985 resultados para HARD-PHOTON EMISSION


Relevância:

80.00% 80.00%

Publicador:

Resumo:

On-board image guidance, such as cone-beam CT (CBCT) and kV/MV 2D imaging, is essential in many radiation therapy procedures, such as intensity modulated radiotherapy (IMRT) and stereotactic body radiation therapy (SBRT). These imaging techniques provide predominantly anatomical information for treatment planning and target localization. Recently, studies have shown that treatment planning based on functional and molecular information about the tumor and surrounding tissue could potentially improve the effectiveness of radiation therapy. However, current on-board imaging systems are limited in their functional and molecular imaging capability. Single Photon Emission Computed Tomography (SPECT) is a candidate to achieve on-board functional and molecular imaging. Traditional SPECT systems typically take 20 minutes or more for a scan, which is too long for on-board imaging. A robotic multi-pinhole SPECT system was proposed in this dissertation to provide shorter imaging time by using a robotic arm to maneuver the multi-pinhole SPECT system around the patient in position for radiation therapy.

A 49-pinhole collimated SPECT detector and its shielding were designed and simulated in this work using the computer-aided design (CAD) software. The trajectories of robotic arm about the patient, treatment table and gantry in the radiation therapy room and several detector assemblies such as parallel holes, single pinhole and 49 pinholes collimated detector were investigated. The rail mounted system was designed to enable a full range of detector positions and orientations to various crucial treatment sites including head and torso, while avoiding collision with linear accelerator (LINAC), patient table and patient.

An alignment method was developed in this work to calibrate the on-board robotic SPECT to the LINAC coordinate frame and to the coordinate frames of other on-board imaging systems such as CBCT. This alignment method utilizes line sources and one pinhole projection of these line sources. The model consists of multiple alignment parameters which maps line sources in 3-dimensional (3D) space to their 2-dimensional (2D) projections on the SPECT detector. Computer-simulation studies and experimental evaluations were performed as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise and acquisition geometry. In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, the six alignment parameters (3 translational and 3 rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by Radon transform, the estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution and detector acquisition geometry. The estimation accuracy was significantly improved by using 4 line sources rather than 3 and also by using thinner line-source projections (obtained by better intrinsic detector resolution). With 5 line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.

Simulation studies were performed to investigate the improvement of imaging sensitivity and accuracy of hot sphere localization for breast imaging of patients in prone position. A 3D XCAT phantom was simulated in the prone position with nine hot spheres of 10 mm diameter added in the left breast. A no-treatment-table case and two commercial prone breast boards, 7 and 24 cm thick, were simulated. Different pinhole focal lengths were assessed for root-mean-square-error (RMSE). The pinhole focal lengths resulting in the lowest RMSE values were 12 cm, 18 cm and 21 cm for no table, thin board, and thick board, respectively. In both no table and thin board cases, all 9 hot spheres were easily visualized above background with 4-minute scans utilizing the 49-pinhole SPECT system while seven of nine hot spheres were visible with the thick board. In comparison with parallel-hole system, our 49-pinhole system shows reduction in noise and bias under these simulation cases. These results correspond to smaller radii of rotation for no-table case and thinner prone board. Similarly, localization accuracy with the 49-pinhole system was significantly better than with the parallel-hole system for both the thin and thick prone boards. Median localization errors for the 49-pinhole system with the thin board were less than 3 mm for 5 of 9 hot spheres, and less than 6 mm for the other 4 hot spheres. Median localization errors of 49-pinhole system with the thick board were less than 4 mm for 5 of 9 hot spheres, and less than 8 mm for the other 4 hot spheres.

