953 resultados para Hemodynamics, Intermittent Positive-Pressure Ventilation
Resumo:
Objective: To compare intermittent mandatory ventilation (IMV) with synchronized intermittent mandatory ventilation plus pressure support (SIMV+PS) in terms of time on mechanical ventilation, duration of weaning and length of stay in a pediatric intensive care unit (PICU).Methods: This was a randomized clinical trial that enrolled children aged 28 days to 4 years who were admitted to a PICU between October of 2005 and June of 2007 and put on mechanical ventilation (MV) for more than 48 hours. These patients were allocated to one of two groups by drawing lots: IMV group (IMVG; n = 35) and SIMV+PS group (SIMVG; n = 35). Children were excluded if they had undergone tracheotomy or had chronic respiratory diseases. Data on oxygenation and ventilation were recorded at admission and at the start of weaning.Results: There were no statistical differences between the groups in terms of age, sex, indication for MV, PRISM score, Comfort scale, use of sedatives or ventilation and oxygenation parameters. The median time on MV was 5 days for both groups (p = 0.120). There were also no statistical differences between the two groups for duration of weaning [IMVG: 1 day (1-6) vs. SIMVG: 1 day (1-6); p = 0.262] or length of hospital stay [IMVG: 8 days (2-22) vs. SIMVG: 6 days (3-20); p = 0.113].Conclusion: Among the children studied here, there was no statistically significant difference between IMV and SIMV+ PS in terms of time on MV, duration of weaning or time spent in the PICU.ClinicalTrials.govID: NCT00549809.
Resumo:
Opioids are most commonly used for treatment of severe pain. However, the fear of respiratory depression has restricted the use of opioids. Depending on the monitoring system used, different modes of opioid respiratory effects have been noted in previous studies. All opioids also cause alterations in hemodynamics at least to some extent. The main goal of this series of investigations was to elucidate the native ventilatory and hemodynamic effects of different opioids. Studies I-IV each involved 8 healthy male volunteers. Study V involved 13 patients with lower or upper extremity traumas. The opioids studied were morphine, oxycodone, pethidine, fentanyl, alfentanil, tramadol and ketamine. The respiratory parameters used in this study were breathing pattern measured with respiratory inductive plethysmography, gas exchange measured with indirect calorimetry, blood gas analysis and pulse oximetry. Hemodynamics was measured with arterial blood pressure, heart rate and oxygen consumption. Plasma catecholamine and histamine concentrations were also determined. All opioids studied caused an alteration in respiratory function. Respiratory rate, alveolar ventilation and minute ventilation decreased, while tidal volume increased in most situations. Breathing pattern was also significantly affected after opioid administration. The respiratory depression caused by oxycodone was deeper than the one caused by same dose of morphine. An equianalgesic dose of tramadol caused markedly smaller respiratory depression compared to pethidine. The potency ratio for respiratory depression of fentanyl and alfentanil is similar to analgesic potency ratio studied elsewhere. Racemic ketamine attenuated the respiratory depression caused by fentanyl, if measured with minute ventilation. However, this effect was counteracted by increased oxygen consumption. Supplemental oxygen did not offer any benefits, nor did it cause any atelectasis when given to opioid treated trauma patients. Morphine caused a transient hemodynamic stimulation, which was accompanied by an increase in oxygen consumption. Oxycodone, alfentanil, fentanyl, tramadol and pethidine infusions had minimal effects on hemodynamics. Plasma catecholamine concentrations were increased after high dose opioid administration. Plasma histamine concentrations were not elevated after morphine nor oxycodone administration. Respiratory depression is a side effect noted with all opioids. The profile of this phenomenon is quite similar with different opioid-receptor agonists. The hemodynamic effects of opioids may vary depending on the opioid used, morphine causing a slight hemodynamic stimulation. However, all opioids studied could be considered hemodynamically stable.
Resumo:
This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.
