243 resultados para Granollers WWTP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water is a limited resource for which demand is growing. Contaminated water from inadequate wastewater treatment provides one of the greatest health challenges as it restricts development and increases poverty in emerging and developing countries. Therefore, the connection between wastewater and human health is linked to access to sanitation and to human waste disposal. Adequate sanitation is expected to create a barrier between disposed human excreta and sources of drinking water. Different approaches to wastewater management are required for different geographical regions and different stages of economic governance depending on the capacity to manage wastewater. Effective wastewater management can contribute to overcome the challenges of water scarcity. Separate collection of human urine at its source is one promising approach that strongly reduces the economic and load demands on wastewater treatment plants (WWTP). Treatment of source-separated urine appears as a sanitation system that is affordable, produces a valuable fertiliser, reduces pollution of water resources and promotes health. However, the technical realisation of urine separation still faces challenges. Biological hydrolysis of urea causes a strong increase of ammonia and pH. Under these conditions ammonia volatilises which can cause odour problems and significant nitrogen losses. The above problems can be avoided by urine stabilisation. Biological nitrification is a suitable process for stabilisation of urine. Urine is a highly concentrated nutrient solution which can lead to strong inhibition effects during bacterial nitrification. This can further lead to process instabilities. The major cause of instability is accumulation of the inhibitory intermediate compound nitrite, which could lead to process breakdown. Enhanced on-line nitrite monitoring can be applied in biological source-separated urine nitrification reactors as a sustainable and efficient way to improve the reactor performance, avoiding reactor failures and eventual loss of biological activity. Spectrophotometry appears as a promising candidate for the development and application of on-line nitrite monitoring. Spectroscopic methods together with chemometrics are presented in this work as a powerful tool for estimation of nitrite concentrations. Principal component regression (PCR) is applied for the estimation of nitrite concentrations using an immersible UV sensor and off-line spectra acquisition. The effect of particles and the effect of saturation, respectively, on the UV absorbance spectra are investigated. The analysis allows to conclude that (i) saturation has a substantial effect on nitrite estimation; (ii) particles appear to have less impact on nitrite estimation. In addition, improper mixing together with instabilities in the urine nitrification process appears to significantly reduce the performance of the estimation model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enhanced biological phosphorus removal (EBPR) is the most economic and sustainable option used in wastewater treatment plants (WWTPs) for phosphorus removal. In this process it is important to control the competition between polyphosphate accumulating organisms (PAOs) and glycogen accumulating organisms (GAOs), since EBPR deterioration or failure can be related with the proliferation of GAOs over PAOs. This thesis is focused on the effect of operational conditions (volatile fatty acid (VFA) composition, dissolved oxygen (DO) concentration and organic carbon loading) on PAO and GAO metabolism. The knowledge about the effect of these operational conditions on EBPR metabolism is very important, since they represent key factors that impact WWTPs performance and sustainability. Substrate competition between the anaerobic uptake of acetate and propionate (the main VFAs present in WWTPs) was shown in this work to be a relevant factor affecting PAO metabolism, and a metabolic model was developed that successfully describes this effect. Interestingly, the aerobic metabolism of PAOs was not affected by different VFA compositions, since the aerobic kinetic parameters for phosphorus uptake, polyhydroxyalkanoates (PHAs) degradation and glycogen production were relatively independent of acetate or propionate concentration. This is very relevant for WWTPs, since it will simplify the calibration procedure for metabolic models, facilitating their use for full-scale systems. The DO concentration and aerobic hydraulic retention time (HRT) affected the PAO-GAO competition, where low DO levels or lower aerobic HRT was more favourable for PAOs than GAOs. Indeed, the oxygen affinity coefficient was significantly higher for GAOs than PAOs, showing that PAOs were far superior at scavenging for the often limited oxygen levels in WWTPs. The operation of WWTPs with low aeration is of high importance for full-scale systems, since it decreases the energetic costs and can potentially improve