Besides prone breast imaging, respiratory-gated region-of-interest (ROI) imaging of lung tumor was also investigated. A simulation study was conducted on the potential of multi-pinhole, region-of-interest (ROI) SPECT to alleviate noise effects associated with respiratory-gated SPECT imaging of the thorax. Two 4D XCAT digital phantoms were constructed, with either a 10 mm or 20 mm diameter tumor added in the right lung. The maximum diaphragm motion was 2 cm (for 10 mm tumor) or 4 cm (for 20 mm tumor) in superior-inferior direction and 1.2 cm in anterior-posterior direction. Projections were simulated with a 4-minute acquisition time (40 seconds per each of 6 gates) using either the ROI SPECT system (49-pinhole) or reference single and dual conventional broad cross-section, parallel-hole collimated SPECT. The SPECT images were reconstructed using OSEM with up to 6 iterations. Images were evaluated as a function of gate by profiles, noise versus bias curves, and a numerical observer performing a forced-choice localization task. Even for the 20 mm tumor, the 49-pinhole imaging ROI was found sufficient to encompass fully usual clinical ranges of diaphragm motion. Averaged over the 6 gates, noise at iteration 6 of 49-pinhole ROI imaging (10.9 µCi/ml) was approximately comparable to noise at iteration 2 of the two dual and single parallel-hole, broad cross-section systems (12.4 µCi/ml and 13.8 µCi/ml, respectively). Corresponding biases were much lower for the 49-pinhole ROI system (3.8 µCi/ml), versus 6.2 µCi/ml and 6.5 µCi/ml for the dual and single parallel-hole systems, respectively. Median localization errors averaged over 6 gates, for the 10 mm and 20 mm tumors respectively, were 1.6 mm and 0.5 mm using the ROI imaging system and 6.6 mm and 2.3 mm using the dual parallel-hole, broad cross-section system. The results demonstrate substantially improved imaging via ROI methods. One important application may be gated imaging of patients in position for radiation therapy.

A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150-L110 robot). An imaging study was performed with a phantom (PET CT PhantomTM), which includes 5 spheres of 10, 13, 17, 22 and 28 mm in diameter. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single-pinhole collimator both without background in the phantom, and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180 degrees and 228 degrees respectively. The pinhole detector viewed a 14.7 cm-diameter common volume which encompassed the 28 mm and 22 mm spheres. The common volume for parallel-hole was a 20.8-cm-diameter cylinder which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the flat-top table while avoiding collision with the table and maintaining the closest possible proximity to the common volume. For image reconstruction, detector trajectories were described by radius-of-rotation and detector rotation angle θ. These reconstruction parameters were obtained from the robot base and tool coordinates. The robotic SPECT system was able to maneuver the parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector to center-of-rotation (COR) distance. In no background case, all five spheres were visible in the reconstructed parallel-hole and pinhole images. In with background case, three spheres of 17, 22 and 28 mm diameter were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameter) were readily observed in the pinhole ROI imaging.

In conclusion, the proposed on-board robotic SPECT can be aligned to LINAC/CBCT with a single pinhole projection of the line-source phantom. Alignment parameters can be estimated using one pinhole projection of line sources. This alignment method may be important for multi-pinhole SPECT, where relative pinhole alignment may vary during rotation. For single pinhole and multi-pinhole SPECT imaging onboard radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC. In simulation studies of prone breast imaging and respiratory-gated lung imaging, the 49-pinhole detector showed better tumor contrast recovery and localization in a 4-minute scan compared to parallel-hole detector. On-board SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Preclinical imaging has a critical role in phenotyping, in drug discovery, and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review high-resolution computed tomography (CT) also known as micro-CT for small-animal imaging. We present the principles, the technologies, the image quality parameters, and the types of applications. We show that micro-CT can be used to provide not only morphological but also functional information such as cardiac function or vascular permeability. Another way in which micro-CT can be used in the study of both function and anatomy is by combining it with other imaging modalities, such as positron emission tomography or single-photon emission tomography. Compared to other modalities, micro-CT imaging is usually regarded as being able to provide higher throughput at lower cost and higher resolution. The limitations are usually associated with the relatively poor contrast mechanisms and the radiation damage, although the use of novel nanoparticle-based contrast agents and careful design of studies can address these limitations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.

