790 resultados para Human Factor Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Objective: To evaluate the effectiveness of human recombinant activated factor VII (rhFVIIa, NovoSeven) in avoiding hysterectomy postpartum in the management of severe postpartum hemorrhage (PPH). Methods: We performed a prospective cohort study at our university tertiary care center. Patients with severe post partum hemorrhage (blood loss >2000 mL) and failed medical and uterus-preserving surgical management, were treated with intravenous bolus administration of rhVIIa. Main outcome measures were cessation of bleeding, postpartum hysterectomy and thromboembolic events. Results: In 20/22 patients included, PPH was caused primarily by uterine atony, including 7 (32%) with additional lower genital tract lesion; in two women, it was due to pathologic placentation (placenta increta, 9%). One case of amniotic fluid embolism and one woman with uterine inversion were included. Recombinant hFVIIa was successful in stopping the PPH and in preventing a hysterectomy in 20/22 women (91%). The remaining two patients with persistent bleeding despite rhFVIIa treatment, who underwent postpartum hysterectomy, had placenta increta. No thromboembolic event was noticed. Conclusions: This study describes the largest single center series of rhFVIIa treatment for fertility preservation in severe postpartum hemorrhage published to date. Our data suggest that administration of rhFVIIa is effective in avoiding postpartum hysterectomy after conservative medical and surgical measures have failed. Although randomized studies are lacking, rhFVIIa should be considered as a second-line therapeutic option of life-threatening postpartal bleeding, in particular if preservation of fertility is warranted and hysterectomy is to be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synaesthesia is a heterogeneous phenomenon, even when considering one particular sub-type. The purpose of this study was to design a reliable and valid questionnaire for grapheme-colour synaesthesia that captures this heterogeneity. By the means of a large sample of 628 synaesthetes and a factor analysis, we created the Coloured Letters and Numbers (CLaN) questionnaire with 16 items loading on 4 different factors (i.e., localisation, automaticity/attention, deliberate use, and longitudinal changes). These factors were externally validated with tests which are widely used in the field of synaesthesia research. The questionnaire showed good test–retest reliability and construct validity (i.e., internally and externally). Our findings are discussed in the light of current theories and new ideas in synaesthesia research. More generally, the questionnaire is a useful tool which can be widely used in synaesthesia research to reveal the influence of individual differences on various performance measures and will be useful in generating new hypotheses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the earliest accounts of duration perception by Karl von Vierordt implied a common process underlying the timing of intervals in the sub-second and the second range. To date, there are two major explanatory approaches for the timing of brief intervals: the Common Timing Hypothesis and the Distinct Timing Hypothesis. While the common timing hypothesis also proceeds from a unitary timing process, the distinct timing hypothesis suggests two dissociable, independent mechanisms for the timing of intervals in the sub-second and the second range, respectively. In the present paper, we introduce confirmatory factor analysis (CFA) to elucidate the internal structure of interval timing in the sub-second and the second range. Our results indicate that the assumption of two mechanisms underlying the processing of intervals in the second and the sub-second range might be more appropriate than the assumption of a unitary timing mechanism. In contrast to the basic assumption of the distinct timing hypothesis, however, these two timing mechanisms are closely associated with each other and share 77% of common variance. This finding suggests either a strong functional relationship between the two timing mechanisms or a hierarchically organized internal structure. Findings are discussed in the light of existing psychophysical and neurophysiological data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most influential theoretical account in time psychophysics assumes the existence of a unitary internal clock based on neural counting. The distinct timing hypothesis, on the other hand, suggests an automatic timing mechanism for processing of durations in the sub-second range and a cognitively controlled timing mechanism for processing of durations in the range of seconds. Although several psychophysical approaches can be applied for identifying the internal structure of interval timing in the second and sub-second range, the existing data provide a puzzling picture of rather inconsistent results. In the present chapter, we introduce confirmatory factor analysis (CFA) to further elucidate the internal structure of interval timing