922 resultados para Hip adduction
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
Objectives: to evaluate the effectiveness of a policy of making hip protectors available to residents of nursing homes. Design: a cluster randomised controlled trial of the policy in nursing and residential homes, with the home as the unit of randomisation. Setting: 127 nursing and residential homes in the greater Belfast area of Northern Ireland. Participants: 40 homes in the intervention group (representing 1,366 occupied beds) and 87 homes in the control group (representing 2,751 occupied beds). Interventions: a policy of making hip protectors available free of charge to residents of nursing homes and supporting the implementation process by employing a nurse facilitator to encourage staff in the homes to promote their use, over a 72-week period. Main outcome measures: the rate of hip fractures in intervention and control homes, and the level of adherence to use of hip protectors. Results: there were 85 hip fractures in the intervention homes and 163 in the control homes. The mean fracture rate per 100 residents was 6.22 in the intervention homes and 5.92 in the control homes, giving an adjusted rate ratio for the intervention group compared to the control group of 1.05 (95% CI 0.77, 1.43, P = 0.76). Initial acceptance of the hip protectors was 37.2% (508/1,366) with adherence falling to 19.9% (272/1,366) at 72 weeks.Conclusions: making hip protectors available to residents of nursing and residential homes did not reduce the rate of hip fracture. This research does not support the introduction of a policy of providing hip protectors to residents of nursing homes.
Resumo:
BACKGROUND: We sought to improve upon previously published statistical modeling strategies for binary classification of dyslipidemia for general population screening purposes based on the waist-to-hip circumference ratio and body mass index anthropometric measurements. METHODS: Study subjects were participants in WHO-MONICA population-based surveys conducted in two Swiss regions. Outcome variables were based on the total serum cholesterol to high density lipoprotein cholesterol ratio. The other potential predictor variables were gender, age, current cigarette smoking, and hypertension. The models investigated were: (i) linear regression; (ii) logistic classification; (iii) regression trees; (iv) classification trees (iii and iv are collectively known as "CART"). Binary classification performance of the region-specific models was externally validated by classifying the subjects from the other region. RESULTS: Waist-to-hip circumference ratio and body mass index remained modest predictors of dyslipidemia. Correct classification rates for all models were 60-80%, with marked gender differences. Gender-specific models provided only small gains in classification. The external validations provided assurance about the stability of the models. CONCLUSIONS: There were no striking differences between either the algebraic (i, ii) vs. non-algebraic (iii, iv), or the regression (i, iii) vs. classification (ii, iv) modeling approaches. Anticipated advantages of the CART vs. simple additive linear and logistic models were less than expected in this particular application with a relatively small set of predictor variables. CART models may be more useful when considering main effects and interactions between larger sets of predictor variables.
Resumo:
BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.
Resumo:
SUMMARY: BMD and clinical risk factors predict hip and other osteoporotic fractures. The combination of clinical risk factors and BMD provide higher specificity and sensitivity than either alone. INTRODUCTION AND HYPOTHESES: To develop a risk assessment tool based on clinical risk factors (CRFs) with and without BMD. METHODS: Nine population-based studies were studied in which BMD and CRFs were documented at baseline. Poisson regression models were developed for hip fracture and other osteoporotic fractures, with and without hip BMD. Fracture risk was expressed as gradient of risk (GR, risk ratio/SD change in risk score). RESULTS: CRFs alone predicted hip fracture with a GR of 2.1/SD at the age of 50 years and decreased with age. The use of BMD alone provided a higher GR (3.7/SD), and was improved further with the combined use of CRFs and BMD (4.2/SD). For other osteoporotic fractures, the GRs were lower than for hip fracture. The GR with CRFs alone was 1.4/SD at the age of 50 years, similar to that provided by BMD (GR = 1.4/SD) and was not markedly increased by the combination (GR = 1.4/SD). The performance characteristics of clinical risk factors with and without BMD were validated in eleven independent population-based cohorts. CONCLUSIONS: The models developed provide the basis for the integrated use of validated clinical risk factors in men and women to aid in fracture risk prediction.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
OBJECTIVES This study was designed to assess effects of cholinergic stimulation using acetylcholinesterase inhibitors (AChEIs), a group of drugs that stimulate cholinergic receptors and are used to treat Alzheimer's disease (AD), on healing of hip fractures. METHODS A retrospective cohort study was performed using 46-female AD patients, aged above 75 years, who sustained hip fractures. Study analyses included the first 6-months after hip fracture fixation procedure. Presence of AChEIs was used as predictor variable. Other variables that could affect study outcomes: age, body mass index (BMI), mental state or type of hip fracture, were also included. Radiographic union at fracture site (Hammer index), bone quality (Singh index) and fracture healing complications were recorded as study outcomes. The collected data was analyzed by student's-t, Mann-Whitney-U and chi-square tests. RESULTS No significant differences in age, BMI, mental state or type of hip fracture were observed between AChEIs-users and nonusers. However, AChEIs-users had better radiographic union at the fracture site (relative risk (RR),2.7; 95%confidence interval (CI),0.9-7.8), better bone quality (RR,2.0; 95%CI,1.2-3.3) and fewer healing complications (RR,0.8; 95%CI,0.7-1.0) than nonusers. CONCLUSION In elderly female patients with AD, the use of AChEIs might be associated with an enhanced fracture healing and minimized complications.