The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.

The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.

Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.

Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Experimental and theoretical studies of one-electron capture in collisions of He2+ ions with H2O molecules have been carried out in the range 0.025-12 keV amu(-1) corresponding to typical solar wind velocities of 70-1523 km s(-1). Translational energy spectroscopy (TES), photon emission spectroscopy (PES), and fragment ion spectroscopy were employed to identify and quantify the collision mechanisms involved. Cross sections for selective single electron capture into n=1, 2, and 3 states of the He+ ion were obtained using TES while PES provided cross sections for capture into the He+(2p) and He+(3p) states. Our model calculations show that He+(n=2) and He+(n=3) formation proceeds via a single-electron process governed by the nucleus-electron interaction. In contrast, the He+(1s) formation mechanism involves an exothermic two-electron process driven by the electron-electron interaction, where the potential energy released by the electron capture is used to remove a second electron thereby resulting in fragmentation of the H2O molecule. This process is found to become increasingly important as the collision energy decreases. The experimental cross sections are found to be in reasonable agreement with cross sections calculated using the Demkov and Landau-Zener models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Translational energy spectroscopy (TES) has been used to study state-selective one-electron capture by H and He-like ions of C, N and O in both H and H-2 within the range 250-900 eV amu(- 1). The main collision mechanisms leading to state-selective electron capture have been identified, their relative importance assessed and compared, where possible, with theoretical predictions and with any previous measurements based on photon emission spectroscopy. For one-electron capture in H-2, the relative importance of contributions from non- dissociative and dissociative capture as well as from two- electron capture into autoionizing states is found to be strikingly different for the cases considered. Our TES measurements in atomic hydrogen provide an important extension of previous measurements to energies below 1000 eV amu(-1) and show that, as the impact energy decreases, electron capture becomes more selective until only a single n product channel is significant. These product main channels are well described by reaction windows calculated using a Landau-Zener approach. However, the same approach applied to the more complex energy- change spectra observed in H-2 is found to be less successful.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Highly excited eigenstates of atoms and ions with open f shell are chaotic superpositions of thousands, or even millions, of Hartree-Fock determinant states. The interaction between dielectronic and multielectronic configurations leads to the broadening of dielectronic recombination resonances and relative enhancement of photon emission due to opening of thousands of radiative decay channels. The radiative yield is close to 100% for electron energy <1 eV and rapidly decreases for higher energies due to opening of many autoionization channels. The same mechanism predicts suppression of photoionization and relative enhancement of the Raman scattering. Results of our calculations of the recombination rate are in agreement with the experimental data for W20+ and Au25+.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We test current numerical implementations of laser-matter interactions by comparison with exact analytical results. Focusing on photon emission processes, it is found that the numerics accurately reproduce analytical emission spectra in all considered regimes, except for the harmonic structures often singled out as the most significant high-intensity (multiphoton) effects. We find that this discrepancy originates in the use of the locally constant field approximation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present the Fortran program SIMLA, which is designed for the study of charged particle dynamics in laser and other background fields. The dynamics can be determined classically via the Lorentz force and Landau–Lifshitz equations or, alternatively, via the simulation of photon emission events determined by strong-field quantum-electrodynamics amplitudes and implemented using Monte-Carlo routines. Multiple background fields can be included in the simulation and, where applicable, the propagation direction, field type (plane wave, focussed paraxial, constant crossed, or constant magnetic), and time envelope of each can be independently specified.