958 resultados para Half-line


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Laparoscopic liver resections are becoming a common procedure, and bleeding remains the major concern during parenchymal transection. Total vascular inflow occlusion can be performed, but ischemic reperfusion injuries can lead to postoperative morbidity. On the other hand, hemihepatic inflow occlusion, leading to hemiliver ischemia, decreases the amount of liver parenchyma submitted to reperfusion damage and offers the advantage of reduced blood loss. Objective: The aim of this work was to describe our experience with laparoscopic the half-Pringle maneuver for segmentar or nonanatomic liver resctions. Patients and Methods: Eight patients submitted to laparoscopic liver resection in a single tertiary center. Results: There were 5 women and 3 men with a mean age of 40.2 years (range, 26-54). Mean tumor size was 4.1 cm (range, 2.6-6.0), and mean hospital stay was 3.1 days (1-5). There were 3 liver adenomas, 2 hepatocellular carcinomas, 1 metastatic melanoma, 1 metastatic colorectal carcinoma, and 1 peripheral colangiocarcinoma. No postoperative complications or mortalities were observed. Conclusions: Results demonstrate that laparoscopic liver resection with the half-Pringle maneuver is feasible and safe and may be included in the technical armamentarium of laparoscopic liver resections for a selected group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Surgical staple line dehiscence usually leads to severe complications. Several techniques and materials have been used to reinforce this stapling and thus reduce the related complications. The objective was to compare safety of two types of anastomotic reinforcement in open gastric bypass. Methods: A prospective, randomized study comparing an extraluminal suture, fibrin glue, and a nonpermanent buttressing material, Seamguard (R), for staple line reinforcement. Fibrin glue was excluded from the study and analysis after two leaks, requiring surgical reintervention, antibiotic therapy, and prolonged patient hospitalization. Results: Twenty patients were assigned to the suture and Seamguard reinforcement groups. The groups were similar in terms of preoperative characteristics. No staple line dehiscence occurred in the two groups, whereas two cases of dehiscence occurred in the fibrin glue group. No mortality occurred and surgical time was statistically similar for both techniques. Seamguard made the surgery more expensive. Conclusion: In our service, staple line reinforcement in open bariatric surgery with oversewing or Seamguard was considered to be safe. Seamguard application was considered to be easier than oversewing, but more expensive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data from the slaughter of 24,001 chickens that were part of a selection program for the production of commercial broilers were used to estimate genetic trend for absolute carcass (CW), breast meat (BRW), and leg (LW) weights, and relative carcass (CY), breast meat (BRY), and leg (LY) weights. The components of (co) variance and breeding values of individuals were obtained by the restricted maximum likelihood method applied to animal models. The relationship matrix was composed of 132,442 birds. The models included as random effects, maternal additive genetic and permanent environmental for CW, BRW, LW, CY, and BRY, and only maternal permanent environmental for LY, besides the direct additive genetic and residual effects, and as fixed effects, hatch week, parents' mating group and sex. The estimates of genetic trend were obtained by average regression of breeding value on generation, and the average genetic trend was estimated by regression coefficients. The genetic trends for CW (+ 6.0336 g/generation), BRW (+ 3.6723 g/generation), LW (+ 1.5846 g/generation), CY (+ 0.1195%/generation), and BRY (+ 0.1388%/generation) were positive, and they were in accordance with the objectives of the selection program for these traits. The genetic trend for LY(-0.0019%/generation) was negative, possibly due to the strong emphasis on selection for BRY and the negative correlations between these two traits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of genetic and non-genetic factors for carcass, breast meat and leg weights, and yields of a commercial broiler line were investigated using the restricted maximum likelihood method, considering four different animal models, including or excluding maternal genetic effect with covariance between direct and maternal genetic effects, and maternal permanent environmental effect. The likelihood ratio test was used to determine the most adequate model for each trait. For carcass, breast, and leg weight, and for carcass and breast yield, maternal genetic and permanent environmental effects as well as the covariance between direct and maternal genetic effects were significant. The estimates of direct and maternal heritability were 0.17 and 0.04 for carcass weight, 0.26 and 0.06 for breast weight, 0.22 and 0.02 for leg weight, 0.32 and 0.02 for carcass yield, and 0.52 and 0.04 for breast yield, respectively. For leg yield, maternal permanent environmental effect was important, in addition to direct genetic effects. For that trait, direct heritability and maternal permanent environmental variance as a proportion of the phenotypic variance were 0.43 and 0.02, respectively. The results indicate that ignoring maternal effects in the models, even though they were of small magnitude (0.02 to 0.06), tended to overestimate direct genetic variance and heritability for all traits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. The analysis and interpretation of the H(2) line emission from planetary nebulae have been done in the literature by assuming that the molecule survives only in regions where the hydrogen is neutral, as in photodissociation, neutral clumps, or shocked regions. However, there