Resumo:
Background: The rapid shallow breathing index (RSBI) is the most widely used index within intensive care units as a predictor of the outcome of weaning, but differences in measurement techniques have generated doubts about its predictive value. Objective: To investigate the influence of low levels of pressure support (PS) on the RSBI value of ill patients. Method: Prospective study including 30 patients on mechanical ventilation (MV) for 72 hours or more, ready for extubation. Prior to extubation, the RSBI was measured with the patient connected to the ventilator (Drager (TM) Evita XL) and receiving pressure support ventilation (PSV) and 5 cmH(2)O of positive end expiratory pressure or PEEP (RSBI_MIN) and then disconnected from the VM and connected to a Wright spirometer in which respiratory rate and exhaled tidal volume were recorded for 1 min (RSBI_ESP). Patients were divided into groups according to the outcome: successful extubation group (SG) and failed extubation group (FG). Results: Of the 30 patients, 11 (37%) failed the extubation process. In the within-group comparison (RSBI_MIN versus RSBI_ESP), the values for RSBI_MIN were lower in both groups: SG (34.79 +/- 4.67 and 60.95 +/- 24.64) and FG (38.64 +/- 12.31 and 80.09 +/- 20.71; p<0.05). In the between-group comparison, there was no difference in RSBI_MIN (34.79 +/- 14.67 and 38.64 +/- 12.31), however RSBI_ESP was higher in patients with extubation failure: SG (60.95 +/- 24.64) and FG (80.09 +/- 20.71; p<0.05). Conclusion: In critically ill patients on MV for more than 72h, low levels of PS overestimate the RSBI, and the index needs to be measured with the patient breathing spontaneously without the aid of pressure support.
Resumo:
Background: In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Methods: Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Results: Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. Conclusion: In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.
Resumo:
Abstract Introduction Biphasic positive airway pressure (BIVENT) is a partial support mode that employs pressure-controlled, time-cycled ventilation set at two levels of continuous positive airway pressure with unrestricted spontaneous breathing. BIVENT can modulate inspiratory effort by modifying the frequency of controlled breaths. Nevertheless, the optimal amount of inspiratory effort to improve respiratory function while minimizing ventilator-associated lung injury during partial ventilatory assistance has not been determined. Furthermore, it is unclear whether the effects of partial ventilatory support depend on acute lung injury (ALI) etiology. This study aimed to investigate the impact of spontaneous and time-cycled control breaths during BIVENT on the lung and diaphragm in experimental pulmonary (p) and extrapulmonary (exp) ALI. Methods This was a prospective, randomized, controlled experimental study of 60 adult male Wistar rats. Mild ALI was induced by Escherichia coli lipopolysaccharide either intratracheally (ALIp) or intraperitoneally (ALIexp). After 24 hours, animals were anesthetized and further randomized as follows: (1) pressure-controlled ventilation (PCV) with tidal volume (Vt) = 6 ml/kg, respiratory rate = 100 breaths/min, PEEP = 5 cmH2O, and inspiratory-to-expiratory ratio (I:E) = 1:2; or (2) BIVENT with three spontaneous and time-cycled control breath modes (100, 75, and 50 breaths/min). BIVENT was set with two levels of CPAP (Phigh = 10 cmH2O and Plow = 5 cmH2O). Inspiratory time was kept constant (Thigh = 0.3 s). Results BIVENT was associated with reduced markers of inflammation, apoptosis, fibrogenesis, and epithelial and endothelial cell damage in lung tissue in both ALI models when compared to PCV. The inspiratory effort during spontaneous breaths increased during BIVENT-50 in both ALI models. In ALIp, alveolar collapse was higher in BIVENT-100 than PCV, but decreased during BIVENT-50, and diaphragmatic injury was lower during BIVENT-50 compared to PCV and BIVENT-100. In ALIexp, alveolar collapse during BIVENT-100 and BIVENT-75 was comparable to PCV, while decreasing with BIVENT-50, and diaphragmatic injury increased during BIVENT-50. Conclusions In mild ALI, BIVENT had a lower biological impact on lung tissue compared to PCV. In contrast, the response of atelectasis and diaphragmatic injury to BIVENT differed according to the rate of spontaneous/controlled breaths and ALI etiology.
Resumo:
Objective: Adherence to Continuous Positive Airway Pressure Therapy (CPAP) for Obstructive Sleep Apnoea (OSA) is poor. We assessed the effectiveness of a motivational interviewing intervention (MINT) in addition to best practice standard care to improve acceptance and adherence to CPAP therapy in people with a new diagnosis of OSA. Method: 106 Australian adults (69% male) with a new diagnosis of obstructive sleep apnoea and clinical recommendation for CPAP treatment were recruited from a tertiary sleep disorders centre. Participants were randomly assigned to receive either three sessions of a motivational interviewing intervention ‘MINT’ (n=53; mean age=55.4 years), or no intervention ‘Control’ (n=53; mean age=57.74). The primary outcome was the difference between the groups in objective CPAP adherence at 1 month, 2 months, 3 months and 12 months follow-up. Results: Fifty (94%) participants in the MINT group and 50 (94%) of participants in the control group met all inclusion and exclusion criteria and were included in the primary analysis. The hours of CPAP use per night in the MINT group at 3 months was 4.63 hours and 3.16 hours in the control group (p=0.005). This represents almost 50% better adherence in the MINT group relative to the control group. Patients in the MINT group were substantially more likely to accept CPAP treatment. Conclusions: MINT is a brief, manualized, effective intervention which improves CPAP acceptance and objective adherence rates as compared to standard care alone.