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We apply time-dependent R-matrix theory to study inner-shell ionization of C atoms in ultra-short high-frequency light fields with a photon energy between 170 and 245 eV. At an intensity of 1017 W/cm2, ionization is dominated by single-photon emission of a 2l electron, with two-photon emission of a 1s electron accounting for about 2-3% of all emission processes, and two-photon emission of 2l contributing about 0.5-1%. Three-photon emission of a 1s electron is estimated to contribute about 0.01-0.03%. Around a photon energy of 225 eV, two-photon emission of a 1s electron, leaving C+ in either 1s2s2p3 or 1s2p4 is resonantly enhanced by intermediate 1s2s22p3 states. The results demonstrate the capability of time-dependent R-matrix theory to describe inner-shell ionization processes including rearrangement of the outer electrons.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le trouble comportemental en sommeil paradoxal (TCSP) se caractérise par une perte de l’atonie musculaire en sommeil paradoxal et par des manifestations motrices élaborées souvent associées au contenu onirique. Le TCSP peut apparaître sous une forme idiopathique (TCSPi), mais il est fréquemment lié à certains désordres neurodégénératifs, dont les synucléinopathies. Des marqueurs biologiques des synucléinopathies, tels que la présence d’anomalies au plan de la motricité, de la détection des odeurs ainsi que de la discrimination des couleurs, ont été retrouvés dans le TCSPi. De plus, des perturbations de l’activité cérébrale en neuroimagerie ainsi que du fonctionnement cognitif ont été observées chez ces patients. Des études ont démontré que le TCSPi pouvait précéder l’apparition d’une maladie de Parkinson (MP) ou d’une démence à corps de Lewy (DCL). Ceci suggère que le TCSPi représenterait un facteur de risque des synucléinopathies. L’objectif principal du présent projet est d’étudier les anomalies du débit sanguin cérébral régional (DSCr) de repos avec la tomographie par émission monophotonique (TEM) dans le TCSPi. Deux études ont été réalisées. La première visait à comparer le DSCr entre des patients avec un TCSPi et des sujets sains, puis d’explorer la relation entre l’activité cérébrale et la présence de marqueurs biologiques des synucléinopathies. Les résultats ont montré une diminution de la perfusion cérébrale dans les régions frontales et pariétales ainsi qu’une augmentation de la perfusion au niveau du pont, du putamen et des hippocampes chez les patients avec un TCSPi. Une relation significative entre la performance des sujets avec un TCSPi à une épreuve de discrimination des couleurs et la perfusion cérébrale au niveau des régions frontales et occipitales a été mise en évidence. Dans l’ensemble, ces résultats ont démontré des anomalies du DSCr chez les patients avec un TCSPi qui sont similaires à celles observées par d’autres études en neuroimagerie dans la MP. Ceci suggère des atteintes neuroanatomiques semblables entre ces pathologies. La seconde étude en TEM a été effectuée dans le but d’examiner les modifications du DSCr associées aux perturbations du fonctionnement cognitif dans le TCSPi. Pour ce faire, le DSCr a été comparé entre un sous-groupe de patients avec un TCSPi et un trouble cognitif léger (TCL), un sous-groupe de patients avec un TCSPi sans TCL et un groupe de sujets sains. Les résultats ont montré que seuls les patients avec un TCSPi et un TCL présentaient une diminution de la perfusion cérébrale dans les aires corticales postérieures (occipitales et temporo-pariétales). Ces observations sont similaires à celles rapportées dans la MP avec démence et la DCL dans les études en neuroimagerie. En conclusion, les résultats de ces deux études ont montré des perturbations du DSCr dans le TCSPi, similaires à celles observées dans les synucléinopathies. Par ailleurs, nos résultats ont mis en évidence que les patients avec un TCSPi et un TCL présentaient les mêmes anomalies de la perfusion cérébrale que les patients avec une MP avec démence et/ou une DCL. La présence de tels marqueurs des synucléinopathies dans le TCSPi suggère que ces patients pourraient être plus à risque d’évoluer vers ce type de maladie neurodégénérative.