is strong observational and theoretical evidence that at least part of the H(2) emission is produced inside the ionized region of these objects. Aims. The aim of the present work is to calculate and analyze the infrared line emission of H(2) produced inside the ionized region of planetary nebulae using a one-dimensional photoionization code. Methods. The photoionization code Aangaba was improved in order to calculate the statistical population of the H(2) energy levels, as well as the intensity of the H(2) infrared emission lines in the physical conditions typical of planetary nebulae. A grid of models was obtained and the results then analyzed and compared with the observational data. Results. We show that the contribution of the ionized region to the H(2) line emission can be important, particularly in the case of nebulae with high-temperature central stars. This result explains why H(2) emission is more frequently observed in bipolar planetary nebulae (Gatley's rule), since this kind of object typically has hotter stars. Collisional excitation plays an important role in populating the rovibrational levels of the electronic ground state of H(2) molecules. Radiative mechanisms are also important, particularly for the upper vibrational levels. Formation pumping can have minor effects on the line intensities produced by de-excitation from very high rotational levels, especially in dense and dusty environments. We included the effect of the H(2) molecule on the thermal equilibrium of the gas, concluding that, in the ionized region, H(2) only contributes to the thermal equilibrium in the case of a very high temperature of the central star or a high dust-to-gas ratio, mainly through collisional de-excitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new insight on NGC 6034 and UGC 842, two groups of galaxies previously reported in the literature as being fossil groups. The study is based on optical photometry and spectroscopy obtained with the CTIO Blanco telescope and Sloan Digital Sky Survey archival data. We find that NGC 6034 is embedded in a large structure, dominated by three rich clusters and other small groups. Its first and next four ranked galaxies have magnitude differences in the r band and projected distances which violate the optical criteria to classify it as a fossil group. We confirm that the UGC 842 group is a fossil group, but with about half the velocity dispersion that is reported in previous works. The velocity distribution of its galaxies reveals the existence of two structures in its line of sight, one with sigma(nu) similar to 223 km s(-1) and another with sigma(nu) similar to 235 km s(-1), with a difference in velocity of similar to 820 km s(-1). The main structure is dominated by passive galaxies, while these represent similar to 60% of the second structure. The X-ray temperature for the intragroup medium of a group with such a velocity dispersion is expected to be kT similar to 0.5-1 keV, against the observed value of kT similar to 1.9 keV reported in the literature. This result makes UGC 842 a special case among fossil groups because (1) it represents more likely the interaction between two small groups, which warms the intragroup medium and/or (2) it could constitute evidence that member galaxies lost energy in the process of spiraling toward the group center, and decreased the velocity dispersion of the system. As far as we know, UGC 842 is the first low-mass fossil group studied in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. We present lithium abundance determination for a sample of K giant stars in the Galactic bulge. The stars presented here are the only 13 stars with a detectable lithium line (6767.18 angstrom) among similar to 400 stars for which we have spectra in this wavelength range, half of them in Baade's Window (b = -4 degrees) and half in a field at b = -6 degrees. Methods. The stars were observed with the GIRAFFE spectrograph of FLAMES mounted on VLT, with a spectral resolution of R similar to 20 000. Abundances were derived from spectral synthesis and the results are compared with those of stars with similar parameters, but no detectable Li line. Results. We find 13 stars with a detectable Li line, among which 2 have abundances A(Li) > 2.7. No clear correlations were found between the Li abundance and those of other elements. With the exception of the two most Li rich stars, the others follow a fairly tight A(Li) - T(eff) correlation. Conclusions. There is strong indication of a Li production phase during the red giant branch (RGB), acting either on a very short timescale, or selectively only in some stars. That the proposed Li production phase is associated with the RGB bump cannot be excluded, although our targets are significantly brighter than the predicted RGB bump magnitude for a population at 8 kpc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the sensitivity of the composite cellular automaton of H. Fuks [Phys. Rev. E 55, R2081 (1997)] to noise and assess the density classification performance of the resulting probabilistic cellular automaton (PCA) numerically. We conclude that the composite PCA performs the density classification task reliably only up to very small levels of noise. In particular, it cannot outperform the noisy Gacs-Kurdyumov-Levin automaton, an imperfect classifier, for any level of noise. While the original composite CA is nonergodic, analyses of relaxation times indicate that its noisy version is an ergodic automaton, with the relaxation times decaying algebraically over an extended range of parameters with an exponent very close (possibly equal) to the mean-field value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photoluminescence (PL) technique as a function of temperature and excitation intensity was used to study the optical properties of multiquantum wells (MQWs) of GaAs/Al(x)Ga(1-x)As grown by molecular beam epitaxy on GaAs substrates