986 resultados para In vitro methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of cryopreservation protocols on subsequent development of in vitro produced bovine embryos under different culture conditions. Expanded in vitro produced blastocysts (n = 600) harvested on days 7-9 were submitted to controlled freezing [slow freezing group: 10% ethylene glycol (EG) for 10 min and 1.2 degrees C/min cryopreservation]; quick-freezing [rapid freezing group: 10% EG for 10 min, 20% EG + 20% glycerol (Gly) for 30 s]; or vitrification [vitrification group: 10% EG for 10 min, 25% EG + 25% Gly for 30 s] protocols. Control group embryos were not exposed to cryoprotectant or cryopreservation protocols and the hatching rate was evaluated on day 12 post-insemination. In order to evaluate development, frozen-thawed embryos were subjected to granulosa cell co-culture in TCM199 or SOFaa for 4 days. Data were analyzed by PROC MIXED model using SAS Systems for Windows (R). Values were significant at p < 0.05. The hatching rate of the control group was 46.09%. In embryos cultured in TCM199, slow freezing and vitrification group hatching rates were 44.65 +/- 5.94% and 9.43 +/- 6.77%, respectively. In embryos cultured in SOFaa, slow freezing and vitrification groups showed hatching rates of 11.65 +/- 3.37 and 8.67 +/- 4.47%, respectively. In contrast, the rapid freezing group embryos did not hatch, regardless of culture medium. The slow freezing group showed higher hatching rates than other cryopreservation groups. Under such conditions, controlled freezing (1.2 degrees C/min) can be an alternative to cryopreservation of in vitro produced bovine embryos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the direct and indirect radiographic methods for assessing the gray levels of biomaterials employing the Digora for Windows and the Adobe Photoshop CS2 systems. METHODS: Specimens of biomaterials were made following manusfacturer's instructions and placed on phosphor storage plates (PSP) and on radiographic film for subsequent gray level assessment using the direct and indirect radiographic method, respectively. The radiographic density of each biomaterial was analyzed using Adobe Photoshop CS2 and Digora for Windows software. RESULTS: The distribution of gray levels found using the direct and indirect methods suggests that higher exposure times are correlated to lower reproducibility rates between groups. CONCLUSION: The indirect method is a feasible alternative to the direct method in assessing the radiographic gray levels of biomaterials, insofar as significant reproducibility was observed between groups for the exposure times of 0.2 to 0.5 seconds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adult honey bees are maintained in vitro in laboratory cages for a variety of purposes. For example, researchers may wish to perform experiments on honey bees caged individually or in groups to study aspects of parasitology, toxicology, or physiology under highly controlled conditions, or they may cage whole frames to obtain newly emerged workers of known age cohorts. Regardless of purpose, researchers must manage a number of variables, ranging from selection of study subjects (e.g. honey bee subspecies) to experimental environment (e.g. temperature and relative humidity). Although decisions made by researchers may not necessarily jeopardize the scientific rigour of an experiment, they may profoundly affect results, and may make comparisons with similar, but independent, studies difficult. Focusing primarily on workers, we provide recommendations for maintaining adults under in vitro laboratory conditions, whilst acknowledging gaps in our understanding that require further attention. We specifically describe how to properly obtain honey bees, and how to choose appropriate cages, incubator conditions, and food to obtain biologically relevant and comparable experimental results. Additionally, we provide broad recommendations for experimental design and statistical analyses of data that arises from experiments using caged honey bees. The ultimate goal of this, and of all COLOSS BEEBOOK papers, is not to stifle science with restrictions, but rather to provide researchers with the appropriate tools to generate comparable data that will build upon our current understanding of honey bees.