266 resultados para Implantable cardioverter defibrillators


Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Energy harvesting devices are widely discussed as an alternative power source for todays active implantable medical devices. Repeated battery replacement procedures can be avoided by extending the implants life span, which is the goal of energy harvesting concepts. This reduces the risk of complications for the patient and may even reduce device size. The continuous and powerful contractions of a human heart ideally qualify as a battery substitute. In particular, devices in close proximity to the heart such as pacemakers, defibrillators or bio signal (ECG) recorders would benefit from this alternative energy source. The clockwork of an automatic wristwatch was used to transform the hearts kinetic energy into electrical energy. In order to qualify as a continuous energy supply for the consuming device, the mechanism needs to demonstrate its harvesting capability under various conditions. Several in-vivo recorded heart motions were used as input of a mathematical model to optimize the clockworks original conversion efficiency with respect to myocardial contractions. The resulting design was implemented and tested during in-vitro and in-vivo experiments, which demonstrated the superior sensitivity of the new design for all tested heart motions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early repolarization is a common electrocardiographic finding that is generally considered to be benign. Its potential to cause cardiac arrhythmias has been hypothesized from experimental studies, but it is not known whether there is a clinical association with sudden cardiac arrest. METHODS: We reviewed data from 206 case subjects at 22 centers who were resuscitated after cardiac arrest due to idiopathic ventricular fibrillation and assessed the prevalence of electrocardiographic early repolarization. The latter was defined as an elevation of the QRS-ST junction of at least 0.1 mV from baseline in the inferior or lateral lead, manifested as QRS slurring or notching. The control group comprised 412 subjects without heart disease who were matched for age, sex, race, and level of physical activity. Follow-up data that included the results of monitoring with an implantable defibrillator were obtained for all case subjects. RESULTS: Early repolarization was more frequent in case subjects with idiopathic ventricular fibrillation than in control subjects (31% vs. 5%, P<0.001). Among case subjects, those with early repolarization were more likely to be male and to have a history of syncope or sudden cardiac arrest during sleep than those without early repolarization. In eight subjects, the origin of ectopy that initiated ventricular arrhythmias was mapped to sites concordant with the localization of repolarization abnormalities. During a mean (+/-SD) follow-up of 61+/-50 months, defibrillator monitoring showed a higher incidence of recurrent ventricular fibrillation in case subjects with a repolarization abnormality than in those without such an abnormality (hazard ratio, 2.1; 95% confidence interval, 1.2 to 3.5; P=0.008). CONCLUSIONS: Among patients with a history of idiopathic ventricular fibrillation, there is an increased prevalence of early repolarization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Improved survival after prophylactic implantation of a defibrillator in patients with reduced left ventricular ejection fraction (EF) after myocardial infarction (MI) has been demonstrated in patients who experienced remote MIs in the 1990s. The absolute survival benefit conferred by this recommended strategy must be related to the current risk of arrhythmic death, which is evolving. This study evaluates the mortality rate in survivors of MI with impaired left ventricular function and its relation to pre-hospital discharge baseline characteristics. METHODS: The clinical records of patients who had sustained an acute MI between 1999 and 2000 and had been discharged from the hospital with an EF of < or = 40% were included. Baseline characteristics, drug prescriptions, and invasive procedures were recorded. Bivariate and multivariate analyses were performed using a primary end point of total mortality. RESULTS: One hundred sixty-five patients were included. During a median follow-up period of 30 months (interquartile range, 22 to 36 months) 18 patients died. The 1-year and 2-year mortality rates were 6.7% and 8.6%, respectively. Variables reflecting coronary artery disease and its management (ie, prior MI, acute reperfusion, and complete revascularization) had a greater impact on mortality than variables reflecting mechanical dysfunction (ie, EF and Killip class). CONCLUSIONS: The mortality rate among survivors of MIs with reduced EF was substantially lower than that reported in the 1990s. The strong decrease in the arrhythmic risk implies a proportional increase in the number of patients needed to treat with a prophylactic defibrillator to prevent one adverse event. The risk of an event may even be sufficiently low to limit the detectable benefit of defibrillators in patients with the prognostic features identified in our study. This argues for additional risk stratification prior to the prophylactic implantation of a defibrillator.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El desfibril•lador automàtic implantable evita la mort sobtada en prevenció secundària mentre que el benefici en prevenció primària és més discutit. L’objectiu del treball és conèixer la utilitat d’aquests aparells comparant prevenció primària i secundària. Des de l’any 2000 fins al 2008, s’han estudiat pacients amb miocardiopatia isquèmica i dilatada als que implantaven un desfibril•lador tant per prevenció primària i secundària. S’ha observat una infrautilització dels desfibril•ladors en la prevenció primària, però sobretot a la inclusió de pacients amb indicació MADIT II.