oriented in the [100], [311]A, and [311]B directions. The asymmetry presented by the PL spectra of the MQWs with an apparent exponential tail in the lower-energy side and the unusual behavior of the PL peak energy versus temperature (blueshift) at low temperatures are explained by the exciton localization in the confinement potential fluctuations of the heterostructures. The PL peak energy dependence with temperature was fitted by the expression proposed by Passler [Phys. Status Solidi B 200, 155 (1997)] by subtracting the term sigma(2)(E)/k(B)T, which considers the presence of potential fluctuations. It can be verified from the PL line shape, the full width at half maximum of PL spectra, the sigma(E) values obtained from the adjustment of experimental points, and the blueshift maximum values that the samples grown in the [311]A/B directions have higher potential fluctuation amplitude than the sample grown in the [100] direction. This indicates a higher degree of the superficial corrugations for the MQWs grown in the [311] direction. (C) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the discovery with XMM-Newton of a hard-thermal (T similar to 130 MK) and variable X-ray emission from the Be star HD 157832, a new member of the puzzling class of gamma-Cas-like Be/X-ray systems. Recent optical spectroscopy reveals the presence of a large/dense circumstellar disk seen at intermediate/high inclination. With a B1.5V spectral type, HD 157832 is the coolest gamma-Cas analog known. In addition, its non-detection in the ROSAT all-sky survey shows that its average soft X-ray luminosity varied by a factor larger than similar to 3 over a time interval of 14 yr. These two remarkable features, ""low"" effective temperature, and likely high X-ray variability turn HD 157832 into a promising object for understanding the origin of the unusually high-temperature X-ray emission in these systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We construct a family of examples of increasing homeomorphisms of the real line whose local quasi-symmetric distortion blows up almost everywhere, which nevertheless can be realized as the boundary values of David homeomorphisms of the upper half-plane. The construction of such David extensions uses Carleson boxes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exploitation of aqueous biphasic extraction is proposed for the first time in flow analysis This extraction strategy stands out for being environmentally attractive since it is based in the utilization of two immiscible phases that are intrinsically aqueous The organic solvents of the traditional liquid-liquid extractions ale no longer used, being replaced by non-toxic, non-flammable and non-volatile ones. A single interface flow analysis (SIFA) system was implemented to carry out the extraction process due to its favourable operational characteristics that include the high automation level and simplicity of operation, the establishment of a dynamic interface where the mass transfer occurred between the two immiscible aqueous phases, and the versatile control over the extraction process namely the extraction time The application selected to demonstrate the feasibility of SIFA to perform this aqueous biphasic extraction was the pre-concentration of lead. After extraction, lead reacted with 8-hydroxyquinoline-5-sulfonic acid and the resulting product was determined by a fluorimetric detector included in the flow manifold. Therefore, the SIFA single interface was used both as extraction (enrichment) and reaction interface. (C) 2010 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-pumping flow system exploiting prior assay is proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods are implemented in the same manifold that provides facilities for: in-line sample clean-up with a Bio-Rex 70 mini-column with fluidized beads: addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation; analyte precipitation with Ba(2+) or Ag(+); real-time decision on the need for next assay. The sample is initially run for chloride determination, and the analytical signal is compared with a preset value. If higher, the sample is run again, now for sulphate determination. The strategy may lead to all increased sample throughput. The proposed system is computer-controlled and presents enhanced figures of merit. About 10 samples are run per hour (about 60 measurements) and results are reproducible and Unaffected by the presence of potential interfering ions at concentration levels usually found in natural waters. Accuracy was assessed against ion chromatography. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This investigation presents a comprehensive characterization of magnetic and transport properties of an interesting superconducting wire, Nb-Ti -Ta, obtained through the solid-state diffusion between Nb-12 at.% Ta alloy and pure Ti. The physical properties obtained from magnetic and transport measurements related to the microstructure unambiguously confirmed a previous proposition that the superconducting currents flow in the center of the diffusion layer, which has a steep composition variation. The determination of the critical field also confirmed that the flux line core size is not constant, and in addition it was possible to determine that, in the center of the layer, the flux line core is smaller than at the borders. A possible core shape design is proposed. Among the wires studied, the one that presented the best critical current density was achieved for a diffusion layer with a composition of about Nb-32% Ti-10% Ta, obtained with a heat treatment at 700 degrees C during 120 h, in agreement with previous studies. It was determined that this wire has the higher upper critical field, indicating that the optimization of the superconducting behavior is related to an intrinsic property of the ternary alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.