957 resultados para Human eye


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Retinal blurring resulting from the human eye's depth of focus has been shown to assist visual perception. Infinite focal depth within stereoscopically displayed virtual environments may cause undesirable effects, for instance, objects positioned at a distance in front of or behind the observer's fixation point will be perceived in sharp focus with large disparities thereby causing diplopia. Although published research on incorporation of synthetically generated Depth of Field (DoF) suggests that this might act as an enhancement to perceived image quality, no quantitative testimonies of perceptional performance gains exist. This may be due to the difficulty of dynamic generation of synthetic DoF where focal distance is actively linked to fixation distance. In this paper, such a system is described. A desktop stereographic display is used to project a virtual scene in which synthetically generated DoF is actively controlled from vergence-derived distance. A performance evaluation experiment on this system which involved subjects carrying out observations in a spatially complex virtual environment was undertaken. The virtual environment consisted of components interconnected by pipes on a distractive background. The subject was tasked with making an observation based on the connectivity of the components. The effects of focal depth variation in static and actively controlled focal distance conditions were investigated. The results and analysis are presented which show that performance gains may be achieved by addition of synthetic DoF. The merits of the application of synthetic DoF are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It always has been a need for the abiltiy to create color proofs. When an error occurs late in the production process, itis allways complicated and difficult to correct the error. In this project, digital proofs been made and discussions havebeen held with several people in the printing industry, in order to examine how well excisting digital proofs, meet thedemand of the market. And how close the digital proofs can come to the actual printsheat from the press. The study hasbeen shown that the one thing that has had the most influence on the outcome for the quality of a digital proof, is theprintshop operator’s knowledge about color management and proofing systems. Many advertising agencies in the graphicindustry think rasterised proofs are not necessesary and expensive. Therefor they prefer a cheaper alternative, whichdoesn’t show colors as well as the rasterised proof, but well enough to be content with it. There are a good awarenessconcerning lack of communication between printshop, reproduction and advertising agency. Advertising agencies thinkthat printshop rarely listen to what they have to say, while the printshop think that the advertising agency doesn’t understandwhat they are trying to tell them. The outcome of the printed proofs in this study can’t be representive for howgood digital proofs are conducted in regular basis in the industry. The divergence between the print press sheat and thedigital proof that was made was bigger than expected. This shows that implementation of ICC profiles in a color managementflow, not alone is the answer to making perfect digital proofs. There are so many other issues that has to be examined,like color management software, measure tools and correct color management module. In order to make a perfectproof, you have to look at the whole picture. In the end, the human eye finally has the last word on wheather theproof is good or not.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The connection between fluorescence and color management still is a relatively unexplored area. Thefollowing composition analyses the theory that when printing on fluorescent ink jet paper using ICCprofilesa more yellow print will appear. In theory the ICC-profile compensate for blue light that fluorescefrom the paper with the complementary color, yellow. The human eye apprehands this fluorescentlight as white.When categorizing a number of ink jet qualities some tests to indicate change of color in the final printwere made. Five qualities were chosen for further analyses, each with different white point. TheTC3.5CMYK target was prined on an ink jet printer and measured with different filters for the measurementequipment, GretagMacbeth Spectrolino. U- and UV-filters were used during the testings.From the measurement data ICC-profiles were made to make it possible to watch how the profiles compensatefor the blue change of color that appeared in the data. Although a distinct change of color intoblue were discernible in the measured data there is no evident proof that this cause a final print thatis more yellow. Other conclusions and results are to be read at the end of this composition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulse oximerry has become one of the most commonly used tools in the clinical environment for assessing patients' oxygenation status. It is employed almost continuously in