970 resultados para GPS INS
Resumo:
This research involved two studies: one to determine the local geoid to obtain mean sea level elevation from a global positioning system (GPS) to an accuracy of ±2 cm, and the other to determine the location of roadside features such as mile posts and stop signs for safety studies, geographic information systems (GIS), and maintenance applications, from video imageries collected by a van traveling at traffic speed.
Resumo:
Cell-to-cell communication mediated by gap junctions made of Connexin36 (Cx36) contributes to pancreatic β-cell function. We have recently demonstrated that Cx36 also supports β-cell survival by a still unclear mechanism. Using specific Cx36 siRNAs or adenoviral vectors, we now show that Cx36 downregulation promotes apoptosis in INS-1E cells exposed to the pro-inflammatory cytokines (IL-1β, TNF-α and IFN-γ) involved at the onset of type 1 diabetes, whereas Cx36 overexpression protects against this effect. Cx36 overexpression also protects INS-1E cells against endoplasmic reticulum (ER) stress-mediated apoptosis, and alleviates the cytokine-induced production of reactive oxygen species, the depletion of the ER Ca(2+) stores, the CHOP overexpression and the degradation of the anti-apoptotic protein Bcl-2 and Mcl-1. We further show that cytokines activate the AMP-dependent protein kinase (AMPK) in a NO-dependent and ER-stress-dependent manner and that AMPK inhibits Cx36 expression. Altogether, the data suggest that Cx36 is involved in Ca(2+) homeostasis within the ER and that Cx36 expression is downregulated following ER stress and subsequent AMPK activation. As a result, cytokine-induced Cx36 downregulation elicits a positive feedback loop that amplifies ER stress and AMPK activation, leading to further Cx36 downregulation. The data reveal that Cx36 plays a central role in the oxidative stress and ER stress induced by cytokines and the subsequent regulation of AMPK activity, which in turn controls Cx36 expression and mitochondria-dependent apoptosis of insulin-producing cells.
Resumo:
Échelle(s) : [ca 1:2 440 000], échelle 100 kilomètres [= 4,1 cm]
Resumo:
We analyze how unemployment, job finding and job separation rates react to neutral and investment-specific technology shocks. Neutral shocks increase unemployment and explain a substantial portion of unemployment volatility; investment-specific shocks expand employment and hours worked and mostly contribute to hours worked volatility. Movements in the job separation rates are responsible for the impact response of unemployment while job finding rates for movements along its adjustment path. Our evidence qualifies the conclusions by Hall (2005) and Shimer (2007) and warns against using search models with exogenous separation rates to analyze the effects of technology shocks.
GPs and patients with chronic pain: is the breakdown of doctor-patient relationship bound to happen?
Resumo:
We analyze how unemployment, job finding and job separation rates reactto neutral and investment-specific technology shocks. Neutral shocks increaseunemployment and explain a substantial portion of it volatility; investment-specificshocks expand employment and hours worked and contribute to hoursworked volatility. Movements in the job separation rates are responsible for theimpact response of unemployment while job finding rates for movements alongits adjustment path. The evidence warns against using models with exogenousseparation rates and challenges the conventional way of modelling technologyshocks in search and sticky price models.
Genetic Variations and Diseases in UniProtKB/Swiss-Prot: The Ins and Outs of Expert Manual Curation.
Resumo:
During the last few years, next-generation sequencing (NGS) technologies have accelerated the detection of genetic variants resulting in the rapid discovery of new disease-associated genes. However, the wealth of variation data made available by NGS alone is not sufficient to understand the mechanisms underlying disease pathogenesis and manifestation. Multidisciplinary approaches combining sequence and clinical data with prior biological knowledge are needed to unravel the role of genetic variants in human health and disease. In this context, it is crucial that these data are linked, organized, and made readily available through reliable online resources. The Swiss-Prot section of the Universal Protein Knowledgebase (UniProtKB/Swiss-Prot) provides the scientific community with a collection of information on protein functions, interactions, biological pathways, as well as human genetic diseases and variants, all manually reviewed by experts. In this article, we present an overview of the information content of UniProtKB/Swiss-Prot to show how this knowledgebase can support researchers in the elucidation of the mechanisms leading from a molecular defect to a disease phenotype.