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L'épilepsie constitue le désordre neurologique le plus fréquent après les maladies cérébrovasculaires. Bien que le contrôle des crises se fasse généralement au moyen d'anticonvulsivants, environ 30 % des patients y sont réfractaires. Pour ceux-ci, la chirurgie de l'épilepsie s'avère une option intéressante, surtout si l’imagerie par résonance magnétique (IRM) cérébrale révèle une lésion épileptogène bien délimitée. Malheureusement, près du quart des épilepsies partielles réfractaires sont dites « non lésionnelles ». Chez ces patients avec une IRM négative, la délimitation de la zone épileptogène doit alors reposer sur la mise en commun des données cliniques, électrophysiologiques (EEG de surface ou intracrânien) et fonctionnelles (tomographie à émission monophotonique ou de positrons). La faible résolution spatiale et/ou temporelle de ces outils de localisation se traduit par un taux de succès chirurgical décevant. Dans le cadre de cette thèse, nous avons exploré le potentiel de trois nouvelles techniques pouvant améliorer la localisation du foyer épileptique chez les patients avec épilepsie focale réfractaire considérés candidats potentiels à une chirurgie d’épilepsie : l’IRM à haut champ, la spectroscopie proche infrarouge (SPIR) et la magnétoencéphalographie (MEG). Dans une première étude, nous avons évalué si l’IRM de haut champ à 3 Tesla (T), présentant théoriquement un rapport signal sur bruit plus élevé que l’IRM conventionnelle à 1,5 T, pouvait permettre la détection des lésions épileptogènes subtiles qui auraient été manquées par cette dernière. Malheureusement, l’IRM 3 T n’a permis de détecter qu’un faible nombre de lésions épileptogènes supplémentaires (5,6 %) d’où la nécessité d’explorer d’autres techniques. Dans les seconde et troisième études, nous avons examiné le potentiel de la SPIR pour localiser le foyer épileptique en analysant le comportement hémodynamique au cours de crises temporales et frontales. Ces études ont montré que les crises sont associées à une augmentation significative de l’hémoglobine oxygénée (HbO) et l’hémoglobine totale au niveau de la région épileptique. Bien qu’une activation contralatérale en image miroir puisse être observée sur la majorité des crises, la latéralisation du foyer était possible dans la plupart des cas. Une augmentation surprenante de l’hémoglobine désoxygénée a parfois pu être observée suggérant qu’une hypoxie puisse survenir même lors de courtes crises focales. Dans la quatrième et dernière étude, nous avons évalué l’apport de la MEG dans l’évaluation des patients avec épilepsie focale réfractaire considérés candidats potentiels à une chirurgie. Il s’est avéré que les localisations de sources des pointes épileptiques interictales par la MEG ont eu un impact majeur sur le plan de traitement chez plus des deux tiers des sujets ainsi que sur le devenir postchirurgical au niveau du contrôle des crises.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La stimulation du nerf vague (SNV) a reçu l’approbation de Santé Canada en 2001, comme en Europe, pour le traitement de la dépression réfractaire et en 2005 aux États-Unis. Les études européennes et américaines rapportent un taux de réponse de 50% et de rémission de 30% après un an de traitement. La sélection des patients, encadrée par la recherche de marqueurs biologiques et des critères de résistance, pourrait contribuer à améliorer les taux de réponse. Cette étude décrit le suivi des patients ambulatoires souffrant de dépression réfractaire, d’un spectre unipolaire ou bipolaire (n=13) sous SNV. Une révision exhaustive de l’histoire médicale et thérapeutique précède une évaluation clinique intensive. Si un consensus d’équipe est obtenu, une investigation clinique à la recherche des marqueurs biologiques est effectuée. Ceci inclut une tomographie par émission de photons simples (SPECT), une tomographie par émission de positrons (TEP), une formule sanguine complète, un test de suppression à la dexaméthasone (DST), une collecte d’urine 24h (catécholamines et cortisol), une polysomnographie et une évaluation neuropsychologique abrégée. Après 1 an de traitement, 61,5% (8/13) des patients ont atteint le seuil de réponse (diminution de 50% des symptômes), dont 87.5% (7/8) en rémission. Les patients diagnostiqués d’un trouble bipolaire, présentant un DST anormal et/ou