954 resultados para Icc
Resumo:
The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Objective: To determine item, subscale and total score agreement on the Frenchay Activities Index (FAI) between stroke patients and proxies six months after discharge from rehabilitation. Design: Prospective study design. Setting/subjects: Fifty patient-proxy pairs, interviewed separately, in the patient's residence. Main outcome measures: Modified FAI using 13 items. Individual FAI items, subscales and total score agreement as measured by weighted kappa and intraclass correlation coefficients (ICC). Results: Excellent agreement was found for the total FAI (ICC 0.87, 95% confidence interval (CI) 0.78-0.93), and domestic (ICC 0.85, 95% CI 0.73-0.91) and outdoor (ICC 0.87, 95% CI 0.78-0.95) subscales, with moderate agreement found for the work/leisure subscale (ICC 0.63, 95% CI 0.34-0.78). For the individual FAI items, good, moderate, fair and poor agreement was found for five, three, four and one item, respectively. The best agreement was for objective items of preparing meals, washing-up, washing clothes, shopping and driving. The poorest agreement was for participation in hobbies, social outings and heavy housework. Scoring biases associated with patient or proxy demographic characteristics were found. Female proxies, and those who were spouses, scored patients lower on domestic activities; male patients, and those who were younger, scored themselves higher on outdoor activities and higher patient FIM scores were positively correlated with higher FAI scores. Conclusions: While total and subscale agreement on the FAI was high, individual item agreement varied. Proxy scores should be used with caution due to bias.
Resumo:
Purpose: This study measured reliability between stroke patients' and significant others' scores on items on the Reintegration to Normal Living (RNL) Index and whether there were any scoring biases. Method The 11-item RNL Index was administered to 57 pairs of patients and significants six months after stroke rehabilitation. The index was scored using a 10-point visual analogue scale. Patient and significant other demographic information and data on patients' clinical, functional and cognitive status were collected. Reliability was measured using the intra-class correlation coefficient (ICC) and percent agreement. Results: Overall poor reliability was found for the RNL Index total score (ICC=.36, 95% CI. 07 to .59) and the daily functioning subscale (ICC=.24, 95% CI -.003 to .46) and moderate reliability was found for the perception of self subscale (ICC=.55, 95 % CI .28 to .73). There was a moderate bias for patients to rate themselves as achieving better reintegration than was indicated by significant others, although no demographic or clinical factors were associated with this bias. Exact match agreement was best for the subjective items and worse for items reflecting mobility around the community and participation in a work activity. Conclusions: Caution is needed when interpreting patient information reported by significant others on the RNL Index. The use of a shorter scale to rate the RNL Index requires investigation.
Resumo:
Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
A intensa atividade humana devasta grandes extensões de florestas nativas, seja para expansão da agricultura seja para suprir a crescente demanda do mercado por madeira, de uma forma ou de outra os pequenos fragmentos florestais remanescentes sofrem constantes pressões antrópicas, contudo, o uso de espécies arbóreas adaptadas pode contribuir para a proteção desses recursos naturais. Buscou-se neste estudo avaliar os padrões fenológicos de 109 espécies florestais arbóreas pertencentes a 37 famílias e 82 gêneros, dentre nativas e exóticas, com nove anos de idade, para diferenciar as mais adaptadas e com potencial de serem utilizadas em programas de reflorestamento. O estudo foi realizado na Fazenda Experimental do Incaper, em Jucuruaba, município de Viana-ES, (UTM E-345524, N- 7741039). Foram realizadas análises químicas do solo na área plantada e os dados climatológicos obtidos na estação meteorológica de Viana. O estudo baseou-se na observação do número de plantas sobreviventes de cada espécie e da avaliação do seu crescimento. Foram realizadas observações das fenofases de brotação, senescência de folhas, floração e frutificação. As avaliações fenológicas foram realizadas em intervalos mensais, no período de novembro de 2012 a outubro de 2013. Realizou-se a medição da altura das árvores, diâmetro à altura do peito (DAP), índice de enfolhamento, taxa de sobrevivência e cálculo do ICC (Índice Combinado de Crescimento), bem como a determinação das espécies mais adaptadas. Das 109 espécies estudadas, 64,22% apresentaram adaptação funcional e estrutural às condições de solo e clima da região experimental, 42,22 % floresceram e frutificaram e 90% apresentaram senescência e brotação acompanhando a sazonalidade climática. Vinte e nove espécies apresentaram ICC maior do que o ICC médio. A maioria das espécies destacou-se como alternativa para recuperação da cobertura vegetal local, com destaque para Inga uruguensis e Schizolobium amazonicum. As análises de fluorescência da clorofila revelaram que o aparato fotossintético da Schizolobium amazonicum foi capaz de protegê-la da fotoinibição e promover boa conversão da energia luminosa em fotoquímica.
