944 resultados para Gait cicle
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
This study tested whether the lower economy of walking in healthy elderly subjects is due to greater gait instability. We compared the energy cost of walking and gait instability (assessed by stride to stride changes in the stride time) in octogenarians (G80, n = 10), 65-yr-olds (G65, n = 10), and young controls (G25, n = 10) walking on a treadmill at six different speeds. The energy cost of walking was higher for G80 than for G25 across the different walking speeds (P < 0.05). Stride time variability at preferred walking speed was significantly greater in G80 (2.31 +/- 0.68%) and G65 (1.93 +/- 0.39%) compared with G25 (1.40 +/- 0.30%; P < 0.05). There was no significant correlation between gait instability and energy cost of walking at preferred walking speed. These findings demonstrated greater energy expenditure in healthy elderly subjects while walking and increased gait instability. However, no relationship was noted between these two variables. The increase in energy cost is probably multifactorial, and our results suggest that gait instability is probably not the main contributing factor in this population. We thus concluded that other mechanisms, such as the energy expenditure associated with walking movements and related to mechanical work, or neuromuscular factors, are more likely involved in the higher cost of walking in elderly people.
Resumo:
Aquest projecte s'emmarca dins de l'àmbit de l'assessorament psicopedagògic, concretament, en la formació del professorat per a l'ensenyament d'estratègies d'aprenentatge. El tema d'estratègies d'ensenyament/aprenentatge és massa ampli per a poder tractar-lo en un projecte com aquest, amb una limitació temporal que exigeix concretar l'actuació en els punts següents: fer una selecció prèvia d'un determinat conjunt de procediments d'aprenentatge vinculats amb la lectura, situar-lo dins d'un context escolar concret de manera que la formació vagi dirigida als docents del cicle mitjà d'educació primària d'un CEIP del Masnou i centrar l'experiència en dos d'aquests docents.
Resumo:
Es tracta d'un programa d'assessorament i intervenció psicopedagògica en una escola per a treballar el càlcul mental a primària, concretament al cicle mitjà, però també extensible a altres cicles, a partir de l'adaptació de diferents jocs de taula mitjançant la creació de tallers de matemàtiques i amb una pràctica basada en el constructivisme.
Resumo:
Purpose: To determine the evolution of fear of falling, and its relationship with gait performance after a 10-week gait and balance training program. Population and methods: Participants (N=50) were community-dwelling elderly persons enrolled voluntarily in a 10-week, low intensity, gait and balance training program. At baseline, fear of falling was assessed using a previously validated version of Tinetti's Fall Efficacy Scale (FES, range 0-120, higher score indicating higher confidence), that assesses one's confidence in performing 12 activities of daily life without falling. Gait parameters were measured over a 20m walk at preferred gait speed, using the Physilog system (Aminian K, et al., J Biomechanics, 2002). This system uses 4 kinematics sensors attached to the lower limbs and a data logger carried by the subject. Follow-up data on fear of falling and gait were collected one week after completion of the program. Results: Overall, 43 (86%) of the participants completed the program. Mean age was 78.1 years, 79% were women. At baseline, mean FES score was 98.8 (range 58-120) and mean gait speed was 0.92 m/sec (range 0.43-1.47). At follow-up, participants modestly improved their FES score (98.8±17.0 vs 103.2±16.0, P=.04) and gait speed (0.92±0.27 vs 0.99±0.26 m/sec, P<.01). In secondary analyses stratified by subject's baseline FES, those with lower than average confidence (N=21) improved significantly both FES score (84.4±11.8 vs 94.5±17.9, P<.01) and gait speed (0.79±0.26 vs 0.90±0.28 m/sec, P<.01), while no similar improvement was observed in subjects (N=22) with higher baseline confidence (112.5±6.6 vs 111.5±7.5, P=.56 and 1.03±0.22 vs 1.07±0.21 m/sec, P=.41). After adjustment for age, gender and baseline gait speed, subjects with lower baseline confidence had higher odds than the others to improve their confidence (AdjOR=10.8, 95%CI 1.8- 64.8 P=.01) and gait speed (AdjOR=3.3, 95%CI 0.6-19.7, P=.19) at follow-up. Conclusions: This pilot program of low intensity exercise modestly improved participants' fear of falling and gait speed. Interestingly, subjects with higher baseline fear of falling seemed more likely to benefit. Despite methodological limitations (pre-post comparisons, small sample), these results suggest that measuring fear of falling might be useful to better target subjects most likely to benefit from similar programs.