WWTP sustainability. Extended periods of low organic carbon load, which are the most common conditions that exist in full-scale WWTPs, also had an impact on PAO and GAO activity. GAOs exhibited a substantially higher biomass decay rate as compared to PAOs under these conditions, which revealed a higher survival capacity for PAOs, representing an advantage for PAOs in EBPR processes. This superior survival capacity of PAOs under conditions more closely resembling a full-scale environment was linked with their ability to maintain a residual level of PHA reserves for longer than GAOs, providing them with an effective energy source for aerobic maintenance processes. Overall, this work shows that each of these key operational conditions play an important role in the PAO-GAO competition and should be considered in WWTP models in order to improve EBPR processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phosphorus is a macronutrient essential to life which comes from phosphate rock, a non-renewable resource. Sewage sludge from wastewater treatment plants (WWTP) is a secondary resource rich in phosphorus that can be valorized. However, organic compounds are detected in sewage sludge, due to its non-polar and hydrophobic character, being considered an environmental risk. The present dissertation aims to study the efficiency of the electrodialytic process (ED) when applied to sewage sludge aiming phosphorus recovery and organic contaminants removal. Four organic compounds were analyzed: 17α-ethynylestradiol (EE2), bisphenol A (BPA), caffeine (Caf) and oxybenzone (MBPh). The experiments took place in an ED cell with two compartments and an anion exchange membrane, with the sludge in the cathode compartment. The experiments were carried out for three days with spiked sewage sludge (six assays). One control experiment was done without current, three experiments were carried out applying a constant current of 50, 75, and 100 mA and two experiments were carried out applying sequential currents: 50 mA, 75 mA and 100 mA and the opposite (100-75-50 mA). A qualitative and quantitative analysis of microorganisms existing in the samples was also done. At the end, the pH increased in the sewage sludge favoring phosphorus recovery. In terms of phosphorus, the highest recovery was achieved in the experiment run with 100 mA, where 70.3±2.0% of total phosphorus was recovered in the electrolyte. Generally, compounds degradation was favored by the current. Caf and MBPh achieved degradation percentages of 96.2±0.2% and 84.8±1.3%, respectively, in 100 mA assay. EE2 (83.1±1.7%) and BPA (91.8±4.6%) degradations were favored by 50 mA current. A total of 35 taxa from four different groups were identified, totalizing between 81,600-273,000 individuals per gram of initial sludges. After ED, microbial community population decreased between 47-98%. Arcella gibbosa represented 61% of the total observed organisms and revealed to be more tolerant to medium changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pharmaceuticals and personal care products (PPCPs) are widely used on a daily basis. After their usage they reach the wastewater treatment plants (WWTPs). These compounds have different physico-chemical characteristics, which makes them difficult to completely remove in the WWTPs, througth conventional treatments. Currently, there is no legislation regarding PPCPs thresholds in effluent discharge. But, even at vestigial concentrations, these compounds enclose environmental risks due to, e.g., endocrine disruption potential. There is a need of alternative techniques for their removal in WWTPs. The main goal of this work was to assess the use of electrodialytic (ED) process to remove PPCPs from the effluent to be discharged. A two-compartment ED cell was used testing (i) the effluent position in the cell (anode and cathode compartment); (ii) the use of anion (AEM) and cation exchange membrane (CEM); (iii) the treatment period (6, 12 and 24 hours); (iv) effluent recirculation and current steps; (v) the feasibility of sequential treatments. Phosphorus (P) removal from effluent and energetic costs associated to the process were also evaluated. Five PPCPs were studied – caffeine (CAF), bisphenol A (BPA), 17 β-estradiol (E2), ethinyl estradiol (EE2) and oxybenzone (MBPh). The ED process showed to be effective in the removal when effluent is in the anode compartment. Oxidation is suggested to be the main removal process, which was between 88 and 96%, for all the compounds, in 6 hours. Nevertheless, the presence of intermediates and/or by-products was also observed in some cases. Effluent recirculation should have a retention time in the ED cell big enough to promote removal whereas the current steps (effluent in anode compartment) slightly increased removal efficiencies (higher than 80% for all PPCPs). The sequential set of ED treatment (effluent in anode compartment) showed to be effective during both periods with a removal percentage between 80 and 95% and 73 to 88% in the case of