Resumo:
Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.
Resumo:
Vários estudos demonstraram que os doentes com insuficiência cardíaca congestiva (ICC) têm um compromisso da qualidade de vida relacionada com a saúde (QVRS), tendo esta, nos últimos anos, vindo a tornar-se um endpoint primário quando se analisa o impacto do tratamento de situações crónicas como a ICC. Objectivos: Avaliar as propriedades psicométricas da versão portuguesa de um novo instrumento específico para medir a QVRS na ICC em doentes hospitalizados: o Kansas City Cardiomyopathy Questionnaire (KCCQ). População e Métodos: O KCCQ foi aplicado a uma amostra consecutiva de 193 doentes internados por ICC. Destes, 105 repetiram esta avaliação 3 meses após admissão hospitalar, não havendo eventos ocorridos durante este período de tempo. A idade era 64,4± 12,4 anos (entre 21 e 88), com 72,5% a pertencer ao sexo masculino, sendo a ICC de etiologia isquémica em 42%. Resultados: Esta versão do KCCQ foi sujeita a validação estatística semelhante à americana com a avaliação da fidelidade e validade. A fidelidade foi avaliada pela consistência interna dos domínios e dos somatórios, apresentando valores Alpha de Cronbach idênticos nos vários domínios e somatórios ( =0,50 a =0,94). A validade foi analisada pela convergência, pela sensibilidade às diferenças entre grupos e pela sensibilidade à alteração da condição clínica. Avaliou-se a validade convergente de todos os domínios relacionados com funcionalidade, pela relação verificada entre estes e uma medida de funcionalidade, a classificação da New York Heart Association (NYHA), tendo-se verificado correlações significativas (p<0,01), como medida para avaliar a funcionalidade em doentes com ICC. Efectuou-se uma análise de variância entre o domínio limitação física, os somatórios e as classes da NYHA, tendo-se encontrado diferenças estatisticamente significativas (F=23,4; F=36,4; F=37,4; p=0,0001), na capacidade de descriminação da gravidade da condição clínica. Foi realizada uma segunda avaliação em 105 doentes na consulta do 3º mês após a intervenção clínica, tendo-se observado alterações significativas nas médias dos domínios avaliados entre o internamento e a consulta (diferenças de 14,9 a 30,6 numa escala de 0-100), indicando que os domínios avaliados são sensíveis à mudança da condição clínica. A correlação interdimensões da qualidade de vida que compõe este instrumento é moderada, sugerindo dimensões independentes, apoiando a sua estrutura multifactorial e a adequabilidade desta medida para a sua avaliação. Conclusão: O KCCQ é um instrumento válido, sensível à mudança e específico para medir a QVRS numa população portuguesa com miocardiopatia dilatada e ICC. ABSTRACT - Several studies have shown that patients with congestive heart failure (CHF) have a compromised health-related quality of life (HRQL), and this, in recent years, has become a primary endpoint when considering the impact of treatment of chronic conditions such as CHF. Objectives: To evaluate the psychometric properties of the Portuguese version of a new specific instrument to measure HRQL in patients hospitalized for CHF: the Kansas City Cardiomyopathy Questionnaire (KCCQ). Methods: The KCCQ was applied to a sample of 193 consecutive patients hospitalized for CHF. Of these, 105 repeated the assessment 3 months after admission, with no events during this period. Mean age was 64.4±12.4 years (21-88), and 72.5% were 72.5% male. CHF was of ischemic etiology in 42% of cases. Results: This version of the KCCQ was subjected to statistical validation, with assessment of reliability and validity, similar to the American version. Reliability was assessed by the internal consistency of the domains and summary scores, which showed similar values of Cronbach alpha (0.50-0.94). Validity was assessed by convergence, sensitivity to differences between groups and sensitivity to changes in clinical condition. We evaluated the convergent validity of all domains related to functionality, through the relationship between them and a measure of functionality, the New York Heart Association (NYHA) classification. Significant correlations were found (p<0.01) for this measure of functionality in patients with CHF. Analysis of variance between the physical limitation domain, the summary scores and NYHA class was performed and statistically significant differences were found (F=23.4; F=36.4; F=37.4, p=0.0001) in the ability to discriminate severity of clinical condition. A second evaluation was performed on 105 patients at the 3-month follow-up outpatient appointment, and significant changes were observed in the mean scores of the domains assessed between hospital admission and the clinic appointment (differences from 14.9 to 30.6 on a scale of 0-100), indicating that the domains assessed are sensitive to changes in clinical condition. The correlation between dimensions of quality of life in the KCCQ is moderate, suggesting that the dimensions are independent, supporting the multifactorial nature of HRQL and the suitability of this measure for its evaluation. Conclusion: The KCCQ is a valid instrument, sensitive to change and a specific measure of HRQL in a population with dilated cardiomyopathy and CHF.