Resumo:
Objectives Actigraphy can reliably assess sleep in healthy adults and be used to estimate total sleep time in suspected obstructive sleep apnoea (OSA) patients. We compared sleep quality for Continuous Positive Air Pressure (CPAP) treated OSA patients and controls, evaluating the impact of stopping CPAP for one night. Methods 11 men, aged 51–75 years (m = 65.6 years), compliant CPAP users, treated for 1–19 years (m = 7.8 years) wore Cambridge Neurotechnology Ltd actiwatches for one night while using CPAP and for one night sleeping without CPAP. A control group of 11 healthy men, aged 63–74 years (m = 64.1 years) slept normally whilst wearing an actiwatch. Subsequent daytime sleepiness was recorded using Karolinska sleepiness scores (KSS). Results Actimetry showed no significant differences between actual sleep time, sleep efficiency, sleep disturbance index or number of wake bouts when comparing OSA participants using CPAP, with controls; there was no difference in subsequent daytime sleepiness, control KSS = 4.21, OSA KSS = 4.17. Without CPAP there was no significant difference in sleep length or sleep onset latency compared with using CPAP, but there was a significant impact on sleep quality as shown by: increased sleep disturbance index from 7.9 to 13.8 [t(10) = 3.510, P < 0.05], decreased percent of actual sleep from 92.05% to 86.15% [t(10) = 3.51, P < 0.05], decreased sleep efficiency from 86.6% to 81% [t(10) = 2.204, P < 0.05] and increased number of wake bouts from 29 to 42.5 [t(10) = 3.877, P < 0.05]. Daytime sleepiness became significantly worse increasing from KSS 4.17 to 6.27 [t(10) = )4.96, P < 0.05]. Conclusion There was no disparity in sleep quality or KSS scores between CPAP treated OSA patients and healthy controls of a similar age. Treated OSA patients obtained quality sleep with no elevated day time sleepiness. However, cessation of treatment for one night caused sleep quality to deteriorate despite a comparable sleep time; the deterioration in sleep quality could explain the increase in daytime sleepiness. OSA patients need to know that even short-term noncompliance with CPAP treatment significantly impairs sleep quality, leading to excessive sleepiness during monotonous tasks such as driving. Actigraphy successfully identified nights of non-compliance in treated OSA patients; but did not differentiate between the sleep of CPAP treated OSA patients and healthy controls.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
BackgroundMechanical ventilation is important in caring for patients with critical illness. Clinical complications, increased mortality, and high costs of health care are associated with prolonged ventilatory support or premature discontinuation of mechanical ventilation. Weaning refers to the process of gradually or abruptly withdrawing mechanical ventilation. the weaning process begins after partial or complete resolution of the underlying pathophysiology precipitating respiratory failure and ends with weaning success (successful extubation in intubated patients or permanent withdrawal of ventilatory support in tracheostomized patients).ObjectivesTo evaluate the effectiveness and safety of two strategies, a T-tube and pressure support ventilation, for weaning adult patients with respiratory failure that required invasive mechanical ventilation for at least 24 hours, measuring weaning success and other clinically important outcomes.Search methodsWe searched the following electronic databases: Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 6); MEDLINE (via PubMed) (1966 to June 2012); EMBASE (January 1980 to June 2012); LILACS (1986 to June 2012); CINAHL (1982 to June 2012); SciELO (from 1997 to August 2012); thesis repository of CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior) (http://capesdw.capes.gov.br/capesdw/) (August 2012); and Current Controlled Trials (August 2012).We reran the search in December 2013. We will deal with any studies of interest when we update the review.Selection criteriaWe included randomized controlled trials (RCTs) that compared a T-tube with pressure support (PS) for the conduct of spontaneous breathing trials and as methods of gradual weaning of adult patients with respiratory failure of various aetiologies who received invasive mechanical ventilation for at least 24 hours.Data collection and analysisTwo authors extracted data and assessed the methodological quality of the included studies. Meta-analyses using the random-effects model were conducted for nine outcomes. Relative risk (RR) and mean difference (MD) or standardized mean difference (SMD) were used to estimate the treatment effect, with 95% confidence intervals (CI).Main resultsWe included nine RCTs with 1208 patients; 622 patients were randomized to a PS spontaneous breathing trial (SBT) and 