avec déficits cognitifs ont répondu au traitement et poursuivent leur rémission après 2 ans. Une sélection minutieuse des patients pour le SNV serait une méthode efficace pour traiter les dépressions réfractaires, notamment pour prévenir les rechutes, amenant un état euthymique durable pour la plupart des patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We show how macroscopic manifestations of P (and T) symmetry breaking can arise in a simple system subject to Aharonov-Bohm interactions. Specifically, we study the conductivity of a gas of charged particles moving through a dilute array of flux tubes. The interaction of the electrons with the flux tubes is taken to be of a purely Aharonov-Bohm type. We find that the system exhibits a nonzero transverse conductivity, i.e., a spontaneous Hall effect. This is in contrast to the fact that the cross sections for both scattering and bremsstrahlung (soft-photon emission) of a single electron from a flux tube are invariant under reflections. We argue that the asymmetry in the conductivity coefficients arises from many-body effects. On the other hand, the transverse conductivity has the same dependence on universal constants that appears in the quantum Hall effect, a result that we relate to the validity of the mean-field approximation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Propósito de la revisión: la enfermedad de Parkinson (EP) es un trastorno degenerativo caracterizado clínicamente por presentar temblor en reposo, rigidez y bradicinesia. El propósito es determinar la utilidad de la molécula TRODAT-1 en el diagnóstico de la EP. Metodología: se realizó una búsqueda en las bases de datos: PUBMED, COCHRANE, MEDLINE, LILACS y SCIELO en un período de 10 años desde enero de 1998 a enero de 2008. Se obtuvieron 26 artículos, estos se analizaron y se seleccionaron 10 artículos, de los cuales sólo 6 respondían a las necesidades del estudio, de acuerdo a los criterios de inclusión. De los 6 artículos analizados, 4 fueron clasificados como evidencia grado (+) y los 2 restantes evidencia grado (-) de acuerdo con las guías NICE. Todos los artículos revisados reportan una disminución importante en la captación del TRODAT-1 a nivel estriatal, su utilidad en el diagnóstico de EP en estadios tempranos, bajo costo y seguridad. Sólo tres reportan valores de sensibilidad y especificidad, pero su nivel de calidad no permite hacer una comparación de los mismos. Conclusiones: se propone realizar estudios de prueba diagnóstica comparados con el diagnóstico clínico de la enfermedad, que tengan un acuerdo en la forma de plantear las mediciones semicuantitativas de las unidades de captación utilizando las mismas fórmulas para hacerlos comparables.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In positron emission tomography and single photon emission computed tomography studies using D2 dopamine (DA) receptor radiotracers, a decrease in radiotracer binding potential (BP) is usually interpreted in terms of increased competition with synaptic DA. However, some data suggest that this signal may also reflect agonist (DA)-induced increases in D2 receptor (D2R) internalization, a process which would presumably also decrease the population of receptors available for binding to hydrophilic radioligands. To advance interpretation of alterations in D2 radiotracer BP, direct methods of assessment of D2R internalization are required. Here, we describe a confocal microscopy-based approach for the quantification of agonist-dependent receptor internalization. The method relies upon double-labeling of the receptors with antibodies directed against intracellular as well as extracellular epitopes. Following agonist stimulation, DA D2R internalization was quantified by differentiating, in optical cell sections, the signal due to the staining of the extracellular from intracellular epitopes of D2Rs. Receptor internalization was increased in the presence of the D2 agonists DA and bromocriptine, but not the D1 agonist SKF38393. Pretreatment with either the D2 antagonist sulpiride, or inhibitors of internalization (phenylarsine oxide and high molarity sucrose), blocked D2-agonist induced receptor internalization, thus validating this method in vitro. This approach therefore provides a direct and streamlined methodology for investigating the pharmacological and mechanistic aspects of D2R internalization, and should inform the interpretation of results from in vivo receptor imaging studies.