated between 12/2009 and 12/2011 using the Pararectus approach. Surgical data and accuracy of reduction (using computed tomography) were assessed. Patients were routinely followed up at eight weeks, 6, 12 and 24 months postoperatively. Failure was defined as the need for total hip arthroplasty. Twenty-four months postoperatively the outcome was rated according to Matta. RESULTS In four patients there were four intraoperative complications (minor vascular damage in two, small perforations of the peritoneum in two) which were managed intraoperatively. Fracture reduction showed statistically significant decreases (mean ± SD, pre- vs. postoperative, in mm) in “step-offs”: 2.6 ± 1.9 vs. 0.1 ± 0.3, p < 0.001 and “gaps”: 11.2 ± 6.8 vs. 0.7 ± 0.9, p < 0.001. Accuracy of reduction was “anatomical” in 45, “imperfect” in three. Five (13%) from 38 available patients required a total hip arthroplasty. Of 33 patients with a preserved hip the clinical outcome was graded as “excellent” in 13 or “good” in 20; radiographically, 27 were graded as “excellent”, four as “good” and two as “fair”. An extension of the approach was infrequently used (1st window ilioinguinal approach in 2%, mini-incision at the iliac crest in 21%). CONCLUSION In the treatment of acetabular fractures involving the anterior column the Pararectus approach allowed for anatomic restoration with minimal access morbidity. Results obtained by means of the Pararectus approach after two years at least parallel those reported after utilisation of the modified Stoppa approach. In contrast to the modified Stoppa approach, a relevant extension of the Pararectus approach was almost not necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges. METHODS: Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically. RESULTS: Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs. CONCLUSIONS: More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stability of Le Fort I maxillary inferior repositioning surgery in patients with a vertical maxillary deficiency at least 6 months after surgery. The electronic databases were searched to identify all articles reporting the long-term effects of one-piece maxillary inferior repositioning with rigid fixation. Methodological quality was evaluated according to 15 criteria related to study design, measurements, and statistical analysis. Two articles were identified, with a total of 22 patients. The maxilla was repositioned inferiorly from a mean 3.2 to 4.5mm in the anterior part and from a mean 0.1 to 1.8mm in the posterior part. At 6 months post-treatment, absolute relapse of a mean 1.6mm was measured for the anterior part of the maxilla and 0.3mm for the posterior part of the maxilla. The stability of maxillary inferior repositioning surgery could not be confirmed due to the small sample size, unclear diagnosis, and potential confounding factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06