AEM and CEM, respectively. Again, the main removal process is strongly suggested to be oxidation in the anode compartment. However, there was an increase of BOD5 and COD, which might be explained by effluent spiking, these parameters limiting the effluent discharge. From these treatments, the use of AEM, enhanced the P removal from effluent to minimize risk of eutrophication. Energetic costs of the best set-up (6 hours) are approximately 0,8€/m3 of wastewater, a value considered low, attending to the prices of other treatment processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the Model-based Systems and Qualitative Reasoning Group (Technical University of Munich), from September until December 2005. Constructed wetlands (CWs), or modified natural wetlands, are used all over the world as wastewater treatment systems for small communities because they can provide high treatment efficiency with low energy consumption and low construction, operation and maintenance costs. Their treatment process is very complex because it includes physical, chemical and biological mechanisms like microorganism oxidation, microorganism reduction, filtration, sedimentation and chemical precipitation. Besides, these processes can be influenced by different factors. In order to guarantee the performance of CWs, an operation and maintenance program must be defined for each Wastewater Treatment Plant (WWTP). The main objective of this project is to provide a computer support to the definition of the most appropriate operation and maintenance protocols to guarantee the correct performance of CWs. To reach them, the definition of models which represent the knowledge about CW has been proposed: components involved in the sanitation process, relation among these units and processes to remove pollutants. Horizontal Subsurface Flow CWs are chosen as a case study and the filtration process is selected as first modelling-process application. However, the goal is to represent the process knowledge in such a way that it can be reused for other types of WWTP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este proyecto se ha desarrollado estrategias de control avanzadas para plantas de depuración de aguas residuales urbanas que eliminan conjuntamente materia orgánica, nitrógeno y fósforo. Las estrategias se han basado en el estudio multivariable del comportamiento del sistema, que ha producido subsidios para la utilización de lazos de control feedforward, de control predictivo y de un control de costes que automáticamente enviaba las consignas más adecuadas para los controladores de proceso. Para el desarrollo de las estrategias, se ha creado un sistema virtual de simulación (simulador) de plantas de depuradoras, basado en datos de literatura. Para el caso de una planta real, se ha desarrollado un simulador de la planta de Manresa (Catalunya). Sin embargo, el sistema de Manresa se ha utilizado exclusivamente para auxiliar los ingenieros de la planta en la tomada de decisiones de cambio de configuración para que la eliminación de fósforo se dé por la ruta biológica y no por la ruta química. La implementación de los simuladores ha permitido hacer muchas pruebas que en una planta real demandarían mucho tiempo y consumirían muchos recursos energéticos y financieros. Las estrategias de control más elaboradas han podido ahorrar hasta 150.000,00 Euros por año en relación a la operación de la planta sin el control automático. Cuanto a los estudios del modelo de la planta real, se concluyó que la eliminación biológica de fósforo puede sustituir el actual proceso químico de eliminación de fósforo, bajando los costes operacionales (costes del agente precipitante).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’objectiu del present estudi és comparar els vectors de paràmetres de l’aigua, producció de fangs, costos i personal entre 2 tipus d’instal·lacions EDAR al municipi de Begues; una ja existent amb tractament secundari i terciari mitjançant un reactor biològic i una potencial amb tractament secundari i terciari mitjançant aiguamolls construïts. La finalitat del projecte és determinar, gràcies a l’estudi dels principals vectors ambientals de la infraestructura i a altres estudiats per na Susana Forero Sánchez, quina de les 2 tipologies d’instal·lació s’ajusta més al territori i a les necessitats de tractament de les aigües del mateix. Els resultats de la investigació indiquen que tant els costos d’explotació com la producció de fangs i el personal donen avantatge als aiguamolls construïts, però els costos capitals i el tractament de nutrients són favorables per a la depuradora actual. Amb el projecte de Susana Forero Sánchez, les conclusions que es poden establir en referència a la decisió d’instal·lar una depuradora o una altra segons els vectors estudiats indiquen que l’EDAR sense aiguamolls té més probabilitat de ser escollida com la més adient per les necessitats del territori d’estudi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’objectiu del present estudi és comparar els