1000 resultados para Healthcare Channel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-varying bispectra, computed using a classical sliding window short-time Fourier approach, are analyzed for scalp EEG potentials evoked by an auditory stimulus and new observations are presented. A single, short duration tone is presented from the left or the right, direction unknown to the test subject. The subject responds by moving the eyes to the direction of the sound. EEG epochs sampled at 200 Hz for repeated trials are processed between -70 ms and +1200 ms with reference to the stimulus. It is observed that for an ensemble of correctly recognized cases, the best matching timevarying bispectra at (8 Hz, 8Hz) are for PZ-FZ channels and this is also largely the case for grand averages but not for power spectra at 8 Hz. Out of 11 subjects, the only exception for time-varying bispectral match was a subject with family history of Alzheimer’s disease and the difference was in bicoherence, not biphase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to improve the retention of primary healthcare (PHC) nurses through exploring and assessing their quality of work life (QWL) and turnover intention. Design and methods: A cross-sectional survey design was used in this study. Data were collected using a questionnaire comprising four sections (Brooks’ survey of Quality of Nursing Work Life [QNWL], Anticipated Turnover Intention, open-ended questions and demographic characteristics). A convenience sample was recruited from 143 PHC centres in Jazan, Saudi Arabia. A response rate of 87% (n = 508/585) was achieved. The SPSS v17 for Windows and NVivo 8 were used for analysis purposes. Procedures and tests used in this study to analyse the quantitative data were descriptive statistics, t-test, ANOVA, General Linear Model (GLM) univariate analysis, standard multiple regression, and hierarchical multiple regression. Qualitative data obtained from responses to the open-ended questions were analysed using the NVivo 8. Findings: Quantitative findings suggested that PHC nurses were dissatisfied with their work life. Respondents’ scores ranged between 45 and 218 (mean = 139.45), which is lower than the average total score on Brooks’ Survey (147). Major influencing factors were classified under four dimensions. First, work life/home life factors: unsuitable working hours, lack of facilities for nurses, inability to balance work with family needs and inadequacy of vacations’ policy. Second, work design factors: high workload, insufficient workforce numbers, lack of autonomy and undertaking many non-nursing tasks. Third, work context factors: management practices, lack of development opportunities, and inappropriate working environment in terms of the level of security, patient care supplies and unavailability of recreation room. Finally, work world factors: negative public image of nursing, and inadequate payment. More positively, nurses were notably satisfied with their co-workers. Conversely, 40.4% (n = 205) of the respondents indicated that they intended to leave their current employment. The relationships between QWL and demographic variables of gender, age, marital status, dependent children, dependent adults, nationality, ethnicity, nursing tenure, organisational tenure, positional tenure, and payment per month were significant (p < .05). The eta squared test for these demographics indicates a small to medium effect size of the variation in QWL scores. Using the GLM univariate analysis, education level was also significantly related to the QWL (p < .05). The relationships between turnover intention and demographic variables including gender, age, marital status, dependent children, education level, nursing tenure, organisational tenure, positional tenure, and payment per month were significant (p < .05). The eta squared test for these demographics indicates a small to moderate effect size of the variation in the turnover intention scores. Using the GLM univariate analysis, the dependent adults’ variable was also significantly related to turnover intention (p < .05). Turnover intention was significantly related to QWL. Using standard multiple regression, 26% of the variance in turnover intention was explained by the QWL F (4,491), 43.71, p < .001, with R² = .263. Further analysis using hierarchical multiple regression found that the total variance explained by the model as a whole (demographics and QWL) was 32.1%, F (17.433) = 12.04, p < .001. QWL explained an additional 19% of the variance in turnover intention, after controlling for demographic variables, R squared change =.19, F change (4, 433) = 30.190, p < .001. The work context variable makes the strongest unique contribution (-.387) to explain the turnover intention, followed by the work design dimension (-.112). The qualitative findings reaffirmed the quantitative findings in terms of QWL and turnover intention. However, the home life/work life and work world dimensions were of great important to both QWL and turnover intention. The qualitative findings revealed a number of new factors that were not included in the survey questionnaire. These included being away from family, lack of family support, social and cultural aspects, accommodation facilities, transportation, building and infrastructure of PHC, nature of work, job instability, privacy at work, patients and community, and distance between home and workplace. Conclusion: Creating and maintaining a healthy work life for PHC nurses is