586 to a T-tube SBT. the studies were classified into three categories of weaning: simple, difficult, and prolonged. Four studies placed patients in two categories of weaning. Pressure support ventilation (PSV) and a T-tube were used directly as SBTs in four studies (844 patients, 69.9% of the sample). in 186 patients (15.4%) both interventions were used along with gradual weaning from mechanical ventilation; the PS was gradually decreased, twice a day, until it was minimal and periods with a T-tube were gradually increased to two and eight hours for patients with difficult and prolonged weaning. in two studies (14.7% of patients) the PS was lowered to 2 to 4 cm H2O and 3 to 5 cm H2O based on ventilatory parameters until the minimal PS levels were reached. PS was then compared to the trial with the T-tube (TT).We identified 33 different reported outcomes in the included studies; we took 14 of them into consideration and performed meta-analyses on nine. With regard to the sequence of allocation generation, allocation concealment, selective reporting and attrition bias, no study presented a high risk of bias. We found no clear evidence of a difference between PS and TT for weaning success (RR 1.07, 95% CI 0.97 to 1.17, 9 studies, low quality of evidence), intensive care unit (ICU) mortality (RR 0.81, 95% CI 0.53 to 1.23, 5 studies, low quality of evidence), reintubation (RR 0.92, 95% CI 0.66 to 1.26, 7 studies, low quality evidence), ICU and long-term weaning unit (LWU) length of stay (MD -7.08 days, 95% CI -16.26 to 2.1, 2 studies, low quality of evidence) and pneumonia (RR 0.67, 95% CI 0.08 to 5.85, 2 studies, low quality of evidence). PS was significantly superior to the TT for successful SBTs (RR 1.09, 95% CI 1.02 to 1.17, 4 studies, moderate quality of evidence). Four studies reported on weaning duration, however we were unable to combined the study data because of differences in how the studies presented their data. One study was at high risk of other bias and four studies were at high risk for detection bias. Three studies reported that the weaning duration was shorter with PS, and in one study the duration was shorter in patients with a TT.Authors' conclusionsTo date, we have found evidence of generally low quality from studies comparing pressure support ventilation (PSV) and with a T-tube. the effects on weaning success, ICU mortality, reintubation, ICU and LWU length of stay, and pneumonia were imprecise. However, PSV was more effective than a T-tube for successful spontaneous breathing trials (SBTs) among patients with simple weaning. Based on the findings of single trials, three studies presented a shorter weaning duration in the group undergoing PS SBT, however a fourth study found a shorter weaning duration with a T-tube.
Resumo:
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.
Resumo:
RESUMO: A hipertensão arterial (HA) é uma patologia altamente prevalente, embora claramente subdiagnosticada, em doentes com síndrome de apneia obstrutiva do sono (SAOS). Estas duas patologias apresentam uma estreita relação e a monitorização ambulatória da pressão arterial (MAPA), por um período de 24 horas, parece ser o método mais preciso para o diagnóstico de hipertensão em doentes com SAOS. No entanto, esta ferramenta de diagnóstico para além de ser dispendiosa e envolver um número acrescido de meios técnicos e humanos, é mais morosa e, por conseguinte, não é utilizada por rotina no contexto do diagnóstico da SAOS. Por outro lado, apesar da aplicação de pressão positiva contínua nas vias aéreas (CPAP – Continous Positive Airway Pressure) ser considerada a terapêutica de eleição para os doentes com SAOS, o seu efeito no abaixamento da pressão arterial (PA) parece ser modesto, exigindo, por conseguinte, a implementação concomitante de terapêutica anti-hipertensora. Acontece que são escassos os dados relativos aos regimes de fármacos anti-hipertensores utilizados em doentes com SAOS e, acresce ainda que, as guidelines terapêuticas para o tratamento farmacológico da HA, neste grupo particular de doentes, permanecem, até ao momento, inexistentes. A utilização de modelos animais de hipóxia crónica intermitente (CIH), que mimetizam a HA observada em doentes com SAOS, revela-se extremamente importante, uma vez que se torna imperativo identificar fármacos que promovam um controle adequado da PA neste grupo de doentes. No entanto, estudos concebidos com o intuito de investigar o efeito anti-hipertensor dos fármacos neste modelo animal revelam-se insuficientes e, por outro lado, os escassos estudos que testaram fármacos anti-hipertensores neste modelo não foram desenhados para responder a questões de natureza farmacológica. Acresce ainda que se torna imprescindível garantir a escolha de um método para administração destes fármacos que seja não