Resumo:
A terapêutica de ressincronização cardíaca (TRC), associada ou não a cardioversor-desfibrilhador, está recomendada no tratamento de doentes com insuficiência cardíaca congestiva (ICC) refractária e disfunção sistólica grave do ventrículo esquerdo, com evidência de dessíncronia. Objectivo: avaliar o impacto da TRC na qualidade de vida de doentes com ICC refractária ao tratamento farmacológico optimizado.
Resumo:
Tem sido documentado o impacto da terapêutica com cardioversor-desfibrilhador (CDI) e ressincronização cardíaca (TRC) na qualidade de vida, em doentes com insuficiência cardíaca congestiva grave (ICC). No entanto, permanece controverso o efeito mantido destas modalidades de tratamento nas diferentes dimensões que constituem a qualidade de vida. Objectivo: avaliar o impacto da TRC e do CDI na qualidade de vida de doentes com ICC refractária à terapêutica farmacológica optimizada em análises sequenciais consecutivas nos primeiros 6 meses pós-implantação destes dispositivos.
Resumo:
INTRODUÇÃO: Como parte do programa de investigação sobre violência familiar e desnutrição severa na infância, especificamente um estudo do tipo caso-controle foi avaliada a confiabilidade dos instrumentos utilizados no processo de obtenção de dados. Estudou-se a confiabilidade de quatro componentes do instrumento principal: (a) as Escalas sobre Táticas de Conflitos (Conflicts Tactics Scales - CTS) que medem o grau de conflito/violência familiar; (b) o instrumento CAGE (Cut-down; Annoyed; Guilty & Eye-opener) usado para indicar suspeição de alcoolismo; (c) o NSDUQ (Non-student Drugs Use Questionnaire) que visa aferir o uso de drogas ilícitas; e (d) a medida antropométrica de comprimento. MÉTODO: Para os três primeiros componentes citados foram avaliadas a estabilidade (confiabilidade intra-observador ou teste-reteste) e a equivalência (confiabilidade inter-observador), usando-se os 50 primeiros sujeitos captados no estudo caso-controle de fundo. Para a análise, usou-se o índice Kappa (k) com ajustamento (pseudo-Bayes) para lidar com problemas de estimabilidade. Em relação ao componente "d", foi estudada somente a equivalência (n=73), usando-se o Coeficiente de Correlação Intraclasse (Intra-class Correlation Coefficient - ICC) como estimador. RESULTADOS: Todos os componentes mostraram estabilidade e equivalência aceitáveis. Quanto à estabilidade das CTS, CAGE e NSDUQ, as estimações de k foram em torno de 0,70, 0,78 e 0,85, respectivamente. Em relação à equivalência, encontrou-se os valores de 1,0 para as CTS e NSDUQ e 0,75 para CAGE. A equivalência estimada através do ICC para comprimento foi de 0,99. Algumas situações desviantes foram observadas. Os resultados apontam para uma adequada padronização dos observadores e refletem a boa qualidade do processo de aferição referente ao estudo de fundo, encorajando a equipe de pesquisa a prosseguir com maior segurança.
Resumo:
INTRODUCTION: Self-reported weight and height were compared with direct measurements in order to evaluate the agreement between the two sources. METHOD: Data were obtained from a cross-sectional study on health status from a probabilistic sample of 1,183 employees of a bank, in Rio de Janeiro State, Brazil. Direct measurements were made of 322 employees. Differences between the two sources were evaluated using mean differences, limits of agreement and intraclass correlation coefficient (ICC). RESULTS AND CONCLUSIONS: Men and women tended to underestimate their weight while differences between self-reported and measured height were insignificant. Body mass index (BMI) mean differences were smaller than those observed for weight. ICC was over 0.98 for weight and 0.95 for BMI, expressing close agreement. Combining a graphical method with ICC may be useful in pilot studies to detect populational groups capable of providing reliable information on weight and height, thus minimizing resources needed for field work.