critical care areas and frequently in the general ward environment. Although it is a much better tool for determining hypoxia than the human eye, its use is limited if clinicians do not understand relevant physiological principles, such as the oxyhaemoglobin dissociation curve and the inherent limitations of the device. Furthermore, the risk for compromised patient safety is significant if clinicians fail to recognise the potential for false or erroneous readings. This paper explores the research which has examined clinicians' comprehension of pulse oximetry. Fourteen studies examining clinicians' knowledge of pulse oximerry were reviewed. These studies revealed significant knowledge deficits about pulse oximerry amongst nurses, doctors and allied health professionals, all of whom used this technology frequently. Alarmingly, those lacking an adequate understanding of pulse oximerry included senior, experienced clinicians. The studies were limited by their use of convenience sampling and small sample sizes. Further research is needed to better understand the significance of this problem and to examine how principles of pulse oximerry are taught to nurses and other health professionals at the undergraduate and postgraduate levels. Educators and clinicians alike must ensure that a safe level of knowledge for the use of pulse oximerry is maintained in order to ensure that patient outcomes are not compromised.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite major differences between human and avian colour vision, previous studies of cuckoo egg mimicry have used human colour vision (or standards based thereon) to assess colour matching. Using ultraviolet-visible reflectance spectrophotometry (300-700 nm), we measured museum collections of eggs of the red-chested cuckoo and its hosts. The first three principal components explained more than 99% of the variance in spectra, and measures of cuckoo-host egg similarity derived from these transformations were compared with measures of cuckoo-host egg similarity estimated by human observers unaware of the hypotheses we were testing. Monte Carlo methods were used to simulate laying of cuckoo eggs at random in nests. Results showed that host and cuckoo eggs were very highly matched for an ultraviolet versus greenness component, which was not detected by humans. Furthermore, whereas cuckoo and host were dissimilar in achromatic brightness, humans did not detect this difference. Our study thus reveals aspects of cuckoo-host egg colour matching which have hitherto not been described. These results suggest subtleties and complexities in the evolution of host-cuckoo egg mimicry that were not previously suspected. Our results also have the potential to explain the longstanding paradox that some host species accept cuckoo eggs that are non-mimetic to the human eye.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A inflamação ocular é uma das principais causas de perda visual e cegueira. As uveítes constituem um grupo complexo e heterogêneo de doenças caracterizadas por inflamação dos tecidos intraoculares. O olho pode ser o único órgão envolvido ou a uveíte pode ser parte de uma doença sistêmica. A etiologia é desconhecida em um número significativo de casos, que são considerados idiopáticos. Modelos animais têm sido desenvolvidos para estudar a fisiopatogênese da uveíte autoimune devido às dificuldades na obtenção de tecidos de olhos humanos inflamados para experimentos. Na maioria desses modelos, que simulam as uveítes autoimunes em humanos, a uveíte é induzida com proteínas específicas de fotorreceptores (antígeno-S, proteína ligadora de retinoide do interfotoreceptor, rodopsina, recoverina e fosducina). Antígenos não retinianos, como proteínas associadas à melanina e proteína básica de mielina, são também bons indutores de uveíte em animais. Entender os mecanismos básicos e a patogênese dessas doenças oculares é essencial para o desenvolvimento de novas formas de tratamento das uveítes autoimunes e de novos agentes terapêuticos. Nesta revisão serão abordados os principais modelos experimentais utilizados para o estudo de doenças inflamatórias oculares autoimunes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Staining of prosthodontic materials may result in patient dissatisfaction and additional expense for replacement. This study aimed to determine the color stability of two heat-cured denture base acrylic (Lucitone 550, Vipi Cril) and one nylon denture base resin (Transflex) after immersion in beverages. Materials and Methods: Forty disks of each resin (20.0-mm diameter, 3.0-mm thick) were prepared and stored in distilled water for 24 hours at 37°C. During that time (T 0), the color of all specimens was spectrophotometrically measured. Each specimen was immersed in coffee, cola, red wine, and distilled water as a means of control. After 15-day (T 1) and 30-day (T 2) periods of immersion, the color of the specimens was measured again. The CIE (Commission Internationale de L' Eclairage) L*a*b* system was used to determine mean ΔE (color changes) values for each material and compared