990 resultados para INTRAOCULAR-PRESSURE FLUCTUATIONS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of propofol on intraocular pressure (IOP) and end tidal CO2 (ETCO2) were studied because an elevation in the latter may alter IOP. Twenty dogs were divided into two groups (G1 and G2). G1 dogs were induced with 10 mg/kg (IV) of propofol followed by a 0.4 mg/kg/min continuous infusion of the same agent diluted in a 0.2% dextrose solution for 1 h. G(CAPS) 2 dogs served as the control group, where only dextrose solution was administered, under the same time intervals as in G1. Applanation tonometry (Tono-Pen) was used to determine IOP and ETCO2 as a method to determine partial CO2 pressure. Measurements were taken every 15 min for 1 h, with M1 occurring immediately before IV administration. IOP and ETCO2 were not statistically significant in either groups. Based on the results, it may be concluded that propofol does not alter IOP and ETCO2.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The maternal cardiovascular system undergoes progressive adaptations throughout pregnancy, causing blood pressure fluctuations. However, no consensus has been established on its normal variation in uncomplicated pregnancies. Objective: To describe the variation in systolic blood pressure (SBP) and diastolic blood pressure (DBP) levels during pregnancy according to early pregnancy body mass index (BMI). Methods: SBP and DBP were measured during the first, second and third trimesters and at 30-45 days postpartum in a prospective cohort of 189 women aged 20-40 years. BMI (kg/m2) was measured up to the 13th gestational week and classified as normal-weight (<25.0) or excessive weight (≥25.0). Longitudinal linear mixed-effects models were used for statistical analysis. Results: A decrease in SBP and DBP was observed from the first to the second trimester (βSBP=-0.394; 95%CI: -0.600- -0.188 and βDBP=-0.617; 95%CI: -0.780- -0.454), as was an increase in SBP and DBP up to 30-45 postpartum days (βSBP=0.010; 95%CI: 0.006-0.014 and βDBP=0.015; 95%CI: 0.012-0.018). Women with excessive weight at early pregnancy showed higher mean SBP in all gestational trimesters, and higher mean DBP in the first and third trimesters. Excessive early pregnancy BMI was positively associated with prospective changes in SBP (βSBP=7.055; 95%CI: 4.499-9.610) and in DBP (βDBP=3.201; 95%CI: 1.136-5.266). Conclusion: SBP and DBP decreased from the first to the second trimester and then increased up to the postpartum period. Women with excessive early pregnancy BMI had higher SBP and DBP than their normal-weight counterparts throughout pregnancy, but not in the postpartum period.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Intraocular gas bubbles expand as patients move up to higher altitude. This may cause an acute intraocular pressure (IOP) rise with associated vascular obstructions and visual loss. MATERIALS AND METHODS: Two pseudophakic patients underwent a pars plana vitrectomy and 23% SF6 gas tamponade for a pseudophakic retinal detachment. During the immediate post-operative phase, the patients travelled daily up to their domicile, which was situated approximately 600 m higher than the level where they had been operated on. These travels were always without any pain or visual loss. However 1 week after surgery both patients developed severe ocular pain, and one patient had complete temporary loss of vision after ascending to altitude levels, which had previously presented no problem. Both episodes occurred in parallel with a change in barometric pressure. RESULTS: Treatment with acetazolamide reduced the increased IOP to normal levels, and visual acuity recovered. CONCLUSIONS: Although the post-operative size of an intraocular gas bubble decreases progressively over time, problems with bubble expansion may still occur even at a late stage if meteorological factors, that may increase the bubble size, change.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP) on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectifs : Le bruxisme survenant au cours du sommeil est un trouble du mouvement caractérisé par du grincement de dents et l’activité rythmique des muscles masticateurs (ARMM). Le bruxisme/ARMM est souvent associé à des mouvements du corps et des à éveils corticaux. Une séquence d’activation précède le ARMM/bruxisme. Ces événements incluent une augmentation des variables suivants : l’activité sympathique (-4 minutes), les activités encéphalographique (-4 second), le fréquence cardiaque, l’amplitude de la respiration (-1 second) et l’activité des muscle suprahyoïdiens (-0.8 second). La présente étude a examiné l’association entre le bruxisme et les changements de la pression artérielle. Méthodes: Dix sujets avec le bruxisme (5 hommes, 5 femmes, âge moyen = 26 ± 1,8) ont complétés 3 nuits de polysomnographie qui comprenait l'enregistrement non invasive de la pression artérielle. La première nuit a servi de dépistage et d’habituation au laboratoire. L'analyse a été réalisée sur les deuxièmes et troisièmes nuits enregistrements. Seuls les épisodes de bruxisme isolés survenant au cours du stade 2 du sommeil ont été utilisés pour l’analyse, pour un total de 65 épisodes. Les mesures des pressions systolique et diastolique ont été prises 20 