invasivo e que minimize o stress do animal. Embora a gavagem seja uma técnica indiscutivelmente eficaz e amplamente utilizada para a administração diária de fármacos a animais de laboratório, ela compreende uma sequência de procedimentos geradores de stress para os animais e, que podem por conseguinte, constituir um viés na interpretação dos resultados obtidos. O objectivo global da presente investigação translacional foi contribuir para a identificação de fármacos anti-hipertensores mais efectivos para o tratamento da HT nos indivíduos com SAOS e investigar mecanismos subjacentes aos efeitos sistémicos associadas à SAOS bem como a sua modulação por fármacos anti-hipertensores. Os objectivos específicos foram: em primeiro lugar,encontrar novos critérios, baseados nas medidas antropométricas, que permitam a identificação de doentes com suspeita de SAOS, que erroneamente se auto-classifiquem como nãohipertensos, e desta forma promover um uso mais criterioso do MAPA; em segundo lugar, investigar a existência de uma hipotética associação entre os esquemas de fármacos antihipertensores e o controle da PA (antes e após a adaptação de CPAP) em doentes com SAOS em terceiro lugar, avaliar a eficácia do carvedilol (CVD), um fármaco bloqueador β-adrenérgico não selectivo com actividade antagonista α1 intrínseca e propriedades anti-oxidantes num modelo animal de hipertensão induzida pela CIH; em quarto lugar, explorar os efeitos da CIH sobre o perfil farmacocinético do CVD; e, em quinto lugar, investigar um método alternativo à gavagem para a administração crónica de fármacos anti-hipertensores a animais de laboratório. Com este intuito, na primeira fase deste projecto, fizemos uso de uma amostra com um número apreciável de doentes com SAOS (n=369), que acorreram, pela primeira vez, à consulta de Patologia do Sono do CHLN e que foram submetidos a um estudo polissonográfico do sono, à MAPA e que preencheram um questionário que contemplava a obtenção de informação relativa ao perfil da medicação anti-hipertensora em curso. Numa segunda fase, utilizámos um modelo experimental de HT no rato induzida por um paradigma de CIH. Do nosso trabalho resultaram os seguintes resultados principais: em primeiro lugar, o índice de massa corporal (IMC) e o perímetro do pescoço (PP) foram identificados como preditores independentes de “auto-classificação errónea” da HA em doentes com suspeita de SAOS; em segundo lugar, não encontramos qualquer associação com significado estatístico entre os vários esquemas de fármacos anti-hipertensores bem como o número de fármacos incluídos nesse esquemas, e o controle da PA (antes e depois da adaptação do CPAP); em terceiro lugar, apesar das doses de 10, 30 e 50 mg/kg de carvedilol terem promovido uma redução significativa da frequência cardíaca, não foi observado qualquer decréscimo na PA no nosso modelo animal; em quarto lugar, as razões S/(R+S) dos enantiómeros do CVD nos animais expostos à CIH e a condições de normóxia revelaram-se diferentes; e, em quinto lugar, a administração oral voluntária mostrou ser um método eficaz para a administração diária controlada de fármacos anti-hipertensores e que é independente da manipulação e contenção do animal. Em conclusão, os resultados obtidos através do estudo clínico revelaram que o controle da PA, antes e após a adaptação do CPAP, em doentes com SAOS é independente, quer do esquema de fármacos anti-hipertensores, quer do número de fármacos incluídos num determinado esquema. Os nossos resultados salientam ainda a falta de validade da chamada self-reported hypertension e sugerem que em todos os doentes com suspeita de SAOS, com HA não diagnosticada e com um IMC e um PP acima de 27 kg/m2 e 39 cm, respectivamente, a confirmação do diagnóstico de HA deverá ser realizada através da MAPA, ao invés de outros métodos que com maior frequência são utilizados com este propósito. Os resultados obtidos no modelo animal de HA induzida pela CIH sugerem que o bloqueio do sistema nervoso simpático, juntamente com os supostos efeitos pleiotrópicos do CVD, não parece ser a estratégia mais adequada para reverter este tipo particular de hipertensão e indicam que as alterações farmacocinéticas induzidas pela CIH no ratio S/(R+S) não justificam a falta de eficácia anti-hipertensora do CVD observada neste modelo animal. Por último, os resultados do presente trabalho suportam ainda a viabilidade da utilização da administração oral voluntária, em alternativa à gavagem, para a administração crónica de uma dose fixa de fármacos anti-hipertensores.