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Granulocytes are central players of the immune system and, once activated, a tightly controlled balance between effector functions and cell removal by apoptosis guarantees maximal host benefit with least possible collateral damage to healthy tissue. Granulocytes are end-differentiated cells that cannot be maintained in culture for prolonged times. Isolating primary granulocytes is inefficient and challenging when working with mice, and especially so for the lowly abundant eosinophil and basophils subtypes. Here we describe an in vitro protocol to massively expand mouse derived myeloid progenitors and to differentiate them ‘on demand’ and in large numbers into mature neutrophils or basophils.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of computer programs to predict drug absorption in humans and to simulate dissolution profiles has become a valuable tool in the pharmaceutical area. The objective of this study was to use in silico methods through software GastroPlusTM and DDDPlusTM to simulate drug absorption curves and dissolution profiles, and to establish in vitro-in vivo correlations (IVIVCs). The work presented herein is divided into five chapters and includes the drugs ketoprofen, pyrimethamine, metronidazole, fluconazole, carvedilol and doxazosin. In Chapter 1, simulated plasma curves for ketoprofen matrix tablets are presented and IVIVC was established. The use of simulated intrinsic dissolution tests for pyrimethamine and metronidazole as a tool for biopharmaceutics classification is detailed in Chapter 2. In Chapter 3, simulation of plasma curves for fluconazole capsules with different dissolution profiles is demonstrated as a tool for biowaiver. IVIVC studies were also conducted for carvedilol immediate-release tablets from dissolution profiles in Chapter 4. Chapter 5 covers the application of simulated dissolution tests for development of doxazosin extended-release formulations. Simulation of plasma curves and IVIVC using the software GastroPlusTM as well as intrinsic dissolution tests and dissolution profiles using the software DDDPlusTM proved to be a tool of wide application in predicting biopharmaceutical characteristics of drugs and formulations, allowing the reduction of time and costs of experimental laboratory work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Objective. The aim of this study was to evaluate the alteration of human enamel bleached with high concentrations of hydrogen peroxide associated with different activators. Materials and methods. Fifty enamel/dentin blocks (4 × 4 mm) were obtained from human third molars and randomized divided according to the bleaching procedure (n = 10): G1 = 35% hydrogen peroxide (HP - Whiteness HP Maxx); G2 = HP + Halogen lamp (HL); G3 = HP + 7% sodium bicarbonate (SB); G4 = HP + 20% sodium hydroxide (SH); and G5 = 38% hydrogen peroxide (OXB - Opalescence Xtra Boost). The bleaching treatments were performed in three sessions with a 7-day interval between them. The enamel content, before (baseline) and after bleaching, was determined using an FT-Raman spectrometer and was based on the concentration of phosphate, carbonate, and organic matrix. Statistical analysis was performed using two-way ANOVA for repeated measures and Tukey's test. Results. The results showed no significant differences between time of analysis (p = 0.5175) for most treatments and peak areas analyzed; and among bleaching treatments (p = 0.4184). The comparisons during and after bleaching revealed a significant difference in the HP group for the peak areas of carbonate and organic matrix, and for the organic matrix in OXB and HP+SH groups. Tukey's analysis determined that the difference, peak areas, and the interaction among treatment, time and peak was statistically significant (p < 0.05). Conclusion. The association of activators with hydrogen peroxide was effective in the alteration of enamel, mainly with regards to the organic matrix.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sunlight exposure causes several types of injury to humans, especially on the skin; among the most common harmful effects due to ultraviolet (UV) exposure are erythema, pigmentation and lesions in DNA, which may lead to cancer. These long-term effects are minimized with the use of sunscreens, a class of cosmetic products that contains UV filters as the main component in the formulation; such molecules can absorb, reflect or diffuse UV rays, and can be used alone or as a combination to broaden the protection on different wavelengths. Currently, worldwide regulatory agencies define which ingredients and what quantities must be used in each country, and enforce companies to conduct tests that confirm the Sun Protection Factor (SPF) and the UVA (Ultraviolet