performance in the sub-second and second range. More specifically, we investigated whether CFA would rather support the notion of a unitary timing mechanism or of distinct timing mechanisms underlying interval timing in the sub-second and second range, respectively. The assumption of two distinct timing mechanisms which are completely independent of each other was not supported by our data. The model assuming a unitary timing mechanism underlying interval timing in both the sub-second and second range fitted the empirical data much better. Eventually, we also tested a third model assuming two distinct, but functionally related mechanisms. The correlation between the two latent variables representing the hypothesized timing mechanisms was rather high and comparison of fit indices indicated that the assumption of two associated timing mechanisms described the observed data better than only one latent variable. Models are discussed in the light of the existing psychophysical and neurophysiological data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background context Studies involving factor analysis (FA) of the items in the North American Spine Society (NASS) outcome assessment instrument have revealed inconsistent factor structures for the individual items. Purpose This study examined whether the factor structure of the NASS varied in relation to the severity of the back/neck problem and differed from that originally recommended by the developers of the questionnaire, by analyzing data before and after surgery in a large series of patients undergoing lumbar or cervical disc arthroplasty. Study design/setting Prospective multicenter observational case series. Patient sample Three hundred ninety-one patients with low back pain and 553 patients with neck pain completed questionnaires preoperatively and again at 3 to 6 and 12 months follow-ups (FUs), in connection with the SWISSspine disc arthroplasty registry. Outcome measures North American Spine Society outcome assessment instrument. Methods First, an exploratory FA without a priori assumptions and subsequently a confirmatory FA were performed on the 17 items of the NASS-lumbar and 19 items of the NASS-cervical collected at each assessment time point. The item-loading invariance was tested in the German version of the questionnaire for baseline and FU. Results Both NASS-lumbar and NASS-cervical factor structures differed between baseline and postoperative data sets. The confirmatory analysis and item-loading invariance showed better fit for a three-factor (3F) structure for NASS-lumbar, containing items on “disability,” “back pain,” and “radiating pain, numbness, and weakness (leg/foot)” and for a 5F structure for NASS-cervical including disability, “neck pain,” “radiating pain and numbness (arm/hand),” “weakness (arm/hand),” and “motor deficit (legs).” Conclusions The best-fitting factor structure at both baseline and FU was selected for both the lumbar- and cervical-NASS questionnaires. It differed from that proposed by the originators of the NASS instruments. Although the NASS questionnaire represents a valid outcome measure for degenerative spine diseases, it is able to distinguish among all major symptom domains (factors) in patients undergoing lumbar and cervical disc arthroplasty; overall, the item structure could be improved. Any potential revision of the NASS should consider its factorial structure; factorial invariance over time should be aimed for, to allow for more precise interpretations of treatment success.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Teen pregnancy is a continuing problem, bringing with it a host of associated health and social risks. Alternative school students are especially at risk, but are historically under-represented in research. This is especially problematic in that instruments are needed to guide effective intervention development, but psychometrics for these instruments cannot be assumed when used in new populations. Decisional balance from the transtheoretical model offers a framework for understanding condom decision making, but has not been tested with alternative school students. Using responses from 640 subjects from Safer Choices 2 (a school-based HIV/STD/pregnancy prevention program implemented in 10 urban, southwestern alternative schools), a decisional balance scale for condom use was examined. A two-factor, mildly correlated model fit the data well. Tests of invariance examined scale functioning within gender and racial/ethnic groups. The underlying structure varied slightly based on subgroup, but on a practical level the impact on the use of scales was minimal. The structure and loadings were invariant across experimental condition. The pro scale was associated with a lower probability of having engaged in unprotected sexual behavior for sexually active subjects, and this association remained significant while controlling for demographic variables. The con scale did not show a significant association with engagement in unprotected sexual behaviors. Limitations and directions for future research were also discussed.^