very important to improve their work satisfaction, reduce turnover, enhance productivity and improve nursing care outcomes. Improving these factors could lead to a higher QWL and increase retention rates and therefore reinforcing the stabilisation of the nursing workforce. Significance of the research: Many countries are examining strategies to attract and retain the health care workforce, particularly nurses. This study identified factors that influence the QWL of PHC nurses as well as their turnover intention. It also determined the significant relationship between QWL and turnover intention. In addition, the present study tested Brooks’ survey of QNWL on PHC nurses for the first time. The qualitative findings of this study revealed a number of new variables regarding QWL and turnover intention of PHC nurses. These variables could be used to improve current survey instruments or to develop new research surveys. The study findings could be also used to develop and appropriately implement plans to improve QWL. This may help to enhance the home and work environments of PHC nurses, improve individual and organisational performance, and increase nurses’ commitment. This study contributes to the existing body of research knowledge by presenting new data and findings from a different country and healthcare system. It is the first of its kind in Saudi Arabia, especially in the field of PHC. It has examined the relationship between QWL and turnover intention of PHC nurses for the first time using nursing instruments. The study also offers a fresh explanation (new framework) of the relationship between QWL and turnover intention among PHC nurses, which could be used or tested by researchers in other settings. Implications for further research: Review of the extant literature reveals little in-depth research on the PHC workforce, especially in terms of QWL and organisational turnover in developing countries. Further research is required to develop a QWL tool for PHC nurses, taking into consideration the findings of the current study along with the local culture. Moreover, the revised theoretical framework of the current study could be tested in further research in other regions, countries or healthcare systems in order to identify its ability to predict the level of PHC nurses’ QWL and their intention to leave. There is a need to conduct longitudinal research on PHC organisations to gain an in-depth understanding of the determents of and changes in QWL and turnover intention of PHC nurses at various points of time. An intervention study is required to improve QWL and retention among PHC nurses using the findings of the current study. This would help to assess the impact of such strategies on reducing turnover of PHC nurses. Focusing on the location of the current study, it would be valuable to conduct another study in five years’ time to examine the percentage of actual turnover among PHC nurses compared with the reported turnover intention in the current study. Further in-depth research would also be useful to assess the impact of the local culture on the perception of expatriate nurses towards their QWL and their turnover intention. A comparative study is required between PHC centres and hospitals as well as the public and private health sector agencies in terms of QWL and turnover intention of nursing personnel. Findings may differ from sector to sector according to variations in health systems, working environments and the case mix of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion channels are membrane proteins that open and close at random and play a vital role in the electrical dynamics of excitable cells. The stochastic nature of the conformational changes these proteins undergo can be significant, however current stochastic modeling methodologies limit the ability to study such systems. Discrete-state Markov chain models are seen as the "gold standard," but are computationally intensive, restricting investigation of stochastic effects to the single-cell level. Continuous stochastic methods that use stochastic differential equations (SDEs) to model the system are more efficient but can lead to simulations that have no biological meaning. In this paper we show that modeling the behavior of ion channel dynamics by a reflected SDE ensures biologically realistic simulations, and we argue that this model follows from the continuous approximation of the discrete-state Markov chain model. Open channel and action potential statistics from simulations of ion channel dynamics using the reflected SDE are compared with those of a discrete-state Markov chain method. Results show that the reflected SDE simulations are in good agreement with the discrete-state approach. The reflected SDE model therefore provides a computationally efficient method to simulate ion channel dynamics while preserving the distributional properties of the discrete-state Markov chain model and also ensuring biologically realistic solutions. This framework could easily be extended to other biochemical reaction networks. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deprivation assessed using the index of multiple deprivation (IMD) has been shown to be an independent risk factor for 1-year mortality in outpatients with chronic obstructive pulmonary disease; COPD (Collins et al, 2010). IMD combines a number of economic and social issues (eg, health, education, employment) into one overall deprivation score, the higher the score the higher an individual's deprivation. Whilst malnutrition in COPD has been linked to increased healthcare use it is not clear if deprivation is also independently associated. This study aimed to investigate the influence of deprivation on 1-year healthcare utilisation in outpatients with COPD. IMD was established in 424 outpatients with COPD according to the geographical location for each patient's address (postcode) and related to their healthcare use in the year post-date screened (Nobel et al, 2008). Patients were routinely screened in outpatient clinics for malnutrition using the ‘Malnutrition Universal Screening Tool’, ‘MUST’ (Elia 2003); mean age 73 (SD 9.9) years; body mass index 25.8 (SD 6.3) kg/m2 with healthcare use collected 1 year from screening (Abstract P147 Table 1). Deprivation assessed using IMD (mean 15.9; SD 11.1) was found to be a significant predictor for the frequency and duration of emergency hospital admissions as well as the duration of elective hospital admission. Deprivation was also linked to reduced secondary care outpatient appointment attendance but not an increase in failure to attend and deprivation was not associated with increased disease severity, as classified by the GOLD criteria (p=0.580). COPD outpatients residing in more deprived areas experience increased hospitalisation rates but decreased outpatient appointment attendance. The underlying reason behind this disparity in healthcare use requires further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LiteSteel beam (LSB) is a new cold-formed steel hollow flange channel section produced using a patented manufacturing process involving simultaneous cold-forming and dual electric resistance welding. The LSBs are commonly used as floor joists and bearers with web openings in residential, industrial and commercial buildings. Their shear strengths are considerably reduced when web openings are included for the purpose of locating building services. Shear tests of LSBs with web openings have shown that there is up to a 60% reduction in the shear capacity due to the inclusion of web openings. Hence there is a need to improve the shear capacity of LSBs with web openings. A cost effective way to eliminate the shear capacity reduction is to attach suitable stiffeners around the web openings. Hence experimental studies were undertaken to investigate the shear behaviour and strength of LSBs with stiffened web openings. In this research, various stiffening methods using plate and LSB stiffeners attached to LSBs using both welding and screw-fastening were attempted. Our test results showed that the stiffening arrangements recommended by past research for cold-formed steel channel beams are not adequate to restore the shear strengths of LSBs with web openings. Therefore new stiffener arrangements were proposed for LSBs with web openings. This paper presents the details of this experimental study and the results including the details of the optimum stiffener details for LiteSteel beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This LiteSteel beam (LSB) is a new cold-formed steel hollow flange channel section produced using a patented manufacturing process involving simultaneous cold-forming and dual electric resistance welding. The LSBs are commonly used as floor joists and bearers with web openings in buildings. Their shear strengths are considerably reduced when web openings are included for the purpose of locating building services. Shear tests of LSBs with web openings have shown that there is up to 60% reduction in the shear capacity. Hence there is a need to improve the shear capacity of LSBs with web openings. A cost effective way to eliminate the shear capacity reduction is to stiffen the web openings using suitable stiffeners. Hence numerical studies were undertaken to investigate the shear capacity of LSBs with stiffened web openings. In this research, finite element models of LSBs with stiffened web openings in shear were developed to simulate the shear behaviour and strength of LSBs. Various stiffening methods using plate and LSB stiffeners attached to LSBs using both welding and screw-fastening were attempted. The developed models were then validated by comparing their results with experimental results and used in further studies. Both finite element and experimental results showed that the stiffening arrangements recommended by past research for cold-formed steel channel beams are not adequate to restore the shear strengths of LSBs with web openings. Therefore new stiffener arrangements were proposed for LSBs with web openings. This paper presents the details of this research project using numerical studies and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel members are increasingly used as primary structural elements in buildings due to the availability of thin and high strength steels and advanced cold-forming technologies. Cold-formed lipped channel beams (LCB) are commonly used as flexural members such as floor joists and bearers. Shear behaviour of LCBs with web openings is more complicated and their shear capacities are considerably reduced by the presence of web openings. However, limited research has been undertaken on the shear behaviour and strength of LCBs with web openings. Hence a numerical study was undertaken to investigate the shear behaviour and strength of LCBs with web openings. Finite element models of simply supported LCBs with aspect ratios of 1.0 and 1.5 were considered under a mid-span load. They were then validated by