A) factor. Standard SPF determination tests are currently conducted in vivo, using human subjects. In an industrial mindset, apart from economic and ethical reasons, the introduction of an in vitro method emerges as an interesting alternative by reducing risks associated to UV exposure on tests, as well as providing assertive analytical results. The present work aims to describe a novel methodology for SPF determination directly from sunscreen formulations using the previously described cosmetomics platform and mass spectrometry as the analytical methods of choice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the capacity of potassium oxalate, fluoride gel and two kinds of propolis gel to reduce the hydraulic conductance of dentin, in vitro. MATERIAL AND METHODS: The methodology used for the measurement of hydraulic conductance of dentin in the present study was based on a model proposed in literature. Thirty-six 1-mm-thick dentin discs, obtained from extracted human third molars were divided into 4 groups (n=9). The groups corresponded to the following experimental materials: GI-10% propolis gel, pH 4.1; GII-30% propolis gel; GIII-3% potassium oxalate gel, pH 4,1; and GIV-1.23% fluoride gel, pH 4.1, applied to the dentin under the following surface conditions: after 37% phosphoric acid and before 6% citric acid application. The occluding capacity of the dentin tubules was evaluated using scanning electron microscopy (SEM) at ×500, ×1,000 and ×2,000 magnifications. Data were analyzed statistically by two-way ANOVA and Tukey's test at 5% significance level. RESULTS: Groups I, II, III, IV did not differ significantly from the others in any conditions by reducing in hydraulic conductance. The active agents reduced dentin permeability; however they produced the smallest reduction in hydraulic conductance when compared to the presence of smear layer (P<0.05). The effectiveness in reducing dentin permeability did not differ significantly from 10% or 30% propolis gels. SEM micrographs revealed that dentin tubules were partially occluded after treatment with propolis. CONCLUSIONS: Under the conditions of this study, the application of 10% and 30% propolis gels did not seem to reduce the hydraulic conductance of dentin in vitro, but it showed capacity of partially obliterating the dentin tubules. Propolis is used in the treatment of different oral problems without causing significant great collateral effects, and can be a good option in the treatment of patients with dentin sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. OBJECTIVE: The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. MATERIAL AND METHODS: Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey's test (α=0.05). RESULTS: Group 1 had a significantly higher (p<0.05) shear bond strength compared to groups 2 and 3. No difference was detected between groups 2 and 3 (p>0.05). CONCLUSIONS: The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: apesar da colagem direta despender menor tempo clínico, com maior preservação da integridade gengival, ainda hoje se observa uma alta incidência de bandagem dos molares. Portanto, torna-se interessante a idealização de recursos para o aumento da eficiência desse procedimento para dentes submetidos a maiores impactos mastigatórios, como, por exemplo, os molares. OBJETIVO: esse estudo teve o propósito de avaliar se a resistência à adesão com a aplicação de uma camada de resina adicional na região oclusal da interface tubo/dente aumenta a qualidade do procedimento de colagem direta de tubos em molares. MÉTODOS: selecionou-se uma amostra composta por 40 terceiros molares inferiores, que foram aleatoriamente divididos em 2 grupos: Grupo 1 - colagem direta convencional, seguida pela aplicação de uma camada de resina na oclusal da interface tubo/dente; e Grupo 2 - colagem direta convencional. O teste de resistência ao cisalhamento foi realizado 24 horas após a colagem, utilizando-se uma máquina de ensaio universal, operando a uma velocidade de 0,5mm/min. Os resultados foram analisados por meio do teste t independente. RESULTADOS: os valores médios obtidos nos testes de cisalhamento foram: 17,08MPa para o Grupo 1 e 12,60MPa para o Grupo 2. O Grupo 1 apresentou uma resistência ao cisalhamento estatisticamente significativa mais alta do que o Grupo 2. CONCLUSÃO: a aplicação de uma camada adicional de resina na oclusal da interface tubo/dente aumenta a qualidade da adesão do procedimento de colagem direta de tubos ortodônticos em molares.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.