statistically with two-way ANOVA and Bonferroni intervals at 0.95. Results: In ΔET 0T 1 and ΔET 0T 2 the most severe staining was apparent with red wine (p < 0.001), followed by coffee (p < 0.01), when compared to the specimens stored in distilled water. Transflex also showed significant color change after immersion in cola (p < 0.01). In ΔET 1T 2 only red wine promoted significant staining of all resins (p < 0.0001). Conclusion: Chromatic changes were exhibited by specimens immersed in red wine, followed by coffee. For Transflex, cola also promoted color changes. The values of color changes converted to National Bureau of Standard units showed them to be perceivable to the human eye. © 2011 by the American College of Prosthodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present work, the basic concepts of radiometric, photometric and colorimetric calibration are presented, which were applied to three light-emitting diodes (LEDs) used to compose the different color sensations that the human eye perceives in the visible region of the electromagnetic spectrum. In this sense, an experimental setup comprising a LED drive circuit and a home-made integrating sphere was assembled for the initial radiometric and photometric calibration as well as to obtain a set of intensity and spectral combinations associated to different colorimetric CIE (Commission Internationale de l'Eclairage) coordinates. The reader can, therefore, understand, in a simple manner, the process of color composition inside a color monitor or display picture element (pixel ). © Sociedade Brasileira de Física.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Optics consists in the study of interaction of light with physical systems. The human vision is a product of the interaction of light with the eye (a very peculiar physical system). Here we present a basic study of the relationship between the optics and human vision, including: - The fundaments and physicals properties who characterize the light and the colors and the characteristics of the incidence mediums. - The basics laws of geometrical optics, based in the rectilinear propagation of light in the form of a light ray, in the independence of light rays and in the principle of reversibility of the light beams. This principle is present in the process of image formations in lenses and mirrors and applied in the study of image formation in the human eye. - The refraction and reflection laws and types of lenses, who permits the construction of optics devices for the study of physical universe, and the appliances to correct vision diseases. - Presents the human vision process as consisting in the reception of light (electromagnetic radiation in the zone of wavelength visible to us) through the eye and the sending of information obtained by the retina to the brain where it is interpreted. The vision involves a biophysical relation between the light and the biological structure of the eye who is constituted by cornea, iris, crystalline and retina. Analyzes is made of how some parts of the eye performs a function in the reception and sending of information of the images to the brain

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: this study aimed to analyze the in vitro effect of brushing on the color stability of ceramic brackets immersed in dye solutions. Materials and Methods: seven ceramic brackets of four commercial brands were tested: two monocrystalline and two polycrystalline. The parameters of color were obtained by spectrophotometer before and after 21 days of immersion of the brackets in coffee, red wine, Coca-Cola, black tea and artificial saliva. Another group of brackets of each brand were also immersed in the same solutions and for an equal time to the previous group, but with intervals of daily brushing performed by a toothbrushing machine (Mavtec). The data were evaluated by analysis of variance, multiple comparison tests for means and Student's t-test. Results: the mean color change of the brackets without brushing ranged from 0.46 to 7.61, while in the group with brushing these means ranged from 0.36 to 2.50. The staining still remained noticeable (change of color greater than 3.7) for all brackets when immersed in black tea. Conclusion: daily brushing helped significantly in the color stability of ceramic brackets, maintaining the color change to levels considered not visible to the human eye, except for the solution of black tea in which the staining remained relevant.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS. In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardt's disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5+5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS. EPTs varied between disease groups (20 Hz: healthy subjects: 0.062 +/- 0.038 mA; STG: 0.102 +/- 0.097 mA; POAG: 0.127 +/- 0.09 mA; NAION: 0.244 +/- 0.126 mA; RP: 0.371 +/- 0.223 mA; RAO: 0.988 +/- 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS. Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2012; 53: 7440-7448) DOI:10.1167/iovs.12-9612

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.