comparing their results with test results and used in a detailed parametric study. Experimental and numerical results showed that the current design rules in cold-formed steel structures design codes are very conservative for the shear design of LCBs with web openings. Improved design equations were therefore proposed for the shear strength of LCBs with web openings. This paper presents the details of this numerical study of LCBs with web openings, and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unsteady numerical simulation of Rayleigh Benard convection heat transfer from a 2D channel is performed. The oscillatory behavior is attributed to recirculation of ascending and descending flows towards the core of the channel producing organized rolled motions. Variation of the parameters such as Reynolds number, channel outlet flow area and inclination of the channel are considered. Increasing Reynolds number (for a fixed Rayleigh number), delays the generation of vortices. The reduction in the outflow area leads to the later and the less vortex generation. As the time progresses, more vortices are generated, but the reinforced mean velocity does not let the eddies to enter the core of the channel. Therefore, they attach to the wall and reduce the heat transfer area. The inclination of the channel (both positive and negative) induces the generated vortices to get closer to each other and make an enlarged vortex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel lipped channel beams (LCB) are used extensively in residential, industrial and commercial buildings as load bearing structural elements. Their shear strengths are considerably reduced when web openings are included for the purpose of locating building services. Past research has shown that the shear capacities of LCBs were reduced by up to 70% due to the inclusion of these web openings. Hence there is a need to improve the shear capacities of LCBs with web openings. A cost effective way of eliminating the detrimental effects of large web openings is to attach suitable stiffeners around the web openings and restore the original shear strength and stiffness of the LCBs. Hence detailed experimental studies were undertaken to investigate the shear behaviour and strength of LCBs with stiffened web openings. Both plate and stud stiffeners with varying sizes and thicknesses were attached to the web elements of LCBs using different screw-fastening arrangements. Simply supported test specimens of LCBs with aspect ratios of 1.0 and 1.5 were loaded at mid-span until failure. Test results showed that the plate stiffeners established using AISI recommendations are inadequate to restore the shear strengths of LCBs with web openings. Hence new stiffener arrangements have been proposed for LCBs based on experimental results. This paper presents the details of this experimental study on the shear strength of lipped channel beams with stiffened web openings, and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Emergency department (ED) crowding caused by access block is an increasing public health issue and has been associated with impaired healthcare delivery, negative patient outcomes and increased staff workload. Aim To investigate the impact of opening a new ED on patient and healthcare service outcomes. Methods A 24-month time series analysis was employed using deterministically linked data from the ambulance service and three ED and hospital admission databases in Queensland, Australia. Results Total volume of ED presentations increased 18%, while local population growth increased by 3%. Healthcare service and patient outcomes at the two pre-existing hospitals did not improve. These outcomes included ambulance offload time: (Hospital A PRE: 10 min, POST: 10 min, P < 0.001; Hospital B PRE: 10 min, POST: 15 min, P < 0.001); ED length of stay: (Hospital A PRE: 242 min, POST: 246 min, P < 0.001; Hospital B PRE: 182 min, POST: 210 min, P < 0.001); and access block: (Hospital A PRE: 41%, POST: 46%, P < 0.001; Hospital B PRE: 23%, POST: 40%, P < 0.001). Time series modelling indicated that the effect was worst at the hospital furthest away from the new ED. Conclusions An additional ED within the region saw an increase in the total volume of presentations at a rate far greater than local population growth, suggesting it either provided an unmet need or a shifting of activity from one sector to another. Future studies should examine patient decision making regarding reasons for presenting to a new or pre-existing ED. There is an inherent need to take a ‘whole of health service area’ approach to solve crowding issues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality oriented management systems and methods have become the dominant business and governance paradigm. From this perspective, satisfying customers’ expectations by supplying reliable, good quality products and services is the key factor for an organization and even government. During recent decades, Statistical Quality Control (SQC) methods have been developed as the technical core of quality management and continuous improvement philosophy and now are being applied widely to improve the quality of products and services in industrial and business sectors. Recently SQC tools, in particular quality control charts, have been used in healthcare surveillance. In some cases, these tools have been modified and developed to better suit the health sector characteristics and needs. It seems that some of the work in the