Resumo:
OBJETIVO: Analisar o uso do Sistema de Informações Hospitalares do Sistema Único de Saúde (SIH/SUS) no ajuste de risco das taxas de mortalidade hospitalar e avaliar a utilidade do índice de comorbidade de Charlson (ICC) no ajuste de risco de indicadores de desempenho. MÉTODOS: Foram selecionadas 40.299 internações ocorridas no Município do Rio de Janeiro entre dezembro de 1994 e dezembro de 1996. A medida de gravidade foi testada pelo ICC, que atribui pesos a 17 condições clínicas presentes nos diagnósticos secundários, a fim de obter a carga de morbidade do paciente (gravidade) independentemente do diagnóstico principal. Utilizou-se a regressão logística para avaliar o impacto do ICC na estimativa da chance de morrer no hospital. RESULTADOS: Nas internações selecionadas, observou-se que o ICC foi igual ou superior a um em apenas 5,7 % dos casos. Quando se aplicou o ICC combinado à idade, o percentual de casos com pontuação diferente de zero aumentou substancialmente. Os modelos testados apresentaram reduzida sensibilidade. CONCLUSÕES: Apesar de a presença de comorbidade ser importante na predição do risco de morrer, essa variável pouco discriminou a gravidade dos casos na base de dados do SIH/SUS, o que é explicado pela qualidade da informação diagnóstica nessa base de dados, na qual a idade é o preditor mais importante do risco de morrer, afora o diagnóstico principal. Apesar das limitações ainda existentes na qualidade da informação diagnóstica disponível no SIH/SUS, sugere-se o uso do ICC combinado como medida para ajuste do risco de morrer nas taxas calculadas a partir desses dados.
Resumo:
OBJETIVO: Traduzir e adaptar para o português o questionário de qualidade de vida denominado "King's Health Questionnaire" (KHQ) em mulheres com incontinência urinária. MÉTODOS: Cientes dos objetivos da pesquisa científica, dois tradutores brasileiros prepararam duas versões do KHQ para o português, as quais foram retro-traduzidas por outros dois tradutores ingleses. As diferenças foram harmonizadas e pré-testadas em um estudo piloto. As versões finais do KHQ e de outro questionário, o "Short-Form Health Survey" (SF-36), já vertido e publicado em português, foram simultaneamente administradas a 156 e 119 pacientes, respectivamente. Foram testadas as propriedades psicométricas do KHQ como confiabilidade (consistência interna e teste-reteste) e validade de constructo. O reteste foi realizado em um período de duas semanas, a partir da primeira entrevista. RESULTADOS: O processo de adaptação cultural não alterou a versão em português do KHQ comparado ao original, exceto no modo de administração para pacientes com baixo grau de alfabetização. Neste caso, o questionário mudou de auto-avaliação para ser lido para as pacientes durante entrevista com o pesquisador. Para as outras pacientes, o KHQ foi auto-administrado. O alfa de Cronbach padronizado do KHQ foi de 0,87 e avaliado por seus domínios variou de 0,49 a 0,92. A confiabilidade, medida pelo índice de correlação intraclasses (ICC) foi considerada de moderada a forte em todos os domínios e na escala de medidas de gravidade, variando de 0,53 a 0,81. O coeficiente de correlação de Pearson entre o KHQ e o SF-36 foi considerado de fraco a moderado na maioria dos domínios afins, variando de -0,27 a -0,53. CONCLUSÕES: A versão para o português do KHQ, traduzida e adaptada para seu uso em mulheres brasileiras com queixas de incontinência urinária. Representa um importante instrumento para a avaliação de mulheres incontinentes em pesquisa clínica.
Resumo:
OBJETIVO: Avaliar a qualidade da informação sobre óbito por infarto agudo do miocárdio nos sistemas de informação hospitalar e de mortalidade. MÉTODOS: Foram analisados dados sobre mortalidade hospitalar por infarto agudo do miocárdio, em 2000, utilizando as bases de dados do Sistema de Informação de Mortalidade (SIM) e do Sistema de Informação Hospitalar (SIH/SUS); e numa segunda etapa utilizaram-se de dados obtidos de levantamento direto de prontuários médicos de dois hospitais do Sistema Único de Saúde no município do Rio de Janeiro. Foi feita comparação entre prontuários, declarações de óbitos e formulários de autorização de internação hospitalar. Utilizou-se para confirmação do diagnóstico de infarto agudo do miocárdio critérios da Organização Mundial de Saúde. A concordância entre as informações presentes na declaração de óbito, autorização de internação hospitalar e prontuários foi utilizado o teste de Kappa de Cohen e o coeficiente de correlação intraclasse (ICC). RESULTADOS: O total de óbitos hospitalares por infarto agudo do miocárdio registrados no SIM é expressivamente maior que no SIH/SUS. Foram identificados três fontes que explicam grande parte da discrepância observada: ausência de emissão de autorização de internação hospitalar (32,9%), notificação de outro diagnóstico principal no SIH/SUS (19,2%) e subnotificação do óbito na autorização de internação hospitalar (3,3%). O diagnóstico de infarto foi confirmado em 67,1% dos casos de notificados na declaração de óbito. A sensibilidade da informação sobre óbito por infarto do miocárdio foi de aproximadamente 90% em ambos os sistemas de informação analisados. CONCLUSÕES: Os resultados mostraram ser necessário implementar medidas voltadas para a melhoria da qualidade da informação no SIH/SUS, tais como a padronização de critérios para emissão da autorização de internação hospitalar nas emergências e o treinamento das equipes dos sistemas de registro.
Resumo:
To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.