Resumo:
During free walking, gait is automatically adjusted to provide optimal mechanical output and minimal energy expenditure; gait parameters, such as cadence, fluctuate from one stride to the next around average values. It was described that this fluctuation exhibited long-range correlations and fractal-like patterns. In addition, it was suggested that these long-range correlations disappeared if the participant followed the beep of metronome to regulate his or her pace. Until now, these fractal fluctuations were only observed for stride interval, because no technique existed to adequately analyze an extended time of free walking. The aim of the present study was to measure walking speed (WS), step frequency (SF) and step length (SL) with high accuracy (<1 cm) satellite positioning method (global positioning system or GPS) in order to detect long-range correlations in the stride-to-stride fluctuations. Eight participants walked 30 min under free and constrained (metronome) conditions. Under free walking conditions, DFA (detrended fluctuation analysis) and surrogate data tests showed that the fluctuation of WS, SL and SF exhibited a fractal pattern (i.e., scaling exponent alpha: 0.5 < alpha < 1) in a large majority of participants (7/8). Under constrained conditions (metronome), SF fluctuations became significantly anti-correlated (alpha < 0.5) in all participants. However, the scaling exponent of SL and WS was not modified. We conclude that, when the walking pace is controlled by an auditory signal, the feedback loop between the planned movement (at supraspinal level) and the sensory inputs induces a continual shifting of SF around the mean (persistent anti-correlation), but with no effect on the fluctuation dynamics of the other parameters (SL, WS).
Resumo:
Échelle(s) : [ca 1:2 440 000], échelle 100 kilomètres [= 4,1 cm]
Resumo:
Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications.
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
Os receptores de navegação do sistema de posicionamento global (GPS), comumente utilizados pelo setor agrícola, em geral, apresentam precisão posicional < 10,0 m. Em uma amostragem sistemática de solos, as subamostras deverão ser coletadas num raio não superior a 3 m do ponto central georreferenciado. A presente nota técnica visou confrontar a precisão e exatidão desse tipo de equipamento com a necessidade exigida em amostragem sistematizada de solo. Uma área com aproximadamente 17 ha, no campus I da Universidade de Passo Fundo, foi levantada com três receptores GPS de navegação e Estação Total-ET (controle). Pontos centrais de quadrículas de 2 ha, gerados pelo programa Campeiro®, foram locados no campo com os mesmos equipamentos. Sobre esses pontos, materializados no campo, foram novamente tomadas as suas coordenadas, com auxílio da estação total. Assim, as coordenadas X e Y foram submetidas à ANOVA, confrontando-se as médias obtidas pela ET com as dos receptores de GPS pela diferença honesta significativa do teste de Tukey (p < 0,01). Quanto à exatidão, calcularam-se, por Pitágoras, as distâncias lineares entre os pontos gerados pelos GPS e pela ET, assumindo-se não exatas quando ultrapassaram os 3 m de raio preconizado pelo Manual de Adubação e Calagem do Rio Grande do Sul e de Santa Catariana para coleta de solo. A exatidão das coordenadas dos receptores GPS variou de -10 m a +3 m para X e de -4 m a +7 m para Y. Apenas um ponto central dos oito locados com os receptores de GPS de navegação no centro das quadrículas apresentou exatidão compatível com a exigida pela prática. Isso indica que esse tipo de equipamento, com baixa precisão e exatidão, não deve ser utilizado para amostragem sistematizada de solos.
Resumo:
The paper gives the theory of airborne GPs related to Photogrammetry and the results of a self calibration used to validate the theory. Accordingly, no ground control points are required for mapping using a strip or block of photographs provided the site is within 10 Km of the calibration site.