vectors de superfície, consum energètic i integració en el medi entre 2 tipus d’instal·lacions EDAR al municipi de Begues; una ja existent amb tractament secundari i terciari mitjançant un reactor biològic i una potencial amb tractament secundari i terciari mitjançant aiguamolls construïts. La finalitat del projecte és determinar, gràcies a l’estudi dels principals vectors ambientals de la infraestructura i a altres estudiats per en Jordi Gómez Castillo, quina de les 2 tipologies d’instal·lació s’ajusta més al territori i a les necessitats de tractament de les aigües del mateix. Els resultats de la investigació indiquen que els aiguamolls construïts fan un ús més productiu del sòl però ocupen l’espai de reserva disponible amb el sistema de reactor biològic. A més, consumeixen 50kWh/dia menys que l’altra instal·lació, fet que implica un 7% menys d’emissions de CO2 anuals. Finalment, tenen una millor integració en el medi i proporcionen uns beneficis auxiliars afegits. Amb el projecte d’en Jordi Gómez Castillo, les conclusions que es poden establir en referència a la decisió d’instal·lar una depuradora o una altra indiquen que l’EDAR sense aiguamolls té més probabilitat de ser escollida com la més adient per les necessitats del territori d’estudi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates faecal indicator bacteria (FIB), multiple antibiotic resistant (MAR), and antibiotic resistance genes (ARGs), of sediment profiles from different parts of Lake Geneva (Switzerland) over the last decades. MARs consist to expose culturable Escherichia coli (EC) and Enterococcus (ENT) to mixed five antibiotics including Ampicillin, Tetracycline, Amoxicillin, Chloramphenicol and Erythromycin. Culture-independent is performed to assess the distribution of ARGs responsible for, β-lactams (blaTEM; Amoxicillin/Ampicillin), Streptomycin/Spectinomycin (aadA), Tetracycline (tet) Chloramphenicol (cmlA) and Vancomycin (van). Bacterial cultures reveal that in the sediments deposited following eutrophication of Lake Geneva in the 1970s, the percentage of MARs to five antibiotics varied from 0.12% to 4.6% and 0.016% to 11.6% of total culturable EC and ENT, respectively. In these organic-rich bacteria-contaminated sediments, the blaTEM resistant of FIB varied from 22% to 48% and 16% to 37% for EC and ENT respectively, whereas the positive PCR assays responsible for tested ARGs were observed for EC, ENT, and total DNA from all samples. The aadA resistance gene was amplified for all the sediment samples, including those not influenced by WWTP effluent water. Our results demonstrate that bacteria MARs and ARGs highly increased in the sediments contaminated with WWTP effluent following the cultural eutrophication of Lake Geneva. Hence, the human-induced changing limnological conditions highly enhanced the sediment microbial activity, and therein the spreading of antibiotic resistant bacteria and genes in this aquatic environment used to supply drinking water in a highly populated area. Furthermore, the presence of the antibiotic resistance gene aadA in all the studied samples points out a regional dissemination of this emerging contaminant in freshwater sediments since at least the late nineteenth century.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’objectiu del present projecte és la proposta (disseny i estimació econòmica) d’un sistema de tractament de les aigües i els fangs generats a un escorxador porcí de Granollers. Per tal de portar a terme aquest estudi, es va realitzar una anàlisi de la situació prèvia a l’escorxador, del diagrama de flux de les instal·lacions existents, de les necessitats del sector, dels límits d’abocament fixats pel Reglament del Consorci del Besòs, i finalment de la caracterització de les aigües residuals generades (en quantitat i qualitat) així com dels fangs produïts. Arran d’aquesta anàlisi es va realitzar un estudi experimental d’optimització del tractament fisicoquímic, i en base als resultats es van generar diferents alternatives de tractament, es va simular el seu comportament, i es va fer una avaluació comparativa dels costos i rendiments estimats

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'existència d’una font de carboni adequada per l’eliminació biològica de fòsfor, és un factor decisiu per l'eliminació de fòsfor de les aigües residuals urbanes. Per a les aigües residuals amb baix contingut d'àcids grassos volàtils és necessària l’addició d’alguna font de carboni externa. El metanol és la font de carboni més utilitzada en processos a EDAR (p.ex. desnitrificació), degut al seu baix cost. Malgrat això, varis estudis proven que per l’eliminació biològica de fòsfor, aquest, no és una bona alternativa. En aquest estudi es desenvolupa un consorci amb la biomassa de digestió anaeròbia i biomassa acumuladora de polifosfat (PAO). El propòsit del consorci és la degradació de metanol en AGV, per obtenir l'activitat EBPR. A més, aquest estudi mostra la viabilitat de substituir en el consorci el metanol per altres fonts de carboni.