---------------------------- ABSTRACT: Hypertension (HT) is a highly prevalent condition, although under diagnosed, in patients with obstructive sleep apnea (OSA). These conditions are closely related and 24-hour ambulatory blood pressure monitoring (ABPM) seems to be the most accurate measurement for diagnosing hypertension in OSA. However, this diagnostic tool is expensive and time-consuming and, therefore, not routinely used. On the other hand, although continuous positive airway pressure (CPAP) is considered the gold standard treatment for symptomatic OSA, its lowering effect on blood pressure (BP) seems to be modest and, therefore, concomitant antihypertensive therapy is still required. Data on antihypertensive drug regimens in patients with OSA are scarce and specific therapeutic guidelines for the pharmacological treatment of hypertension in these patients remain absent. The use of animal models of CIH, which mimic the HT observed in patients with OSA, is extremely important since it is imperative to identify preferred compounds for an adequate BP control in this group of patients. However, studies aimed at investigating the antihypertensive effect of antihypertensive drugs in this animal model are insufficient, and most reports on CIH animal models in which drugs have been tested were not designed to respond to pharmacological issues. Moreover, when testing antihypertensive drugs (AHDs) it becomes crucial to ensure the selection of a non-invasive and stress-free method for drug delivery. Although gavage is effective and a widely performed technique for daily dosing in laboratory rodents, it comprises a sequence of potentially stressful procedures for laboratory animals that may constitute bias for the experimental results. The overall goal of the present translational research was to contribute to identify more effective AHDs for the treatment of hypertension in patients with OSA and investigate underlying mechanisms of systemic effects associated with OSA, as well as its modulation by AHDs. The specific aims were: first, to find new predictors based on anthropometric measures to identify patients that misclassify themselves as non-hypertensive, and thereby promote the selective use of ABPM; second, to investigate a hypothetical association between ongoing antihypertensive regimens and BP control rates in patients with OSA, before and after CPAP adaptation; third, to determine, in a rat model of CIH-induced hypertension, the efficacy of carvedilol (CVD), a nonselective beta-blocker with intrinsic anti-α1-adrenergic activity and antioxidant properties; fourth, to explore the effects of CIH on the pharmacokinetics profile of CVD and fifth, to investigate an alternative method to gavage, for chronic administration of AHDs to laboratory rats. For that, in the first phase of this project, we used a sizeable sample of patients with OSA (n=369), that attended a first visit at Centro Hospitalar Lisboa Norte, EPE Sleep Unit, and underwent overnight polysomnography, 24-h ABPM and filled a questionnaire that included ongoing antihypertensive medication profile registration. In the second phase, a rat experimental model of HT induced by a paradigm of CIH that simulates OSA was used. The main findings of this work were: first, body mass index (BMI) and neck circumference (NC) were identified as independent predictors of hypertension misclassification in patients suspected of OSA; second, in patients with OSA, BP control is independent of both the antihypertensive regimen and the number of antihypertensive drugs, either before or after CPAP adaptation; third, although the doses of 10, 30 and 50 mg/Kg of CVD promoted a significant reduction in heart rate, no decrease in mean arterial pressure was observed; fourth, the S/(R+S) ratios of CVD enantiomers, between rats exposed to CIH and normoxic conditions, were different and fifth, voluntary ingestion proved to be an effective method for a controlled daily dose administration, with a define timetable, that is independent of handling and restraint procedures. In conclusion, the clinical study showed that BP control in OSA patients is independent of both the antihypertensive regimen and the number of antihypertensive drugs. Additionally, our results highlight the lack of validity of self-reported hypertension and suggest that all patients suspected of OSA with undiagnosed hypertension and with a BMI and NC above 27 Kg/m2 and 39 cm should be screened for hypertension, through ABPM. The results attained in the rat model of HT related to CIH suggest that the blockade of the sympathetic nervous system together with the putative pleiotropic effects of carvedilol is not able to revert hypertension induced by CIH and point out that the pharmacokinetic changes induced by CIH on S/(R+S) ratio are not apparently responsible for the lack of efficacy of carvedilol in reversing this particular type of hypertension. Finally, the results here presented support the use of voluntary oral administration as a viable alternative to gavage for chronic administration of a fixed dose of AHDs.