healthcare area has evolved independently of the development of industrial statistical process control methods. Therefore analysing and comparing paradigms and the characteristics of quality control charts and techniques across the different sectors presents some opportunities for transferring knowledge and future development in each sectors. Meanwhile considering capabilities of Bayesian approach particularly Bayesian hierarchical models and computational techniques in which all uncertainty are expressed as a structure of probability, facilitates decision making and cost-effectiveness analyses. Therefore, this research investigates the use of quality improvement cycle in a health vii setting using clinical data from a hospital. The need of clinical data for monitoring purposes is investigated in two aspects. A framework and appropriate tools from the industrial context are proposed and applied to evaluate and improve data quality in available datasets and data flow; then a data capturing algorithm using Bayesian decision making methods is developed to determine economical sample size for statistical analyses within the quality improvement cycle. Following ensuring clinical data quality, some characteristics of control charts in the health context including the necessity of monitoring attribute data and correlated quality characteristics are considered. To this end, multivariate control charts from an industrial context are adapted to monitor radiation delivered to patients undergoing diagnostic coronary angiogram and various risk-adjusted control charts are constructed and investigated in monitoring binary outcomes of clinical interventions as well as postintervention survival time. Meanwhile, adoption of a Bayesian approach is proposed as a new framework in estimation of change point following control chart’s signal. This estimate aims to facilitate root causes efforts in quality improvement cycle since it cuts the search for the potential causes of detected changes to a tighter time-frame prior to the signal. This approach enables us to obtain highly informative estimates for change point parameters since probability distribution based results are obtained. Using Bayesian hierarchical models and Markov chain Monte Carlo computational methods, Bayesian estimators of the time and the magnitude of various change scenarios including step change, linear trend and multiple change in a Poisson process are developed and investigated. The benefits of change point investigation is revisited and promoted in monitoring hospital outcomes where the developed Bayesian estimator reports the true time of the shifts, compared to priori known causes, detected by control charts in monitoring rate of excess usage of blood products and major adverse events during and after cardiac surgery in a local hospital. The development of the Bayesian change point estimators are then followed in a healthcare surveillances for processes in which pre-intervention characteristics of patients are viii affecting the outcomes. In this setting, at first, the Bayesian estimator is extended to capture the patient mix, covariates, through risk models underlying risk-adjusted control charts. Variations of the estimator are developed to estimate the true time of step changes and linear trends in odds ratio of intensive care unit outcomes in a local hospital. Secondly, the Bayesian estimator is extended to identify the time of a shift in mean survival time after a clinical intervention which is being monitored by riskadjusted survival time control charts. In this context, the survival time after a clinical intervention is also affected by patient mix and the survival function is constructed using survival prediction model. The simulation study undertaken in each research component and obtained results highly recommend the developed Bayesian estimators as a strong alternative in change point estimation within quality improvement cycle in healthcare surveillances as well as industrial and business contexts. The superiority of the proposed Bayesian framework and estimators are enhanced when probability quantification, flexibility and generalizability of the developed model are also considered. The empirical results and simulations indicate that the Bayesian estimators are a strong alternative in change point estimation within quality improvement cycle in healthcare surveillances. The superiority of the proposed Bayesian framework and estimators are enhanced when probability quantification, flexibility and generalizability of the developed model are also considered. The advantages of the Bayesian approach seen in general context of quality control may also be extended in the industrial and business domains where quality monitoring was initially developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract—In this paper we investigate the capacity of a general class of the slotted amplify and forward (SAF) relaying protocol where multiple, though a finite number of relays may transmit in a given cooperative slot and the relay terminals being half-duplex have a finite slot memory capacity. We derive an expression for the capacity per channel use of this generalized SAF channel assuming all source to relay, relay to destination and source to destination channel gains are independent and modeled as complex Gaussian. We show through the analysis of eigenvalue distributions that the increase in limiting capacity per channel use is marginal with the increase of relay terminals.