battements avant et 23 battements après l'apparition de chaque épisode bruxisme lors du sommeil. Les épisodes de bruxisme ont été classés comme suit: 1) bruxisme avec éveil cortical; 2) bruxisme avec mouvement du corps (MC), 3) bruxisme avec éveil cortical et MC. Une quatrième catégorie, bruxisme seul, a également été analysée, mais utilisée comme donnée préliminaire puisque la catégorie se composait de seulement 4 épisodes de bruxisme. Résultats: Les deux pressions systolique et diastolique ont augmenté avec les épisodes de bruxisme. Cette augmentation a été statistiquement significative pour la pression systolique et diastolique pour les épisodes de bruxisme avec éveil cortical et/ou MC (p ≤ 0,05). L’augmentation moyenne de la pression (systolique / diastolique ± SE) a été : 28,4 ± 2,4/13,2 ± 1,5 mm Hg pour le bruxisme avec éveil cortical; 30,7 ± 1,6/19.4 ± 2.3 mm Hg pour bruxisme avec MC; 26.4 ± 2,8 / 14,6 ± 2.0mm Hg pour bruxisme avec éveil cortical et MC; 22,9 ± 5,2/12,4 ± 3,3mm Hg pour les épisodes de bruxisme seuls. Conclusion: Le bruxisme du sommeil est associé à des hausses de la pression artérielle pendant le sommeil. Cette hausse est supérieure dans les épisodes de bruxisme associés à un éveil cortical et / ou MC, qui sont souvent associés avec les événements bruxisme. Ces résultats sont en accord avec nos observations antérieures, où le bruxisme est précédé par une augmentation de l'activité sympathique et de la tachycardie sinusale.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3% e sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2%. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It has been shown that the pressure-to-cornea index (PCI), which estimates the relative effects of intraocular pressure (IOP) and central corneal thickness (CCT), may differentiate between glaucoma and non-glaucoma states. The authors investigated the utility of the pressure-cornea-vascular index (PCVI) in predicting field-progression in patients with normal tension glaucoma (NTG).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Direct assessment of the effect of postural changes on interstitial fluid pressure (IFP) in the human skin under physiological conditions is important for the understanding of mechanisms involved in diseases resulting in lower limb edema. Previous techniques to measure IFP had limitations of being invasive, and acute measurements were not possible. Here we describe the effect of postural changes on IFP in the skin of the foot using the minimally invasive servonulling technique. RESULTS: Measurements were performed in 12 healthy subjects. IFP (means +/- SD) was significantly higher in the sitting (5.1 +/- 2.9 mm Hg) than in the supine position (-0.3 +/- 3.6 mm Hg, p = 0.04) when measured in the sitting position first. The difference between the sitting and the supine position was not significant when measurements were taken in the supine position first [from 1.0 +/- 4.3 (supine) to 3.6 +/- 6.7 mm Hg (sitting), p = 0.46]. Spontaneous low-frequency pressure fluctuations occurred in 58% of the recordings during sitting, which was almost twice as frequent as in the supine position (33%; p = 0.001), while no effects on lymphatic capillary network extension were observed (p = 0.12). CONCLUSION: Using the servonulling micropressure system, postural effects on IFP can be directly assessed. IFP is higher in the sitting position, but differences are influenced by the time in the upright position.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Several conversion tables and formulas have been suggested to correct applanation intraocular pressure (IOP) for central corneal thickness (CCT). CCT is also thought to represent an independent glaucoma risk factor. In an attempt to integrate IOP and CCT into a unified risk factor and avoid uncertain correction for tonometric inaccuracy, a new pressure-to-cornea index (PCI) is proposed. METHODS: PCI (IOP/CCT(3)) was defined as the ratio between untreated IOP and CCT(3) in mm (ultrasound pachymetry). PCI distribution in 220 normal controls, 53 patients with normal-tension glaucoma (NTG), 76 with ocular hypertension (OHT), and 89 with primary open-angle glaucoma (POAG) was investigated. PCI's ability to discriminate between glaucoma (NTG+POAG) and non-glaucoma (controls+OHT) was compared with that of three published formulae for correcting IOP for CCT. Receiver operating characteristic (ROC) curves were built. RESULTS: Mean PCI values were: Controls 92.0 (SD 24.8), NTG 129.1 (SD 25.8), OHT 134.0 (SD 26.5), POAG 173.6 (SD 40.9). To minimise IOP bias, eyes within the same 2 mm Hg range between 16 and 29 mm Hg (16-17, 18-19, etc) were separately compared: control and NTG eyes as well as OHT and POAG eyes differed significantly. PCI demonstrated a larger area under the ROC curve (AUC) and significantly higher sensitivity at fixed 80% and 90% specificities compared with each of the correction formulas; optimum PCI cut-off value 133.8. CONCLUSIONS: A PCI range of 120-140 is proposed as the upper limit of "normality", 120 being the cut-off value for eyes with untreated pressures or=22 mm Hg. PCI may reflect individual susceptibility to a given IOP level, and thus represent a glaucoma risk factor. Longitudinal studies are needed to prove its prognostic value.