Resumo:
Thanks to decades of research, gait analysis has become an efficient tool. However, mainly due to the price of the motion capture systems, standard gait laboratories have the capability to measure only a few consecutive steps of ground walking. Recently, wearable systems were proposed to measure human motion without volume limitation. Although accurate, these systems are incompatible with most of existing calibration procedures and several years of research will be necessary for their validation. A new approach consisting of using a stationary system with a small capture volume for the calibration procedure and then to measure gait using a wearable system could be very advantageous. It could benefit from the knowledge related to stationary systems, allow long distance monitoring and provide new descriptive parameters. The aim of this study was to demonstrate the potential of this approach. Thus, a combined system was proposed to measure the 3D lower body joints angles and segmental angular velocities. It was then assessed in terms of reliability towards the calibration procedure, repeatability and concurrent validity. The dispersion of the joint angles across calibrations was comparable to those of stationary systems and good reliability was obtained for the angular velocities. The repeatability results confirmed that mean cycle kinematics of long distance walks could be used for subjects' comparison and pointed out an interest for the variability between cycles. Finally, kinematics differences were observed between participants with different ankle conditions. In conclusion, this study demonstrated the potential of a mixed approach for human movement analysis.
Resumo:
L’estudi de l’Anàlisi del Cicle de Vida (ACV) ha estat realitzat a l’empresa CRODA Ibèrica S.A - Mevisa Site, en concret a la línia productiva on s’hi fabrica el monoestearat de glicerina utilitzant una eina informàtica comercial denominada SIMAPRO que analitza i compara els aspectes mediambientals d’un producte d’una manera sistemàtica i consistent seguint les recomanacions de les normes ISO 14040
Resumo:
Treball que recull l'experiència de l’autora durant 4 mesos en l’IES Vallvera. Durant aquest temps ha pogut observar, aprendre i conèixer les tasques dels professionals de la psicopedagogia. L’IES Vallvera és un centre que acull molts alumnes immigrants, i per tant el tracte amb alumnes i l’assessorament d’aquests és el treball del dia a dia de la psicopedagoga del centre
Resumo:
Aquesta memòria és un estudi sobre l’avaluació ambiental del nitrogen a Catalunya, tot analitzant l’evolució que aquest element tant important ha tingut des del 1997 al 2003 en el nostre país
Resumo:
Estudi de la Cydia pomonella (L.), corc de les pomes i de les peres que és una plaga molt important en tot l’àmbit estatal i del control que cal fer-ne per tal d’evitar la pèrdua total o parcial de la collita
Resumo:
Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.
Resumo:
The aim of this study was to examine the effect of an individualized overground walking interval training on gait performance [i.e., speed and energy cost (C(w))] in healthy elderly individuals. Twenty-two older adults were assigned to either a training group (TG; n=12, 73.4+/-3.9yr) or a non-training control group (CG; n=10, 70.9+/-9.6yr). TG participated in a 7-week individualized walking interval training at intensities progressing from 50 to 100% of ventilatory threshold (T (VE)). Aerobic fitness [maximal oxygen uptake (V O(2max)) and T (VE)], preferred walking speed (PWS), gross and net C(w) (GC(w) and NC(w), respectively) and relative effort (%V O(2max)) at PWS measured before training (PWS(1)) were assessed prior and following the intervention. All outcomes were measured on a treadmill. Significant improvements in GC(w) (-8%; P=0.007), NC(w) (-12%; P=0.003), relative effort (%V O(2max): -12%; P<0.001) and PWS (+12%; P<0.001) were observed in TG but not in CG (P>0.71). V O(2max) and T (VE) remained unchanged in both groups (P>0.57). Changes in GC(w) at PWS(1) (difference between GC(w) at PWS(1) measured pre and post intervention) were inversely correlated with changes in PWS (difference between pre and post PWS; r=-0.67; P=0.02). The decreased C(w) at PWS(1), with no concomitant improvement in aerobic fitness, represents the main contributing factor for the reduction of the relative effort at this speed. This also allows elderly people to increase their PWS post training. Therefore, the present walking training may be an effective way to improve walking performance and delay mobility impairment in older adults.